AMC CoreWell

AMC Chemwatch Hazard Alert Code: 0


Chemwatch: 30-9920 Issue Date: 01/01/2013
Version No: 2.1.1.1 Print Date: 12/08/2014
Safety Data Sheet S.GHS.CAN.EN

SECTION 1 IDENTIFICATION OF THE SUBSTANCE / MIXTURE AND OF THE COMPANY / UNDERTAKING

Product Identifier
Product name AMC CoreWell

Chemical Name Not Applicable

Proper shipping name Not Applicable

Chemical formula Not Applicable

Other means of identification Not Available

CAS number Not Applicable

Relevant identified uses of the substance or mixture and uses advised against
Relevant identified uses Drilling fluid additive.

Details of the manufacturer/importer


Registered company name AMC

10911 72nd Street SE, Calgary


Address
T2C 3G2 AB Canada

Telephone +1 403 259 5112

Fax +1 403 255 7185

Website www.amcmud.com

Email [email protected]

Emergency telephone number


Association / Organisation Not Available

1-403-888-1956, +61 (0) 432 187


Emergency telephone numbers
374
Other emergency telephone
-
numbers

SECTION 2 HAZARDS IDENTIFICATION

Classification of the substance or mixture

CHEMWATCH HAZARD RATINGS


Chemwatch: 30-9920 Page 2 of 6 Issue Date: 01/01/2013
Version No: 2.1.1.1 Print Date: 12/08/2014
AMC CoreWell

Min Max
Flammability 0
Toxicity 0
0 = Minimum
Body Contact 0 1 = Low
Reactivity 2 = Moderate
0
3 = High
Chronic 0 4 = Extreme

CANADIAN WHMIS SYMBOLS

GHS Classification Not Applicable

Label elements

GHS label elements Not Applicable

SIGNAL WORD NOT APPLICABLE

Hazard statement(s)
Not Applicable

Precautionary statement(s) Prevention


Not Applicable

Precautionary statement(s) Response


Not Applicable

Precautionary statement(s) Storage


Not Applicable

Precautionary statement(s) Disposal


Not Applicable

SECTION 3 COMPOSITION / INFORMATION ON INGREDIENTS

Substances

Mixtures
CAS No %[weight] Name
Not Available 100 Blend of non-hazardous polymers

SECTION 4 FIRST AID MEASURES

Description of first aid measures


If this product comes in contact with eyes:
Wash out immediately with water.
Eye Contact
If irritation continues, seek medical attention.
Removal of contact lenses after an eye injury should only be undertaken by skilled personnel.
If skin or hair contact occurs:
Skin Contact Flush skin and hair with running water (and soap if available).
Seek medical attention in event of irritation.
If dust is inhaled, remove from contaminated area.
Inhalation Encourage patient to blow nose to ensure clear passage of breathing.
If irritation or discomfort persists seek medical attention.

If swallowed do NOT induce vomiting.


If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain open
airway and prevent aspiration.
Observe the patient carefully.
Ingestion
Never give liquid to a person showing signs of being sleepy or with reduced awareness; i.e. becoming
unconscious.
Give water to rinse out mouth, then provide liquid slowly and as much as casualty can comfortably drink.
Seek medical advice.

Indication of any immediate medical attention and special treatment needed


Treat symptomatically.
Chemwatch: 30-9920 Page 3 of 6 Issue Date: 01/01/2013
Version No: 2.1.1.1 Print Date: 12/08/2014
AMC CoreWell

SECTION 5 FIREFIGHTING MEASURES

Extinguishing media
There is no restriction on the type of extinguisher which may be used.

Special hazards arising from the substrate or mixture


Fire Incompatibility None known.

Advice for firefighters


Fire Fighting Alert Fire Brigade and tell them location and nature of hazard.

Fire/Explosion Hazard Non combustible.

SECTION 6 ACCIDENTAL RELEASE MEASURES

Personal precautions, protective equipment and emergency procedures


Minor Spills Clean up all spills immediately.

