Hydrogenated Castor Oil
Hydrogenated Castor Oil
Printed by: USP NF Official Date: Official as of 01-Jan-2018 Document Type: NF @2024 USPC
Do Not Distribute DOI Ref: 79xem DOI: https://doi.org/10.31003/USPNF_M13820_04_01
1
Table 1
Hydrogenated Castor Oil
Hold Time
Initial Tempera- Final at Final
Tempera- ture Tempera- Tempera-
ture Ramp ture ture Total Time
(°) (°/min) (°) (min) (min)
80 0 80 1 1
80 30 140 0 3
140 20 180 5 10
180 2 250 10 55
al
CAS RN®: 8001-78-3.
DEFINITION Table 2
Hydrogenated Castor Oil is refined, bleached, hydrogenated, Component Relative Retention Time
and deodorized Castor Oil, consisting mainly of NLT 70.0%
of the triglyceride of hydroxystearic acid. ci Methyl palmitate (C16:0) 0.27
12-ketostearate
and USP Methyl 12-Hydroxystearate RS, in Diluent Analysis
Sample solution: Transfer 140 mg of Hydrogenated Castor Samples: Standard solution 1, Standard solution 2, and
Oil to a 10-mL screw-cap test tube, add 3.0 mL of Diluent, Sample solution
and mix well. Add 0.5 mL of 0.5 M sodium methoxide in Calculate the relative response factor, F, for methyl
methanol,1 and mix with the sample. Allow the reaction to 12-hydroxystearate:
proceed at room temperature for 2 h. After 2 h, add 5 mL
of water, and mix. Centrifuge the test tube at 1000 × g for F = (r S/r R) × (C R/C S)
5–15 min at 4° until a clear organic layer forms. Separate
the organic layer, and remove the aqueous layer. Place an rS = peak area of methyl stearate from Standard
aliquot of the organic layer into an autosampler vial. solution 2
Chromatographic system rR = peak area of methyl 12-hydroxystearate from
(See Chromatography á621ñ, System Suitability.) Standard solution 2
Mode: GC CR = concentration of USP Methyl 12-Hydroxystearate
Detector: Flame ionization RS in Standard solution 2 (mg/mL)
Column: 0.32-mm × 30-m fused silica capillary bonded CS = concentration of USP Methyl Stearate RS in
with a 0.25-µm layer of phase G16 Standard solution 2 (mg/mL)
Temperatures
Injection port: 240° Correct the peak area of methyl 12-hydroxystearate in the
Detector: 250° Sample solution by multiplying by F.
Column: See Table 1 for oven program. Calculate the percentage of each fatty acid component in
the portion of sample taken:
https://online.uspnf.com/uspnf/document/1_GUID-A8449C78-AA9A-4DE2-92DD-422ABA915930_4_en-US 1/4
Printed on: Fri Jan 05 2024, 09:17:30 PM(EST) Status: Currently Official on 06-Jan-2024 DocId: GUID-A8449C78-AA9A-4DE2-92DD-422ABA915930_4_en-US
Printed by: USP NF Official Date: Official as of 01-Jan-2018 Document Type: NF @2024 USPC
Do Not Distribute DOI Ref: 79xem DOI: https://doi.org/10.31003/USPNF_M13820_04_01
2
al
Procedure for Class II : 85°–88° Samples: System suitability solution and Sample solution
Calculate the percentage of each of the triglycerides in the
ASSAY
portion of sample taken:
• TRIGLYCERIDE COMPOSITION
Solution A: Methanol Result = (r U/r T) × 100
Solution B: 2-Propanol
Mobile phase: See Table 4.
Table 4
ci rU
rT
= peak area of each individual triglyceride from the
Sample solution
= sum of all the peak areas, excluding the solvent
Time Solution A Solution B peak, from the Sample solution
(min) (%) (%)
ffi
0 100 0 Acceptance criteria: Hydrogenated Castor Oil exhibits the
composition profile shown in Table 6.
20 50 50
23 0 100 Table 6
Percentage
25 100 0
Component (%)
O
35 100 0
Glyceryl tri(12-hydroxystearate)
[or tri(12-hydroxystearoyl)-glycerol] ≥70.0
Diluent: Methylene chloride Di(12-hydroxystearoyl)-(12-oxostearoyl)-glycerol ≤14.0
System suitability solution: 3.0 mg/mL of USP
Hydrogenated Castor Oil RS in Diluent. [NOTE—Due to low Di(12-hydroxystearoyl)-palmitoyl-glycerol ≤2.0
solubility, sonicate the solution for about 2–3 min.] Di(12-hydroxystearoyl)-stearoyl-glycerol 10.0–23.0
Sample solution: 3.0 mg/mL of Hydrogenated Castor Oil in
Diluent. [NOTE—Due to low solubility, sonicate the solution Di(12-hydroxystearoyl)-arachidoyl-glycerol ≤2.0
for about 2–3 min.]
