Energy Monitoring solution

Improved
efficiency,
more
building value
2
agardio.manager:
enhance energy
efficiency
In today’s world of growing populations and
industrializing economies, electrical energy
is more essential than ever – and so is energy
efficiency. International norms such as
IEC 60364-8-1 have laid the foundation to utilising
electrical energy in the best-possible and most
efficient manner. And this is exactly where our
energy monitoring system comes in. It displays
and clarifies. It provides information. It helps
to interpret this data. And it helps you make
better decisions when it comes to the planning,
installation and day-to-day operation of
low-voltage installations.

Read on to find out how simple the system


is to use and what benefits it offers.

3
One system:
all-encompassing
effect
Energy meters

Multifunction measuring
device for DIN rail

Multifunction
measuring device
for door installation

01
Measure & collect
Linked to Hager Smart meters, the agardio.man-
ager server functions as the brain of our energy
monitoring solution. It measures the consumption
Air Circuit Breaker
of your electrical installations by recording and
querying the activities of connected devices.

- Ideal for Hager devices and


any other modbus devices,
thanks to the plug-in
communication module
- Plug-and-play installation
H3+ MCCB
- Easy configuration
- Integration of third-party devices
such as gas, water or energy meters
- E-mail alerts if limits exceeded.

Third party
modbus devices

4
02
Monitor & analyse
Configure your system on a laptop
or tablet – directly in a web browser,
without the need for extra software.

- Different visualisation methods


(complete application or individual
consumer) for all applications
- All values can be exported in CSV
format for further processing
(e.g.: in Microsoft Excel).

Internet
browser

24 V
Voltage supply
Wi-fi

Energy monitoring server


(Modbus Master)

Data Logger

BACnet/IP

Through the BACnet/IP protocol,


agardio also communicates with
Building Management Systems.

03
Act
Make graphical comparisons and
set alerts so you can intervene when
energy consumption is too high.

5
Small, intelligent – and always up to date with the
current activity of up to 31 Modbus devices:
our new energy monitoring server
agardio.manager.

6
Energy Monitoring server: agardio.manager

The difference
between
guesswork and
knowledge.
The real heart of the system – the agardio.manager –
is rather unassuming. This tiny piece of highly intelligent
technology is just six modules wide. But it packs a real
punch: it records and queries the current activities of up
to 31 Modbus-connected devices – and tells you precisely
where there is potential for optimisation. And you?
You can see instantly where efficiency gains are possible.

Cut operating costs –


replace guesswork
with knowledge.

7
Expanding
intelligence.

Hidden money-wasters, limits being exceeded without your


knowledge, sub-optimal operating conditions – in functional
buildings, it’s worth taking a closer look. We show you
where potential problems lie by measuring current and
output in order to localise expensive consumption peaks.
Or by showing the power factor cos φ in order to introduce
targeted reactive power compensation measures. And what
about the network quality? A detailed look at the voltage
and frequency provides valuable information – permanently.

kWh

Peak load tariff

Base load tariff

Midnight 6 am Midday

8
We ensure energy
transparency and safeguard
network quality by supplying
relevant data from up to 31
connected Modbus devices.

kWh

Midnight Midnight

Clearly presented consumption


diagrams reveal expensive
consumption peaks. You can see
Midnight at a glance how you can save money
by simply changing your usage
habits without reducing overall
energy consumption.

9
Measuring
where it’s
worth it.
Our energy monitoring system keeps a close eye on
the status of all the connected devices: in the main
distributors, the floor distributors and the small
distributors. This means that you are always in a
position to make informed decisions. And you can
respond more quickly. For example, you can set the
system to send you e-mail notifications when limits
are exceeded. You have a range of options to help
you when, for example, grouping applications
according to energy efficiency classes (EIEC) as per
IEC 60364-8.

Simply “plug and play”


to integrate the
appropriate Hager
measurement devices.

10
See where potential exists.
Or the sources of problems.

Final distribution board

Sub distribution board

Main Distribution board

11
Click
and go.

Unpack, connect,
start your browser, go.

