LAND USE AND ZONING

TABLE OF CONTENTS

ARCHITECTURAL
A1
SITE DEVELOPMENT PLAN
VICINITY MAP
EXTERIOR PERSPECTIVE
A2
FLOOR PLAN
REFLECTED CEILING PLAN
TILE LAYOUT PLAN
A3 LINE AND GRADE
ELEVATIONS
SECTIONS
SCHEDULE OF DOORS & WINDOWS
ROOF PLAN

ARCHITECTURAL

STRUCTURAL
S1
STRUCTURAL NOTES
MASONRY NOTES
S2
FOUNDATION PLAN
GRADE BEAMS PLAN
SCHEDULE OF COLUMNS & STRUCTURAL
FOOTING
TYP. WALL FOOTING DETAIL
A EXTERIOR PERSPECTIVE TYP. COLUMN ELEVATION DETAIL
1 SCALE: N.T.S
S3
BUILDING LINE SECOND FLOOR FRAMING PLAN
PROPERTY LINE TYP. BEAM REBAR ARRANGEMENT
DETAIL
ROOF LINE
TYP. BEAM SECTION
SCHEDULE OF COLUMNS
SCHEDULE OF BEAMS
12000 N ELECTRICAL
S4
7850 4150 TYP. TWO WAY SLAB DETAIL
TYP. ONE WAY SLAB DETAIL
ONE WAY SLAB DETAIL
TWO WAY SLAB DETAIL

FIREWALL S5
ROOF SECTION
TYP. PURLIN CONNECTION DETAIL
COURTYARD
D. TYP. SECTION DETAIL
YPASS R NAMIKI
CB TYP. STAIR PLAN
PORA FOODHOUSE

BLUE HEIGHTS MECHANICAL


WATER REFILLING
RD. PLUMBING & SANITARY
BYPASS STATION
C
PORA
7692

P1
THE SITE JOSE S. LAPID ISOMETRIC
UP DISTRICT HOSP. GF WATER LINE LAYOUT
FIREWALL
10550

10550

2F WATER LINE LAYOUT


DIRTY GF SANITARY LINE LAYOUT
KIT. 2F SANITARY LINE LAYOUT
LAUN.
ACS HARDRWARE BLUE HEIGHTS
HOMES CLUB P2 SANITARY
HOUSE GENERAL NOTES
TYP. CATCH BASIN DETAIL
TYP. SEPTIC VAULT DETAIL
2858

LANDSCAPE/OPEN SPACE ELECTRICAL


E1
GARAGE (1)
PROPERTY LINE
GENERAL NOTES
VICINITY MAP
TYP. PANEL BOARD DIAGRAM
2830 9170
LEGEND AND SYMBOLS
12000 TYP. PANEL DIAGRAM

E2
GF LIGHTING LAYOUT
A SITE DEVELOPMENT PLAN A VICINITY MAP 2F LIGHTING LAYOUT
GF POWER LAYOUT
2 SCALE: 1:80 MTS. 3 SCALE: N.T.S
2F POWER LAYOUT
SCHEDULE OF LOADS AND
CALCULATION
CONC. SERVICE ENTRANCE/
METER POLE DETAIL.

CERTIFIED BY: PRC NO. 0164386 PROJECT TITLE: PROJECT OWNER: R.A 9266, ART. IV SEC. 33 SHEET CONTENT: REVISIONS: SHEET NO.
RGA SQUARED CONSTRUCTION SERVICES PTR NO. 7611385 PROPOSED TWO (2) STOREY
Designer Contractor Fabricator REGIN ADRIAN Q. LANSANG, RCE , RMP
ISSUED ON: June 14, 2022 THREE (3) BEDROOM RESIDENTIAL
Ms. Jechenn D. Cura Drawings and specifications and other contract documents duly signed, stamped of sealed, as instruments
of service, are the intellectual property and documents of the architect, whether the object for which they are
made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents
AS SHOWN
A
CIVIL ENGINEER for use in the repetition of and for other projects or buildings, whether executed partly or in whole, without the
LOCATION: ADDRESS: written consent of architect or author of said documents. 1 3
Office Adress: #960 San Vicente, Guagua, Pampanga I CERTIF THAT THIS WORK WAS PREPARED BY ME
OR DONE UNDER MY DIRECT SUPERVISION ISSUED AT: Babo Sacan, Porac, Pampanga Calantas, Floridablanca, Pampanga
12000 11000 12000 11000
7850 4150 6850 4150 7850 4150 6850 4150
1000 4950 1900 2675 1500 2675 1000 4950 1900 2675 1500 2675

FIREWALL

1200 950
1200 950
ACU ACU
1500

1500
REF
PWDR. W5 COURTYARD

2150
2150

2150

2150
LANDSCAPE/OPEN AREA

0.10-

PVC CEILING PANEL


RANGE
RM. 0.40+ 0.0 -+ W1
T&B W1

3200
3200

3200

3200
0.45+ 9mm THK. 9mm THK.
D3
UP
BEDROOM 1 BEDROOM 2 9mm THK. GYPSUM GYPSUM
W3 BOARD BOARD
GYPSUM
4400

4400
0.05-
KITCHEN
1700

1700
W1 W5 W5 PVC CEILING PANEL
SINK BOARD
D2
9mm THK.
CLO. D3 CLO.

2296

2296
NOOK GYPSUM
0.05- T&B BOARD

7550

7550

7550

7550
1200

1200

1200

1200
D3 D3

3400

3400
0.0 -+ D3
UP D3
0.45+ LIVING HALLWAY
0.10- 9mm THK. 9mm THK.
AREA GYPSUM GYPSUM
0.0 -+
UP DOWN BOARD BOARD
DINING
9mm THK.
AREA D3 WALK IN CLOSET
10550

10550

10550

10550

PVC CEILING PANEL


DIRTY FAMILY GYPSUM

4350

4350
ACU 0.0 -+ BOARD
KIT. 0.45+ AREA
3150

3150

3150

3150
3104

3104
0.30+
D3 W1
MASTER'S 9mm THK.
PORCH ACU 9mm THK. GYPSUM

2000

2000
BEDROOM
SHOE BOARD
LAUN. GYPSUM

FIREWALL
RACK W2 D2
SHOE W4 BOARD 9mm THK.
0.30+ BALCONY
RACK GYPSUM
D1 0.10- BOARD

5000
5000
W4 W1 W1 POLYCARBONATE
PVC CEILING PANEL
0.0 -+ UP ROOFING SHEET
0.0 -+
3000

3000

3000

3000
LANDSCAPE/OPEN SPACE

GARAGE (1)
PROPERTY LINE

2000 2400 3450 4150 1000 2400 3300 4300 2000 2400 3450 4150 1000 2400 3300 4300
12000 11000 12000 11000

A GROUND FLOOR PLAN A SECOND FLOOR PLAN A REFLECTED CEILING PLAN (GF) A REFLECTED CEILING PLAN (2F)
1 SCALE: 1:100 MTS. 2 SCALE: 1:100 MTS. 5 SCALE: 1:100 MTS. 6 SCALE: 1:100 MTS.

