Aci 318-19 PT-SL Example 001
Aci 318-19 PT-SL Example 001
PROBLEM DESCRIPTION
The purpose of this example is to verify the slab stresses and the required area of
mild steel strength reinforcing for a post-tensioned slab.
A one-way, simply supported slab is modeled. The modeled slab is 10 inches thick
by 36 inches wide and spans 32 feet, as shown in shown in Figure 1. A 36-inch-
wide design strip was centered along the length of the slab and was defined as an
A-Strip. B-strips were placed at each end of the span perpendicular to the Strip-A
(the B-Strips are necessary to define the tendon profile). A tendon, with two
strands having an area of 0.153 square inches each, was added to the A-Strip. The
self weight and live loads were added to the slab. The loads and post-tensioning
forces are shown below. The total factored strip moments, required area of mild
steel reinforcement, and slab stresses are reported at the mid-span of the slab.
Independent hand calculations were compared with the results and summarized for
verification and validation.
RESULTS COMPARISON
The total factored moments, required mild steel reinforcing and slab stresses are
compared to the independent hand calculations in Table 1.
INDEPENDENT
FEATURE TESTED RESULTS DIFFERENCE
RESULTS
Factored moment,
1429.0 1428.3 -0.05%
Mu (Ultimate) (k-in)
Area of Mild Steel req’d,
2.251 2.251 0.00%
As (sq-in)
Transfer Conc. Stress, top
−0.734 −0.735 0.14%
(D+PTI), ksi
Transfer Conc. Stress, bot
0.414 0.414 0.00%
(D+PTI), ksi
Normal Conc. Stress, top
−1.518 −1.519 0.07%
(D+L+PTF), ksi
Normal Conc. Stress, bot
1.220 1.221 0.08%
(D+L+PTF), ksi
Long-Term Conc. Stress,
−1.134 −1.135 0.09%
top (D+0.5L+PTF(L)), ksi
Long-Term Conc. Stress,
0.836 0.837 0.12%
bot (D+0.5L+PTF(L)), ksi
CONCLUSION
The results show an acceptable comparison with the independent results.
CALCULATIONS:
Design Parameters:
φ =0.9
Mild Steel Reinforcing Post-Tensioning
Loads:
Dead, self-wt = 10 / 12 ft × 0.150 kcf = 0.125 ksf (D) × 1.2 = 0.150 ksf (Du)
Live, 0.100 ksf (L) × 1.6 = 0.160 ksf (Lu)
Total =0.225 ksf (D+L) 0.310 ksf (D+L)ult
wl12
Ultimate Moment, M U = = 0.310 klf × 322/8 = 119.0 k-ft = 1429.0 k-in
8
f 'c
Ultimate Stress in strand, f PS = (span-to-depth ratio > 35)
f SE + 10000 +
300 ρ P
4, 000
= 175,500 + 10, 000 +
300 ( 0.000944 )
= 199, 624 psi ≤ 205,500 psi
P ( f PS ) 2 ( 0.153)(199.62
Fult , PT A=
Ultimate force in PT, = = ) 61.08 kips
s ( f )y
Ultimate force in RC, =
Fult , RC A= ( 60.0 ) 120.0 kips
2.00(assumed)=
Total Ultimate force, Fult ,Total = 61.08 + 120.0 = 181.08 kips
a 1.48 ( )
Ultimate moment due to PT, M ult , PT
= Fult , PT d − =φ 61.08 9 − 0.9= 454.1 k-in
2 2
Net ultimate moment, M net =M U − M ult , PT = 1429.0 − 454.1 =974.9 k-in
M net 974.9
Required area of mild steel reinforcing,
= AS = = 2.18 in 2
a 1.48
φ f y d − 0.9 ( 60 ) 9 −
2 2
Note: The required area of mild steel reinforcing was calculated from an assumed amount of
steel. Since the assumed value and the calculated value are not the same a second iteration can be
performed. The second iteration changes the depth of the stress block and the calculated area of
steel value. Upon completion of the second iteration the area of steel was found to be 2.25in2
The stress in the tendon at transfer = jacking stress − stressing losses = 216.0 − 27.0
= 189.0 ksi
The force in the tendon at transfer, = 189.0 ( 2 ) ( 0.153) = 57.83 kips
2
Moment due to dead load,= M D 0.125 ( 3)(=32 ) 8 48.0 = k-ft 576 k-in
Moment due to PT,= M PT F= PTI (sag) 57.83
= ( 4 in ) 231.3 k-in
FPTI M D − M PT −57.83 576.0 − 231.3
Stress in concrete, f = ± = ± , where S = 600 in3
A S 10 ( 36 ) 600
f = −0.161 ± 0.5745
f = - 0.735(Comp)max, 0.414(Tension)max
Tendon stress at normal = jacking − stressing − long-term = 216.0 − 27.0 − 13.5 = 175.5 ksi
The force in tendon at Normal, = 175.5 ( 2 ) ( 0.153) = 53.70 kips
2
Moment due to dead load,
= M D 0.125 ( 3)(= 32 ) 8 48.0
= k-ft 576 k-in
2
Moment due to dead load,
= M L 0.100 ( 3)(=
32 ) 8 38.4
= k-ft 461 k-in
Moment due to PT, PTI (sag)
M PT F=
= 53.70
= ( 4 in ) 214.8 k-in
Tendon stress at normal = jacking − stressing − long-term = 216.0 − 27.0 − 13.5 = 175.5 ksi
The force in tendon at Normal, = 175.5 ( 2 ) ( 0.153) = 53.70 kips
2
Moment due to dead load,
= M D 0.125 ( 3)(= 32 ) 8 48.0
= k-ft 576 k-in
2
Moment due to dead load,
= 32 ) 8 38.4
M L 0.100 ( 3)(= = k-ft 460 k-in
Moment due to PT, PTI (sag)
M PT F=
= 53.70
= ( 4 in ) 214.8 k-in