 Ensure to cut off the power supply when installing and uninstalling the extension words Special use SFD0~SFD5999 The communication port COM1 pin diagram is as follows:
XD5E-30T4-E PLC card. High speed processing High speed counter, pulse output, external interruption
 It needs to replace the battery when power is on (ensure the memory data is not lost), ability 1 2
Fast manual [No.: S121042 1.0] when the equipment is running, it must be operated by a professional electrical
2:PRG
Password protection 6-bit ASCII 3 4 5 4:RxD
Thank you for purchasing Xinje XD5E-30T4-E. This manual mainly introduces the 8
technician wearing an insulating glove. Self diagnostic function Power on self-inspection, monitoring timer, syntax checking 6
specifications, electrical characteristics and usage methods of XD5E-30T4-E for your 7 5:TxD
1: User program capacity refers to the maximum capacity in the confidential download 6:VCC
reference at any time. Before using the product, please read this manual carefully, and safer
wiring operation under the premise of fully understanding the content of the manual. For
Production information mode.
Mini Din 8-pin port 8:GND
the design method and instructions of XD5E-30T4-E program, refer to "XD/XL Series  Naming rule 2: refers to the input and output points that can actually be connected to peripherals.
Programming cable:
3,4: Extension module (XD5E can extend up to 16 at the same time) and I/O address
Programmable Controller Instruction User Manual" and "XD/XL Series Programmable
XD 5 E – 30 T 4 - E allocation (octal) of extended BD (up to 1 at the same time).
Controller Positioning User Manual". For the introduction of XD5E-30T4-E hardware,
①②③ ④⑤⑥ ⑦ 5: The memory area is the default power failure holding area (Note: XD5E series PLC
refer to XD/XL Series Programmable Controller Hardware User Manual; for the
① series XD:XD series PLC power failure holding area can not be modified). 5 1
communication function of Ethernet, refer to TCP/IP Communication User Manual based
② type 5: enhanced 6: Special use (non-power-down maintenance) refers to registers for special use occupied 2 1
on Ethernet; for the function of X-NET Bus, refer to X-NET Bus User Manual. 5 43
③ Ethernet E:Ethernet communication by the system, which can not be used for other purposes. For details, refer to the relevant 8 6
XD5E-30T4-E features: ④ I/O 30:16 input/14 output
7
 With Ethernet port, support 4-axis pulse output;
contents of the chapter "List of Special Soft Components" in the appendix of the 9 6
⑤ Output type T:transistor output Instruction Manual.
 Higher instruction processing speed (about 12-15 times of XC series); Mini Din 8-pin male port DB9 female port
⑥ Pulse channel 4:4 channels of pulse output
 XD5E-30T4-E can connect up to 16 XD series I/O and analog right expansion
⑦ Power supply E:AC220V Table 3: Product model list Note: the above diagram is for DVP cable, if it is XVP cable, please connect pin 1 of Mini
modules. Type Input Output Din8 and pin 7 of DB9.
 At most one BD board and one left extended ED module can be expanded.  Basic parameters AC power supply (I) (O)
 Compatible with most common functions of XC series. Table 1:XD5E-30T4-E general specifications  RS485 serial port (COM2, A is RS485+, B is RS485-) can be used to connect HMI,
Relay output Transistor output Mixed output
Safety notes Item Specification
NPN - XD5E-30T4-E - 16 14 communicate with some instruments, etc. It can also be used to connect PC
 Control system design notes Insulation voltage Up DC500V 2MΩ programming software and PLC. Support MODBUS, X-NET Fieldbus
Anti-jamming Noise voltage 1000Vp-p 1us pulse 1 minute communication, free format communication.
Dangerous!
 Ethernet Port (RJ45) supports program download, online monitoring, remote
 Make sure to design safe circuit for application, ensure the control system can work Air No corrosive, flammable gas
Electrical design reference monitoring and communication with other devices in LAN.
safe when the external power outages or PLC has fault. Environment 0℃~60℃
The configuration of the input and output terminal of XD5E-30T4-E is listed here.
 It is important to set emergency brake circuit, protection circuit, interlock circuit for Environment
temperature 5%RH~95%RH(no condensation)
forward reverse rotation, position upper and lower limit interlock switch to prevent Com 1 USB port, fast download/upload program/online monitoring
 Product structure
humidity
from machinery damage.
Com 2 RS232(COM1), connect PC, HMI to programming or debug
 For the safe operation of equipment, please design external protection circuit and (1) (8)
Note: When using, please pay attention to the matching of firmware version
safety mechanism for output signal related to major accident.
Com 3 RS485(COM2), connect meter, VFD, etc. (2) (9) (14)
Com 4 RJ45, support Ethernet communication, make the PLC access to and programming software version of PLC, as shown in the table below.
 All the output will be shut down when PLC found system error. The output maybe out
of control when the controller circuit has error, please design suitable external control LAN or WAN ●

