DataStickTM Measurement System

Universal Plug & Play • Dir ect PLC Connections • Remote Configuration

D.O. DataStickTM

D.O. • Clark Cell technology


• Pre-calibrated (no field calibration required)
• Plug & play sensor heads
• Rugged, foul resistant membrane
• Electrode protection options
• Simple membrane cartridge replacement
• Direct data reporting
• Plug & play industrial communications adapters

Connect this D.O. sensor directly to a PLC for


seamless integration with industrial control
systems. Use any computer to display data,
calibrate and customize the measurement
without an intermediate analyzer electronics
box. Sensor heads are pre-calibrated and can
be replaced or exchanged with any other type
of sensor without taking the system down.
Save space, time and money.

DataStickTM Analytical System


interchangeable communication adapters interchangeable sensor heads
AV38 Local Display
(4-20 mA and Relays)
PLC
TOROIDAL
PLD
PDA MODBUS

PC RESISTIVITY
PC
USB/RS-232
SCADA CONDUCTIVITY
universal sensor module
RS-485
OZONE

DCS
PROFIBUS ORP

MODBUS DO
PLC
Other measurements and
communication adapters
pH available upon request
DEVICENET
DEVICENET
page 2 DS-DO-02 (3/2006)

D.O. DataStickTM Data Sheet

Construction
Process Electrodes: Gold Cathode, Silver Anode,
Silver Reference
(3 Electrode Polarographic Clark Cell)
Membrane: FEP Teflon
O-Rings: Viton® (other materials available)
Sensor Head Material: PEEK®, Ryton® or CPVC
DataStick Material: 316 Stainless Steel, PEEK®,
Ryton® or CPVC
Weight: 1.2 lbs (PEEK®, Ryton® or CPVC)
2.6 lbs (316 Stainless Steel)

Units of Measure
Measurement Units: ppm, mg/l, %
Temperature Units: °C, °F
Mounting adapters, junction boxes
and recharge kits are available
Calibration
Air: Automatically adjusts for set
Measurement System Performance pressure
Range: 0 to 40 ppm Sample: 1 point
Resolution: 0.01 ppm Zero: 1 point
Accuracy: 0.04 ppm Temperature: 1 and 2 point
Step Response Time: 90% in 90 seconds Note: D.O. and temperature are precalibrated at the factory
Note: Typical at 25°C
Performance unaffected by cable length
Compensation Options
Salinity: 0 mS/cm to 999.9 mS/cm
Operational Environment
PEEK® or RYTON® CPVC Pressure: 539.2 mmHg to 792.4 mmHg
Sensor Head Sensor Head
Temperature: Automatic from -5°C to 50°C
Temperature Range: -5°C to 50°C -5°C to 50°C
Maximum Pressure: 150 psig @ 50°C 85 psig @ 50°C
Other Configuration Options
Maximum Flow Rate: 10 ft/second 10 ft/second Sensor Filter: 0 to 100 seconds
Temperature Filter: 0 to 100 seconds
Power Requirements
Voltage Range: 10 to 30 VDC
Approvals and Ratings
Maximum Power: 200 mW Immunity & Emissions: CE (EN61326 and EN61326:1998)
Typical Power: 120 mW Safety: CE (EN 61010-1)
Note: Class II DC power supply required UL 508
Hazardous Locations: UL Class I, Division 2

AquaSensorsTM reserves the right to change product specifications at any time. All prices subject to change. Inquire about volume discounts.

www.aquasensors.com
page 3 DS-DO-02 (3/2006)

D.O. DataStickTM Ordering Information System Part Number: S / CA-b-nw-x-y / DS-b-t / DO-b-t-x-y-z

Communications Adapter DataStickTM D.O. Sensor Head

Plugs into the DataStickTM to provide power Provides universal conversion of sensor signals Dissolved Oxygen Sensor Head. Precalibrated
and direct interactive communications with and interactive communications for for D.O. and temperature. Can be plugged into
control systems. measurement, calibration, configuration and any DataStickTM to yield accurate 24-bit data.
diagnostics.

