GREEN’UP PREMIUM

CHARGING STATIONS
COMMUNICATION KIT & RFID READER
MANUAL
USER’S

THE GLOBAL SPECIALIST IN ELECTRICAL AND


DIGITAL BUILDING INFRASTRUCTURES
This document is a user manual describing the characteristics of
the Legrand communication kit Cat.no 0 590 56.

It aims at completing the installation instructions supplied


with the product.

The information given in this manual are helping:

- to the navigation through the web pages of the communication


kit
- to the complete configuration of your communication kit (using
mode, with/without tag reader)
- with management of the available commands (on, off,
programming, ...) in your communication kit.
LEGAL INFORMATION
- to download stored data from your charging station
Presentation pictures do not always
include Personal Protective Equipment
(PPE), but this is a legal and regulatory
- to the software maintenance of your Green’Up station and its
obligation that must be scrupulously res-
pected. communication kit.
In accordance with its continuous impro-
vement policy, Legrand reserves the right
to change the specifications and illus-
trations without notice. All illustrations,
descriptions and technical information
For more information, please contact your Legrand Customer
included in this document are provided
as indications and cannot be held against
Legrand.
Service.
TABLE OF CONTENTS
URL OF THE CHARGING STATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

DATE AND TIME OF THE CHARGING STATION. . . . . . . . . . . . . . . . . . . 3

DASHBOARD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

NETWORKS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

CHARGING MODE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

PROGRAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

ACTIONS/SETTINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

RFID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

STORED DATA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

MODEM CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 1
WWW.LEGRAND.COM
URL of the charging station
URL of the station: IP address to reach Login form, request for valid TECHNICAL INFORMATION:
the web pages. login and password. - Compatible web pages
(by default: IP: 192.168.1.200 By default: Internet Explorer, Mozilla, Chrome;
Mask: 255.255.255.0 Login: admin - Automatic disconnection
Gateway: 192.168.1.1) Password: admin after 15min of inactivity;
If the login and/or the password - The back button, the closing of the tab
are not valid, the fields are blank or the closing of the browser lead to a
after the page is refreshed. cancellation of authorization: the user
will be in the obligation to reconnect;

- A change of login requires a change of password.


- If you forget your password, a reset of the charging stations allows you to go back to the
default login and password. Contact your Legrand Customer Service.

TS
TEN
C ON
E OF
BL
TA

2
Date and time of the charging station
Date and time of the charging Allows you to change the Allows you to change Login reminder.
station: Synchronization login and password. It is the language. Changing Link to disconnect from
of the date and time at recommended to change your the language will lead the web pages and return
each connection. login and password when to a disconnection and a to the login page.
you first connect (default: return to the login page.
Login: admin
Password: admin)

TS
TEN
C ON
E OF
BL
TA

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 3
WWW.LEGRAND.COM
Dashboard (1/4)
Navigation banner of the web pages, each tab corresponds to a link to a new web page.

Dashboard: Quick and detailed view of the charging station status


Networks: Modify the wired and wireless network parameters of the communication kit
Charging mode: Change the operating mode of the charging point(s)*
Program: Manage a program list of the charging point(s)*
Actions/Settings: Carry out commands to control the charging point(s). Also allows to manage the maximum charge
current of the charging point(s)*
RFID: Manage the operation of the RFID reader (if installed)
Stored data: Retrieve consumption histories per charging session and error histories of the charging point(s)*
Information: Retrieve the technical information of the charging point(s)*
Update your charging station
Set up automatic e-mails

* A double charging station corresponds to 2 charging points

TS
TEN
C ON
E OF
BL
TA

4
Dashboard (2/4)
Name of the station,
allows quick identification
of the station.
Information on the Quick information about
connection type of the the activation status
Typology of communication kit. of the RFID option.
the product,
Allows you to enter/ Icon for RJ45 connection Icon for inactive RFID
maximum power
modify the «name»
of the station
field of the station.
and catalogue Icon for active RFID
A second click will save it. Icon for WiFi connection
number.