COM
COM
X0
X1
X2
X3
X4
X5
X6
X7
X10
X11
X12
X13
X14
X15
X16
X17
A
B Hardware version (check the Xinje PLC programming software (check the
circuit to ensure the normal working of equipment. (3) PROGRAMMABLE CONTROLLER
0 1 2 3 4 product label) help menu)

Xinje Electronic Co.,Ltd


5 6 7

DATE:20120701
TYPE:XD5E-30T4-E
SN:201207011525
Installation Install on the rail directly with screw M3
 If the PLC output unit is broken, they cannot be controlled to be ON or OFF. COM1
X
PWR
(10) V3.5.2b and down V3.5.2(20180606)
(4)
XD5E-30T4 RUN

Ground The third ground(cannot ground together with high voltage -E ERR

 PLC is designed for indoor electric environment, the power supply system should
Y

0 1 2 3
V3.5.3 and up V3.5.3 and up
(5) 4 5 6 7
(15)
have lightning protection device, ensure that lightning overvoltage is not applied to system)
Table 2:XD5E-30T4-E performance specifications 0V COM0 Y1 Y3 Y4 Y6 COM2 Y11 Y13 Y15


24V ● Y0 Y2 COM1 Y5 Y7 Y10 Y12 Y14

the power input or signal input, output terminal of PLC, avoid equipment damage. Item Specification (6) Extended Communication Port (COM3) can be used to communicate with some
(7) (11) instruments. The XD-NES-ED interface of ED module is as follows:
Program execution mode Cyclic scanning mode (12)
(13)
 Installation and wiring notes Programming mode Instruction, ladder chart
Dangerous! Processing speed 0.05us Part name:
(9): system light
 Do not use the PLC in the following places: dust, lampblack, conductive dust, Memory FlashROM and lithium battery (3V button battery) (1): input terminal, power supply terminal,
※1 PWR: power supply light
corrosive gas, flammable gas. Exposure to the environment of high temperature, dew, User program capacity 1MB com2
RUN: running light  Extended Communications Port (COM4) can be used to communicate with some
wind and rain. Electric shock, fire, vibration, malfunction, misoperation also can I/O Total 30 points (2): input label
ERR: error light instruments. The models and functions are shown in the following table:
cause product damage. numbers Input 16 points X0~X17 (3): COM1
(10): extention module access Name function
 Do not make scrap metal and wire drop into the controller vent when wiring, it may ※2
Output 14 points Y0~Y15 (4): Ethernet port
(11): installation hole (2) XD-NE-BD RS485/fieldbus control/motion control fieldbus
cause fire, fault, wrong operation. Internal coil (X)
※3
1280 points, X0~X77、X10000~X11777、X20000~X20177、 (5): output label
(12): output indicator light communication BD card
 After installing the PLC, make sure there is no foreign object covering the ventilation, X30000~X30077 (6): USB port
(13): rail mounting hook XD-NS-BD RS232 communication BD card
otherwise the heat dissipation will be bad and cause fire, fault and wrong operation. 1280 points, Y0~Y77、Y10000~Y11777、Y20000~Y20177、 (7): output terminal, 24V output terminal
(14) product label XD-NO-ED RS485/fieldbus control optical fiber communication BD card
 The wiring of installation box must be solid and reliable, poor contact may result in Y30000~Y30077 (8): output indicator light
(15) ED module access
wrong action. Internal coil (Y)
※4
87000 M0~M69999【HM0~HM11999】
※5
The interface is shown as below:
※6
Caution! points Special use SM0~SM4999
 Please use external power supply for extension module DC24V power. 9000 S0~S7999【HS0~HS999】
※5

