Milliq Direct Brochure Pb1032en MK
Milliq Direct Brochure Pb1032en MK
Water Purification
System
Pure and ultrapure water
directly from tap water
Pure water
Tap water is first purified to pure (Type 3) water • Unique system adapts to feed water temperature
by reverse osmosis (RO) designed and optimized in order to avoid flow rate decrease during the
using our techniques: wintertime when tap water is colder.
• Progard® pretreatment cartridge validated • Unique safety device ensures that only low ionic
to extend the lifetime of the RO cartridge. permeate water will be sent to the tank in order to
warrant adequate pure water quality and to increase
• Reject recirculation loop recycles reject water
the lifetime of the ion-exchange cartridge used to
treated by the Progard® to minimize tap water usage
produce ultrapure water.
(recovery up to 66%)* and extend Progard® lifetime
while avoiding fouling or scaling issues that might • Complete process monitoring system systematically
shorten the RO cartridge lifetime. checks water temperature, pressure, conductivity and
RO rejection using calibrated meters at different steps.
Ultrapure water
• Water is purified using unique Jetpore® ion-exchange resin, synthetic activated carbon and a
UV lamp to reach a resistivity of 18.2 MΩ.cm at 25°C and a TOC value below
5 ppb; both values are monitored by advanced analytical techniques.
• This water is sent through a small recirculation loop to the Application Pak, where a final
purification step, critical for specific experiments, removes contaminants just before water is
dispensed from the system.
*depending on feed water quality
The pure water produced by reverse osmosis is From the storage tank, water can be sourced
stored in a tank designed to minimize risks of through a front valve, sent by a delivery pump
contamination during water storage. Our tank level to feed instruments such as a glassware washing
sensor will allow the system to automatically start machine, or further processed by the Milli-Q® Direct
or stop producing water when you want it to, and to produce ultrapure (Type 1) water.
will accurately display the tank’s water level on the
system’s screen. Safety devices prevent overflow or
the system from running dry.
2
Convenience in water delivery
Select an Application Pak to get the best-adapted water for your research:
Biopak® Polisher VOC-Pak® Polisher EDS-Pak® Polisher LC-Pak® Polisher Millipak® Filter
Bacteria-free, Water for volatile Water for endocrine Water for ultratrace Bacteria-free and
pyrogen-free and organic compounds disrupters experiments organic analysis particulate-free water
nuclease-free water analysis
3
Milli-Q® Direct System at a glance
Built-in photooxidation
High recovery reverse osmosis for
UV lamp for TOC
pure water production at low cost
reduction and measure
Dispenser removable
from support
Large digital and graphic screen
with detailed procedures for full
Application Pak adapted to online support
specific contaminants removal
Progard® pretreatment
Consistent delivery of ultrapure cartridge to increase RO
quality water adapted to your module lifetime — with e-Sure
needs at low or high flow rate tag for safety and traceability
1 2 4 5 6
12
7
9 10
3
11
19
13
20
16 17
14
18
15
4
Easy access to information
• Simplified and detailed • Clear graphics help you • Critical information, such as set
information (in local language). perform specific tasks such as points or units, is accessible only
maintenance. From the same to the designated responsible
• Alerts and alarms (which can be
screen, you can even print user and is protected by a login
enhanced by a buzzer) are visible
reports on the system’s water and a password.
on the system’s main screen, with
quality and history.
complete information on actions • Automatically stop ultrapure
required. These are accessible water dispense after a fixed time
at the touch of a finger. period set by the user, in order to
avoid water loss or lab flooding.
• Sensors regularly monitor
the operation of the system
to ensure it operates within
specifications. For instance, if
ionic contamination of feed water
exceeds specifications, causing
high conductivity, the built-in
Feed Water Conductivity Meter
will trigger an alarm to alert you.
A Quick Reference Guide located in the door of the Milli-Q® Direct water system provides
all the information required to understand the operation and maintenance of the system.
The system comes with a complete and detailed user manual in 8 languages on CD-ROM.
A printed manual contains essential information (in local language).
5
Easy and reduced maintenance
Progard® pack replacement QPAK® polishing cartridge replacement Millipak® Express 40 replacement
• Progard® pretreatment pack or the QPAK® polishing • The system will alert you to replace consumables
cartridge replacement takes less than 5 minutes. or schedule service visits at least 15 days before
maintenance is actually required.
