Datasheet

TP5000 Si Range
Programmable Room Thermostat
Features

The TP5000 Si is a microprocessor based constant temperature control if required, again


programmable room thermostat with many this allows the thermostat to be matched with
advanced features. The range includes battery consumers lifestyle.
and 230 volt powered hard-wired models and
battery powered wireless versions. All models Versions with programmable remote inputs are
in the range utilise an advanced PI algorithm to also available. Remote inputs can be either remote
provide close and accurate temperature control to temperature sensing, (control or limit), or digital
reduce energy waste and ensure comfort under all inputs from window contacts, telephone operated
load conditions. switches, card readers or building automation
systems.
The TP5000 Si incorporates a factory set real time
clock, both date and time are set in the factory to For standard applications the product can be
the appropriate time zone, eliminating the need installed and will work straight out of the box,
to set the time at installation or to change the however there is a wide range of user and installer
time in spring or autumn. This function is powered options which allow the product operation to
from a separate lithium battery which lasts for the be tuned to the specification requirements of
lifetime of the product. the system. Some of these options are hardware
settings made by DIL switches, but the majority
The calendar clock is also used to provide a service are software settings made in one of two advanced
due timer function which can be enabled by the programming modes.
installer if required. If enabled, several operating
options are available ranging from audible & visual Settings made by the installer or the end user are
service due warning to proportional reduction of stored for the life of the product in a non-volatile
heating until the boiler is serviced and the service memory chip which does not require power. This
due feature is reset by the installer. same storage technique allows customer specific
programmes to be established as factory defaults,
The TP5000 Si is a 5-day / 2-day programmable but is only available for larger projects.
thermostat which also includes a feature which
allows two blocks of programmes to be set up Significant effort has been made to make the
(A/B Programming), either programme can then product as energy efficient as possible, this
be assigned to any day of the week allowing the includes improving both on/off performance and
programming to closer match the lifestyle of the chrono-proportional performance, charts on page
consumer, all without the need to go for a far 4 detail the relative performance of each mode.
more complex 7-day unit.
Programming of the TP5000 Si is as simple as it has
Unlike earlier models, the TP5000 Si can be always been, just five buttons and an intuitive MMI
configured by the installer to provide 2, 4 or 6 ensure that the product is no more complicated to
events per day, it can also be set up to provide the user than previous models.

© Danfoss HS | 09/2015 | 082v08 VDRMH512 1


Datasheet TP5000 Si Programmable Room Thermostat
Installer Hardware Settings Sw. No. OFF ON
(Switches show factory setting)
1 Keyboard disabled Keyboard enabled

2 Reset disabled Reset enabled

Installer Advanced Option Description Factory Setting Other Setting


Programming Settings User Advanced Programming Options Use + or - key to scroll between options, use Λ or V keys to select option setting
1 Enable/disable A/B block programming 0 Disabled 1 Enabled
0 Disabled
1 Manual time change
3 Automatic summer/winter time change 2 European rules
3 USA rules, post 2006
4 USA rules. pre-2007
Time zone offset - UST models 00:00 Use UST clock setting ± 12 Hours offset from UST
4
Time zone offset - CET models 00:00 Use CET clock setting ± 12 Hours offset from CET
10 Set frost protection default temperature 5 5°C 5-30°C
1 Optimum start control
11 Start-up type 0 Fixed time start-up
2 Delayed start-up
0:15 15 minutes
0:30 30 minutes
Optimum start control setting, maximum 0:45 45 minutes
pre-heat period based upon 2°C deviation
12 1:00 60 minutes 1:15 75 minutes
from next event temperature.
(Only accessible if option 11 is set to 2) 1:30 90 minutes
1:45 105 minutes
2:00 120 minutes
OSC or delay start function active
13 0 First event of day only 1 All events
(Only accessible if option 11 is set to 1 or 2)