12
Energy monitoring is simple. Instead of spending entire
days programming your system, you can carry out
configuration on a laptop or tablet – directly in a web
browser, without the need for extra software or
Modbus mapping tables. In other words, you don’t
need any programming skills or expensive third-party
providers. All compatible measurement devices can
be found in the product catalogue of the energy
monitoring server and can be easily added to the
project. All you have to do is enter the Modbus address
in the server, configure it in the measurement device –
and you’re ready to go!.

One, two, three – Hager


delivers results faster than
you can count.

13
Seeing more
leads to better
decisions.

This is what it’s like to be in the know:


Visualisations by practitioners for
practitioners. Clear, straightforward,
informative. Regardless of where you
are, you obtain valuable information
about energy development and network
quality. Compare current trends with
your history – and only ever rely on
data that is reliable and up to date.
All values can be exported in CSV
format for further processing in,
for example, Microsoft Excel.

14
Now you’ll always be in the picture:
thanks to different visualisation
methods for all the different applications.
The possibilities of visualization include:
- overview,
- current measured values,
- advanced graphical overview,
- historic measured values.

What used to be hidden, is now visible:


through analysis of the network quality,
you can increase system security and
availability. And you can localise the
source of increased harmonic
distortion quickly and easily.

15
Energy Meters:
a complete and
straightforward range
Our new range allows you to save
space in your installation and
to be connected regardless
the measurement rating.

Single phase 40 A 80 A 3 X 80 A

_ _ _

agardio agardio

Three phase 80 A 125 A CT1 / 5 A

_ _ _

agardio agardio agardio

Modbus on RJ45 for


agardio versions Easy to wire with
Hager products

16
Simple and
intuitive menus

Display
Direction of current
of the active
tariff
Total active energy

Partial active
energy

Integrated communication
error detection

The same level All Hager meters enable the


recovery of the following
If required by the ratings,
it is possible to also

of functionality data:
- voltage,
measure more advanced
parameters, such as the

for all meters - current,


- frequency,
reactive and apparent
power and energy
- power factor, measurements, as well
- active energy as measuring the energy
and power. discharged in the network
(exported energy).

All this information is saved by an


internal memory in the meter.

17
Range
overview

Reference ECX140D ECX180D ECX180T

Selection criteria
Connection Single phase 40 A direct Single phase 80 A Single phase 80 A direct
direct (3 track)
Supply voltage 230 V AC 230 V AC 230 V AC
Maximum current Imax 40 A 80 A 3 x 80 A
Precision class, active/reactive Cl.1 / Cl.B // Cl.2 Cl.1 / Cl.B // Cl.2 Cl.1 / Cl.B // Cl.2
Maximum permissible transformer rating - - -
MID certification, required for use MID (depending on MID -
in re-invoicing version)

Connectivity
Not connected ECN140D - -
Pulsed communication ECP140D ECP180D ECP180T
M-bus series communication ECM140D ECM180D ECM180T
RS485 series communication ECR140D ECR180D ECR180T
agardio Modbus communication ECA180D ECA180T

Functions and values recorded


by the product
Current except on ECN140D) • •
Voltage except on ECN140D) • •
Power factor except on ECN140D) • •

Frequency except on ECN140D) • •


Active power except on ECN140D) • •
Apparent power • •
Reactive power • •
Active energy • • •
Apparent energy
Reactive energy • •
Partial resetting of • •
consumption measurements
Energy import/export except on ECN140D • •
Tariff control • •
Number of tariffs managed by: ECN = 0 tariffs up to 8, up to 4, depending on version
physical input / communication ECM = 2 tariffs depending on
ECR = 8 tariffs version
Instrumentation value • • •
I/O function except on ECN140D depending on •
version
Configurable I/O function depending on •
version
Tariff control by physical input except ECA180D •
Tariff control by communication system depending on version depending on depending on version
version
Saved by internal memory • • •