11750

8650 3100
12000 11000
7850 4150 6850 4150
1000 4950 1900 2675 1500 2675

1200 950
1500

30X30 cm.

1100
2150
PORCELAIN
2150

TILES 30X30 cm.


PORCELAIN
3200
3200

WOOD PLANKS VINYL FLOOR TILES VINYL FLOOR


TILE TILE
4400

1700

3950
30X30 cm.

2296
PORCELAIN
TILES
7550

7550
1200
1200

WOOD PLANKS
3400

WOOD PLANKS
VINYL FLOOR
10550

10550

TILE LONG SPAN ROOF


4350

8300

8300
3150

3104
3150

CONCRETE FINISH

7200
FLOORING VINYL FLOOR
60x60cm. TILE
2000

PORCELAIN
TILES CONCRETE FINISH
FLOORING

4350
CONCRETE FINISH
5000

FLOORING
3000

3000

2000 2400 3450 4150 1000 2400 3300 4300


12000 11000 1000 10750

11750

A TILE LAYOUT PLAN (GF) A TILE LAYOUT PLAN (2F) A ROOFING PLAN LAYOUT
3 SCALE: 1:100 MTS. 4 SCALE: 1:100 MTS. 7 SCALE: 1:80 MTS.

CERTIFIED BY: PRC NO. 0164386 PROJECT TITLE: PROJECT OWNER: R.A 9266, ART. IV SEC. 33 SHEET CONTENT: REVISIONS: SHEET NO.
RGA SQUARED CONSTRUCTION SERVICES PTR NO. 7611385 PROPOSED TWO (2) STOREY
Designer Contractor Fabricator REGIN ADRIAN Q. LANSANG, RCE , RMP
ISSUED ON: June 14, 2022 THREE (3) BEDROOM RESIDENTIAL
Ms. Jechenn D. Cura Drawings and specifications and other contract documents duly signed, stamped of sealed, as instruments
of service, are the intellectual property and documents of the architect, whether the object for which they are
made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents
AS SHOWN
A
CIVIL ENGINEER for use in the repetition of and for other projects or buildings, whether executed partly or in whole, without the
LOCATION: ADDRESS: written consent of architect or author of said documents. 2 3
Office Adress: #960 San Vicente, Guagua, Pampanga I CERTIF THAT THIS WORK WAS PREPARED BY ME
OR DONE UNDER MY DIRECT SUPERVISION ISSUED AT: Babo Sacan, Porac, Pampanga Calantas, Floridablanca, Pampanga
CORNER GLASS ON ANALOK ALUM. FRAME SLIDING WINDOW ON ANALOK ALUM. FRAME
PAINTED CONCRETE WHITESMOKE FN. (FIREWALL) SLIDING WINDOW ON ANALOK ALUM. FRAME
PANEL TYPE MAHOGANY WOOD DOOR ON ALUM. DOOR JAMB
PAINTED CONCRETE BEIGE FN. (EXTERIOR WALL)
SLIDING DOOR ON ANALOK ALUM. FRAME
SLIDING WINDOW ON ANALOK ALUM. FRAME 1200 500 1500 1800

APEX APEX

1050
1050

1200
T.O.B T.O.B
F.C.L

1800

600
F.C.L

2100
2600
2600

6450
6450

2ND FLR.

900

900
2ND FLR.

F.C.L F.C.L

300
W1 W2 W3 W4

2800
2800

F.F.L F.F.L

N.G.L N.G.L

A FRONT ELEVATION A LEFT SIDE ELEVATION


500 1300 1500 780
1 SCALE: 1:100 MTS. 4 SCALE: 1:100 MTS.

600
PAINTED CONCRETE BEIGE FN. (EXTERIOR WALL)

2150

2100

2100
AWNING WINDOW ON ANALOK ALUM. FRAME

1500
W5 D1 D2 D3
APEX APEX
1050

1050
T.O.B T.O.B A SCHEDULE OF DOORS & WINDOWS
F.C.L F.C.L
D1 7 SCALE: 1:40 MTS.
2600

2600
HALLWAY MASTER'S
BALCONY BEDROOM DESCRIPTION: PANEL TYPE MAHOGANY WOOD DOOR ON ALUM. DOOR JAMB
6450

6450
FIREWALL 2ND FLR. TYPE: SWING TYPE
2ND FLR.
QUANTITY: 1
F.C.L F.C.L LOCATION: MAIN ENTRY/PORCH
2800

2800
D2
PORCH
GARAGE
F.F.L F.F.L DESCRIPTION: SLIDING DOOR ON ANALOK ALUM. FRAME
TYPE: SLIDING GLASS DOOR
N.G.L N.G.L QUANTITY: 2
LOCATION: BALCONY & LIVING AREA
D3

A REAR ELEVATION A LONGITUDINAL SECTION DESCRIPTION: PANEL TYPE MAHOGANY WOOD DOOR ON ALUM. DOOR JAMB
TYPE: SWING TYPE
2 SCALE: 1:100 MTS. 5 SCALE: 1:100 MTS.
QUANTITY: 8
LOCATION: MASTER'S BEDROOM, KITCHEN, POWDER RM, STORAGE, ALL T&B, BEDROOM 1 & 2

W1

PAINTED CONCRETE WHITESMOKE FN. (FIREWALL) DESCRIPTION: SLIDING WINDOW ON ANALOK ALUM. FRAME
TYPE: SLIDING GLASS WINDOW
QUANTITY: 6
LOCATION: MASTER'S BEDROOM, BEDROOM 1 & 2, LIVING AREA
W2