Option Description Factory Setting Other Setting


Installer Advanced Programming Options Use + or - key to scroll between options, use Λ or V keys to select option setting
30 Set range upper limit 30°C 40-50°C
31 Set range lower limit 5°C 5-40°C
32 Enable/disable Off function at lower limit 0 Enabled 1 Disabled
33 Enable/disable On function at upper limit 0 Disabled 1 Enabled
3 3 cycles per hour
34 Set chrono-proportional cycle rate 6 6 cycles per hour 9 9 cycles per hour
12 12 cycles per hour
5 5%
35 Set integration time 2.5 2.50%
10 10%
1 Limited to ±2°C
36 Set temperature override limit 0 No limit
2 Disabled, no override
1 1 hour
2 2 hours
37 Set time duration of override 0 Next event
3 3 hours
4 4 hours
38 Relay park status on battery low volt detect 0 Relay parked Off 1 Relay parked On
1 Thermostat mode
40 Number of Events 6 6 Switching events per day 2 2 Switching events per day
4 4 Switching events per day
41 Operating Mode 5-2 5/2 day programming 24 24 Hour programming
70 Keyboard lock type 0 Normal Lock 1 Full lock
Random time on start-up (not battery
71 0 Disabled 1 Enabled
models)
72 Site ID number (user defined) 00 01 to 99
73 Thermostat ID number (user defined) 00 001 to 999
74 Date format for calendar clock 0 European (dd/mm/yy) 1 North American (mm/dd/yy)
81 Thermostat calibration bias 0 ±1.5K
1 Room/duct
Remote sensor configuration
90 0 0, Disabled 2 Limit, (floor)
(A models only)
3 Start-up (digital input)
Limit sensor set point adjustment
93 27°C 20-50°C
(Only accessible if Option 90 is set to 2)
Start-up (digital input) NO or NC NC, open circuit to change NO, close circuit to change to
94 0 1
(Only accessible if Option 90 is set to 3) to thermostat mode thermostat mode

2 © Danfoss HS | 09/2015 | 082v08 VDRMH512


Datasheet TP5000 Si Programmable Room Thermostat
Service Interval Timer The service interval timer allows the installer to Service due date is reached or passed
select a service due date for the boiler, this can When the service due date is reached the visual
be set at between 28 days and 366 days from the and audible warning are repeated each hour of
current date. the day commencing at midday, but the duration
of the alarm is increased to 60 seconds, this can
Service due date is within 28 days be cancelled for the current day by pressing any
From 28 days prior to the service due date, a visual button. All override and programming buttons
warning will appear in the display and a buzzer will are disabled and depending upon service interval
sound for ten seconds each hour commencing at timer setting, heating can be restricted to 15, 30 or
midday, this can be cancelled for the current day 45 minutes in each programmed hour.
by pressing any button.

Option Service Interval Timer Function


Setting 0 Disabled, (factory default)
Setting 1 Active, visual and audible warning, no heat reduction
Setting 2 Active, visual and audible warning, heat reduced to 45 minutes per hour
Setting 3 Active, visual and audible warning, heat reduced to 30 minutes per hour
Setting 4 Active, visual and audible warning, heat reduced to 15 minutes per hour

