2/10/2021 579720

Summary 770B.42/46 continue to log after array is brought up


Status Assigned Severity 3 - Low Code Version 5978.479.479
Responsible Assigned Engineer Product
David Okelly-Lynch David Okelly-Lynch UCODE SSCO
Engineer
Issue Details
Problem Key SFDC number Resolution comment
None None
Update
Problem submitter Closure SFDC
Ray Jing
number

SR # and customer 19949926 - SICHUAN Customer Name(s)


Customer
name(s) Add PROVINCE AIRPORT SICHUAN PROVINCE AIRPORT GROUP. CO., LTD.
Details
GROUP. CO., LTD.

Notes

+ Add/request new update

************ Surge Request ************


FYI the other array CN497800135 at this same dark site had identical issue where it was powered down but
due to CMOS battery issue (020B error) on both directors, it fails the vault restore as NVD is cleared and
NVD vault id is back to 00 instead of 02 as it was before power down. I manually set TOD and the NVD vault
2021-02-07 ID correctly and hard reset the box, vault restore went OK and box is back online.
02:33
020B have been logging on both boards for a while, this array is still pre-production also. CMOS voltage
George Matri on both boards is reported 0.96 on the IPMI SENSORS output.

After online, I ran the 8D,,,ONLD,VTOC and it reported "vtoc_release (0x9) is valid" on both boards.

Both boards are going to be replaced on this array also and sent back for WWFA.

2021-02-07 ************ Surge Request ************


customer another box cn497800136 had similar issue after power down. NVD battery low on both directors
01:59
and internal timer changed to 2016. Vault save was good, recovery G.M assisted to restore. Both
Mingqi Li directors will be sent to WWFA too.

2021-01-22
07:08 awaiting info on vtoc
David Okelly- Severity For Version 5978.479.479 Changed from Medium to Low.
Lynch

************ Surge Response ************


The status of this OPT was changed from RETURNED to ASSIGNED.
2021-01-20 -Both directors have been replaced and WWFAed.
01:38 -Asked CE to collect the output of inline command "8D,,,ONLD,VTOC"
Ray Jing -Will upload logall when i get further update.

For the 770B.42/46


THe Global variable ?vtoc_release? should be correct as of now because IML step 14/b1 after vault restore
2021-01-15 reinitializes it based on GM VTOC info from vault. Can we run inline 8D,,,ONLD,VTOC to verify.
10:09
David Okelly- - vtoc_release (0x9) is VALID
Lynch Problem keys added:
Returned_Gather_Info
Status For Version 5978.479.479 Changed from Assigned to Returned.

2021-01-12 ************ Surge Response ************


20:41 The status of this OPT was changed from RETURNED to ASSIGNED.
Sam Luan We have dispatched the SR to field for both Dirs replacement, and local team will proceed FA.

2021-01-12 Please have both dirs replaced and returned for WWFA.
08:05 Problem keys added:
David Okelly- Returned_Awaiting_Action_Plan_Completion
Lynch Status For Version 5978.479.479 Changed from Assigned to Returned.

2021-01-12
06:45 Assigned Engineer for version 5978.479.479 changed from BLANK to David Okelly-Lynch
David Okelly- Status For Version 5978.479.479 Changed from New to Assigned.
Lynch

✉ SURGE Support
https://surge.isus.emc.com/surge/ViewOPT.php?OPTNum=579720 1/2
2/10/2021 579720

SURGE VMAX_UCODE SSCO_HW/Mem/Platform_Vault Escalation

******** Summary ********


Submitter: [email protected]
Site: SICHUAN PROVINCE AIRPORT GROUP. CO., LTD.
SR #: 19949926
VMAX Version: 5978.479.479
Registered Builds:
MicroCode: 0047
SymmWin: 5029
Epack Id: 8352
Serial Number: CN497800137

Where Found: Customer Site


Escalation Reason: Knowledge Gap
SFDC Number:
Escalate per SFA: No
Immediate Response Required: No
CS recovery engineer email: [email protected]
Severity: 2 - Medium

======== VMAX VMAX_UCODE SSCO_HW/Mem/Platform_Vault Escalation Details ========

*Issue Summary:*
770B.42/46 continue to log after array is brought up

Issue Description:
-250F with 2 Dirs.
-Array was intially running without production.
-The DC suffered a power outage on Jan 9th and soon another one outage(very short interval).
-When checking the array, can see both Dir 1 and 2 are DD with incorrect system time(Showing as 2016
instead of 2021).
-From the 6F,PLOG,TIM1, can see the array was trying to power up twice Aug 3rd 2016(which should be 2021
Jan 9th) but all failed at "restroe_fail" state
-The vault state is restore_fail(11)
-Captured E7,CF at that moment:
D- 1b @[24EFAED80,0] 8000;02;ff;07a0;00000000 00000000 00000000 00010000;
0 ; E7,cf bcm=6

UTILITY E7 -- Display SYSTEM CONFIGURATION info util_e7 : TIME: AUG/07/16 23:35:43 (NTP Time: AUG/07/16
23:35:43)
2021-01-12
EE: CODE: E90D0000; CKSM: 7BE91768; DATE: 03.09.20 10:43 RELEASE: 5978_0479
05:56
CS: CODE: E90D0000; CKSM: 7BE91768; DATE: 03.09.20 10:43 RELEASE: 5978_0479+
Ray Jing ( Saved old_code_release: 5978_0479 )
HWR REV 0; DIR 0x10( 1b); SCU ID: F0; CTL ID: 30; MEMORY SIZE: 215040

POWER ON: AUG/03/16 12:01:07 OPERATING HOURS: 107:35:09


FULL RESET (FF): AUG/03/16 12:01:07 RESET PASSWORD: SR22
ONLINE RESET (FD): AUG/03/16 12:01:07 ERRORS CLEARED:
ERRORS CLEARED: DEC/23/20 10:31:40 SERIAL NUMBER: 000497800137
FULL VTOC TIME: ------------------ CODE VER AT VTOC:
LAST VAULT CHANGE: AUG/03/16 12:02:13
CURR CODE LOAD TIME:AUG/03/16 12:01:33 CURRENT CODE: 5978_0479/0047 (Fixes Tmp:0074 Int:00)
PREV CODE LOAD TIME:------------------ PREVIOUS CODE: ------
2Ago CODE LOAD TIME:------------------ 2 Ago CODE: ------
3Ago CODE LOAD TIME:------------------ 3 Ago CODE: ------

Troubleshooting Steps Performed:


-Firslty see SPS-3A lost communication. reseating the cable fixed the issue.
-Then tried to bring up the array but failed.
-Then see Vault restore failure due to vauld id value mismatch between NVD(0) and Flash slic(2).
-The valud on flash slic is correct. so manually changed the nvd value to 2.
-As director time was changed back to sevearl years back after power loss, ran 8C to change the director
time.
-Then did a hard reset ,now box online.
-However, can still see 770B.42/46(IML ERROR: Illegal vtoc release found in GM/IML ERROR: VTOC RELEASE IN
NVD IS NOT LEGAL ) logging, seems the VTOC time info in NVD was lost during the power loss

Current Impact:
N/A

Expectations of Engineering:
Please confirm if we can safely ignore the 770B.42/46 or should do something to write them back