DESCRIPTION: AWNING WINDOW ON ANALOK ALUM. FRAME


APEX APEX TYPE: AWNING GLASS WINDOW
1050

1050

QUANTITY: 2
T.O.B T.O.B LOCATION: SECOND FLOOR HALLWAY & FAMILY AREA
F.C.L F.C.L W3
2600

2600

BEDROOM 1 FAMILY
AREA DESCRIPTION: SLIDING WINDOW ON ANALOK ALUM. FRAME
6450

FIREWALL
6450

TYPE: SLIDING GLASS WINDOW


2ND FLR. 2ND FLR. QUANTITY: 1
F.C.L F.C.L LOCATION: KITCHEN
2800

W4
2800

KITCHEN
DESCRIPTION: CORNER GLASS WINDOW ON ANALOK ALUM. FRAME
F.F.L F.F.L TYPE: FIXED GLASS WINDOW
N.G.L N.G.L QUANTITY: 1
LOCATION: STAIRS

W5
A RIGHT SIDE ELEVATION A CROSS SECTION
DESCRIPTION: AWNING WINDOW ON ANALOK ALUM. FRAME
3 SCALE: 1:100 MTS. 6 SCALE: 1:100 MTS.
TYPE: AWNING GLASS WINDOW
QUANTITY: 3
LOCATION: POWDER ROOM & MASTER'S T&B

CERTIFIED BY: PRC NO. 0164386 PROJECT TITLE: PROJECT OWNER: R.A 9266, ART. IV SEC. 33 SHEET CONTENT: REVISIONS: SHEET NO.
RGA SQUARED CONSTRUCTION SERVICES PTR NO. 7611385 PROPOSED TWO (2) STOREY
Designer Contractor Fabricator REGIN ADRIAN Q. LANSANG, RCE , RMP
ISSUED ON: June 14, 2022 THREE (3) BEDROOM RESIDENTIAL
Ms. Jechenn D. Cura Drawings and specifications and other contract documents duly signed, stamped of sealed, as instruments
of service, are the intellectual property and documents of the architect, whether the object for which they are
made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents
AS SHOWN
A
CIVIL ENGINEER for use in the repetition of and for other projects or buildings, whether executed partly or in whole, without the
LOCATION: ADDRESS: written consent of architect or author of said documents. 3 3
Office Adress: #960 San Vicente, Guagua, Pampanga I CERTIF THAT THIS WORK WAS PREPARED BY ME
OR DONE UNDER MY DIRECT SUPERVISION ISSUED AT: Babo Sacan, Porac, Pampanga Calantas, Floridablanca, Pampanga
STRUCTURAL NOTES
GENERAL: AT LEAST 200mm AT LEAST 200mm
1.ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE. 8.TABLE OF LAP SPLICES
REINFORCING STEEL: A
2.DO NOT SCALE DRAWINGS. ALL DIMENSIONS SHOULD BE READ OR 1.STEEL REINFORCEMENT SHALL BE GRADE 33 IN ACCORDANCE WITH PNS PARAMETERS - - LINTEL BEAM
COMPUTED. ANY DISCREPANCIES FOUND ON THE WRITTEN DIMENSIONS 49.
fc'=20.7 MPa fy=230 MPa
SHOULD BE RAISED TO THE ATTENTION OF THE ENGINEER PRIOR TO BAR DIAMETER STANDARD TENSION SPLICE LENGTH (mm)*
EXECUTION OF THE WORK. 2.UNLESS APPROVED BY THE ENGINEER, WELDING OF REINFORCING BARS (mm) HOOK (mm),ldh CLASS "A" CLASS "B"
SHALL NOT BE PERMITTED. 10 160 300 400
3.ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH THE PROJECT
12 200 300 400
B WINDOW
OPENING
SPECIFICATIONS & OTHER PROJECT DOCUMENTS. 3.REINFORCING STEEL BARS MUST BE FREE FROM OIL, GREASE, LOOSE RUST, - -
16 260 400 520
LOOSE MILL SACK OR OTHER HARMFUL MATTER IMMEDIATELY BEFORE
20 320 500 650
EARTHWORKS: POURING CONCRETE.
25 400 750 975
28 450 840 1100 FFL
4.LAP SPLICE SHALL COMPLY WITH ACI-318M-14 AND NSCP C101-15.
1.UNLESS NOTED OTHERWISE ALL FILL MATERIALS SHOULD BE SELECTED
FROM COMMONLY EXCAVATED MATERIAL WHICH ARE FREE FROM * For top bars (more than 300mm of concrete placed below the
C
5.THE MINIMUM CLEAR COVER FOR REINFORCEMENTS SHALL BE AS horizontal reinforcement) multiply the above values by 1.3 - -
ORGANIC AND HAZARDOUS MATERIALS AND GENERAL DEBRIS,FILL
FOLLOWS, UNLESS OTHERWISE SHOWN ON THE DRAWINGS:
MATERIALS SHALL BE INERT WELL GRADED AND GRANULAR MATERIAL WITH
A MAXIMUM SIZE NOT EXCEEDING 75mm. STRUCTURAL ELEMENTS CONCRETE COVER,mm 9.FORMWORKS REMOVAL
1200>W<3400mm
FOUNDATION: FOOTING 75

GROUND SLAB 40 MINIMUM TIME REQUIRED CHB"t"


1.IN ABSENCE OF SOIL INVESTIGATION REPORT, AND IN ACCORDNACE STRUCTURAL ELEMENTS
BEFORE REMOVAL
WITH SECTION 304.2 OF NSCP 2015, THE ALLOWABLE BEARING CAPACITY SUSPENDED SLAB 20
FOOTING 24 HRS
USED FOR FOUNDATION IS 100 kPa. BEAMS STIRRUPS &
40 SUSPENDED SLAB 21* DAYS CHB VERTICAL
COLUMN TIES
2.UNIT WEIGHT OF SOIL CONSIDERED IS 18 kN/m3. REINFORCEMENT
CONCRETE EXPOSED COLUMNS 48 HRS
TO EARTH BUT POURED 50
3.THE CONTRACTOR SHALL NOTIFY THE ENGINEER AFTER FOOTING 2 - 12mmØ