TS
TEN
C ON
E OF
BL
TA

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 5
WWW.LEGRAND.COM
Dashboard (3/4)
A single charging station is considered Information updated every second. Information on the status of the charging points.
to be a single charging point.
A double charging station is -EV not connected to the station => «Ready to charge»
considered two independent charging -EV connected waiting for charge => «T2S waiting to start» or « 2P+T waiting to start »
points, with the left side physically -EV connected and charging => «T2S on charge» or «2P+T on charge »
representing the left charging point -EV at the end of charging (mode 3) => «T2S Charge completed »
when viewed from the front. -Charging station is locked => «Locked »
The right side physically represents -Charging station being updated => «Updating in progress»
the right charging point when -Faulty charging station => «Error»
viewed from the front.
Information about the charging mode used: Immediate charging, External signals,
Program, Modbus.
If RFID activated, recall of the ID of the tag in use.

TS
TEN
C ON
E OF
BL
TA

6
Dashboard (4/4)
Information updated every second. Information updated every second.
Information on current error on the charging station. Information on the electrical data of the charge point(s).

Possible error: Information:


-Locking error T2S socket -Max charge current => Adjustment current of the station that
-Unlocking error T2S socket can be changed in the Actions/Settings tab;
-Short Error -Max cable current => Indicates the charge current of the cable
-CP circuit on station/cable/vehicle used;
-Error CP short-circuit on the station -Setpoint current => Setpoint current sent by the station to the
-Error opening switch domestic socket vehicle;
-Error Closing switch on domestic socket -Instantaneous charging current => Instantaneous charging
-Error Opening switch on T2S socket current recorded by the measuring split cores.
-Error Closing switch contact T2S socket
-Diode error not detected on the vehicle side
-Error T2S socket overcharge.
-Error Overcharge of the domestic plug
-Unknown error

TS
TEN
C ON
E OF
BL
TA

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 7
WWW.LEGRAND.COM
Networks (1/3)
Network parameters including: IP address Button to activate or not the DHCP.In the Button to navigate between wired,
of the communication package ; example the DHCP is activated (default wireless and Modbus network settings.
Subnet mask ; position in wireless).DHCP deactivated =>
IP address of the network gateway; allows to modify the network parameters.
In this example, no wireless network is DHCP activated => allows the server
connected. If the DHCP option is activated, to assign the network parameters.The
the fields can no longer be modified. modification is instantaneous.
Each modification requires validation via DHCP is to be avoided when you
the Save button. The saving causes an want to reach web pages by IP
immediate restart of the communication address with your browser.
kit.

TS
TEN
C ON
E OF
BL
TA

8
Networks (2/3)
Wireless network settings:

SSID: list of available networks seen by the station (if the station is connected to a wireless network, its SSID will be displayed first);
WiFi key: corresponds to the access key of the WiFi network (often called WEP key);
Security: type of network security.

TS
TEN
C ON
E OF
BL
TA

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 9
WWW.LEGRAND.COM
Networks (3/3)
Modbus network parameters Association of a MID meter
These parameters are only necessary when the stations are It is possible to connect a Legrand MID meter to the RS 485
connected on the same RS485 network in an installation with input of the communication kit. This will allow to send back
a Legrand webserver in the case of energy management of a the consumptions (MID certified) through the OCPP protocol.
charging stations site. The Modbus address of the meter must be ‘5’ (default value on
Legrand meters).
Modbus parameters of each charge point This possibility is not compatible with the webserver.
Each charge point will have its own modbus address.
The other parameters (parity, speed, stop bit) will depend on the
configuration of your RS485 network.

TS
TEN
C ON
E OF
BL
TA

10
Charging mode
Button to navigate Button for selecting the charging mode of the charge
between the right point.
and left side of the -Immediate charge (default mode): allows the EV to be
station. If the station charged without waiting for authorization
has only one side, -External signals: allows you to take into account the Information area for the
the right side is dry contact inputs for charging (with or without possible operation of the charging
always displayed. override on the station) mode and for setting the
-Programming: allows you to take into account the parameters according
charge schedules created in the Program tab of the to the selected charging
navigation bar. mode.
-Modbus: allows you to set up the Modbus RS485
network and operate your charge point via Modbus Fast information zone,
with possible integration with the Legrand Energy Web refreshes every second.
Server.
-OCPP (Open Charge Point Protocol): allows you to set
up the station and server connection data and activate
the OCPP connection.

