Blue-White

q
CHEM-FEED Diaphragm Metering Pumps
Industries, Ltd. Engineering and Technical Data

C-600P
Fixed Speed
Mechanical Cam
Output Adjustment

Features:
! All ball bearing, permanently lubricated gear motor for ! Stroke adjustment from 4-100% permits accurate small
smooth, quiet, powerful operation. injections at a high rate per minute. 27:1 turndown
! Double-ball inlet and outlet cartridge type ceramic check ! PTFE coated EP diaphragm.
valves. Chemical resistant PVDF pump head, valve body and ! Durable metal epoxy coated construction.
fittings, ceramic balls, Viton static seals and TFE/P ball seat o- ! PVDF suction (foot) valve with Viton and TFE/P o-rings,
rings. No metal springs are used. ceramic check ball and removable polypropylene filter
! Outputs to 516 GPD. screen.
! Output pressures to 125 PSI. ! Includes 3/8” OD suction and discharge tubing, Injection
fitting with spring-loaded check valve and all mounting

Specifications:
Max. working pressure: ........125 psig (8.6 bar) Voltage (amp draw): ..............115VAC/60Hz, 1ph (.74 amp max)
Max. fluid temperature: ........130o F (54o C) 230VAC/60Hz, 1ph (.36 amp max)
Max. ambient temperature: ..14o to 110o F/ -10o to 43o C 220VAC/50Hz, 1ph (.31 amp max)
Maximum viscosity: ..............1,000 Centipoise 24VAC/60Hz, 1ph (3.40 amp max)
Maximum suction lift: ...........10 ft. Water 0 psig 12VDC (3.00 amp max)
Output adjustment range: ....4-100% stroke length 24VDC (1.50 amp max)
Duty cycle:.............................Continuous Power Connection: ...............Junction box for field wiring
Enclosure: .............................NEMA type 1, (IP20) Approximate shipping wt: ...8 lb. (3.6 kg)

Materials of Construction:
Wetted components:
Pump Head: ...........................PVDF (options: PTFE, Acrylic) Suction Footvalve/Strainer:
Pump Head Inlet/outlet Valves: Body & Tubing adapter:.....PVDF (optional PTFE)
Cartridge valve body: ........PVDF Strainer: .............................Polypropylene
Tube adapters: ...................PVDF Check Ball: .........................Ceramic (optional PTFE poppet)
Check Balls: .......................Ceramic Ball Seat O-ring:.................TFE/P (optional EP)
Ball Seat O-ring:.................TFE/P (optional EP) Static Seal O-ring: ..............Vitonq (optional EP)
Static Seal O-ring: ..............Vitonq (optional EP) Injection/Check valve:
Suction Tubing:.....................Clear PVC Body & insert: ....................Polypropylene (optional PVDF, PTFE)
Discharge Tubing:.................Natural Polyethylene (LLDPE) Check Ball: .........................Ceramic (optional PTFE poppet)
Spring: ................................Hastelloy C-276
Ball Seat O-ring:.................TFE/P (optional EP)
Static Seal O-ring: ..............Vitonq (optional EP)
Blue-White Industries, Ltd.
q
CHEM-FEED Diaphragm Metering Pumps

Dimensions:
7-7/32” 6-3/4” 5-5/16”
183mm 171.5mm 134.9mm

23 4
6-1/4” 6-1/4”
0 1
158.8mm 158.8mm

DC POWERED MODELS AC POWERED MODELS

Model Number Matrix:


MODEL C-6 P -
Maximum Motor RPM
14 = 14 RPM 60 = 60 RPM
30 = 30 RPM 125 = 125 RPM
45 = 45 RPM 250 = 250 RPM
Pump Head / Wet Parts
P = Heavy duty cartridge style polypropylene head
HV = High volume output acrylic head
Power Supply Voltage
115VAC = 115V60Hz
220VAC = 220V50Hz (20% less output)
230VAC = 230V60Hz
24VAC = 24V60Hz
12VDC = 12V DC
24VDC = 24V DC

Flow rate and pressure capacities:


AC powered models:
Max Output at 0 PSI Strokes Max 115V/60Hz 230V/60Hz 220V/50Hz*
GPD GPH LPH OZ/MIN Per minute PSI Model Number Model Number Model Number
24 1.0 3.8 2.7 14 125 C-614P-115VAC C-614P-230VAC C-614P-220VAC
58 2.4 9.3 5.2 30 125 C-630P-115VAC C-630P-230VAC C-630P-220VAC
91 3.8 14.9 8.1 45 80 C-645P-115VAC C-645P-230VAC C-645P-220VAC
110 4.6 17.4 9.8 60 60 C-660P-115VAC C-660P-230VAC C-660P-220VAC
237 9.9 37.0 21.1 125 30 C-6125P-115VAC C-6125P-230VAC C-6125P-220VAC
389 16.2 61.4 34.6 250 10 C-6250P-115VAC C-6250P-230VAC C-6250P-220VAC
* Note: 220V/50Hz models deliver approximately 20% less output.

Maximum Output vs. Pressure Curve


DC powered models:
Max Output at 0 PSI 18.5 39.4
Strokes Max 12V DC 24V DC
GPD GPH LPH OZ/MIN Per minute PSI Model Number Model Number
15.9 C6250P
33.8
33 1.4 5.3 2.9 14 125 C-614P-12VDC C-614P-24VDC
OUTPUT (oz/min)

74 3.1 11.7 6.5 30 125 C-630P-12VDC C-630P-24VDC


OUTPUT (GPH)

13.2 28.1
112 4.7 17.8 10.0 45 80 C-645P-12VDC C-645P-24VDC
148 6.2 23.5 13.2 60 60 C-660P-12VDC C-660P-24VDC 10.6 22.5
316 13.2 49.9 28.1 125 30 C-6125P-12VDC C-6125P-24VDC C6125P

516 21.5 81.4 45.8 250 10 C-6250P-12VDC C-6250P-24VDC 7.9 16.9

5.3 11.2
C660P
C645P
2.6 C630P 5.6
C614P
0 0
0 25 50 75 100 125
OUTPUT PRESSURE (p.s.i.g)

Blue-White Industries, Ltd.


R
5300 Business Drive, Huntington Beach, CA 92649
Tel: 714-893-8529 Fax: 714-894-9492 All trademarks are the property of their respective owners.
Technical data sheet #85000-055 rev.072911