250 (min)
AGAINST FORMS BEAMS SOFFIT FORMS 21* DAYS
EXCAVATION HAVE BEEN COMPLETED TO CONFIRM THE DESIGN SOIL
CONCRETE POURED 75 10mmØ STIRRUPS
BEARING CAPACITY. DIRECTLY TO EARTH BEAMS SIDE FORMS 24 HRS AT 300mm ON CENTER
*IT CAN BE REMOVED AFTER A MINIMUM OF14 DAYS IF
CONCRETE: 6.STANDARD HOOKS: APPROVED BY THE ENGINEER

3.THE CONCRETE DESIGN AND CONSTRUCTION WORKS ARE IN


ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE (ACI 318M-14) TYPE OF STANDARD HOOK BAR SIZE,d
BEND STRAIGHT
DIAMETER,D EXTENSION, lext
MASONRY: W<1200mm
AND THE NATIONAL STRUCTURAL CODE OF THE PHILIPPINES (NSCP 90 DEGREE HOOK CHB"t"
Ø10mm to Ø25mm 6d
C101-15). Point at which HORIZONTAL REINFORCEMENT
SCHEDULE OF STRUCT'L. CONCRETE bar is developed
VERTICAL REINFORCEMENT

d
AT 28 DAYS COMPRESSIVE STRENGTH Ø28mm to Ø36mm 8d 12d
GROUTED CELL CHB VERTICAL
28-DAYS COMPRESSIVE D HORIZONTAL

lext
STRUCTURAL ELEMENTS SPACING REINFORCEMENT
STRENGTH (fc') Ø40mm & Ø58mm 10d

200(min)
FOOTING 3,000psi (20.70 MPa)

t(mm)
180 DEGREE HOOK 1-12mmØ
Ø10mm to Ø25mm 6d
BEAMS, COLUMNS & 3,000psi (20.70 MPa)
SUSPENDED SLAB Point at which
bar is developed LARGER OF 4d &
SLAB ON FILL, RET.
d

Ø28mm to Ø36mm 8d
WALLS, CONC. FOR 65mm
FENCE, LINTEL BEAMS
2,500 psi (17.24 MPa)
D SCHEDULE OF MASONRY WALL SECTION A
& LINTEL COLUMNS lext Ø40mm & Ø58mm 10d
REINFORCEMENT
LEAN CONC. 1,500 psi (10.34 MPa) t GROUTED
HORIZONTAL VERTICAL
(mm) CELL
DIA. SPACING DIA. SPACING 1 - 16mmØ
2.AGGREGATES SHALL BE CHEMICALLY INERT, STRONG, HARD AND 7.STIRRUP & TIE HOOKS: HORIZONTAL CHB
150 10 EVERY 3 LAYERS 10 600mm ALL CELLS
DURABLE, AND OF LIMITED POROSITY AND FREE FROM ADHERING REINFORCEMENT
BEND STRAIGHT 100 10 EVERY 3 LAYERS 10 600mm ALL CELLS CHB"t"
COATINGS AND ORGANIC OR OTHER IMPURITIES THAT MAY CAUSE TYPE OF STANDARD HOOK BAR SIZE,d
DIAMETER,D EXTENSION, lext
CORROSION OF THE REINFORCEMENT OR MAY IMPAIR THE STRENGTH AND
90 DEGREE HOOK TYPICAL DOOR/WINDOW 150
DURABILITY OF THE CONCRETE. Ø10mm to Ø16mm 4d
LARGER OF 4d &
75mm OPENING & LINTEL BEAM DETAIL
d

SCHEDULE OF CONCRETE AGGREGATES AT LEAST 200mm AT LEAST 200mm


SECTION B
W(mm)
ITEMS AGGREGATE SIZE D
lext

FOOTING 19mm (3/4 in) Ø20mm to Ø25mm 6d 12d


SLABS, BEAMS, COLUMNS, OTHERS 19mm (3/4 in) A
SLAB ON GRADE 25mm (1 in) 135 DEGREE HOOK - - LINTEL BEAM
VARIES
Ø10mm to Ø16mm 4d
1 - 16mmØ
3.WATER FOR MIXING SHALL BE CLEAN AND FREE FROM OIL, ALKALIS,
d

LARGER OF 6d &
ACIDS, ORGANIC MATERIALS WHICH MIGHT AFFECT THE PROPERTIES OF 75mm CONTINIOUS CHB
D
CONCRETE AND STEEL. Ø20mm to Ø25mm VERTICAL
6d
t

REINFORCEMENT
lex

4.ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN (7) DAYS
IMMEDIATELY AFTER POURING BY USING WET BURLAP, FOG SPRAYING OR DOOR
180 DEGREE HOOK OPENING CHB"t"
OTHER APPROVED METHOD. Ø10mm to Ø16mm 4d B
d

5.TESTING OF CONCRETE SHALL CONSIST OF COMPRESSIVE TESTS OF LARGER OF 6d & - -


MOLDED CONCRETE CYLINDERS FOR STRENGTH AND SLUMP TESTS FOR D 65mm SECTION C
lext Ø20mm to Ø25mm FFL
CONSISTENCY. 6d

CERTIFIED BY: PRC NO. 0164386 PROJECT TITLE: PROJECT OWNER: R.A. 9266, ART. IV SECT. 33 SHEET CONTENTS: REVISIONS SHEET NO.
RGA SQUARED CONSTRUCTION SERVICES PTR NO. 0000686 PROPOSED THREE (3) BEDROOM DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS DULY SIGNED,
C:\Users\ADRIAN\Downloads\Canva Design.png

Designer Contractor Fabricator REGIN ADRIAN Q. LANSANG, RCE


ISSUED ON JAN 24, 2023 TWO STOREY RESIDENTIAL MS. JECHENN D. CURA
STAMPED, OR SEALED, AS INSTRUMENT OF SERVICE, ARE THE INTELLECTUAL PROPERTY
AND DOCUMENTS OF THE ARCHITECT, WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS
EXECUTED OR NOT, IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE AS SHOWN
S
CIVIL ENGINEER
I CERTIFY THAT THIS WORK WAS PREPARED BY ME
CSFP
LOCATION: ADDRESS:
COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS
OR BUILDING, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN 1 4
Office Adress: #960 San Vicente, Guagua, Pampanga
OR DONE UNDER MY DIRECT SUPERVISION ISSUED AT Blue Heights Subdivision, Babo Sacan, Porac, Pampanga Calantas, Floridablanca, Pampanga
CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
GRID

