Chapter 7: Heating, Ventilation, Air Conditioning (HVAC) 103

CHAPTER 7: HEATING, VENTILATION, AIR


CONDITIONING (HVAC)

When thinking about energy efficiency, one of the most important decisions to be made regarding a new
home is the type of heating and cooling system to install. Equally critical to consider is the selection of
the heating and cooling contractor. The operating efficiency of a system depends as much on proper
installation as it does on the performance rating of the equipment.

Improper design and improper installation of the HVAC system have negative impacts on personal
comfort and on energy bills. Improper design and installation of a HVAC system can dramatically
degrade the quality of air in a home. Poorly designed and poorly installed ducts can create dangerous
conditions that may reduce comfort, degrade indoor air quality, or even threaten the health of the
homeowners.
104 Chapter 7: Heating, Ventilation, Air Conditioning (HVAC)

TYPES OF HEATING SYSTEMS

Keys to obtaining design efficiency of a system in the field include:

 Sizing the system for the specific heating and cooling load of the home being built;
 Proper selection and proper installation of controls;
 Correctly charging the unit with the proper amount of refrigerant;
 Sizing and designing the layout of the ductwork or piping for maximizing energy efficiency; and
 Insulating and sealing all ductwork.

Two types of heating systems are most common in a new home: forced-air or radiant, with forced-air
being used in the majority of the homes. The heat source is either a furnace, which burns a gas, or an
electric heat pump. Furnaces are generally installed with central air conditioners. Heat pumps provide
both heating and cooling. Some heating systems have an integrated water heating system.

FORCED-AIR SYSTEM COMPONENTS

Most new homes have forced-air heating and cooling systems. These systems use a central furnace plus
an air conditioner, or a heat pump. Figure 7-1 shows all the components of a forced-air system. In a
typical system, several of these components are combined into one unit. Forced-air systems utilize a
series of ducts to distribute the conditioned heated or cooled air throughout the home. A blower, located
in a unit called an air handler, forces the conditioned air through the ducts. In many residential systems,
the blower is integral with the furnace enclosure.

Figure 7 – 1 Components of Horizontal Flow Forced-Air Systems


Chapter 7: Heating, Ventilation, Air Conditioning (HVAC) 105

Most homes in Kentucky have a choice of the following approaches for central, forced-air systems; fuel-
fired furnaces with electric air conditioning units, electric heat pumps or a dual fuel system that
combines both a fuel-fired furnace with an electric heat pump. The best system for each home depends on
the cost and efficiency of the equipment, annual energy use, and the local price and availability of energy
sources. In most homes, either type of system, if designed and installed properly, will economically
deliver personal comfort.

RADIANT HEATING SYSTEMS

Radiant heating systems typically combine a central boiler, water heater or heat pump water heater with
piping, to transport steam or hot water into the living area. Heating is delivered to the rooms in the home
via radiators or radiant floor systems, such as radiant slabs or underfloor piping.

Advantages of radiant heating systems include:

 Quieter operation than heating systems that use forced-air blowers.


 Increased personal comfort at lower air temperatures. The higher radiant temperatures of the
radiators or floors allow people to feel warmer at lower air temperatures. Some homeowners, with
radiant heating systems, report being comfortable at room air temperatures of 60°F.
 Better zoning of heat delivered to each room.
 Increased comfort from the heat. Many homeowners, with radiant heating systems, find that the
heating is more comfortable.

Disadvantages of radiant heating systems include:

 Higher installation costs. Radiant systems typically cost 40% to 60% more to install than
comparable forced-air heating systems.
 No provision for cooling the home. The cost of a radiant heating system, combined with central
cooling, would be difficult to justify economically. Some designers of two-story homes have
specified radiant heating systems on the bottom floor and forced-air heating and cooling on the
second floor.
 No filtering of the air. Since the air is not cycled between the system and the house, there is no
filtering of the air.
 Difficulty in locating parts. A choice of dealers may be limited.

HEAT PUMP EQUIPMENT

Heat pumps are designed to move heat from one fluid to another. The fluid inside the home is air and the
fluid outside is either air (air-source), or water (geothermal). In the summer, heat from the inside air is
moved to the outside fluid. In the winter, heat is taken from the outside fluid and moved to the inside air.