 For serious interference occasions, please use shield cable for high frequency signal
Internal coil(M, HM)
points
 Communication port definition
input and output to improve system anti-jamming capability. 7000 T0~T4999【HT0~HT1999】
※5  XD5E-30T4-E is equipped with four communication ports, one RS232 serial port XD-NE-BD XD-NS-BD XD-NO-BD
Numbers (COM1), one RS485 port (COM2), one Ethernet port and one USB port; one RS232
points
Timer  Power supply specification
 Run and maintenance notes (T)
100ms timer: 0.1~3276.7s or RS485 port (COM3) can be extended through the ED module (XD-NES-ED);
Specification 10ms timer: 0.01~327.67s and one RS232 or RS485 port can be extended through the BD board (XD-NS-BD  The specifications of XD5E-30T4-E (AC power supply with "-E" in the model) are
Dangerous! or XD-NE-BD). shown in the following table:
1ms timer: 0.001~32.767s
 Please connect and dismantle communication cable, extension card and control unit ※5  USB communication port uses general USB download cable to connect PC AC power supply
7000 C0~C4999【HC0~HC1999】
cable after the power supply is shut down, otherwise it may cause equipment damage Numbers programming software and PLC. Before the first time use, it needs to install the
Counter points Item Contents
or incorrect operation. USB driver.
(C) 16-bit counter: K0~32,767 Rated voltage AC100V~240V
 It needs to understand the manual well and fully confirm the safety before operation Specification  RS232 Serial Port (COM1) can be used to connect PC programming software with
32-bit counter: -2147483648~+2147483647 Voltage allowable range AC100V~240V
for on-line modification, forced output, RUN, STOP and so on. PLC, HMI, communication with some instruments, etc. Support MODBUS and free
※5
100000 D0~D69999【HD0~HD24999】 Rated frequency 50/60Hz
Caution! Data register (D) ※6 format communication.
words Special use SD0~SD4999
 Please process the old product as industrial waste.
FlashROM register (FD) 14192 FD0~FD8191
Allowable instant Interruption time ≤0.5 AC period, space  Output specification and wiring Transistor output wiring:
power outage time
≥1 second The output specification is transistor mode. The internal structure and wiring mode of this
mode are described below.
Max below 40A 5ms/AC100V max
Impact current  Output specification
below 60A 5ms/AC200V

Max consumption power 12W External power Below DC5~30V

Power supply for sensor 24VDC±10% 16 points max 200mA, Circuit insulation Light coupling insulation

32 points max 400mA Action indicator LED

1: The power cable should be more than 2 mm2 in order to prevent voltage drop. Max Resistant load 0.3A

