Compact data logger

Series
Main body
Shown in
GL100-N actual size

GL series adds support for additional


sensors in network with PC and stand-alone
environments with the ability to exchange
input modules.

Sensors Input Terminal / Adapter

Temp./Humidity Acceleration/Temp. Carbon dioxide (CO2) Illuminance/UV Voltage/Temp. Thermistor AC current sensor
GS-TH GS-3AT GS-CO2 GS-LXUV GS-4VT GS-4TSR GS-DPA-AC
Temp. (-20 to 85 ºC), Tri-axial acceleration CO2 concentration Illuminance (max. 200 klx), Voltage (max. 50V) or Temperature Current (50, 100, 200A
4ch 4ch Max.
Humidity (0 to 100 % RH) (max. 10 G), (max. 9999 ppm) UV intensity (max. 30 Temp. (TC: K & T), (up to -40 to 120 ºC), RMS), Power in Single-
2sen-
Temp. (-10 to 50 ºC) mW/cm2) 4ch Logic or Pulse 4ch Logic or Pulse sors or three-phase power
system

Dual port adapter connects up to two modules for simultaneous interface Thermistor sensor AC current sensor
GS-103AT-4P* Example
(Normal type)
1. Temp./Humidity & 2. Temp./Humidity & 3. Illuminance/UV &

Illuminance/UV Carbon dioxide (CO2) Carbon dioxide (CO2)


GS-103JT-4P*
(Ultrathin type)
* Temp. range varies by the type
of sensor.

Connect Easily to your PC

USB cable • USB connection is also available through the GL100 with
real-time control from PC software. Historical data can also
be viewed by directly accessing the internal memory of the
GL100 from the PC software.
micro SD
memory card • Data stored on the GL100 can be easily transferred to the PC
using a microSD memory card and replay in the PC software.

www.graphteccorp.com
Includes Application Software for General-Purpose or Industry-specific Customized Platform
General purpose application software continues to have the ability to view in Y-T chart, waveform, and digital values.
New industry-specific customized software features targeted software in accommodating users with indicators that are
specific and familiar to that industry.
General-purpose software for PC
Digital value
Menu for connection Y-T Chart Display Capture Settings
Full conditions;
Meas. Range,
Capturing,
Alarm, etc.
Statistics
TAB-based display options

Industry-specific software(for PC) Support your specific software


Specific- Measurementv capability
industry Description
• Temperature Accumulation Confirm temperature accumulation, humidity deficit, solar radiation, ultraviolet rays as part of the vital indicators for
Agriculture • Humidity Deficit healthy plant growth. Measure optimal saturation deficit by understanding the best conditions applied for growth,
• Amount of solar radiation flowering, and fruit growth using temperature accumulation and optimal growth environment scheme. Customize your software using the
• Amount of ultraviolet rays
• Search and display Transportation of industrial equipment, temperature controlled transport of food, and warehouse temperature SDK (Software Development Kit)
Logistics acceleration thresholds management can all be monitored to provide the safest and most secure operation. Safety measurements through provided by Graphtec.
• Temperature Accumulation monitoring the vibration of the transport vehicles can be vital to heavy-industrial and vibration sensitive equipment.
• Humidity Deficit Accumulated temperature monitoring and humidity levels will be vital to keeping food fresh in a controlled environment.
Power • AC current Power and electric energy levels will be displayed on the graph using measured AC current locally at the factory,
measure- • Power buildings and industrial equipment. Corresponds to three power systems including two-wire single-phase, three-wire
ment • Integrated power single-phase, or three-wire in three-phase.

Sufficient capacity for data Available battery option


Data Capturing Time Battery Operating Time
Condition Capturing time Condition Example : Condition Operating time Condition Example :
Temp./Humidity sensor (GS-TH), Temp./Humidity sensor (GS-TH),
Built-in memory (Approx. 4.9MB) Approx. 254 days When saving data to the Built-in 1 minute sampling interval,
1 minute sampling interval Approx. 2 weeks
micro SD memory card Over 2 years memory using Alkaline battery (AA size x 2)
* File size for captured data is up to 1.9GB on the micro SD memory card. * USB power source will be required for Voltage/Temperature (GS-4VT), and CO2 sensor (GS-CO2).