AIR-SOURCE HEAT PUMPS

The most common type of heat pump is the air-source heat pump. Most heat pumps operate at least twice
as efficiently as conventional electric resistance heating systems in Climate Zone 4. They have typical
lifetimes of 15 years, compared to 20 years for most furnaces.
106 Chapter 7: Heating, Ventilation, Air Conditioning (HVAC)

Heat pumps use the vapor compression cycle to move heat (see Figure 7-2). A reversing valve allows the
heat pump to work automatically in either heating or cooling mode. The heating process is:

1. The compressor (in the outside unit) pressurizes the refrigerant, which is piped inside.

2. The hot gas enters the inside condensing coil. Room air passes over the coil and is heated. The
refrigerant cools and condenses.

3. The refrigerant, now a pressurized liquid, flows outside to a throttling valve where it
expands to become a cool, low pressure liquid.

4. The outdoor evaporator coil, which serves as the condenser in the cooling process, uses
outside air to boil the cold, liquid refrigerant into a gas. This step completes the cycle.

5. If the outdoor air is so cold that the heat pump cannot adequately heat the home, electric
resistance strip heaters usually provide supplemental heating.

Periodically in winter, the heat pump must switch to a "defrost cycle," which melts any ice that has
formed on the outdoor coil. Packaged systems and room units use the above components in a single box.

Figure 7 – 2 Air Conditioner Vapor Compression Cycle

At outside temperatures of 25°F to 35°F, a properly sized heat pump can no longer meet the entire
heating load of the home. The temperature at which a properly sized heat pump can no longer meet the
heating load is called the balance point. To provide supplemental backup heat, many builders use electric
resistance coils called strip heaters. The strip heaters, located in the air-handling unit, are much more
Chapter 7: Heating, Ventilation, Air Conditioning (HVAC) 107

expensive to operate than the heat pump itself. The strip heaters should not be oversized, as they can
drive up the peak load requirements of the local electric utility.

A staged, heat pump thermostat can be used in concert with multistage strip heaters to minimize strip
heat operation. To overcome this problem, some houses use a dual-fuel system that heats the home with
natural gas or propane when temperatures drop below the balance point.

Air-source heat pumps should have outdoor thermostats, which prevent operation of the strip heaters at
temperatures above 35°F or 40°F. Many mechanical and energy codes require controls to prevent strip
heater operation during weather when the heat pump alone can provide adequate heating.

The proper airflow across the coil is essential for the efficient operation of a heat pump. During
installation, the airflow rate must be checked to ensure that it meets the manufacturer’s
recommendations.

AIR-SOURCE HEAT PUMP EFFICIENCY

The heating efficiency of a heat pump is measured by its Heating Season Performance Factor (HSPF),
which is the ratio of heat provided in Btu per hour to watts of energy used. This factor considers the
losses when the equipment starts up and stops, as well as the energy lost during the defrost cycle.

New heat pumps manufactured after 2005 are required to have an HSPF of at least 7.7. Typical values
for the HSPF are 7.7 for minimum efficiency, 8.0 for medium efficiency, and 8.2 for high efficiency.
Variable speed heat pumps have HSPF ratings as high as 9.0, and geothermal heat pumps have HSPFs
over 10.0. The HSPF averages the performance of heating equipment for a typical winter in the United
States, so the actual efficiency will vary in different climates.

To modify the HSPF for a specific climate, a modeling study was conducted and an equation was
developed that modifies the HSPF, based on the local design winter temperature. In colder climates, the
HSPF declines and in warmer climates, it increases. In Climate Zone 4, the predicted HSPF is
approximately 15% less than the reported HSPF.

