ABSTRACT OF ESTIMATED COST

Unit
Item
Description of Item Quantity Unit Rate per Amount
no
rate
E/W IN EXCAVATION ,
Earth work in excavation of foundation
trenches or drains, in all sorts of soil
(including mixed soil butexcluding laterite
or sandstone) including removing,
spreading or stacking the spoils within a
lead of 75 m as directed. The item
includes necessary trimming the sides of
1 trenches, levelling,dressing and ramming Cu m 11927 % Cu m
the bottom, bailing out water as required
complete.
(a) Depth of excavation not exceeding
1.5m.
(Ref- item2(a) page-1 PWD)

E/W IN FILLING 1/5 TH OF VALUE OF


EXCAVATION
With earth obtained from excavation of
foundation. Earth work in filling in
foundation trenches or plinthwith good
earth, in layers not exceeding 150
mm.including watering and ramming etc.
2 layer by layer complete. (Payment to be Cu m 11927 % Cu m
made on the basis ofmeasurement of
finished quantity of work)
(Ref- item2(a) page-1 PWD )
SAND FILLING
Filling in foundation or plinth
by silver sand inlayers not exceeding 150
mm as directed and consolidating the
same by thorough saturation withwater,
ramming complete including the cost of
3 Cu m 52107 % Cu m
supplyof sand. (payment to be made on
measurement
offinished quantity) (Ref- item4(a)
page-2 PWD)

Brick flat soling


Single Brick Flat Soling of picked jhama bricks
4 including ramming & dressing bed to proper Sq m 323 Sq m
level & filling joints with local sand.(Ref-
item1 page-14 PWD)

Cement concrete (1:2:4)


Ordinary Cement concrete (mix 1:2:4) with
graded stone chips (20 mm nominal size)
5 excluding shuttering and reinforcement,if Cu m 3710 Cu m
any, in ground floor as per relevant IS codes.
(Ref- item4 page-24 PWD)

BRICKWORK , with 1st Class Brickwork in


cement morter (1:4) In foundation and
6 plinth Cu m 5121 Cu m
(Ref- item7(a) page-15 PWD)

25mm thick damp proof course with


cement concrete with stone chips (1:1.5:3)
[with graded stone aggregate 10 mm
nominal size] and admixture of water
proofing compound as per manufacturer's
specification followed by two coat of polymer
7 based paint, (1st coat after 4 to 5 days of Sq m 194 Sq m
concrete laying and 2 nd coat just before
brick masonry work)
(Ref- item 1 page- 47 PWD)
BRICKWORK , with 1st class brick
incement mortar(1:6) In Superstructure
8 (Ref-item 8(a) page-15, PWD) Cu m 5068 Cu m

Cement concrete with well graded


stonechip
(20 mm graded nominal size) excluding
shuttering and r/fwith complete design of
concrete as per IS:456 relevant special
publications, submission of job mix formula
9 after preliminary mix design after testing of
Cu m 4405 Cu m

concrete cubes as per direction of Engineer-


in charge. In ground floor and foundation. M
20 Grade.
(Ref-item 5(i) page-24, PWD)

Screed Concrete Work(1:2:4)


Ordinary Cement concrete (mix 1:2:4) with
graded stone chips (20 mm nominal size)
excluding shuttering and reinforcement,if
10 any, in ground floor as per relevant IS codes. Cu m 3710 Cu m
(Ref-item 4(a) page-24, PWD)

Reinforcement for reinforced concrete work


in all sorts of structures including distribution
bars, stirrups, binders etc initial straightening and
removal of loose rust, cutting to requisite length,
hooking and bending complete as per drawing
11 and direction For works in foundation and upto Ton 60205 Ton
roof of ground floor Mild Steel
(Ref-item 40.a.i page-44, PWD)
Wood work in Door and Window
frames fitted and fixed in position complete
including a protective coat of painting at the
contact surface of the frame
exluding cost of concrete, Iron Butt Hinges
12 and M.S clamps. Sal : Siliguri. Cu m 81936 Cu m
(Ref-item 1.(a) page-114, PWD)

Panel shutters of door and window , as


per design (each panel consisting of single plank
without joint),including fitting and fixing the
same in position but excluding the cost of hinge
and other fittings. In ground floor 35mm thick
13 shutters with 19mm thick panel of size 30 to 45 Sq m 1619 Sq m
cm (c)Other Local Wood.
(Ref-item 1.iii.(c) page-117, PWD)

25mm thick cement concrete (1;2:4)


floor
finished smooth with neat cement (sq m)
14 sq m 269 sq m
(Ref- item 6(ii) page-48 PWD)

20 mm thick plaster With 1:4 cement


mortar (wall, floor, ceiling etc.) with sand and
cement mortar including rounding off or
chamfering corners as directed and raking out
15 joints including throating, nosing and drip course, Sq m 177 Sq m
scaffolding/staging where necessary
(Ref-item 1.ii.(a) page-189, PWD)

12 mm thick plaster With 1:6 cement


mortar (wall, floor, ceiling etc.) with sand and
cement mortar including rounding off or
chamfering corners as directed and raking out
joints including throating, nosing and drip course,
16 Sq m 138 Sq m
scaffolding/staging where necessary
(Ref-item 1.i.(c) page-189, PWD)
6 mm thick plaster With 1:4 cement
mortar (wall, floor, ceiling etc.) with sand and
cement mortar including rounding off or
chamfering corners as directed and raking out
joints including throating, nosing and drip course,
17 Sq m 125 Sq m
scaffolding/staging where necessary
(Ref-item 1.ii.(c) page-189, PWD)

White washing including cleaning and


smoothening
surface thoroughly three coats inside walls
18 and ceiling (on new works only). Sq m 2001 % Sq m
(Ref-item 1.(c) page-194, PWD)

Colour washing with "ELLA" with a coat of


white wash
priming including cleaning and smoothening
19 surface Sq m 2153 % Sq m
thoroughly : Two coats
(Ref-item 3.i.(b) page-194, PWD)

Painting with oil type wood preservative of


approved
20 brand & make two coats . Sq m 40 Sq m
(Ref-item 8.(b) page-202, PWD)

100 mm dia C.I pipe Lime terracing on roof


with lime concrete(2:2:7) (2 lime putty / paste : 2
surki : 7 brick khoa ) laid to proper slope,
throughly beaten and cured including top
21 finishing, providing ghoondies at junction with Sq m 658 Sq m
parapet etc., shaping and finishing at mouths of
rain water pipes, complete as per direction.
(Ref-item 8.(b) page-202, PWD)

16 mm dia window grating bars


including fitting fixing per drawing and
22 direction For works in foundation and upto roof Ton 60206 Ton
of ground floor Mild Steel
(Ref-item 40.a.i page-44, PWD)
M.S clamp 250 mm long end bifurcated
Labour for fitting and fixing special type M.S
calmp with
necessary wooden packing to Elec. the bolts
23 Each 56 Each
and nuts and one coat of white painting
complete
including dismantling the clamps and depositing
the
same to P.W.D
(Ref-item9 page-273, PWD
Painting with superior quality aluminium paint
of
24 approved make and brand including smoothening Sq m 57 Sq m
surface
(Ref-item 3.b page-201, PWD)
Total
Add 5% contingency
add2.5% water charge
Grand total