Specifications of GL100-N Specifications of input module


Item Description Temperature & Humidity sensor (GS-TH)
Number of channel Up to 4 channels Type of measurement Temperature, and Humidity
(varies by the type of input module used, and measurement type is fixed with each input module.) Accumulated temp. (calculated value), Dew-point temp. (calculated value)
Interface to PC USB 2.0 Measuring range Temperature : -20 to 85 ºC
Functions • Real-time data capturing Humidity : 0 to 100 % RH
• Displays the captured data value to the LCD in real-time and save the monitoring values Acceleration & Temperature sensor (GS-3AT)
• Set conditions using the Menu setting Type of measurement Tri-axial acceleration (X-, Y-, Z-axis), and Temperature
While using USB port : Measuring range Acceleration : ±2G (20 m/s2), ±5G (50 m/s2), ±10G (100 m/s2)
• Output captured data in real-time Temperature : -10 to 50 ºC
• Output the saved data from the internal memory Sampling interval 5 to 100 ms in memory mode, 0.5 s to 60 min. in direct mode (*1)
• Full control of the GL100 from the PC application software Voltage & Thermocouple input terminal (GS-4VT)
Display LCD (backlit monochrome, graphical type) Number of channel Analog voltage 4 channels,
Storage device • Built-in RAM (Approx. 4.9 MB) Logic or Pulse 4 channels (*2)
• micro SD memory card Measuring range Voltage : 20mV to 50V, 1-5V FS
* Maximum file size for captured data is 1.9 GB. Thermocouple: K type (-200 to 1370 ºC) & T type (-200 to 400 ºC)
Sampling interval 0.5 to 30 seconds and 1 to 60 minutes Logic (signal pattern) : 0 to 24 V (common ground)
Output signal Alarm (1channel) Pules (count) : Max. 200 counts/sampling intervall, accumulating up to 65535 counts
Power source • Alkaline battery (AA x 2) Temperature sensor input terminal (GS-4TSR)
• USB bus-power (micro USB connector) Number of channel Sensor 4 channels,
* The required power capacity is 5V, 1A when AC adapter for microUSB drive Logic or Pulse 4 channels(*2)
is used. AC adapter is not included. Sensor Thermistor sensor (optional)
Operating environment Temperature : -10 ºC to 50 ºC Measuring range Temperature: -40 to 120 ºC (varies by the type of sensor)
Humidity : up to 80% RH (non condensed) Logic (signal pattern) : 0 to 24 V (common ground)
Water resistance : IP54 Pulse (count) : Max. 200 counts/sampling interval, accumulating up to 65535 counts
External dimension Approx. 66 x 100 x 27 mm (exclude protrusion) Carbon dioxide (CO2) sensor (GS-CO2)
Weight Approx. 125 g Type of measurement Carbon dioxide concentration
Software Measuring range 0 to 9999 ppm
Item Description Operating environment Temperature : 0 ºC to 50 ºC, Humidity : up to 80% RH (non condensed)
Supported OS Windows : 10 / 8.1 / 8 / 7 (32- or 64-bit) Illuminance & Ultraviolet sensor (GS-LXUV)
Controlled units Up to 10 units Type of measurement Illuminance, and UV intensity
Accumulated Illuminance (calculated value), Accumulated UV intensity (calculated value)
Accessories
Measuring range Illuminance : 0 to 200 klx
Item Model number Description
UV intensity : 0 to 30 mW/cm2
Thermistor sensor (Normal type) GS-103AT-4P Sensor for GS-4TSR module, 3 m, 4 pcs/set, Temp. range : -40 to 105 ºC
AC Current sensor adapter (GS-DPA-AC)
Thermistor sensor (Ultrathin type) GS-103JT-4P Sensor for GS-4TSR module, 3 m, 4 pcs/set, Temp. range : -40 to 120 ºC
Type of measurement Current
AC Current sensor GS-AC50A For GS-DAP-AC module, Cable 200 mm, Current range : 50 A AC
Power (calculated value), Electric energy (calculated value)
AC Current sensor GS-AC100A For GS-DAP-AC module, Cable 200 mm, Current range : 100 A AC
Application circuit Single-phase two-wire, Single-phase three-wire system, or Three-phase three-wire
AC Current sensor GS-AC200A For GS-DAP-AC module, Cable 200 mm, Current range : 200 A AC
Sensor Clamp-on current probe (optional), Two (2) sensors are able to connect
Dual port adapter GS-DPA Connect up to two (2) sensors
Measuring range 50, 100, 200 A RMS (varies by the sensor)
Module Extension Cable GS-EXC Extension cable for input module, 1.5 m long
*1 : Memory capacity is up to 128 k samples in the memory mode.
*2 : The measurement type for analog input channels can each be seperately selected
but also available as set of 4 channels.

• Due to the possibility of equipment or PC failure, the data files on the instrument will not be guaranteed to be held on the memory. Please make a backup of data whenever possible to
avoid data loss.
• Brand names and product names listed in this brochure are the trademarks or registered trademarks of their respective owners.
• Items mentioned are subject to change without notice. For more information about product, please check the web site or contact your local representative.
• Before using it, please read the user manual and then please use it properly in accordance with the description.
For using equipment in correctly and safely • To avoid malfunction or an electric shock by current leakage or voltage, please ensure a ground connection and use according to the specification.

503-10 Shinano-cho, Totsuka-ku, Yokohama 244-8503, Japan


Tel : +81-45-825-6250 Fax : +81-45-825-6396
Email : [email protected]

Website http://www.graphteccorp.com GL100-N_KE10519_6D

You might also like