Specification and Ordering Battery Models 230V Models


Thermostat Features
Hard-wired Wireless Hard-wired
Type TP5000 Si TP5000M Si
Hard-wired, built-in sensor
Sales Code 087N791000 087N791700
Type TP5000A Si TP5000MA Si
Hard-wired, remote sensor inputs (1) (2)
Sales Code 087N791100 087N79800
Type TP5000RF Si
Wireless, built-in sensor
Sales Code 087N791200
Wireless, built-in sensor Type TP5000RF Si + RX1
complete with RX1 receiver (3) Sales Code 087N791400
Type TP5000ARF Si
Wireless, remote sensor
Sales Code 087N791300
5/2 day or 24 hour programmable room thermostat Yes, selectable by installer
2, 4 or 6 events per day with optional A/B programming Yes, selectable by installer
Factory pre-set programmes Yes, one for weekdays, another for weekends
Factory set calendar clock Automatic summer/wintertime change
Time accuracy ± 1 minute per year
Memory back-up, time and all user and installer settings Retained for life of product
Temperature range 5-30°C
Programmable frost thermostat function Yes
Control output, derived from PI algorithm On/Off or Chrono-proportional, 3, 6, 9 or 12 cycles per hour
Switching differential in On/Off mode ±1°C
Installer selectable advanced programming options Yes, refer to installation instructions for list
Installer selectable service interval timer Yes, 28 to 366 days from current date
Programmable range limitation Yes, max and min
Electronic keyboard lock Yes, full or part
Power supply 2 x AA alkaline cells 230V, 50Hz
Switching action of output relay SPDT (voltage free)
Switch rating of output relay 3 (1) A, 10-230V N/A 3(1)A, 10-230V
Transmission frequency (RF models) N/A 433.92MHz N/A
Transmission range (RF models) N/A 30m max. N/A
Dimensions, mm 110 wide x 88 high x 28 deep
Design standard EN60730-2-9, (EN300220 for RF)
(1)
Can be configured by installer for remote temperature sensor, limit sensor, window contact or telephone activated switch contact.
(2)
Remote sensor is supplied as an accessory, if remote room sensor is required order TS2 sensor, code 087N681100
(3)
RX receiver requires 230 volt power supply

ErP Class ERP Class


The products represented within this document are classified according to, and allow completion of, the Energy Related Product
(ErP) Directive System Package fiche and the ErP system data label. ErP Labelling obligation is applicable from 26th September
2015.

ErP Class Product Function and ErP Description Additional efficiency gain

TPI Room Thermostat, for use with on/off output heaters

ErP IV
An electronic room thermostat that controls both thermostat cycle rate
and in-cycle on/off ratio of the heater proportional to room temperature. 2%
Class 4
Product TPI control strategy reduces mean water temperature, improves room
temperature control accuracy and enhances system efficiency.

© Danfoss HS | 09/2015 | 082v08 VDRMH512 3


Datasheet TP5000 Si Programmable Room Thermostat
Wiring TP5000 Si TP5000M Si

S1/D Electronics
S2/E
B C S1 S2
N L D E

N L Remote Input
1 2 3 (TP5000MA Si only)
Please note:
NC NO On230V version the power supply is connected to L and N.
COM
OFF ON

Heating Remote Input


Load (TP5000A Si and
TP5000MA Si only)

1 2 3
NC NO
COM
OFF ON

RX Receiver Wiring (RF Models) Heating


Load
RX1
ELECTRONICS
Remote Input Options

S1/D S1/D S1/D


N L 1 2 3 4 S2/E S2/E S2/E
COM ZONE ZONE
1 ON 1 OFF
Window
contact (NC)

Window or
RX2 & RX3 teleswitch Teleswitch
ELECTRONICS
contact contact (NC)
(NO or NC)
TERMINAL 6
RX3 ONLY

A B C 1 2 3 4 5 6 Configured for Configured for Configured for


remote room window contact or window contact
N L COM ZONE ZONE ZONE
sensor or limit other contact such and other contact
ZONE
1 ON 1 OFF 2 ON 3 ON

1) For mains voltage operated systems link terminal 2 to mains live supply. sensor as teleswitch such as teleswitch
2) Power supply to unit must not be switched by timeswitch.

Thermal Performance 22

21
22

21

20 20

19 19

18 18
Room Temperature (C)

Room Temperature (C)

17 17

16 16

15 15

14 14

13 On/Off Control 13

12 12 Chrono-Proportional Control
(Chrono 6)
11 11

10 10
0 1 2 3 4 5 6 7 8 9 10 11 12 0 1 2 3 4 5 6 7 8 9 10 11 12
Time (Hours) Time (Hours)

Danfoss Ltd.
Ampthill Road
Bedford MK42 9ER
Tel: 01234 364621
Fax: 01234 219705
Email: [email protected]
Website: www.heating.danfoss.co.uk
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already
on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

4 © Danfoss HS | 09/2015 | 082v08 VDRMH512