TOP OF ROOF BEAM


3PCS EQUALLY
SPACED

50
10@100MM
A B C D E A B C D E
900 2305 3245 4250 900 2305 3245 4250

GB-1 GB-1

REST @ 200MM
5 5 C1 C1
C1
100MM THK. SLAB ON FILL WITH
Ø10MM TEMP. BARS SPACED @
2250

2250

GB-1
F1/C1 F1/C1 F1/C1
300MM ON CENTER BOTHWAYS

GB-1
4 4 GB-1

10@100MM
650

650
C1
750

750
F1/C1
3 F2/C2
3 C1 C2 4150
F2/C1

TENSION
CLASS B
900

GB-1

SPLICE
4150
2270

2270

GB-1
900
SECOND FFL

50
GB-1 C1 3PCS EQUALLY
2 F2/C1 F1/C1
2 C1 SPACED

50
GB-1

GB-1
GB-1
2080

2080
MAX SLOPE=1:6

10@100MM
GB-1 C1 GB-1 C1
1 F1/C1
1 C1
F2/C1 F2/C1

REST @ 200MM
10@100MM
FOUNDATION
2 GROUND FLOOR FRAMING PLAN
1 FOUNDATION PLAN S 2 NOT DRAWN TO SCALE GROUND FFL
S 2 NOT DRAWN TO SCALE
NGL
TOP OF GRADE BEAM

50
3PCS EQUALLY
SPACED

506@100MM 50
REFER TO SCHEDULE OF REFER TO SCHEDULE OF
MASONRY WALL MASONRY WALL
REFER TO SCHEDULE
OF MASONRY WALL
NGL NGL BOT. OF FOOTING
3 LAYERS

DOWELS TO MATCH 100mm THICK


OF CHB

3 LAYERS
OF CHB
CHB VERTICAL BARS SLAB ON FILL
DOWELS TO MATCH
4 TYP. COLUMNS ELEVATION DETAIL
250 300

300 300
300

250 300
CHB VERTICAL BARS DOWELS TO MATCH
TOP OF SLAB CHB VERTICAL BARS
S 2 NOT DRAWN TO SCALE
250

BOT. OF BOT. OF BOT. OF


FOOTING FOOTING FOOTING
Ø12mm@300mm OC LEVEL MARK TIES
400 Ø12mm@300mm OC Ø12mm@300mm OC SCHEDULE OF COLUMNS
150 400 150 400
WELL COMPACTED BASE 3-Ø12mm DIMENSION REINFORCEMENT
WELL COMPACTED BASE 5-Ø12mm WELL COMPACTED BASE 3-Ø12mm
SECTION
WF-1 AS SHOWN B H MAIN BAR
WF-2 WF-3 DIAMETER SET

3 TYP. WALL FOOTING DETAILS C1 200 400


H
6-Ø16 Ø10 1
S 2 NOT DRAWN TO SCALE B

FOOTING TO ROOF
SCHEDULE OF COLUMN FOOTINGS C2 200 400 H 8-Ø16 Ø10 1
DIMENSIONS REINFORCEMENTS
B
MARK WIDTH LENGTH THICK. DEPTH BOTTOM BARS TOP BARS REMARKS
(W) (L) (T) (D) ALONG "W" ALONG "L" ALONG "W" ALONG "L"
F1 1300 1300 300 1500 9-Ø16 9-Ø16 - - ECCENTRIC FOOTING
PC1 150 300 4-Ø16 Ø10 1
F2 1300 1300 300 1500 8-Ø16 8-Ø16 - - ISOLATED FOOTING

CERTIFIED BY: PRC NO. 0164386 PROJECT TITLE: PROJECT OWNER: R.A. 9266, ART. IV SECT. 33 SHEET CONTENTS: REVISIONS SHEET NO.
RGA SQUARED CONSTRUCTION SERVICES PTR NO. 0000686 PROPOSED THREE (3) BEDROOM DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS DULY SIGNED,
C:\Users\ADRIAN\Downloads\Canva Design.png

Designer Contractor Fabricator REGIN ADRIAN Q. LANSANG, RCE


ISSUED ON JAN 24, 2023 TWO STOREY RESIDENTIAL MS. JECHENN D. CURA
STAMPED, OR SEALED, AS INSTRUMENT OF SERVICE, ARE THE INTELLECTUAL PROPERTY
AND DOCUMENTS OF THE ARCHITECT, WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS
EXECUTED OR NOT, IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE AS SHOWN
S
CIVIL ENGINEER
I CERTIFY THAT THIS WORK WAS PREPARED BY ME
CSFP
LOCATION: ADDRESS:
COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS
OR BUILDING, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN 2 4
Office Adress: #960 San Vicente, Guagua, Pampanga
OR DONE UNDER MY DIRECT SUPERVISION ISSUED AT Blue Heights Subdivision, Babo Sacan, Porac, Pampanga Calantas, Floridablanca, Pampanga
CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
TORSION/WEB BARS(WHEN REQUIRED)
CL CL CL
SPLICE ZONE FOR LARGER OF LARGER OF SPLICE ZONE FOR LARGER OF
L1/4 TOP BARS L1/4 or L2/4 L1/4 or L2/4 TOP BARS L2/4 or L3/4

COVER
A B C D E EXTRA CONTINUOUS EXTRA CONTINUOUS EXTRA CONTINUOUS

SLAB t

GREATER OF db
STANDARD TOP BAR TOP BAR TOP BAR TOP BAR TOP BAR TOP BAR

or 25MM
HOOK
900 2305 3245 4250
TOP BARS
h
2B-2 2B-2

H
5 C1 C1
C1
WEB BARS
150mm(MIN.)
CONTINUOUS STIRRUPS 0.165L 0.165L CONTINUOUS EXTRA 0.165L 0.165L CONTINUOUS STANDARD
BOT. BARS
2250

BOTTOM BAR (REFER TO SCHEDULE) 2D 2D BOTTOM BAR BOTTOM BAR 2D 2D BOTTOM BAR HOOK

2B-3
2B-2
2B-1
2B-2

S2 S2 CLASS "A" CLASS "A"


