0% found this document useful (0 votes)
65 views2 pages

RM-9 - User Manual - V1.01

Solar power setup, product installation and operation manual, catalog and datasheet.

Uploaded by

Ram Caceres
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views2 pages

RM-9 - User Manual - V1.01

Solar power setup, product installation and operation manual, catalog and datasheet.

Uploaded by

Ram Caceres
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Manual version: 1.

01 Contents are subject


to changes without prior notice

RM-9
Operation Manual Operation Manual of Liquid
Crystal Display Unit

I. Product features V. Technical parameters


◆ LCD screen designed with backlight.
◆ Support real-time data display and parameter setting. 参数名称 Parameter values
◆ Communication line integrates power supply and communication RM-9
Model
function.
Input voltage 5V-12V
◆ Adopt RS485 communication mode to automatically adapt baud rate
Stand-by power
of the controller. consumption <0.1W
Operation power
◆ The enclosure of magnetic type design is convenient and simple for consumption <0.36W
installation. Communication baud rate 1200-11520bps (9600bps by default)

II. Appearance Communication method RS485

Communication interface RJ45

Cable length 6.0m

Operating temperature -35°C ~+65°C

Protection grade IP32

Weight 90g

Altitude ≤ 3000M

Product dimensions 79*52*32mm

VI. Operation of keys

Button Function
SELECT Menu/parameter switching
III. Installation dimensions ENTER Set/adjust parameters

Parameter setting method


Product dimensions: 79*52*32 mm ①. Press and hold the "ENTER" key for 2 seconds to enter the "Parameter Setting"
Installation dimensions: 67*39 mm menu;
②. Short press the "SELECT" key to select "Setting Item";
③. Short press the "ENTER" key, and the parameter blinks to enter the adjustable
state.
④. Short press the "SELECT" key to adjust the parameter;
⑤. Short press the "ENTER" key to confirm the modified parameter, and repeat ②
to ⑤ to modify other parameters.
⑥. Press and hold the "ENTER" key for 2 seconds, or keep no key pressed for more
than 10 seconds to save and exit the setting mode.

VII. Liquid crystal menu

IV. Installation steps

No. Name No. Name


1 Battery 6 Unit display
2 Inverter indication 7 Setting stage
3 Inverter 8 Setting indication
1. Reserve embedded area (for embedded installation) 4 AC load 9 Parameter display
5 System alarm

2. Open the magnetic upper cover 3. Close the magnetic chuck


and fix it with four M3 screws.
2. Menu browsing
IX. RS485 communication
Main menu Battery voltage

1) Default baud rate: 9,600 kps; check bit: none; data bit: 8 bit; stop bit: 1 bit
2) Interface type: RJ45, communication power supply output specification: 5V/200mA
3) Definition of line sequence:

Output voltage No. Definition


① Communication power supply VCC
② D+
③ D-
System alarm ④ Communication power supply GND
Output current

X. System alarms
Device temperature Operating mode Output frequency Output power

No. System alarm Description


1 E0 Normal
2 E1 Battery over-discharge
3 E2 Battery over-voltage
3. Setting menu
4 E4 Load short-circuited
Output voltage level Output frequency level Battery under-voltage Battery under-voltage recovery
5 E5 Overload
6 E6 Device over-temperature
7 E7 Fan fault
8 E8 Model fault
Clear historical data Battery over-voltage

Factory data reset Battery over-voltage recovery

Device reboot ECO mode starting power

Device address Communication baud rate Temperature unit ECO mode recovery time

VIII. System settings

No. LCD Setting item Parameter range Remarks

110V/120V IU series
1 VAC Output voltage level
220V/230V/240V IC series
2 FAC Output frequency level 50HZ/60HZ
3 LVD Battery over-discharge voltage 10.0~15.0V The 12V system
4 LVR Battery over-discharge reconnect voltage 11.0~15.0V corresponds to this value;
The corresponding value
5 HVD Battery over-voltage 12.0~16.0V for the 24V system is
6 HVR Battery over-voltage recovery 11.0~15.0V multiplied by 2

7 PECO ECO mode starting power 30~100W


8 TECO ECO mode recovery time 30~1800S
9 TEMP Device temperature unit ℃/℉
10 KPS RS485 communication baud rate 1200~115200KPS
11 C001 Device address 1~247
12 F01 Device reboot F01
13 F02 Factory data reset F02
14 F03 Clear historical data F03