• Quick and easy traceability thanks to RFID tag,
which automatically registers the catalog and
other new consumables in the system’s memory.
Milli-Q® Services
We provide a comprehensive range of service programs performed by certified field service
engineers to thoroughly maintain and qualify your Milli-Q® system for full compliance with your
industry’s regulatory standards.
Milli-Q® Services can cover all maintenance requirements, such as installation, customized
user training, scientific and technical support, troubleshooting, preventive maintenance visits,
and all validation requirements using ad hoc calibrated equipment, procedures, workbooks and
suitability tests within a GXPs environment.
Safety Certification
The Milli-Q Direct system is tested by an
®
The Milli-Q® Direct system is delivered with
independent and accredited company for a Certificate of Conformity ensuring that it has
compliance with the CE directives related been built and tested fully assembled following
to safety and electromagnetic compatibility. our Standard Operating Procedures, and a
Certificate of Calibration for the temperature and
A certificate is delivered with the system and
resistivity meters built into the system.
the report can be consulted on request at the
manufacturing site. The Milli-Q® Direct consumables are automatically
delivered with a Certificate of Quality.
The Milli-Q® Direct system is built using components
and practices recommended by UL and has been cUL Our manufacturing site is ISO 9001 v.2000 and
marked. The registration can be verified on the UL ISO 140001 certified.
website: www.ul.com.
6
Milli-Q® Direct specifications
Temperature 5 – 35°C
Chlorine < 3 ppm*
Fouling index < 12**
Milli-Q® Direct System Dimensions
Water pH 4 to 10
Connection 1/2 in. Gaz M Parameter Value and Unit
*Feed water chlorine < 1ppm with Progard® T3 and < 3ppm with Progard® T3 + Prepak 1
System footprint 1606 cm² (249 in.²)
**Feed water SDI < 5 with Progard® T3 and < 12 with Progard® T3 + Prepak 1 System height
• Cabinet (base) 497 mm (19.56 in.)
• Dispenser arm (top) 713 mm (28.07 in.)
System width
• Cabinet (base) 332 mm (13.07 in.)
Type 1 Product Water Quality • Dispenser arm (top) 413 mm (16.25 in.)
Automatic dispense volume 100 mL, then 250 mL to 5 L Q-POD® diameter 230 mm (9.05 in.)
by 250 mL increments; 5 L to Dispenser delivery loop length 800 mm (31.49 in.)
60 L by 1 L increments
Q-POD® weight (packaged) 7.2 kg (15.87 lb.)
Volumetric dispense accuracy 3% for volumes between
250 mL and 60 L Q-POD weight (empty)
®
5 kg (11.02 lb.)
Volumetric dispense dispersion CV < 3% for volumes between Q-POD® weight (with water) 5.5 kg (12.12 lb.)
250 mL and 60 L Loop and cable to system length 290 cm (114.1 in.)
Data connection Parallel Port (25-pinD-Sub)
for printout
7
Accessories
Reservoirs
• Select from a range of tank sizes, from 30 L to 200 L,
designed for optimum pure water storage.
Footswitch
• Connect the footswitch to the base of the Q-POD® For more information, please visit our website:
dispenser or directly to the Milli-Q® system for EMDMillipore.com/labwater
hands-free water delivery: press once to start
and once to stop.
To place an order or receive technical assistance in Europe, please call Customer Service:
France: 0825 045 645 Spain: 901 516 645 Option 1
Germany: 069 86798021 Switzerland: 0848 645 645
Italy: 848 845 645 United Kingdom: 0870 900 4645
For other countries across Europe, please call: +44 (0) 115 943 0840
Or visit: MerckMillipore.com/offices
For Technical Service visit:MerckMillipore.com/techservice
© 2020 Merck KGaA, Darmstadt, Germany and/or its affiliates. All Rights Reserved. Merck, the vibrant M, Milli-Q, BioPak,
EDS-Pak, Jetpore, LC-Pak, Millipak, Progard, Q-POD, QPAK and VOC-Pak are trademarks of Merck KGaA, Darmstadt, Merck KGaA
Germany or its affiliates. All other trademarks are the property of their respective owners. Detailed information on
trademarks is available via publicly accessible resources.
Frankfurter Strasse 250
64293 Darmstadt, Germany
PB1032EN00 Ver. 2.0
2017-01253
04/2020 MerckMillipore.com