EXTRA BOTTOM BAR
4 2B-1 TENSION SPLICE TENSION SPLICE

COVER
COVER COVER
L1 L2 L3

650
C1
750

2B-1 2B-1 B (EXTERIOR SPAN) (INTERIOR SPAN) (CANTILEVER SPAN)


3 C1 C2
2B-1

3
2B-2

S1 TYP. BEAM SECTION DETAIL 4 TYP. BEAM REBAR ARRANGEMENT DETAIL

2B-2
2270

S2

2B-2
S2
S 3 NOT DRAWN TO SCALE S 3 NOT DRAWN TO SCALE
2B-3
900
2B-1 2B-1 C1
2 C1
2B-2

SCHEDULE OF BEAMS
2B-2
2080

2B-2
2B-2

S2 S2 DIMENSION(MM) REBAR ARRANGEMENT STIRRUPS


LEVEL MARK
2B-2 C1 2B-2 2B-2 C3 B H BAR POSITION SUPPORT MID-SPAN SIZE SPACING (FROM SUPPORT FACE TO BEAM CENTER)
1 C1
EXTRA TOP BARS

G. FLOOR
TOP BAR 2-Ø16 2-Ø16

L/4 CONTINUOUS L/4 GB-1 200 300 WEB BAR - - Ø10 1@50MM, 10@100MM, REST@150MM
TOP BAR
BOTTOM BAR 2-Ø16 2-Ø16

h TOP BAR 3-Ø16 3-Ø16


2B-1 200 400 WEB BAR - - Ø10 1@50MM, 8@100MM, REST@150MM
150 150 BOTTOM BAR 3-Ø16 3-Ø16

SECOND FLOOR
GIRDER/MAIN CONTINUOUS EXTRA BOTTOM BAR GIRDER/MAIN TOP BAR 3-Ø16 2-Ø16
BEAM SUPPORT BOTTOM BAR STIRRUPS BEAM SUPPORT
(REFER TO SCHEDULE) 2B-2 200 400 WEB BAR - - Ø10 1@50MM, 8@100MM, REST@150MM
1 SECOND FLOOR FRAMING PLAN L
BOTTOM BAR 2-Ø16 3-Ø16
S 3 NOT DRAWN TO SCALE TOP BAR 2-Ø16 2-Ø16

5 TYP. SIMPLY SUPPORTEDBEAM REBAR ARRANGEMENT DETAIL 2B-3 200 350 WEB BAR - - Ø10 1@50MM, 8@100MM, REST@150MM
S 3 NOT DRAWN TO SCALE BOTTOM BAR 2-Ø16 2-Ø16
TOP BAR 3-Ø12 3-Ø12

ROOF
RB-1 150 300 WEB BAR - - Ø10 1@50MM, 10@100MM, REST@150MM

BOTTOM BAR 3-Ø12 3-Ø12


A B C D E
900 2305 3245 4250
CL CL CL CL CL CL
RB-1 RB-1
5 C1 C1
C1 L1/4
LARGER OFLARGER OF
L1/3 or L2/3 L1/3 or L2/3
LARGER OF
L1/3 or L2/3
TOP TEMP. BARS LARGER OF LARGER OF
LARGER OF
Ln2/4 or
B A C C Ln1/4 Ln1/4 or Ln2/4 Ln1/4 or Ln2/4 Ln3/4 or Ld Ld
2250

RB-1

RB-1

G H I
RB-1

J
RB-1

SLOPE
4 RB-1
150mm(MIN.) L1/8 L2/8 L2/8
650

C1
750

RB-1 RB-1 D E F
3 C1 C2 L1 L2
BOTTOM TEMP. BARS
150mm(MIN.) Ln1/8 Ln1/8 150mm(MIN.)
RB-1

(EXTERIOR SPAN) (INTERIOR SPAN) K L M


2270

RB-1

NOTES: Ln1 Ln2 Ln3


900 L1 L2 L3
1.TOP CONTINUOUS BARS SHALL BE SPLICED ONLY AT THE MID-SPAN
USING CLASS "B" TENSION SPLICE. (EXTERIOR SPAN) (INTERIOR SPAN) (CANTILEVER SPAN)
RB-1 RB-1 C1
2 C1 2.BOTTOM CONTINUOUS BARS SHALL BE SPLICED ONLY AT THE
RB-1

SUPPORT USING CLASS "B" TENSION SPLICE.


TYP. TWO WAY SECTION
RB-1

RB-1
2080

RB-1

TYP. SECTION
RB-1 C1 RB-1 RB-1 C1
1 C1
TWO WAY SLAB SCHEDULE
ONE WAY SLAB SCHEDULE MAIN REINFORCEMENT TEMPERATURE BARS
MAIN REINFORCEMENT TEMPERATURE BARS
MARK THICKNESS SHORT SPAN LONG SPAN
MARK THICKNESS SHORT SPAN LONG SPAN TOP BOTTOM
TOP BOTTOM BOTTOM BARS TOP BARS BOTTOM BARS TOP BARS
BOTTOM BARS TOP BARS BOTTOM BARS TOP BARS
S2 100 Ø10@200 Ø10@200 Ø10@200 Ø10@200 Ø10@400 -
S1 100 Ø10@200 Ø10@200 - - Ø10@400 Ø10@400
S3 100 Ø10@400 Ø10@400

6 TYP. ONE WAY SLAB DETAIL 7 TYP. TWO WAY SLAB DETAIL
S 3 NOT DRAWN TO SCALE
S 3 NOT DRAWN TO SCALE
2 ROOF BEAM FRAMING PLAN
S 3 NOT DRAWN TO SCALE

CERTIFIED BY: PRC NO. 0164386 PROJECT TITLE: PROJECT OWNER: R.A. 9266, ART. IV SECT. 33 SHEET CONTENTS: REVISIONS SHEET NO.
RGA SQUARED CONSTRUCTION SERVICES PTR NO. 0000686 PROPOSED THREE (3) BEDROOM DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS DULY SIGNED,
C:\Users\ADRIAN\Downloads\Canva Design.png

