NBC

Review Items N/A  Observations


Reference
STRUCTURE ƒ complete
ƒ window cleaning anchorage systems
ƒ final review conducted by P. Eng
HVAC ƒ complete and operational
ƒ fire dampers at all fire separations 3.1.8.7.–3.1.8.9.
ƒ venting of commercial cooking equipment 6.2.2.6.
ƒ smoke control verification in high buildings 3.2.6.10.
ƒ final review conducted by P. Eng
PLUMBING ƒ complete, tested and operational
ƒ backflow prevention devices installed and 7.1.2.1.
tested
ƒ final review conducted by P. Eng
ELECTRICAL ƒ supply, lighting and heating complete and
operational
ƒ emergency lighting 3.2.7.3.
ƒ emergency power 3.2.7.4.
ƒ final review conducted by P. Eng
BUILDING ENVELOPE ƒ environmental separation 5.1.4.2.
ƒ thermal resistance 5.3.1.1.
ƒ precipitation protection 5.6.1.1.
ƒ grading for surface water 5.7.1.1.
FIRE ROUTES ƒ open and accessible 3.2.5.5.–3.2.5.6.
ƒ minimum 6m width
ƒ capable of supporting response vehicles
FIRE ALARM AND ƒ fire alarm system tested and verification 3.2.4.
SUPPRESSION report
ƒ firefighting water supply and hydrant 3.2.5.7.
location
ƒ standpipe system, fire hose cabinets and 3.2.5.8.–3.2.5.12.
extinguishers
ƒ sprinkler/extinguishing system tested and 3.2.5.13.
operational
ƒ fire department siamese pumper 3.2.5.16.
connections
ƒ firefighters’ elevator 3.2.6.1., 3.2.6.5.
NBC
Review Items N/A  Observations
Reference
GUARDS ƒ balconies 3.4.6.5.
ƒ stairs and landings and where drop
exceeds 600 mm
ƒ windows and transparent doors 3.3.1.18.
ƒ height, openings and climbability 3.4.6.5.
ƒ load capacity 4.1.10.1.
ƒ retaining walls
FIRE SEPARATIONS AND ƒ firewall integrity 3.1.10.
FIRE RESISTANCE ƒ conformance of specified assemblies
ƒ verification of spray fireproofing
ƒ exits 3.4.4.1.
ƒ floors
ƒ mezzanines and interconnected floor 3.2.8.1., 3.2.8.2.
spaces
ƒ loadbearing columns supporting rated 3.1.7.5.
assemblies
ƒ roofs
ƒ spatial separation for exterior walls 3.2.3.
ƒ public corridors 3.3.1.4.
ƒ between occupancies 3.1.3.1.
ƒ between suites 3.3.1.1
ƒ garbage, mechanical service, janitor rooms 3.6.2.
ƒ shafts 3.6.3.
ƒ labeled door, frame and other closures 3.1.8.
ƒ firestopping 3.1.9.1., 3.1.11.
ƒ combustible piping penetrations 3.1.9.4.
ƒ hazardous substances – Fire Code 3.3.1.2.
compliance
EXITS ƒ separation integrity 3.4.4.4.
ƒ door swing direction 3.3.1.10., 3.4.6.11.
ƒ door hardware, latching and self-closing 3.1.8.11., 3.1.8.13.
devices
ƒ panic hardware, hold open and 3.4.6.15.
electromagnetic release
ƒ handrails, continuous one side 3.4.6.4.
ƒ uniform rise and run 3.4.6.7.
ƒ exit signs 3.4.5.
ƒ lighting 3.2.7.1.
ƒ unobstructed safe egress at grade
NBC
Review Items N/A  Observations
Reference
BARRIER-FREE ACCESS ƒ exterior walk and ramp to parking 3.8.3.2., 3.8.3.4.
ƒ entrance threshold 3.8.3.3.
ƒ door operator 3.8.3.3.
ƒ washroom clearances and fixturing 3.8.3.8.–3.8.3.12.
ƒ handrail extensions 3.4.6.4.
ƒ signage for parking, entrance, washrooms 3.8.3.1.
ƒ corridor obstructions affecting visually 3.3.1.9. (3)
impaired
UNFINISHED BUILDING ƒ compliance within occupied areas
OCCUPANCY
ƒ housekeeping
ƒ authority to occupy permit obtained
AS-BUILT CONFORMITY ƒ consistency with approved documents 2.6.2.1.
ƒ authorization for changes obtained
COMMENTS: