Agilent BioTek Synergy H1 Brochure-Final
Agilent BioTek Synergy H1 Brochure-Final
Microplate Reader
Designed for flexibility and performance
Agilent BioTek Synergy H1
Microplate Reader
2
" Agilent BioTek's Synergy H1 is an easy to use instrument that
allows flexibility of assays and analysis. The customer support
team and local rep have always been highly responsive to our
lab's needs."
– Kate Mueller,
University of MN
3
"It is very effective equipment for all the assays using absorbance quantification methods. High
sensitivity and reproducibility to detect samples. This equipment is very easy to use and came with
a reasonable pricing and a good after-sales care."
– Lufen Chang
City of Hope National Medical Center and
Beckman Research Institute Department of
Cancer Genetics and Epigenetics
Automated Z-focus—best
performance with all plate types
Without automated Z-focus available
(1), performance at low volumes is
affected. With automated Z-focus (2),
reading height is precisely adjusted for
best performance in all plate types and
all volumes.
4
Agilent BioTek Synergy H1
Synergy H1 now offers continuously
variable bandwidth monochromators
for fluorescence excitation and
emission wavelength selection; the
fluorescence bandwidth can be
set between 9 and 50 nm, in 1 nm
increments, allowing users to fully
optimize reader settings to drive the
best assay performance compared to
fixed-bandwidth systems.
5
Applications
ELISA Luciferase reporter assays
ELISA methods with colorimetric, fluorescent, and luminescent substrates Luciferase-based reporter assays measure luminescent signal. This
are easily detected with Synergy H1. enables users to quantify the activity of factors that affect particular
signaling pathways.
Nucleic acid and protein quantification assays can be executed by Microbial growth assays including yeast and bacteria, for example, can be
spectrophotometric or fluorescent determination with Synergy H1, in measured by several methods, including turbidimetric measurements with
microplates or in microvolumes with the Take3 microvolume plate. Synergy H1.
cAMP assay
2500
2000
TR-FRET ratio
1500
1000
500
0
1.0E-11 1.0E-10 1.0E-09 1.0E-08 1.0E-07 1.0E11
[cAMP]
Time-resolved fluorescence energy transfer (TR-FRET) and homogeneous Fluorescence polarization is widely used in research labs to study mo-
time-resolved fluorescence (HTRF) are sensitive, robust methods. Synergy lecular binding or dissociation events, and in screening labs to screen
H1 and Gen6 provide excellent sensitivity for optimal Z-factors. for drug candidates.
6
Bioluminescence resonance energy transfer Enzyme kinetics
Lineweaver-Burke plot
0.30
Protein X Protein Y 0.25
0.20
0.15
1/ V
NanoLuc HN HT 0.10
0.05
+ substrate
0.00
-5 -4 -2 0 2 4 5 6 10 12 14
Fluorescence 1/ [ S ]
Bioluminescence resonance energy transfer (BRET) proximity assays Enzyme reaction rates can easily be measured with Synergy H1. Gen6
enable detailed investigations of protein—protein interactions. BRET is data analysis software has built-in protocols for kinetic reactions.
easily detected with Synergy H1.
Add
Protein ProteoStat Protein
Dye
fibril aggregate
Synergy H1 has a robust shaking mechanism needed to quantify protein Cell-based assays assess critical characteristics such as viability, toxicity,
aggregation and amyloid formation via kinetic fluorescent measurements proliferation, and cell death.
of thioflavin T.
Oxygen consumption
signal change H2DCFDA
(Non-fluorescent)
ROS
Time
DCF
(Fluorescent)
Use Agilent MitoXpress and pH-Xtra kits to measure real-time metabolic The formation of Reactive Oxygen Species (ROS) can be measured with
markers such as Oxygen Consumption Rates (OCR) and Extracellular the use of fluorescent probes in the Synergy H1.
Acidification Rates (ECAR).
7
Peripherals
8
Peripherals
CO2/O2 controller
The compact gas controller maintains control of CO2 and O2 levels in the
Synergy H1 to support live cell assays.
Dual-reagent injector
The dual-reagent injector module enables fast inject/read processes. Angled
injector tips protect cell monolayers from shear stress during injection.
9
10
Agilent BioTek Synergy H1
Technical Details
General
Wavelength Selection Monochromators for fluorescence intensity, UV-Vis absorbance, and luminescence
Filters for fluorescence intensity, time-resolved fluorescence, fluorescence polarization, and filtered luminescence
Environmental Controls 4-Zone Incubation to 70 °C ("M2" configurations) or 45 °C, with Condensation Control; CO2/O2 controller available
Modularity and Configurability Synergy H1 has many available configurations; detection modules and peripherals can be added as laboratory
needs change
11
Learn more and buy online:
www.agilent.com/lifesciences/biotek
Europe
[email protected]
Asia Pacific
[email protected]
DE03489872