Designer Contractor Fabricator REGIN ADRIAN Q. LANSANG, RCE


ISSUED ON JAN 24, 2023 TWO STOREY RESIDENTIAL MS. JECHENN D. CURA
STAMPED, OR SEALED, AS INSTRUMENT OF SERVICE, ARE THE INTELLECTUAL PROPERTY
AND DOCUMENTS OF THE ARCHITECT, WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS
EXECUTED OR NOT, IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE AS SHOWN
S
CIVIL ENGINEER
I CERTIFY THAT THIS WORK WAS PREPARED BY ME
LOCATION: ADDRESS:
COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS
OR BUILDING, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN 3 4
Office Adress: #960 San Vicente, Guagua, Pampanga
OR DONE UNDER MY DIRECT SUPERVISION ISSUED AT CSFP Blue Heights Subdivision, Babo Sacan, Porac, Pampanga Calantas, Floridablanca, Pampanga
CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
APO EPR 0.5mm THK. OR EQUIVALENT W/
50MM X 100MM X1.5MM THK. TUBULAR RAFTERS 5MMDOUBLE SIDED ALUMINUM FOAM INSULATION
FIRE WALL

C-PURLINS @ 600mm O.C


50MM X 75MM X1.2MM THK.

400

563
1125
551

562
RB-1 RB-1
RB-1

300
ELEV. 6.2M RB-1
RB-1

2 TYP. ROOF SECTION 50MM X 75MM X1.2MM THK.


S 4 SCALE: 1: 50 C-PURLINS
APO EPR 0.5mm THK. OR EQUIVALENT W/ 5MM
DOUBLE SIDED ALUMINUM FOAM INSULATION

30MM X 30MM X 1.5MM THK


ANGULAR CLEAT (FULL WELD)
1000 1000

50MM X 100MM X 1.5MM THK TUBULAR

3 TYP. PURLIN CONNECTION DETAIL


600600 S 4 SCALE: 1:10
50MM X 75MM X1.2MM THK. C-PURLINS

1 ROOF FRAMING PLAN


S 4 NOT DRAWN TO SCALE

SECOND FFL

Ø10 @ 100MM O.C.


BOTHWAYS

1600
Ø10 @ 100MM O.C.

LANDING
Ø10 @ 100MM O.C.
COMPACTED
SAND

900
GROUND FFL

4 TYP. STAIR SECTION


S 4 SCALE: 1: 30

CERTIFIED BY: PRC NO. 0164386 PROJECT TITLE: PROJECT OWNER: R.A. 9266, ART. IV SECT. 33 SHEET CONTENTS: REVISIONS SHEET NO.
RGA SQUARED CONSTRUCTION SERVICES PTR NO. 0000686 PROPOSED THREE (3) BEDROOM DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS DULY SIGNED,
C:\Users\ADRIAN\Downloads\Canva Design.png

Designer Contractor Fabricator REGIN ADRIAN Q. LANSANG, RCE


ISSUED ON JAN 24, 2023 TWO STOREY RESIDENTIAL MS. JECHENN D. CURA
STAMPED, OR SEALED, AS INSTRUMENT OF SERVICE, ARE THE INTELLECTUAL PROPERTY
AND DOCUMENTS OF THE ARCHITECT, WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS
EXECUTED OR NOT, IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE AS SHOWN
S
CIVIL ENGINEER
I CERTIFY THAT THIS WORK WAS PREPARED BY ME
LOCATION: ADDRESS:
COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS
OR BUILDING, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN 4 4
Office Adress: #960 San Vicente, Guagua, Pampanga
OR DONE UNDER MY DIRECT SUPERVISION ISSUED AT CSFP Blue Heights Subdivision, Babo Sacan, Porac, Pampanga Calantas, Floridablanca, Pampanga
CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
12000 11000 12000 11000
7850 4150 6850 4150 7850 4150 6850 4150
1000 4950 1900 2675 1500 2675 1000 4950 1900 2675 1500 2675

W.S

1200 950
1200 950
WATER 20mm PPR WATERLINE PIPE CB S.S
1500

1500
20mm PPR WATERLINE PIPE

TANK

2150
2150

2150

2150
SHO. SHO.

6 " Ø PVC WASTE LINE


LAV. LAV.
W.C CV W.C F.D F.D
M

3200
3200

3200

3200
H.B
SINK GV W.C SINK W.C
RISER
4400

4400
20mm PPR WATERLINE PIPE LAV. 20mm PPR WATERLINE PIPE LAV. C.O
1700

1700
C.O
H.B SHO. SHO.

2296

2296
LAV. LAV.
W.C CB W.C

4 " Ø PVC SOIL LINE


7550

7550

7550

7550
1200

1200

1200

1200
3400

3400
F.D F.D
CB
F.D
10550

10550

10550

10550
LAV.

4350

4350
3150

3150

3150
3150
3104

3104
2000

2000
H.B
H.B

20mm PPR WATERLINE PIPE


LAV.

5000

5000
CB

DIGESTIVE
CHAMBER
6 " Ø PVC WASTE LINE
3000

3000

3000
3000
LEACHING
CESSPOOL
WELL

CONNECT TO
CV STREET DRAINAGE
CONNECT TO
M
STREET DRAINAGE
GV
FROM MAIN
2000 2400 3450 4150 WATER SOURCE 1000 2400 3300 4300 2000 2400 3450 4150 1000 2400 3300 4300
12000 11000 12000 11000

P WATERLINE LAYOUT (GF) P WATERLINE LAYOUT (2F) P SEWERLINE LAYOUT (GF) P SEWERLINE LAYOUT (2F)
1 SCALE: 1:100 MTS. 2 SCALE: 1:100 MTS. 5 SCALE: 1:100 MTS. 6 SCALE: 1:100 MTS.