Part Number: CA-b-nw-x-y Part Number: DS-b-t Part Number: DO-b-t-x-y-z

Body Material Body Material Body Material


316 Stainless Steel b=1 316 Stainless Steel b=1 CPVC b=2
CPVC b=2 CPVC b=2 PEEK® b=3
PEEK® b=3 PEEK® b=3 Ryton® b=4
Ryton® b=4 Ryton® b=4 Electrode Type
Communications Mounting Gold/Silver t=1
RS-232 ASCII nw=1A 1 inch NPT front/back t=1 Sensor Tip
RS-485 ASCII nw=1B 1 inch NPT front only t=2 Protected x=A
Modbus RTU nw=2B 1 inch Tri-clamp t=3 Flat x=B
Modbus RS-232 nw=2A 2 inch Tri-clamp t=4 Filling Solution
DF1 RS-232 nw=3A 3 inch Tri-clamp t=5 Standard y=1
DF1 RS-485 nw=3B 4 inch Tri-clamp t=6 Custom y=2
Ethernet nw=7R Custom Mounting t=8 Membrane
DeviceNet nw=5R FEP Teflon z=A
Profibus DP nw=6R Custom z=B
USB nw=8R
Cable Length
10 feet x=1
20 feet x=2
30 feet x=3
Custom x=4
Cable Termination
Stripped Wires y=A
Connector y=B
Custom y=C

A CCE S S OR IES & R EPL ACEM EN T PAR TS

D.O. Membrane D.O. Solutions Local Display Interface


Replacements 500 ml bottles AV38: 1/4 DIN,
DMR01: Ryton Protected RDOK1: Membrane Electrolyte Outputs, Relays, Digital
DMR02: Ryton Flat ZDOKO: Zero Powder Communications
DMR03: PEEK Protected Wash Adapters Options
DMR04: PEEK Flat MH1142: air purge, CPVC
MH1132: water purge, CPVC

SBC01: Storage cap


with sponge
page 4 DS-DO-02 (3/2006)

DataStickTM Mounting Hardware

1 Inch Tee Mounting 1.5 Inch Union Mounting 1.5 Inch Ball Valve

Material Product Number Material Product Number Material Pressure Product Number
CPVC MH3022 CPVC MH1042 CPVC Low MH1112
316 Stainless Steel MH3011 316 Stainless Steel MH1041 316 SS Low MH1111
CPVC High MH1122
316 SS High MH1121

1 Inch Immersion Mounting


with Junction Box
Sanitary Mount Hand Rail Mounting Assembly (7 foot extension is standard)

Material Product Number Material Product Number Material Product Number


316 SS Closed (2.5”) MH1061 Swivel/Immersion, PVC MH1092 PVC MH3083
316 SS Open (2.0”) MH1051

3. The sensor shall have interchangeable, interactive communications with a host computer
Engineering Specifications pre-calibrated plug-in sensor heads and or display interface using one of several protocols
communications adapters that can be installed including Modbus RTU, DeviceNet, Profibus or
1. The D.O. sensor shall use thee-electrode without powering down the system. USB.
polarographic Clark Cell technology consisting of a
silver reference electrode, a silver anode and a gold 4. The sensor shall have 1 inch NPT threads on 7. The sensor shall have an integral temperature
cathode. both ends to mount into a standard 1 inch pipe sensor to measure temperature independently.
tee, a 1.5 inch union mounting, or a sanitary tee.
2. The sensor shall have hex-shaped wrench flats 8. Replaceable membranes cartridges shall have
to facilitate mounting, and shall be constructed of 5. The built-in electronics of the sensor shall be a pre-installed 50 micron thick gas permeable
a material with exceptional chemical completely encapsulated and o-ring sealed for membrane.
resistance and mechanical strength. This material protection from moisture and humidity.
9. The sensor shall be AquaSensors DataStick
shall enable the sensor to be installed in metal
6. The sensor shall have a built-in pre-amplifier, D.O.
fittings without leakage usually caused by heating
and cooling cycles when dissimilar materials are universal signal conditioning electronics,
threaded together. universal engineering units conversion, and

AquaSensorsTM, LLC Phone: (262) 255-4459 Represented by:


PO Box 607 Fax: (262) 255-4708
Brookfield, WI 53008-0607 E-mail: [email protected]