TS
TEN
C ON
E OF
BL
TA

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 11
WWW.LEGRAND.COM
Program (1/3)
Button to navigate Button to add Visualization area of the created programs. The Fast information zone,
between the right and a program. information: start time - end time, day of taking refreshes every second.
left side of the station. into account. It is possible to quickly deactivate
If the terminal has only the program via the button on the right. In
one side, the right side this example, programs 1 and 3 are active and
is always displayed. program 2 is inactive. The station will therefore
not allow charging during program 2.

It is not possible to create several


programs in the same period.

TS
TEN
C ON
E OF
BL
TA

12
Program (2/3)
Start time of the Cursor for modifying the setpoint End time of the program,
program, in this example current during the planning period, in this example the
the start time is set to here 32A. end time is set to 19:00
4:00 am. The time step is in the evening. The
15 minutes. time step is 15 min.
To create a 2
day program.
Application day of It is necessary
Button to cancel the new to create 2
the program, in this Warning message indicating a time
program or to validate programs :
example the application slot already occupied or an error on
the new program. the 1st with an end at
days are Monday, the program end time. 24H00 and the second
Wednesday and Friday.
with a start at 0H00.

Possible warning message

TS
TEN
C ON
E OF
BL
TA

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 13
WWW.LEGRAND.COM
Programm (3/3)
Start time of the Cursor for modifying the set current during the planning period,
program, in this here 16A. The maximum power depends on the internal setting of
example the start the station during installation (internal switches).
time is set to 0:00
am. The time step is
End time of the program, in
15 min. Button to cancel or validate this example the end time
the new program. is set to 06:00 am. The time
Application day of the step is 15 min.
program, in this example
the application days are Button to delete the
Monday, Wednesday and program.
Friday.

TS
TEN
C ON
E OF
BL
TA

14
Actions/Settings (1/2)
Button to navigate Actions available on the charge point:
between the right
and left side of the - Disable/enable T2S socket => allows to disable the T2S socket, the socket becomes unusable ;
station. If the station - Disable/enable the 2P+T socket => allows to disable the 2P+T socket, the socket becomes unusable;
has only one side, - Lock/unlock the side => allows you to make the side not functional, the station is then unusable and can only
the right side is be activated via this «Lock/unlock» function;
always displayed. - Start/Stop => allows you to start a charge or stop the charge remotely
- Current setting => allows the setting of the maximum charging current (except in case of programming
where the setting is done during the creation of the program).

Fast information zone, refreshes every second.

TS
TEN
C ON
E OF
BL
TA

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 15
WWW.LEGRAND.COM
Actions/Settings (2/2)
Current limitation allocated to both sides. Option only available for double stations.
This option allows you to allocate a maximum power to a double
station. The charge will not exceed the programmed current
when two vehicles are charging simultaneously and the current
supplied to each side will depend on the need of the vehicles.

Allows you to activate or not the limitation option and to set the
maximum intensity that will be allocated to the two charging
points.

TS
TEN
C ON
E OF
BL
TA

16
RFID (1/3)
Button to activate or deactivate the RFID function. Fast information zone, refreshes every second.
Warning, the RFID kit Cat.no 0 590 59 must be
installed before activating this function.
(otherwise the station is no longer functional).

TS
TEN
C ON
E OF
BL
TA

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 17
WWW.LEGRAND.COM
RFID (2/3)
Tags programming via the reader:

-Using mode, in this case, the station is ready to be used, in local mode, normally. If the user’s tag is recognized by the station, then
charging is authorized. The user can plug in before or after the tag is presented. An animation of the lights allows to easily identify if
the user is recognized or not by the station.

-Storing mode, in this case, the station switches the reader to storing mode. Each tag passed in front of the reader will be stored in
the list of authorized tags. An animation of the lights allows to know if the tag has been registered in the list. Once the list has been
created, put your station back in using mode.

TS
TEN
C ON
E OF
BL
TA

18
RFID (3/3)
Create a tags list:

-The “ Download RFIDList.csv “ button allows you to download the list of authorized tags in the communication kit. The file is broken
down into three columns, the first column indicates the date and time the tag was saved, the second column indicates the tag ID and
the third column indicates the name associated with the tag.
-The “Select a list” button allows you to select a tag list file in csv format on your computer.
-The “Store RFIDList.csv” button is used to load the list of tags into the communication kit. At this moment, this list replaces the
previous one.
It is then very easy to create a list of tags and to duplicate it to other stations. In order to create a list of tags manually, it is convenient
to download the RFIDList.csv file and to insert lines. The internal format of the RFIDList.csv file must be respected or it will not work
properly. (otherwise the list of tags will not be loaded).