GEOTHERMAL HEAT PUMPS

Unlike an air-source heat pump, which has an outside air heat exchanger, a geothermal heat pump relies
on fluid-filled pipes, buried beneath the earth, as a source of heating in winter and cooling in summer,
Figures 7-3, 7-4. In each season, the temperature of the earth is closer to the desired temperature of the
home, so less energy is needed to maintain comfort. Eliminating the outside equipment means higher
efficiency, less maintenance, greater equipment life, no noise, and no inconvenience of having to mow
around that outdoor unit. This is offset by the higher installation cost.
108 Chapter 7: Heating, Ventilation, Air Conditioning (HVAC)

Geothermal Heat Pumps

Figure 7 – 3 Deep Well Loop

Figure 7 – 4 Shallow Trench Loop

There are several types of closed loop designs for piping:

 In deep well systems, a piping loop extends several hundred feet underground.
 Shallow loops are placed in long trenches, typically about 6 feet deep and several hundred feet
long. Coiling the piping into a "slinky" reduces the length requirements.
 For homes located on large private lakes, loops can be installed at the bottom of the lake, which
usually decreases the installation costs and may improve performance.

Proper installation of the geothermal loops is essential for high performance and the longevity of the
system. Choose only qualified professionals, who have several years experience installing geothermal
heat pumps similar to that designed for your home.

Geothermal heat pumps provide longer service than air-source units do. The inside equipment should last
as long as any other traditional heating or cooling system. The buried piping usually has a 25-year
warranty. Most experts believe that the piping will last even longer because it is made of a durable
plastic with heat-sealed connections, and the circulating fluid has an anticorrosive additive.

Geothermal heat pumps cost $1,300 to $2,300 more per ton than conventional air-source heat pumps. The
actual cost varies according to the difficulty of installing the ground loops as well as the size and features
Chapter 7: Heating, Ventilation, Air Conditioning (HVAC) 109

of the equipment. Because of their high installation cost, these units may not be economical for homes
with low heating and cooling needs. However, their lower operating costs, reduced maintenance
requirements, and greater comfort may make them attractive to many homeowners.

GEOTHERMAL HEAT PUMP EFFICIENCY

The heating efficiency of a geothermal heat pump is measured by the Coefficient of Performance (COP),
which measures the number of units of heating or cooling produced by a unit of electricity. The COP is a
more direct measure of efficiency than the HSPF and is used for geothermal heat pumps because the
water temperature is more constant. Manufacturers of geothermal units provide COPs for different
supply water temperatures. If a unit were installed with a COP of 3.0, the system would be operating at
about 300% efficiency.

FURNACE EQUIPMENT

Furnaces burn fuels such as natural gas, propane, and fuel oil to produce heat and provide warm,
comfortable indoor air during cold weather. Furnaces come in a variety of efficiencies. The comparative
economics between heat pumps and furnaces depend on the type of fuel burned, its price, the home’s
design, and the outdoor climate. Recent energy price increases have improved the economics of more
efficient equipment. However, due to the long-term price uncertainty of different forms of energy, it is
difficult to compare furnaces with various fuel types and heat pumps.

FURNACE OPERATION

Furnaces require oxygen for combustion and extra air to vent exhaust gases. Most furnaces are non-direct
vent units—they use the surrounding air for combustion. Others, known as direct vent or uncoupled
furnaces, bring combustion air into the burner area via sealed inlets that extend to outside air.

Direct vent furnaces can be installed within the conditioned area of a home since they do not rely on
inside air for safe operation. Non-direct vent furnaces must receive adequate outside air for combustion
and exhaust venting. The primary concern with non-direct vent units is that a malfunctioning heater
may allow flue gases, which could contain poisonous carbon monoxide, into the area around the furnace.
If there are leaks in the return system, or air leaks between the furnace area and living space, carbon
monoxide could enter habitable areas and cause severe health problems.

Most new furnaces have forced draft exhaust systems, meaning a blower propels exhaust gases out the
flue to the outdoors. Atmospheric furnaces, which have no forced draft fan, are not as common due to
federal efficiency requirements. However, some furnace manufacturers have been able to meet the
efficiency requirements with atmospheric units. Atmospheric furnaces should be isolated from the
conditioned space. Those units located in well ventilated crawl spaces and attics usually have plenty of
combustion air and encounter no problem venting exhaust gases to the outside.