Major Spills Clear area of personnel and move upwind.

Personal Protective Equipment advice is contained in Section 8 of the MSDS.

SECTION 7 HANDLING AND STORAGE

Precautions for safe handling


Safe handling Limit all unnecessary personal contact.

Other information Store in original containers.

Conditions for safe storage, including any incompatibilities


Suitable container Lined metal can, lined metal pail/ can.

Storage incompatibility Avoid contamination of water, foodstuffs, feed or seed.

PACKAGE MATERIAL INCOMPATIBILITIES


Not Available

SECTION 8 EXPOSURE CONTROLS / PERSONAL PROTECTION

Control parameters

OCCUPATIONAL EXPOSURE LIMITS (OEL)

INGREDIENT DATA
Not Available

EMERGENCY LIMITS

Ingredient TEEL-0 TEEL-1 TEEL-2 TEEL-3


AMC CoreWell Not Available Not Available Not Available

Ingredient Original IDLH Revised IDLH


Blend of non-hazardous polymers Not Available Not Available

Exposure controls
Appropriate engineering
Engineering controls are used to remove a hazard or place a barrier between the worker and the hazard.
controls

Personal protection
Chemwatch: 30-9920 Page 4 of 6 Issue Date: 01/01/2013
Version No: 2.1.1.1 Print Date: 12/08/2014
AMC CoreWell

Safety glasses with side shields


Eye and face protection
Chemical goggles.

Skin protection See Hand protection below


The selection of suitable gloves does not only depend on the material, but also on further marks of quality which
Hands/feet protection
vary from manufacturer to manufacturer.

Body protection See Other protection below

Other protection No special equipment needed when handling small quantities.

Thermal hazards Not Available

Recommended material(s) Respiratory protection


GLOVE SELECTION INDEX
Required
Not Available AMC CoreWell Not Available
Minimum Half-Face Full-Face Powered Air
Protection Respirator Respirator Respirator
Material CPI
Factor
Not Available P1 - PAPR-P1
up to 10 x ES
Air-line* - -
up to 50 x ES Air-line** P2 PAPR-P2
up to 100 x ES - P3 -
Air-line* -
100+ x ES - Air-line** PAPR-P3

* - Negative pressure demand ** - Continuous flow


A(All classes) = Organic vapours, B AUS or B1 = Acid gasses, B2 =
Acid gas or hydrogen cyanide(HCN), B3 = Acid gas or hydrogen
cyanide(HCN), E = Sulfur dioxide(SO2), G = Agricultural chemicals,
K = Ammonia(NH3), Hg = Mercury, NO = Oxides of nitrogen, MB =
Methyl bromide, AX = Low boiling point organic compounds(below
65 degC)

SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES

Information on basic physical and chemical properties


Appearance Off White granular crystals; soluble in water.

Physical state Divided Solid Relative density (Water = 1) Not Available

Partition coefficient n-octanol /


Odour Not Available Not Available
water
Odour threshold Not Available Auto-ignition temperature (°C) Not Applicable

pH (as supplied) 9.0 Decomposition temperature Not Available

Melting point / freezing point


Not Available Viscosity (cSt) Not Applicable
(°C)
Initial boiling point and boiling
Not Available Molecular weight (g/mol) Not Applicable
range (°C)
Flash point (°C) 400 Taste Not Available

Evaporation rate Not Applicable Explosive properties Not Available

Flammability Not Applicable Oxidising properties Not Available

Surface Tension (dyn/cm or


Upper Explosive Limit (%) Not Applicable Not Applicable
mN/m)
Lower Explosive Limit (%) Not Applicable Volatile Component (%vol) Not Available

Vapour pressure (kPa) Not Applicable Gas group Not Available

Solubility in water (g/L) Miscible pH as a solution(1%) Not Available

Vapour density (Air = 1) Not Applicable

SECTION 10 STABILITY AND REACTIVITY

Reactivity See section 7

Chemical stability Product is considered stable and hazardous polymerisation will not occur.
Chemwatch: 30-9920 Page 5 of 6 Issue Date: 01/01/2013
Version No: 2.1.1.1 Print Date: 12/08/2014
AMC CoreWell

