ERROR CODES

Error Codes
SIGMA FAMILY
Disconnect external keypad and power up the
9 KEYBOARD FAULT
machine, if fault disappears check keypad/loom -
replace keypad.
If problem persists then replace processor board.

Ensure there are cups present within the


11 CUPS SOLD OUT motorised cup unit.
OR SWITCH Ensure the cup switches in the cup unit both work
DAMAGED correctly.

Empty and replace the overflow bucket - make sure


12 WASTE OVERFLOW
the brass pressure weight is inside the bucket.
BUCKET IS FULL
To reset the machine - power down for 10 seconds,
then turn back on using the rocker switch

Check the water has not been turned off at the stop
13 BOILER PROBE
cock.
SET HAS NOT
Check water supply to inlet valves is no less than
DETECTED WATER
20PSI.
AFTER 3 MINUTE
Are there appliances near by draining the water
TIME OUT
pressure?
Ensure the probe set terminals are a tight fit on top
of the boiler lid.
Check continuity from the probe set to the
processor on all terminals and plugs.
Check for scale obstructing the fill level probe
inside the boiler. De-scale if necessary.
Replace the probe set.

Check the machine for internal water leak.


20 WATER FAIL SAFE
Check for scale obstructing the probe set inside the
boiler. De-scale if necessary.
Fault code will be rectified by interrupting power.

Check boiler for leaks.


21 LEAK DETECTED/
Check boiler valves for scale and replace if
BOILER/VALVE
necessary.
LEAK DETECTION
Check / replace the main water inlet valves.
Check the leak detect value in software is correct.
Check for scale obstructing the fill level probe
inside the boiler - de-scale if necessary.
Check boiler for scale. De-scale if necessary.
Follow the guidance under Error-13 - both errors are
similar
Error Codes The dispense arm has not moved or activated the
30 DISPENSE ARM
switch within the time set (5 seconds)
JAM TIME-OUT
Check the condition of the switches and the
ACTIVATED
dispense arm motor.
Replace if necessary

50 BREWER 1 FAULT Check the brewer micro-switch is homing correctly.

52 BREWER 2 FAULT Check the brewer micro-switch is homing correctly.

The processor detects signals from the boiler probe


56 BOILER FULL &
set that indicate that the boiler is both empty& full
EMPTY
at the same time.
Ensure the probe set is free from scale.
Replace boiler probe set.

Ensure machine is level.


57 BOILER
Ensure probes are connected and fitted to the boiler
OVERFLOW
lid.
Ensure the boiler lid is fitted to the boiler and all
gaskets are in place.
Ensure the probe set is free from scale.

Ensure the connectors are fitted correctly.


58 BOILER UNDER
Check / replace the boiler fuse.
TEMPERATURE
This fault will also show if there is no water to the
machines.

TEMPERATURE Ensure the probe connectors are fitted correctly.


59 THERMISTOR Ensure the probe is connected to the control board.
OPEN CIRCUIT Replace boiler probes.

BEAN GRINDER Ensure Grinder is connected.


60 TIME-OUT Ensure the Grinder fuse is fitted.
Ensure no objects are jammed in the Grinder.

DRIVE MOTOR NOT Ensure the brewer is mounted correctly in the


61 REACHING HOME machine.
WITHIN THE TIME- Ensure the connectors are fitted correctly.
OUT SET Replace the drive motor for the brewer.

FAULT GENERATED Check the EVA DTS code - this will be displayed
84 BY A BILL READER within their fault log.
Downloads available from:
www.vending-europe.eu/standards/EVA-DTS.html
Error Codes
ESPRESSO BREWER ERROR CODES
32 BREWER 1 NO FLOW

33 BREWER 2 NO FLOW

34 BREWER 1 SLOW FLOW

35 BREWER 2 SLOW FLOW

36 BREWER 1 DOSER FLOW

37 BREWER 2 DOSER FLOW

38 HIGH PRESSURE BOILER LEAK

41 BREWER 1 CHAMBER REMOVED WITH DOOR CLOSED

42 BREWER 2 CHAMBER REMOVED WITH DOOR CLOSED

43 HIGH PRESSURE BOILER NO FILL

44 HIGH PRESSURE UNDER TEMPERATURE

45 HIGH PRESSURE BOILER TEMPERATURE SENSOR FAIL

46 HIGH PRESSURE BOILER LEVEL SENSOR FAIL

62 BREWER 1 24V LOST

63 BREWER 2 24V LOST

67 BREWER 1 PCB OVER - TEMPERATURE

68 BREWER 2 PCB OVER - TEMPERATURE


Error 14 Triac /
Circuit Failure
14 - 20 TRIAC ERROR

You may see this more than once on


your Sigma LCD display.

The error code 14 represents a circuit failure - Nothing more. The number after the
hyphen represents the circuit with the issue/problem.

14- 20 on a Sigma would mean you have a problem with Whipper Station 1. Possible
whipper issues could include:

The operator has fitted the impellor incorrectly - Most Common


The fuse has then blown - very likely
The whipper base seal has worn - common
The whipper motor is faulty - rare
The terminal and crimps to the motor are loose / disconnected - rare
An engineer, operator or a site service engineer has decided to fit a higher rated
fuse to protect the whipper motor circuit which has damaged the main cabinet
loom and processor - extremely rare
Triac Machine Layout
& Circuit Table
In the event of a circuit failure the 14 represents an open circuit, the number after
the hyphen represents the circuit with the fault. The table below allows you to
pinpoint the component with the fault for example: 14-20 would be an open circuit
regarding the Whipper Station 1.
DO NOT FIT A DIFFERENT TYPE OF FUSE RATING OTHER THAN THE FUSES
SPECIFIED IN THE FOLLOWING TABLE...
Fuse Fuse
T3.15 Amp T2.0 Amp

PN: 1025002 PN: 1025001

Fuse
T5.0 Amp

PN: 1025007