2.

FEATURE PROGRAMMING AT INSTALLER LEVEL

2.1  Programming Sheet


(Fits AV-865, AV-868, AV-2005, AV-2008)
AV-865, AV-2005 refers to zone 1 to 5 only.
Factory Default Program is as shown in table; Blank Square means no default program

 TELEPHONES SIGNAL TEST & AUTO ARMING TIME


Tel. 1 Tel. 2 Tel. 3 Tel. 4 Test Time Auto Arm
Time
010 011 012 013 014 016
(00:01) 00:00
Tel. 1 is also the ‘Follow Me’. Maximum 16 digits + 4 Test signal to central station (014). Codes are defined at
pauses. Tel. 2 and 3 are communicator option. Addresses: 072, 073, 237 & 255. Enter time in 24 hour
format
To insert * in the phone number, program system to dial in DTMF, Hold-down keys # and * (as panic); ‘A’ will
be displayed. For Pause during dialing, hold-down key ‘0’. To erase tel no: hold on 9 untill beep is heard.

 ZONE FEATURES

Feature Address 1 2 3 4 5 6 7 8
Fire zones 019
Zone In Use 020 1 2 3 4 5 6 7 8
Entry/Exit Delay 1 021 1
Entry/Exit Delay 2 022
Entry / Exit Follower 023 2
24-Hours Zone 024
Day Zone 025
Green Reset Zone 026 1 2 3 4 5 6 7 8
Swinger Shutdown 027
Chime 028 1 2
NON-EOL Resistor 029 1 2 3 4 5 6 7 8
Enable Zone Tamper 030
Delayed Power-Up 031
Fast Response 032
Group Bypass 033
Auto Bypass 1 034
Manual Bypass 035 1 2 3 4 5 6 7 8
Siren Out 036 1 2 3 4 5 6 7 8
Alarm 1 Out 037 1 2 3 4 5 6 7
Reserved 038
SLO output 2 039
Dial on Alarm 040 1 2 3 4 5 6 7 8
Sounder on Alarm 041 1 2 3 4 5 6 7 8
Normally Open (N.O.) 042
1 Auto Bypass is applicable on Instant Zones only. 2 SLO is a non-timed output. SLO = Selective output.

Panic Alarm 050 Tamper Alarm 051


Siren on Panic 1 Tamper zone 24H zone 1
Alarm 1 On Panic 2 Out 1 on Tamper 2
Reserved 3 Reserved 3
SLO On Panic (4) SLO on Tamper 4
Telephone Report (5) Reserved 5

 TIME-OUTS

Zone Entry Entry Exit Siren ON OFF A1 Reserv Chime Abort


Respon Delay Delay Delay Time Siren Siren Out ed Time Delay
se 1 2 ** Time Time Time
time **
m. Sec's Sec's x Sec's x Minute Sec's Sec's Sec's - Beeps Sec's
Sec 4 4 s
059 060 061 062 063 064 065 066 067 068 069
0 5 1 2 0 0 0 8 0 4 1 5 0 4 3 0 0 0 0 3 0 4
Note: Address 059 adjusts the response time of zones selected as ‘Fast Response,’ applicable with inertia sensors.
** Maximum value = 64.
 SYSTEM FEATURES

Feature 070 Feature 071


Enable-Siren/Bell Test upon Arming 1 Enable-Erase Follow Me number on Disarm (1)
Enable-Keypad 3 Beeps upon Disarming (2) Enable-Instant Arming via Key 5 2
Enable-Sounder upon Entry Delay (3) Enable-Sounder during exit delay (3)
Enable-Keypad Tactile Beep (4) Enable-Display Troubled/Open Zone (4)
Disable-4 LEDs display during Armed 5 Enable-Manual Bypass via Code No. 1 (5)
Enable-Battery Test upon Arming (6) Lock in Armed after Tamper Alarm * 6
Enable-Code No. 7 for Access Control 7 Enable-Momentary Key-Switch (7)
Enable-Keypad Panic (8) Enable-Code ‘8’ as one time code 8

Feature 072 Feature 073


Enable-Bell mode (1) Enable-Display troubled zones at Disarmed (1)
Enable-Detailed alarm history (2) Enable-Test to central station every hour 2
Enable-Report Opening/Closing (3) Enable-Self contained Bell (0V at alarm) ** 3
Enable-Test signal to central station (4) Reset for smoke via SLO output 4
Enable-Report bypassed zones at Arming (5) Enable- Group Bypass when Arm with Key 5
Enable-Exit delay when delayed zones clear (6) Enable - 2 Siren Beeps at Key Disarming 6
Enable-’ON’ output as SVM trigger 7 Enable - A1 output time follows Siren time (7)
Enable-codes reset to default by * & # (8) Enable - Outputs (A1, ON, SLO) float at active 8

Feature 074 CONTACT ID SETTINGS


Enable-’SLO’ output as SVM trigger 1
201 – 07
Enable – Auto-arming 8 timers *PRO only* 2 202 – 07
Enable – Zone auto reset before alarm time-out 3 203 – 03
Reserved 4 204 – 02
Reserved 5 205 – 02
Reserved 6 206 – 02
Enable-Sleep Mode during AC fail (7) 360 – SUBSCRIBER ID
Enable-Echo Cancellation Tone (AUSTEL) 8 364 – SUBSCRIBER ID
011 – MONITORING STATION TEL #1
012 – MONITORING STATION TEL #1
072 – SELECT 1 – 2 – 3
* (071/6) Not available with PRO ** (073/3) self-contained Bell is operative if Bell
mode selected
Note: Features 070/4 and 071/5 are not operative with PRO panels. Installation in Australia must program ‘8’ in
address 074.

 DIAL PARAMETERS

Pre- Wait Anti- Dial Dial Tel. Inter- Re- Pulse Pulse Inter # of Insta Ring
Dial for Jam tone Mode MSG Call Dial MAKE BREA Digit Rings nt Lengt
Delay Dial Delay detect Time Delay Cycle K Delay for mode h
Tone ion s mode m
(max. m answe
) r

Sec's Sec's Sec's 00=No 0=Pulse Sec's Sec's XX 5 mS 5 mS 50 mS Tel. 00=No 20mS
01=Yes s Cycle Rings 01=Yes
1=DTMF
080 081 082 083 084 085 086 087 088 089 090 091 092 093
0 2 0 4 1 0 0 0 0 1 5 0 2 2 0 0 0 3 0 8 1 2 2 0 1 0 2 0

Note address 091: The download is ENABLED by default. Enter a value of 21 at address 091 to disable modem (21
rings for modem not accepted by telephone net). To ENABLE enter 01 to 20 at address 091. To enable Instant Modem
Answer (Answer Now) enter 01 in address 092. In use mode; hold-down key 6 then hold-down key 1. ‘A’ is displayed
in confirmation.

SET USER CODES: Address 099 provides setting of user codes 1 to 8.

SET FACTORY DEFAULT:

AV-868, AV-2008: In address 200 enter 8 0, program will revert to factory default programming
AV-865, AV-2005: In address 200 enter 5 5, program will revert to factory default programming
Display version: The version (revision) and its date can be displayed in installer programming mode by command 200+00