Sewing Machine Electronic Repairing

Notes

Machine Problem Solutions

First we check all Connectors are connected properly or not


then we replaced each card to see that is problem on
HE-800A-3 Error-44
which card. After replacing we able to know that issue is on
main supply card.

First open body of box and there we find fixed four small
switch. In which
(1) Maximum Speed
Siruba (sew rich without Increasing and Decreasing
(2) intermediate Speed
Display) Speed
(4) For changing Rotation of
Motor (1,2&3) Swich will be off if
lower speed is requires

Normally press Minus/ plus button. And if display not


Feedup the arm\ Danda Increasing and Decreasing
connected first connect display which connection point
Machine (Inter Mach Box) Speed
located at center of module.

HTL When we press button, HTL not Commonly it is problem of relay (220 v 8 pin relay ) simply
(Double Bed Machine) holding the bed. change it.

HTL Simply change the timer and also check if relay working
Timer not setting properly
(Double Bed Machine) properly or not

HTL check is all connection are properly connected and after it


HTL Machine Not heating up
(Double Bed Machine) change heating elements

HTL check relay & timer are working properly and check blue
Bed not laying down
(Double Bed Machine) color hydraulic pressure pipe connected properly

Points that need to be noted:


(1) Sensor Connections ... pin 1 (red wire) ... pin 2
Threading Machine Assembling all parts black wire ...pin4 brown wire
(2) If bearing are not on right place
machine can't fit properly resulting in damage

Check if supply wire is short if problem not solved then


HTL Breaker Trimming when power
check and replace heating elements in 80% cases problem
(Double Bed Machine) on
is in heaters

check is potentiometer working properly or not with


Fabric Rolling Machine with Not increasing decreasing multimeter , check all wire conneted properly or not,check
edge cutter speed relay working or not,if problem not solving change
controler.
check pedal working properly , check pedal connecter
HE-800A-3 Error-30,31,32
connected properly.

80% problem in heat sensor (thermocouple) ,Check all


HTL showing error (HHHH) on PV
thermocouple connections and if needed change
(Double Bed Machine) display
thermocouple

motor not triggering/sensor not


Clipping machine check sensor connection/ change it
working

Page 2 of 2