Chromatographic system IMPURITIES
(See Chromatography á621ñ, System Suitability.) • LIMIT OF NICKEL
Mode: LC [CAUTION—When using closed high-pressure digestion
Detector: Evaporative light-scattering vessels and laboratory microwave equipment, the
Column: 4.6-mm × 25-cm; 5-µm packing L1 safety precautions and operating instructions given
Temperatures by the manufacturer must be followed.]
Column: 25° [NOTE—If an alternative apparatus is used, adjustment
Detector: 40° of the instrument parameters may be necessary.]
Flow rate: 1.0 mL/min Nickel standard stock solution: Dilute nickel standard
Injection volume: 5 µL solution TS two-fold with water. This solution contains the
Run time: 35 min equivalent of 5 µg/mL of nickel.
[NOTE—Depending on the different settings of the Standard solutions: Transfer 25, 50, 75, and 100 µL of
Detector, the Temperatures and Flow rate can be Nickel standard stock solution to four identical 25-mL
adjusted as long as system suitability requirements volumetric flasks. To each flask add 0.5 mL of a 10-mg/mL
are met.] solution of magnesium nitrate, 0.5 mL of a 100-mg/mL
System suitability solution of monobasic ammonium phosphate, and 6.0 mL
Sample: System suitability solution of nickel-free nitric acid. Dilute with water to volume, and
[NOTE—See Table 5 for relative retention times.] mix well. [NOTE—Content of nickel in the nickel-free nitric
acid is NMT 0.005 ppm.] The Standard solutions contain
0.005, 0.01, 0.015, and 0.02 µg/mL of nickel, respectively.
https://online.uspnf.com/uspnf/document/1_GUID-A8449C78-AA9A-4DE2-92DD-422ABA915930_4_en-US 2/4
Printed on: Fri Jan 05 2024, 09:17:30 PM(EST) Status: Currently Official on 06-Jan-2024 DocId: GUID-A8449C78-AA9A-4DE2-92DD-422ABA915930_4_en-US
Printed by: USP NF Official Date: Official as of 01-Jan-2018 Document Type: NF @2024 USPC
Do Not Distribute DOI Ref: 79xem DOI: https://doi.org/10.31003/USPNF_M13820_04_01
3
al
and 12.0 mL of nickel-free nitric acid. Dilute with water to Acceptance criteria: NMT 11.0 mL of 0.1 N sodium
volume, and mix well. hydroxide VS, corresponding to NMT 3.1 for acid value
Instrumental conditions • FATS AND FIXED OILS á401ñ, Procedures, Hydroxyl Value
(See Atomic Absorption Spectroscopy á852ñ.) Sample solution: 2 g in a glass-stoppered, 250-mL conical
Mode: Atomic absorption, equipped with a graphite
ci flask. Add 5.0 mL of a freshly prepared mixture of acetic
furnace, a background compensation system, and a anhydride and pyridine (1:3), and swirl to mix. Connect the
coated tube resistant to pyrolysis flask to a reflux condenser, and heat on a steam bath for
Analytical wavelength: 232.0 nm 2 h. Add 10 mL of water through the condenser, swirl to
Lamp: Nickel hollow-cathode mix, heat on a steam bath for an additional 10 min. The
Temperature: Maintain the drying temperature of the titration can be performed on a warm solution of 50°–65°
ffi
furnace at 120° for 35 s after a 5-s ramp; maintain the to avoid a flocculation of the substance. Add through the
ashing temperature at 1100° for 10 s after a 30-s ramp; condenser 15 mL of normal butyl alcohol that has
maintain the cooling temperature at 800° for 5 s after a previously been neutralized to phenolphthalein, remove
5-s decrease; and maintain the atomization temperature the condenser, wash the tip of the condenser and the sides
at 2600° for 7 s. [NOTE—The temperature program may of the flask with an additional 10 mL of neutralized normal
be modified to obtain optimum furnace temperatures.] butyl alcohol, and add 1 mL of phenolphthalein TS.
O
https://online.uspnf.com/uspnf/document/1_GUID-A8449C78-AA9A-4DE2-92DD-422ABA915930_4_en-US 3/4
Printed on: Fri Jan 05 2024, 09:17:30 PM(EST) Status: Currently Official on 06-Jan-2024 DocId: GUID-A8449C78-AA9A-4DE2-92DD-422ABA915930_4_en-US
Printed by: USP NF Official Date: Official as of 01-Jan-2018 Document Type: NF @2024 USPC
Do Not Distribute DOI Ref: 79xem DOI: https://doi.org/10.31003/USPNF_M13820_04_01
4
al
ci
ffi
O
https://online.uspnf.com/uspnf/document/1_GUID-A8449C78-AA9A-4DE2-92DD-422ABA915930_4_en-US 4/4