Possibility of hazardous
See section 7
reactions

Conditions to avoid See section 7

Incompatible materials See section 7

Hazardous decomposition
See section 5
products

SECTION 11 TOXICOLOGICAL INFORMATION

Information on toxicological effects


The material is not thought to produce adverse health effects or irritation of the respiratory tract (as classified by
Inhaled
EC Directives using animal models).

Ingestion The material has NOT been classified by EC Directives or other classification systems as "harmful by ingestion".

The material is not thought to produce adverse health effects or skin irritation following contact (as classified by
Skin Contact
EC Directives using animal models).

Although the material is not thought to be an irritant (as classified by EC Directives), direct contact with the eye
Eye
may cause transient discomfort characterised by tearing or conjunctival redness (as with windburn).

Chronic Long term exposure to high dust concentrations may cause changes in lung function (i.e. pneumoconiosis) caused
by particles less than 0.5 micron penetrating and remaining in the lung.

TOXICITY IRRITATION
AMC CoreWell
Not Available Not Available

Not available.

Acute Toxicity Carcinogenicity


Skin Irritation/Corrosion Reproductivity

Serious Eye Damage/Irritation STOT - Single Exposure

Respiratory or Skin
STOT - Repeated Exposure
sensitisation
Mutagenicity Aspiration Hazard

CMR STATUS

SECTION 12 ECOLOGICAL INFORMATION

Toxicity
DO NOT discharge into sewer or waterways.

Persistence and degradability


Ingredient Persistence: Water/Soil Persistence: Air
Not Available No Data available for all ingredients No Data available for all ingredients

Bioaccumulative potential
Ingredient Bioaccumulation
Not Available No Data available for all ingredients

Mobility in soil
Ingredient Mobility
Not Available No Data available for all ingredients

SECTION 13 DISPOSAL CONSIDERATIONS

Waste treatment methods


Product / Packaging disposal Recycle wherever possible or consult manufacturer for recycling options.
Chemwatch: 30-9920 Page 6 of 6 Issue Date: 01/01/2013
Version No: 2.1.1.1 Print Date: 12/08/2014
AMC CoreWell

SECTION 14 TRANSPORT INFORMATION

Labels Required
Marine Pollutant: NO

Land transport (TDG): NOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS

Air transport (ICAO-IATA / DGR): NOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS

Sea transport (IMDG-Code / GGVSee): NOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS

Inland waterways transport (ADNR / River Rhine): NOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS
UN number Not Available

Packing group Not Available

UN proper shipping name Not Available

Environmental hazard No relevant data

Transport hazard class(es) Not Available Not Applicable

Classification code Not Available

Limited quantity Not Available


Special precautions for user
Equipment required Not Available
Fire cones number Not Available

SECTION 15 REGULATORY INFORMATION

Safety, health and environmental regulations / legislation specific for the substance or mixture
This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations and the MSDS contains all the information
required by the Controlled Products Regulations.
Not Applicable

SECTION 16 OTHER INFORMATION

Other information
Classification of the preparation and its individual components has drawn on official and authoritative sources as well as independent review by the
Chemwatch Classification committee using available literature references.
A list of reference resources used to assist the committee may be found at:
www.chemwatch.net/references

The (M)SDS is a Hazard Communication tool and should be used to assist in the Risk Assessment. Many factors determine whether the reported Hazards
are Risks in the workplace or other settings. Risks may be determined by reference to Exposures Scenarios. Scale of use, frequency of use and current
or available engineering controls must be considered.

This document is copyright. Apart from any fair dealing for the purposes of private study, research, review or criticism, as permitted under the Copyright
Act, no part may be reproduced by any process without written permission from CHEMWATCH. TEL (+61 3) 9572 4700.

You might also like