18
ECX380D ECX310D ECX300C

Three phase 80 A direct Three phase 125 A direct Three phase via CT

400 V AC 400 V AC 400 V AC


80 A 125 A 5A
Cl.1 / Cl.B // Cl.2 Cl.1 / Cl.B // Cl.2 Cl.1 / Cl.B // Cl.2
- - 6000 A
MID MID MID

- - -
ECP380D ECP310D ECP300C
ECM380D ECM310D ECM300C
ECR380D ECR310D ECR300C
ECA380D ECA310D ECA300C

• • •
• • •
• • •
• • •
• • •
• • •
• • •
• • •

• • •
• • •

• • •
• • •
up to 8, up to 8, up to 8,
depending on version depending on version depending on version

• • •
• • •

• • •

• • •
depending on version depending on version depending on version

• • •

19
Measurement
unit range

The main functions


A measurement unit enables analysis
of the networks.
It records basic parameters, such as current,
voltage, Cos Phi, power and energy, as well
as harmonic disturbances and the reaction to
different parameters.

Installed at the head of the installation and


in sensitive networks, the measurement unit
provides essential information to check the
operating derivatives of a building.

01 Separate communication and mem-


ory expansion module can be added
subsequently
(on SM102E and SM103E),
02 C onfiguration of the
minimum and maximum thresholds,
03 T ariff level controlled
via communication.

Voltage Type of Rating Communication No. of 17.5 mm modules Package Reference


measure-
ment

400 V AC Indirect 1/5 A Modbus 4 1 pcs SM101C

400 V AC Indirect 1/5 A Pulse (ref. SM200) Built-in 1 pcs SM102E


Modbus RTU (ref. SM210)

400 V AC Indirect 1/5 A Pulse (ref. SM201) Built-in 1 pcs SM103E


Modbus RTU
(ref. SM210 or SM213)
Ethernet
(ref. SM213 or SM214)

20
Function selection guide
Reference SM101C SM102E SM103E

Current • • •

Voltage • • •

Power factor • • •

Frequency • • •

Active power • • •

Apparent power • • •

Reactive power • • •

Active energy • • •

Apparent energy

Reactive energy • • •

Internal clock • • •

Advanced internal clock function • • •

Partial resetting of consumption measurements

Import / export of energy • • •

Tariff control • • •

Instrumentation value

I/O function • • •

Configurable I/O function • • •

Display of previous values

Programming of the maximum demand threshold • • •

Load profile

Management of harmonics • •

Load profile

Alarm function • • •

Recording of measured values per day / week / month

Minimum/maximum demand • • •

Tariff control by physical input • • •

Tariff control by communication system • • •

Tariff control by the clock • • •

Saved by internal memory

21
Current
transformer
range

01 Current transformers
equipped with twin
current socket terminals,
02 R ange dedicated to
measuring the current on
busbars and supply cables.