TS
TEN
C ON
E OF
BL
TA

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 19
WWW.LEGRAND.COM
Stored data (1/2)
Button to The «Charging stored datas...» button allows you to download the file (.CSV) containing all the charging stored
navigate between data of the charging point. The file is broken down as follows:
the right and
left side of the Session start date Total Time Charging Energy in End of session date Plug type ID (if RFID is Name (if RFID
and time time in without time in Wh and time active) is active)
station. If the min charging min
station has only in min
one side, the 15/02/2018 17:53 962 897 65 3029 16/02/2018 09:54 EVplug
right side is
always displayed. 19/02/2018 16:30 116 24 92 6950 19/02/2018 18:26 EVplug

19/02/2018 18:26 878 877 1 0 20/02/2018 09:03 EVplug

20/02/2018 10:44 1385 1298 87 127 21/02/2018 09:48 EVplug

21/02/2018 11:57 69 1 68 4652 21/02/2018 13:05 EVplug

One can consult the date and time of the beginning of the session, the total time in minutes, the waiting time in
minutes, the charging time in minutes, the energy in Wh, the date and time of the end of the session, the type of
plug used and the ID of the tag used if RFID is activate.
Fast information zone,
refreshes every second.

TS
TEN
C ON
E OF
BL
TA

20
Stored data (2/2)
The «Events stored datas...» button allows you to download the (.CSV) file containing all the errors stored by the charge point. The
file is broken down as follows:

Date Time Error code Error

12/02/2018 12:41:18 0 No error detected

12/02/2018 17:29:05 0 No error detected

15/02/2018 17:46:08 0 No error detected

21/02/2018 10:49:09 0 No error detected

One can consult the date and time of the start of the information, the error code to identify it and a description of the error are stored.
At each restart the station performs a check up of the main functions, the «no error detected» report is stored in the file to guarantee
that everything went well during this phase.

TS
TEN
C ON
E OF
BL
TA

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 21
WWW.LEGRAND.COM
Information (1/2)
«Refresh» button General information Charge point Automatic update activation button : This option
to reset the with the product information (right and enables automatic updating. The station will connect to
communication kit, reference and type, left side separate) an external server and automatically update with the
pressing it causes traceability (date of with software and latest version of the communication kit.
a disconnection manufacture) and hardware version. Please note that some firewalls may block the
and a restart of the serial number connection.
the whole pack. of the station. By deactivating this function, the update can be done
manually by downloading the latest version available
on the Legrand e-catalogue in the software section of
the communication kit (0 590 56).

Information on the communication kit with the catalogue number,


the software version of the communication part and web pages
and the hardware version. Information on the RFID pack with the
catalogue number, the software version and the hardware version.

TS
TEN
C ON
E OF
BL
TA

22
Information (2/2)
Sending automatic e-mails
This option allows you to automatically send an e-mail in order to have the information of the beginning and end of the charge,
of the consumption of each charge, of the errors in progress.

SMTP server: Address of the SMTP service used, example for the google service <i> smtp.google.com </i>.
Username: Username filled in when registering the SMTP service.
Password: Password filled in when registering the SMTP service.
Port: Port used for communication, SSL: 465 OR TLS: 587.
From: link from the sender’s e-mail address to the SMTP service.
To: destination e-mail address.

Activation and periodicity choice of sending historical files : Choice of activating charge or error notifications.

It is possible to receive periodic load and error history


files by email. To do this, it will be necessary to enter the
data relating to the emails notification and to choose the C ON
TEN
TS

OF

frequency (Day, week or month) of the files wishing to be


E
BL
TA

pushed automatically. GREEN’UP PREMIUM


COMMUNICATION KIT & RFID READER USER’S MANUAL 23
WWW.LEGRAND.COM
Modem connection
Green’up Premium charging stations can be connected to a modem when the IP network is not available. Here are two examples of
installations and configurations of modems that can be found on the market:
- Teltonika RUT240 modem - Sierra LX40 modem

Connection:
These modems must be supplied with direct current from 9 VDC to 36 VDC (30 VDC for the Teltonika RUT240 modem). It is therefore
possible to supply them directly from the 12 VDC power supply of the Legrand stations but also from an external power supply.