However, units located in closets or mechanical rooms inside the home, or in relatively tight crawl spaces
and basements, may have problems. Furnace mechanical rooms must be well sealed from the other rooms
of the home (see Figure 7-5). The walls, both interior and exterior, should be insulated. Two outside-air
ducts sized for the specific furnace should be installed from outside into the room, one opening near the
floor and another near the ceiling, or as otherwise specified in your locality’s gas code.
110 Chapter 7: Heating, Ventilation, Air Conditioning (HVAC)

MEASURES OF EFFICIENCY FOR FURNACES

The efficiency of a gas furnace is measured by the Annual Fuel Utilization Efficiency (AFUE), a rating
that takes into consideration losses from pilot lights, start-up, and stopping. The minimum AFUE for
most furnaces is now 78%, with efficiencies ranging up to 97% for furnaces with condensing heat
exchangers. The AFUE does not consider the unit’s electricity use for fans and blowers, which can easily
exceed $50 annually. An AFUE rating of 78% means that for every $1.00 worth of fuel used by the unit,
approximately $.78 worth of usable heat is produced. The remaining $.22 worth of energy is lost as waste
heat and exhaust up the flue. Efficiency is highest if the furnace operates for longer periods. Oversized
units run intermittently and have reduced operating efficiencies.

Furnaces with AFUEs of 78% to 87% include components such as electronic ignitions, efficient heat
exchangers, better intake air controls, and induced draft blowers to exhaust combustion products. Models
with efficiencies over 90%, commonly called condensing furnaces, include special secondary heat
exchangers that actually cool flue gases until they partially condense, so that heat losses up the exhaust
pipe are virtually eliminated.
Chapter 7: Heating, Ventilation, Air Conditioning (HVAC) 111

A drain line must be connected to the flue to catch condensate. One advantage of the cooler exhaust gas is
that the flue can be made of plastic pipe rather than metal and can be vented horizontally through a side
wall.

There are a variety of condensing furnaces available. Some rely primarily on the secondary heat
exchanger to increase efficiency, while others, such as the pulse furnace, have revamped the entire
combustion process.

A pulse furnace achieves efficiencies over 90% using a spark plug to explode gases, sending a shock wave
out an exhaust tailpipe. The wave creates suction to draw in more gas through one-way flapper valves,
and the process repeats. Once such a furnace warms up, the spark plug is not needed because the heat of
combustion will ignite the next batch of gas. The biggest problem is noise, so make sure the furnace is
supplied with a good muffler, and do not install the exhaust pipe where any noise will be annoying.

Because of the wide variety of condensing furnaces on the market, compare prices, warranties, and
service. Also, compare the economics carefully with those of moderate efficiency units. Condensing units
may have longer paybacks than expected for energy efficient homes due to reduced heating loads. Table
7-1 compares the break-even investment for high efficiency gas furnaces in Code and in ENERGY STAR®
homes.

Table 7-1 Economic Analysis of Gas Furnaces

Type of Treatment Energy Savings*($/yr)


Break-even Investment‡ ($)
AFUE 0.95 Compared to AFUE 0.80
Code Home 42 477
ENERGY STAR® Home 31 352
*For a system in Lexington, KY
‡See Chapter 2 for information on break-even investment.

ELECTRIC INTEGRATED SYSTEMS

Several products use central heat pumps for water heating, space heating, and air conditioning. These
integrated units are available in both air-source and geothermal models. To be a viable choice, integrated
systems should:

 Have a proven track record in the field;


 Cost about the same, if not less, than comparable separate heating and hot water systems;
 Provide at least a five-year warranty; and
 Be properly sized for both the heating and hot water load.
112 Chapter 7: Heating, Ventilation, Air Conditioning (HVAC)

Make sure the unit is not substantially more expensive than a separate energy efficient heat pump and
electric water heater. Units within $1,500 may provide favorable economic returns.

UNVENTED FUEL-FIRED HEATERS

Unvented heaters that burn natural gas, propane, kerosene, or other fuels are not recommended. While
these devices usually operate without problems, the consequences of a malfunction are life threatening—
they can exhaust carbon monoxide directly into household air. Unvented heaters also can cause serious
moisture problems inside the home.

Most devices come equipped with alarms designed to detect air quality problems. However, many experts
question putting a family at any risk of carbon monoxide poisoning; they see no rationale for bringing
these units into a home (Figure 7-6).

Figure 7-6 Unvented Heater

Examples of unvented units to avoid include:

 Vent-free gas fireplaces. Use sealed combustion, direct vent units instead.
 Room space heaters.

Choose forced draft, direct-vent models instead (Figure 7-7).