11000 11000
6850 4150 6850 4150
2675 1500 2675 2675 1500 2675 D.S

D.S VSTR.
WATER WATER D.S
1200 950

1200 950
20mm PPR WATERLINE PIPE TANK 20mm PPR WATERLINE PIPE TANK
20mm D.S S.D
SHO. PPR
2150

2150
WAT
SHO. SHO. W.C
ERLIN
E PIP W.C
LAV. E
LAV. 6"Ø
PVC
3200

3200

WAS
W.C W.C TE L
INE
LAV. 20mm PPR WATERLINE PIPE LAV. 20mm PPR WATERLINE PIPE
LAV. LAV.
W.C CB W.C
PIPE
SHO.
INE S.D
ERL
R WAT TUB
m PP CB
SHO. SHO. 20m F.D
2296

2296
LAV. LAV.
W.C W.C SINK CB SINK
7550

7550

7550

7550
1200

1200

SINK SINK
HB. W.C WATER
W.C TANK
H.B
CB
6"Ø
PVC INE
WAS OIL L
4350

4350

TE L
INE Ø PVC S
4"

M
CONNECT TO
CV
3150

3150
3104

3104
GV STREET DRAINAGE
H.B E PIPE
RLIN
ATE
RW
m PP
20m

M
CV CONNECT TO
GV STREET DRAINAGE
FROM MAIN
WATER SOURCE

1000 2400 3300 4300 1000 2400 3300 4300


11000 11000

P WATERLINE LAYOUT (COLD) P WATERLINE LAYOUT (HOT) P WATERLINE LAYOUT (ISO) P SEWERLINE LAYOUT (ISO)
3 SCALE: 1:100 MTS. 4 SCALE: 1:100 MTS. 7 SCALE: 1:100 MTS. 8 SCALE: 1:100 MTS.

CERTIFIED BY: PRC NO. 0010084 PROJECT TITLE: PROJECT OWNER: R.A 9266, ART. IV SEC. 33 SHEET CONTENT: REVISIONS: SHEET NO.
RGA SQUARED CONSTRUCTION SERVICES PTR NO. 9516645 PROPOSED TWO (2) STOREY
Designer Contractor Fabricator LOUIE G. SERRANO, RMP
ISSUED ON: 01-03-2023 THREE (3) BEDROOM RESIDENTIAL
Ms. Jechenn D. Cura Drawings and specifications and other contract documents duly signed, stamped of sealed, as instruments
of service, are the intellectual property and documents of the architect, whether the object for which they are
made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents
AS SHOWN
P
MASTER PLUMBER for use in the repetition of and for other projects or buildings, whether executed partly or in whole, without the
I CERTIFY THAT THIS WORK IS DONE BY ME OR LOCATION: ADDRESS: written consent of architect or author of said documents. 1 2
Office Adress: #960 San Vicente, Guagua, Pampanga I CERTIF THAT THIS WORK WAS PREPARED BY ME
DONE UNDER
OR DONE UNDER MYMYDIRECT
DIRECT SUPERVISION
SUPERVISION ISSUED AT: CSFP Babo Sacan, Porac, Pampanga Calantas, Floridablanca, Pampanga
GENERAL NOTES: LEGEND:
SYMBOL DESCRIPTION
ALL PLUMBING INSTALLATIONS AS
WELL AS M
WATER METER
OTHER SANITARY FACILITIES SHALL 2300

CONFORM GATE VALVE 800 1500


MANHOLE MANHOLE
WITH THE PLUMBING CODE, NATIONAL 10mm Ø BARS
CHECK VALVE @ 0.20 M.O.C BW.

300
BLDG. AIR SPACE 100mm Ø PVC
CODE OF THE PHILIPPINES AND OTHER KS KITCHEN SINK
INLET PIPE

700
100mm Ø PVC 10mm Ø HOR.
RULES AND REGULATIONS ENFORCED

1600
OUTLET PIPE LEACHING DIGESTIVE BARS EVERY 3RD

1100
IN THE LOCALITY. LAV LAVATORY CHAMBER

1400
WELL LAYER OF CHB
100mm Ø PVC
FD FLOOR DRAIN OUTLET PIPE 10mm Ø VER.

700
BARS EVERY 3RD

200
100mm Ø PVC LAYER OF CHB
ALL MATERIALS AND FIXTURES TO BE SHO SHOWER INLET PIPE 17

USED PLAN SECTION


WS WASTE STACK
SHALL BE NEW AND OF APPROVED
TYPE SS SOIL STACK
ACCORDING TO ITS USE AND PURPOSE P SEPCTIC VAULT DETAILS
. COLD WATER 1 SCALE: N.T.S

HOT WATER
WATER SUPPLY LINES SHALL BE
400
EMBEDDED SOIL PIPE
AT DEPTH OF 0.75m TO 1.25m FROM
THE VSTR VENT STOCK THRU ROOF 10mm Ø VERT.
& HOR. BARS
FINISHED FLOOR LINE.

400
OUT IN
100mm Ø DP 100mm Ø DP
ALL INSTALLED PIPES SHALL BE
4" THK. CHB
TESTED
BEFORE POURING CONCRETE OR PLAN
BACK
FILLING TO COVER SAID PIPES.

ALL EXPOSED SURFACE FITTINGS AND 4" THK. CHB


TRIMMINGS SHALL BE CLEANED, FREE IN

FROM GREASE AND POLISHED. OUT

100mm Ø DP SLAB 100mm Ø DP

ALL PLUMBING TESTS SHALL BE DONE SECTION


UNDER THE SUPERVISION OF AN
ARCHITECT, ENGINEER OR A P CATCH BASIN DETAILS
MASTER PLUMBER. 2 SCALE: N.T.S

CERTIFIED BY: PRC NO. 0010084 PROJECT TITLE: PROJECT OWNER: R.A 9266, ART. IV SEC. 33 SHEET CONTENT: REVISIONS: SHEET NO.
RGA SQUARED CONSTRUCTION SERVICES PTR NO. 9516645 PROPOSED TWO (2) STOREY
Designer Contractor Fabricator LOUIE G. SERRANO, RMP
ISSUED ON: 01-03-2023 THREE (3) BEDROOM RESIDENTIAL
Ms. Jechenn D. Cura Drawings and specifications and other contract documents duly signed, stamped of sealed, as instruments
of service, are the intellectual property and documents of the architect, whether the object for which they are
made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents
AS SHOWN
P
MASTER PLUMBER for use in the repetition of and for other projects or buildings, whether executed partly or in whole, without the
I CERTIFY THAT THIS WORK IS DONE BY ME OR DONE UNDER MY LOCATION: ADDRESS: written consent of architect or author of said documents. 2 2
Office Adress: #960 San Vicente, Guagua, Pampanga DIRECT SUPERVISION ISSUED AT: CSFP Babo Sacan, Porac, Pampanga I CERTIF THAT THIS WORK WAS PREPARED BY ME
Calantas,
OR DONE UNDER MY DIRECT SUPERVISION
Floridablanca, Pampanga

You might also like