22
References
Prim. / sec. Precision Power Max. cable Max. size of Type Numerical Commercial
rating diameter supply bar reference reference
50 / 5 A 1% Cl.1 1.5 VA dia. 20 mm 20 x 10 mm BG213 706385 SRA00505
15 x 15 mm
75 / 5 A 1% Cl.1 1.5 VA dia. 28 mm 30 x 10 mm BG113 713929 SRA00755
25 x 15 mm
20 x 20 mm
100 / 5 A 1% Cl.1 2.5 VA dia. 20 mm 20 x 10 mm BG213 725003 SRA010051
15 x 15 mm
125 / 5 A 1% Cl.1 2.5 VA dia. 28 mm 30 x 10 mm BG113 713932 SRA01255
25 x 15 mm
20 x 20 mm
150 / 5 A 1% Cl.1 2.5 VA dia. 28 mm 30 x 10 mm BG113 719933 SRA01505
25 x 15 mm
20 x 20 mm
200 / 5 A 1% Cl.1 2.5 VA dia. 28 mm 30 x 10 mm BG113 713934 SRA02005
25 x 15 mm
20 x 20 mm
250 / 5 A 1% Cl.1 2.5 VA dia. 28 mm 30 x 10 mm BG113 713935 SRA02505
25 x 15 mm
20 x 20 mm
300 / 5 A 1% Cl.1 5 VA dia. 28 mm 40 x 12 mm BG413 706386 SRI03005
400 / 5 A 1% Cl.1 5 VA dia. 28 mm 40 x 12 mm BG413 725000 SRI04005
600 / 5 A 1% Cl.1 5 VA dia. 28 mm 40 x 12 mm BG413 706387 SRI06005
800 / 5 A 1% Cl.1 5 VA dia. 45 mm 60 x 10 mm BG613 713938 SRD08005
50 x 30 mm
1000 / 5 A 5 VA dia. 45 mm 60 x 10 mm BG613 713939 SRD10005
50 x 30 mm
1000 / 5 A 1% Cl.1 15 VA dia. 60 mm 80 x 10 mm BG814 725008 SRE100051
60 x 30 mm
1250 / 5 A 1% Cl.1 15 VA dia. 60 mm 80 x 10 mm BG814 713941 SRE12505
60 x 30 mm
1250 / 5 A 1% Cl.1 15 VA dia. 85 mm 100 x 30 mm BG1034 713944 SRF12505
80 x 50 mm
1500 / 5 A 1% Cl.1 5 VA dia. 45 mm 60 x 10 mm BG613 706388 SRD15005
50 x 30 mm
1600 / 5 A 1% Cl.1 15 VA dia. 60 mm 80 x 10 mm BG814 713942 SRE16005
60 x 30 mm
1600 / 5 A 1% Cl.1 30 VA dia. 85 mm 100 x 30 mm BG1034 713945 SRF16005
80 x 50 mm
2000 / 5 A 1% Cl.1 15 VA dia. 60 mm 80 x 10 mm BG814 713943 SRE20005
60 x 30 mm
2000 / 5 A 1% Cl.1 30 VA dia. 85 mm 100 x 30 mm BG1034 713946 SRF20005
80x50 mm
2500 / 5 A 1% Cl.1 30 VA dia. 85 mm 100 x 30 mm BG1034 713947 SRF25005
80 x 50 mm
3000 / 5 A 1% Cl.1 15 VA dia. 98 mm 120 x 50 mm BG1254 713948 SRG30005
3000 / 5 A 1% Cl.1 15 VA dia. 70 mm 120 x 70 mm BG1274 713950 SRH30005

23
H3+ energy:
Go further with
intelligent and
connected protection
Hager is complying with energy efficiency standards
by adding new functions to its moulded case circuit
breaker range. A Class 1 energy monitoring
and communication system compatible with
the Modbus RTU protocol can be used to
configure the protection parameters, monitor
energy consumption and manage alarms.

Energy performance Secure connection


The h3+ moulded case can be The functions are pre-wired to
coupled with the agardio.manager connectors. The bus connection
multi-energy manager, allowing it to uses an RJ45 connector, which
be integrated in an energy efficiency means there is no risk of incorrect
environment. wiring. The power is supplied from
This allows the energy consumption the tool and no external source is
to be displayed centrally, while required.
complying with the IEC 60364,
NF 15-100 and ISO 50 001 standards.
Class 1 measurement accuracy is
guaranteed.

Service continuity
A specific auxiliary is used to trigger
a fault alarm. This function helps
prevent a total power outage. The user
is notified in advance, allowing the
appropriate action to be taken.

24
01 Integrated pre-alarm contact
02 Colour OLED screen
03 Configurable alarm contact
04 Communication port

Greater flexibility
The moulded case circuit breaker can be
configured via the built-in screen, the panel
display or the configuration tool. In the latter
case, the interface used for configuration does
not need to be installed since the software
operates via the Webserver on your phone,
tablet or PC.

Greater ease of use


Cut programming times for your installation by
up to 80 % with the agardio.manager ecosystem.
Pre-addressing is already done: a library of
products is available in agardio.manager. There
is therefore no need to complete the addressing
table: you need only name the products.

