VP Inverter InfiniSolar 5KW 15KW
VP Inverter InfiniSolar 5KW 15KW
INIFINI PLUS
On-grid Inverter with Energy Storage
MODEL Infini Plus 5KW Infini Plus 10KW Infini Plus 15KW
PHASE 1-phase in / 1-phase out 3-phase in / 3-phase out 3-phase in / 3-phase out
MAXIMUM PV INPUT POWER 10000 W 15000 W 22500 W
RATED OUTPUT POWER 5000 W 10000 W 15000 W
MAXIMUM CHARGING POWER 4800 W 10000 W 15000 W
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage 720 VDC / 900 VDC 720 VDC / 900 VDC 720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage 225 VDC / 250 VDC 320 VDC / 350 VDC 320 VDC / 350 VDC
MPP Voltage Range 250 VDC ~ 850 VDC 400 VDC ~ 800 VDC 400 VDC ~ 800 VDC
Number of MPP Trackers / Maximum Input Current 2 / 2 x 10 A 2 / 2 x 18.6A 2 / A: 37.65A; B: 18.6A
GRID OUTPUT (AC)
Nominal Output Voltage 208/220/230/240 VAC 230 VAC (P-N) / 400 VAC (P-P) 230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range 184 - 265 VAC* 184-265 VAC* Per phase 184-264.5 VAC* Per phase
Nominal Output Current 21 A 14.5A per phase 21.7A per phase
Power Factor > 0.99
EFFICIENCY
> 96%
> 95%
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage/Auto Restart Voltage 120 - 140 VAC / 180 VAC 120 - 140 VAC per phase / 180 VAC per phase 120 - 140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range 170 - 280 VAC 170 - 280 VAC per phase 170 - 280 VAC per phase
Maximum AC Input Current 40 A 40A 40A
PV INPUT (DC)
Maximum DC Voltage 900 VDC 900 VDC 900 VDC
MPP Voltage Range 250 VDC ~ 850 VDC 400 VDC ~ 800 VDC 350 VDC ~ 850 VDC
Number of MPP Trackers/Maximum Input Current 2 / 2 x 10A 2 / 2 x 18.6A 2 / A: 37.65A; B: 18.6A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 202/208/220/230/240 VAC 230 VAC (P-N) / 400 VAC (P-P) 230 VAC (P-N) / 400 VAC (P-P)
Output Waveform Pure Sinewave
93% 91% 91%
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage 720 VDC / 900 VDC 720 VDC / 900 VDC 720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage 225 VDC / 250 VDC 320 VDC / 900 VDC 320 VDC / 900 VDC
MPP Voltage Range 250 VDC ~ 850 VDC 400 VDC ~ 800 VDC 350 VDC ~ 850 VDC
Number of MPP Trackers/Maximum Input Current 2 / 2 x 10A 2 / 2 x 18.6A 2 / A: 37.65A; B: 18.6A
GRID OUTPUT (AC)
Nominal Output Voltage 202/208/220/230/240 VAC 230 VAC (P-N) / 400 VAC (P-P) 230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range 184 - 264.5 VAC* 184-265 VAC* Per phase 184-264.5 VAC* Per phase
Nominal Output Current 21 A 14.5 A per phase 21.7 A per phase
AC INPUT
AC Start-up Voltage / Auto Restart Voltage 120 - 140 VAC / 180 VAC 120 - 140 VAC per phase / 180 VAC per phase 120 - 140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range 170 - 280 VAC 170 - 280 VAC per phase 170 - 280 VAC per phase
Maximum AC Input Current 40 A 40 A 40 A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 202/208/220/230/240 VAC 230 VAC (P-N) / 400 VAC (P-P) 230 VAC (P-N) / 400 VAC (P-P)
93% 91% 91%
BATTERY & CHARGER
Nominal DC Voltage 48 VDC
Maximum Charging Current Default 60A, 5A - 100A (Adjustable) Default 60A, 5A - 200A (Adjustable) Default 60A, 5A - 300A (Adjustable)
GENERAL
PHYSICAL
Dimension, D x W x H (mm) 204.2 x 460 x 600 167.2 x 500 x 622 219 x 650 x 820
Net Weight (kgs) 29 40 62
INTERFACE
Communication Port RS-232/USB
Intelligent Slot Optional SNMP, Modbus, WI-FI and GPRS card
ENVIRONMENT
Humidity 0 ~ 90% RH (Non-Condensing)
Operating Temperature -10 to 55°C
Altitude 0 ~ 1000 m**
*These figures are based on VDE-4105 standard. All figures may vary depending on different AC voltage and country requirements.
** Power derating 1% every 100 m when altitude is over 1000m
Product specifications are subject to change without further notice.