PROJET
PROJET
PVsyst TRIAL
PVsyst - Simulation report
Grid-Connected System
Project: Menakao
Variant: Nouvelle variante de simulation
No 3D scene defined, no shadings
System power: 87.5 kWp
PVsyst TRIAL
Ambohidratrimo - Madagascar
PVsyst TRIAL
PVsyst TRIAL
Author
PVsyst TRIAL
Project: Menakao
Variant: Nouvelle variante de simulation
PVsyst V7.3.4
VC0, Simulation date:
02/05/23 11:58
PVsyst TRIAL
with v7.3.4
Project summary
Geographical Site Situation Project settings
Ambohidratrimo Latitude -18.82 °S Albedo 0.20
Madagascar Longitude 47.44 °E
Altitude 1292 m
Time zone UTC+3
Meteo data
Ambohidratrimo
Meteonorm 8.1 (1981-2000), Sat=100 % - Synthétique
System summary
PVsyst TRIAL
Grid-Connected System No 3D scene defined, no shadings
System information
PV Array Inverters
Nb. of modules 162 units Nb. of units 3 units
Pnom total 87.5 kWp Pnom total 81.0 kWac
Pnom ratio 1.080
Results summary
Produced Energy 167167 kWh/year Specific production 1911 kWh/kWp/year Perf. Ratio PR 85.66 %
PVsyst TRIAL
Project and results summary
Main results
Loss diagram
Predef. graphs
Table of contents
PVsyst TRIAL
PVsyst TRIAL
02/05/23 PVsyst Evaluation mode Page 2/9
Project: Menakao
Variant: Nouvelle variante de simulation
PVsyst V7.3.4
VC0, Simulation date:
02/05/23 11:58
PVsyst TRIAL
with v7.3.4
General parameters
Grid-Connected System No 3D scene defined, no shadings
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 10 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
PVsyst TRIAL
PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model JAM72-S30-540-MR Model ECO 27.0-3-S
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 540 Wp Unit Nom. Power 27.0 kWac
Number of PV modules 162 units Number of inverters 3 units
Nominal (STC) 87.5 kWp Total power 81.0 kWac
Modules 9 Strings x 18 In series Operating voltage 580-850 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.08
Pmpp 80.3 kWp
U mpp 679 V
I mpp 118 A
PVsyst TRIAL
Total PV power Total inverter power
Nominal (STC) 87 kWp Total power 81 kWac
Total 162 modules Number of inverters 3 units
Module area 418 m² Pnom ratio 1.08
Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 94 mΩ Loss Fraction -0.8 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst TRIAL
Incidence effect (IAM): User defined profile
PVsyst TRIAL
02/05/23 PVsyst Evaluation mode Page 3/9
Project: Menakao
Variant: Nouvelle variante de simulation
PVsyst V7.3.4
VC0, Simulation date:
02/05/23 11:58
PVsyst TRIAL
with v7.3.4
Main results
System Production
Produced Energy 167167 kWh/year Specific production 1911 kWh/kWp/year
Perf. Ratio PR 85.66 %
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
February 187.2 61.44 21.29 185.4 181.9 13949 13652 0.842
March 188.1 66.16 21.02 193.9 190.3 14675 14364 0.847
April 171.2 53.20 19.84 184.4 182.2 14082 13784 0.854
May 147.3 44.37 17.75 165.9 163.5 12932 12656 0.872
June 128.0 41.17 15.07 146.2 143.9 11518 11270 0.881
July 136.1 43.33 14.24 154.2 151.8 12174 11912 0.883
August 159.7 51.36 15.46 174.8 172.5 13661 13369 0.874
September 187.1 52.50 17.25 197.1 194.2 15142 14821 0.860
October 206.0 66.64 19.68 207.9 205.0 15797 15463 0.850
November 211.5 69.67 20.81 206.3 203.1 15592 15263 0.846
December 224.5 72.45 21.54 215.0 211.0 16180 15838 0.842
Year 2153.2 706.71 18.76 2230.7 2195.4 170797 167167 0.857
PVsyst TRIAL
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings
PVsyst TRIAL
02/05/23 PVsyst Evaluation mode Page 4/9
Project: Menakao
Variant: Nouvelle variante de simulation
PVsyst V7.3.4
VC0, Simulation date:
02/05/23 11:58
PVsyst TRIAL
with v7.3.4
Loss diagram
2153 kWh/m² Global horizontal irradiation
+3.6% Global incident in coll. plane
PVsyst TRIAL
-0.74% PV loss due to irradiance level
PVsyst TRIAL
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
167167 kWh Available Energy at Inverter Output
167167 kWh Energy injected into grid
PVsyst TRIAL
PVsyst TRIAL
02/05/23 PVsyst Evaluation mode Page 5/9
Project: Menakao
Variant: Nouvelle variante de simulation
PVsyst V7.3.4
VC0, Simulation date:
02/05/23 11:58
PVsyst TRIAL
with v7.3.4
Predef. graphs
Diagramme d'entrée/sortie journalier
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
02/05/23 PVsyst Evaluation mode Page 6/9
Project: Menakao
Variant: Nouvelle variante de simulation
PVsyst V7.3.4
VC0, Simulation date:
02/05/23 11:58
PVsyst TRIAL
with v7.3.4
PVsyst TRIAL
P90 157.95 MWh
P95 155.35 MWh
Probability distribution
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
02/05/23 PVsyst Evaluation mode Page 7/9
PVsyst V7.3.4
VC0, Simulation date:
02/05/23 11:58
with v7.3.4
Project: Menakao
Variant: Nouvelle variante de simulation
PVsyst V7.3.4
VC0, Simulation date:
02/05/23 11:58
PVsyst TRIAL
with v7.3.4
PVsyst TRIAL
System Lifecycle Emissions Details
PVsyst TRIAL
Inverters 0.00 kgCO2/ 3.00 0.00
PVsyst TRIAL
PVsyst TRIAL
02/05/23 PVsyst Evaluation mode Page 9/9