Overview
- Over 200 variants
- Intelligent electronic
tripping
- Breaking capacity up
to 110 kA
- Measured value
acquisition complies
with MID
- Intelligent programming
(h3+ energy only)

01
03 02 africa.hager.com/h3+
- Variants
- Trip units
- Tutorials
- Configuration
04 - Energy monitoring
-A  uxiliary switch
- FAQ
- Hager recommendation

25
A needs-based
approach
TM t (s)

h3+ circuit breakers equipped


with magnetothermal trip units are
designed for power distribution tr
applications. They are used to protect
the conductors and the loads supplied
by the transformers or generators, and
when the fault current is limited due lr li I (A)

to impedance caused by the length of


the conductors. The settings are made
using adjustment dials on the front of
the products.

t (s) LSnI trip unit


Designed to protect networks supplied by
tr transformers or generators and for long cables,
the LSnl version offers a solution adapted to
this type of supply.
tsd

lr lsd li I (A)

LSI

LSI and Energy t (s)

trip unit
h3+ circuit breakers equipped with tr

LSI and Energy trip units are designed I²t


for power distribution applications
for protecting conductors and loads tsd

in cases where a wide range of Settings made using adjustment dials are
lr lsd li I (A)
protection settings is required. accessible on the front of the products, and
enable accurate adjustment of the protection
and a trip curve independent of the ambient
temperature.

26
MAG (ICB) t (s)

h3+ circuit breakers equipped with


magnetic trip units are designed for
use in power distribution applications
in which only magnetic protection
*is required. They are mainly used
to protect motors associated with
li I (A)
a thermal relay and a power switch.

TM, MAG, LSnl, LSI, energy :


five trip unit models designed to
effectively protect your
installations and optimise
the cost of your switchboards.
TM MAG LSnl LSI Energy
P160 P250 P160 P160 P250 P630 P160 P250 P630 P160 P250 P630

Breaking 25, 50 or 50 or 50 or 50 or 70 kA 40, 50, 50 or 70kA 40, 50, 50 or 70 kA 40, 50,


capacity 70 kA 70 kA 70 kA 70, 110 70, 110 70, 110
kA kA kA

Rating 25 - 50 - 25 - 40 - 40 - 250 - 40 - 40 - 250 - 40 - 40 - 250 -


160 A 250 A 160 A 160 A 250 A 630 A 160 A 250 A 630 A 160 A 250 A 630 A

No. of poles (P) 3P3D or 4P4D 3P3D 3P3D or 4P4D 3P3D or 4P4D 3P3D or 4P4D
and trip units (D) 0 or 100 % or 0, 50 or 100 % (N: 0, 50 or 100%) 0, 50 or 100 %
4P4D

RCD add-on No Yes No No Yes Yes No Yes Yes No Yes Yes


block

Configuration Yes
tool

Panel display Yes

Communicating Yes
version

27
Commercial Business

Hager.
A partner
made for
you.
Business and Living
Space Management
Cable Management /
Room Solutions

28
As an expert partner for electrical building
infrastructure with strong expertise in
integrated room solutions, efficient energy
distribution and energy management
solutions as well as cable management
solutions, we listen closely to understand
your special needs.
We advise and deliver on solutions
and services tailored to your individual
requirements.

From hotels to offices and retail – we make


tomorrow’s commercial life and business
places happen.

Energy
Management
Energy
Management Electrical
Infrastructure
Energy
Distribution

29
Our journey
in Africa
Hager Group is a leading provider of solutions
and services for electrical installations in
residential, commercial and industrial buildings.

Our range of solutions and services extends from


energy distribution through cable management
and wiring accessories to building automation
and security systems.

Since 1970, Hager is present in Africa with local


partners with expertise in product management,
sales & marketing and customer services.

Throughout the year our qualified team of


engineers conducts various other trainings on
request. They make sure that these customer-
oriented programs are instrumental in reinforcing
the trust and quality of Hager brand.

With such commitment and dedication, we aim


the best solutions for all your electrical installation
systems anytime, anywhere.

30
Hager Electro S.A.S
132 Boulevard d’Europe BP3
67215 Obernai Cedex
France

Tel: +33 (0) 3 88 49 50 50

africa.hager.com

20EN_AF_BRO_EMONQ