2: The programmable controller can continue to work even if there is a power failure load Inductive load 8W/DC24V
within 10 ms. When the power is cut off for a long time or the abnormal voltage drops,
Lamp load 1.5W/DC24V
the programmable controller stops working and the output is also in the OFF state.
When the power supply is restored, the programmable controller starts to run Mini load DC5V 2mA

automatically. Response OFF→ON Below 0.2ms


3: The ground terminals of the basic unit and the expansion module are  Output circuit protection
time ON→OFF Below 0.2ms
interconnected and reliable grounding.
For the inductive load of AC circuit, please use RC instantaneous voltage absorption circuit.
 The main body of PLC provides DC24V power output (24V, 0V terminals), which For the inductive load of DC circuit, please use freewheeling diode
Transistor output:
can be used as power supply for sensors, and the DC24V of 30-point PLC is 400  DC load
mA/DC24V. Please note that this terminal cannot be powered by an external power
supply!
 ● are empty terminals. Please do not connect them externally or use them as
relay terminals.
 The COM terminals of the basic unit and the extension unit should be connected to
each other.

 Input specification and wiring


The input specification is NPN mode. The internal structure and connection mode of this
mode are described below.

 NPN mode specification Note: freewheeling diode IN4007.

Item Contents
Product dimensions and installation
Input signal voltage DC24V±10%
 Installation
Input signal current 7mA/DC24V
The rail can be used to install the basic unit and extension module.
Input ON current Above 4.5mA High speed pulse output
Please use the rail DIN46277.
Input OFF current Below 1.5mA Model T4
Input response time About 10ms High speed pulse output terminal Y0~Y3
Input signal mode Contactor input or NPN open collector transistor External power supply Below DC5~30V ● COM X1 X3 X5 X7 X11 X13 X15 X17 B
COM X0 X2 X4 X6 X10 X12 X14 X16 A

Circuit insulation Photocoupling insulation Action indicator LED light PROGRAMMABLE CONTROLLER
0 1 2 3 4
5 6 7

Input action display LED lights when the input is ON Max current 50mA COM1
X

XDM-32T4
PWR

RUN
-E ERR
Y

Pulse max output frequency 100KHz 0 1 2 3


4 5 6 7

Note: When using the high-speed pulse output function, if the pulse frequency is between

0V COM0 Y1 Y3 Y4 Y6 COM2 Y11 Y13 Y15

NPN wiring example 24V ● Y0 Y2 COM1 Y5 Y7 Y10 Y12 Y14

100KHz and 200KHz, the normal operation of the servo will not be guaranteed. Please
connect about 500 ohms of resistance between the output and 24V power supply. DIN rail hook screw M3
Red(brown) blue

 Transistor output processing


The main unit and extention module can be installed on the DIN46277 rail (width is
 The transistor output of the basic unit has 1 to 4 common terminals.
35mm). for removing the product, it needs to pull the hook then move right the product.
COM X0 X1 X2 X3 X4 X5 COM X0 X1 X2 X3 X4 X5  For load driving power supply, use DC5-30V.
 The internal circuit of the programmable controller and the output transistor are  Dimension (unit: mm)
Switch button wiring 2-wire(NO or NC) proximity switch wiring insulated by a photoelectric coupler, and the common terminals are also separated
from each other.
108.6
 When driving the light coupling, the LED light is on and the output transistor is ON.
100.6 89.9
 The programmable controller takes less than 0.2ms from drive (or cut off) the
Blue(blue) Red(brown)
photocoupler to the transistor ON (or OFF).
DC0V Yellow(black)DC24V  The current of each output point is 0.3A, but due to the limitation of temperature ●
COM
COM
X0
X1
X2
X3
X4
X5
X6
X7
X10
X11
X12
X13
X14
X15
X16
X17
A
B

rise, the total current of 4 output points is 0.5A. PROGRAMMABLE CONTROLLER


0 1 2 3 4
5 6 7
108.0
100.0

 The open circuit current is less than 0.1mA. X


PWR

RUN

ERR

COM X0 X1 X2 X3 X4 X5 Y

0 1 2 3
4 5 6 7

3-wire (NPN) proximity switch wiring 0V COM0 Y1 Y3 Y4 Y6 COM2 Y11 Y13 Y15
24V ● Y0 Y2 COM1 Y5 Y7 Y10 Y12 Y14

Ø4.3