In order to connect them from the power supply to the Legrand stations, make sure to have the same connection as shown below:
Already used

The white cable and the red cable must be inserted in the same terminal. The green cable is optional, so it is not
necessary to connect it (please refer to the modem installation instructions).

A modem can be used for one or more charging stations (up to 10 charging points).
It is necessary to check this point with your charging operator beforehand.
The modem can be installed inside the charging station or outside, depending on the network coverage and the
quality of the signal. An additional remote antenna can be added.
You must first configure the IP addresses of the station and the modem. To do this, connect your computer to the station
and change the IP address (see page 10), then connect your computer to the modem and repeat the same procedure.
The IP address of the communication kits is by default 192.168.1.200 and the subnet mask is 255.255.255.0.
TS

E OF
C ON
TEN
Once the IP addresses have been changed, connect the modem directly to the communication kit via the RJ45 port. The charging
BL
TA
station is then connected to the network via the modem.

24
Teltonika RUT240 modem configuration:

The settings described in this section are specific to the Teltonika RUT240 modem.
- First install the SIM card in the modem following the procedure described below.
- Then connect the 3 antennas to the modem and connect to the RJ45 connection as described on the previous page.

1- Press the button on the SIM card holder with the needle
2- Remove the SIM card holder
3- Place the SIM card in the holder
4- Insert the SIM card holder into the Modem

- Enter the modem’s default IP address (192.168.1.1) into a search engine.


- Log in using the default user name « admin » and password « admin01 ».

- Once logged in, change the default password for security reasons.

TS
TEN
C ON
E OF
BL
TA

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 25
WWW.LEGRAND.COM
- Click on the « LAN » tab to begin configuring the modem:
• If you have not changed the default IP address of the modem: enter an IP address from 192.168.1.1 to 192.168.1.254
• If you have changed the default IP address of the modem: enter an IP address in the range of the new modem address

- Click on the « Mobile Configuration » tab to set up the wireless network. To do this, enter the PIN code of your SIM card in the
corresponding field.

TS
TEN
C ON
E OF
BL
TA

26
- Click on the « WiFi configuration » tab and change the password in the « key » field.

Then connect to the WiFi network generated by the modem with the password you set earlier and which you can identify with the SSID
« RUT240_FFFF » if you did not change the default SSID.
Once connected to the modem’s WiFi network, you can go to a browser and connect to the charging station’s web pages by entering
its IP address.

TS
TEN
C ON
E OF
BL
TA

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 27
WWW.LEGRAND.COM
Sierra LX40 modem configuration:

The settings described in this section are specific to the Sierra LX40 modem.
- First, install the SIM card in the modem following the procedure described below.
- Then connect the antenna to the modem and connect it to the RJ45 connection as described in the modem installation
instructions.
- Enter the modem’s default IP address (192.169.13.31) into a search engine.
- Connect using the default user name (already entered) and the password written on the label on the modem.
- Click on the « WAN/Cellular » tab and enter the APN and the SIM card PIN.

TS
TEN
C ON
E OF
BL
TA

28
Static IP:
- Click on the «LAN» tab and configure the IP address from 192.168.1.1 to 192.168.1.254.
- Then set the subnet mask to 255.255.255.0 and the gateway to 192.168.1.1.
- Then click on the «Security» tab and set up as many static IPs as there are stations as described in the modem manual.

TS
TEN
C ON
E OF
BL
TA

GREEN’UP PREMIUM
COMMUNICATION KIT & RFID READER USER’S MANUAL 29
WWW.LEGRAND.COM
FOLLOW US
ALSO ON
legrand.com

youtube.com/user/legrand

facebook.com/Legrand

twitter.com/Legrand

pinterest.com/legrandgroup

instagram.com/legrandnews
LE10990AA-05 - February 2022

Head office
and International Department
87045 Limoges Cedex - France
Tel: + 33 (0) 5 55 06 87 87
Fax: + 33 (0) 5 55 06 74 55

You might also like