Digital Timer (DIN□48)

LT4H / LT4H-L

48 48
1.890 1.890

64.5 64.5
48 2.539 48 2.539
1.890 1.890
mm inch mm inch

Pin type Screw terminal type

2022.7
* For the latest information, please visit our company website.
DIN 48 SIZE LT4H/-L
DIGITAL TIMER
Timers
LT4H Timers UL File No.: E122222
C-UL File No.: E122222
Features
1. Bright and Easy-to-Read Display 5. Screw terminal (M3.5) and Pin
A brand new bright 2-color back light Types are Both Standard Options
LCD display. The easy-to-read screen in The two terminal types are standard
48
1.890 any location makes checking and setting options to support either front panel
procedures a cinch. installation or embedded installation.
2. Simple Operation 6. Changeable Panel Cover
Seesaw buttons make operating the unit Also offers a black panel cover to meet
64.5
48 2.539 even easier than before. your design considerations.
1.890
mm inch 3. Short Body of only 64.5 mm 2.539 7. Compliant with UL, c-UL and CE.
inch (screw terminal type) or 70.1 mm
2.760 inch (pin type)
With a short body, it is easy to install in
even narrow control panels.
4. Conforms to IP66’s Weather
Pin type Screw terminal type Resistant Standards
The water-proof panel keeps out water
and dirt for reliable operation even in
poor environments.

Product types
Time range Operating mode Output Operating voltage Power down insurance Terminal type Part number
8 pins LT4H8-AC240V
100 to 240 V AC 11 pins LT4H-AC240V
Screw terminal LT4H-AC240VS
8 pins LT4H8-AC24V
Relay
24 V AC 11 pins LT4H-AC24V
(1 c)
Screw terminal LT4H-AC24VS
Power ON delay (1) 8 pins LT4H8-DC24V
9.999 s (0.001 s~)
Power ON delay (2)
99.99 s (0.01 s~) 12 to 24 V DC 11 pins LT4H-DC24V
Signal ON delay
999.9 s (0.1 s~)
Signal OFF delay Screw terminal LT4H-DC24VS
9999 s (1 s~)
Pulse One-shot Available
99 min 59 s (1 s~) 8 pins LT4HT8-AC240V
Pulse ON-delay
999.9 min (0.1 min~)
Signal Flicker 100 to 240 V AC 11 pins LT4HT-AC240V
99 h 59 min (1 min~)
Totalizing ON-delay
999.9 h (0.1 h~) Screw terminal LT4HT-AC240VS
(8 modes)
8 pins LT4HT8-AC24V
Transistor
24 V AC 11 pins LT4HT-AC24V
(1 a)
Screw terminal LT4HT-AC24VS
8 pins LT4HT8-DC24V
12 to 24 V DC 11 pins LT4HT-DC24V
Screw terminal LT4HT-DC24VS
* A rubber gasket (ATC18002) and a mounting frame (AT8-DA4) are included.
LT4H/-L
LT4H-L Timers UL File No.: E122222
C-UL File No.: E122222
Features
1. Economically priced in anticipation 4. Compliant with UL, c-UL and CE.
of market needs.
• Economically priced to provide
excellent cost performance.
2. Display is a bright reflective-type
48
1.890 LCD.
3. Inherits all of the characteristics of
the LT4H digital timer.
• Seesaw switches ensure easy
64.5
48 2.539 operation.
1.890
mm inch • IP66 environmental protection.
• Shortened body (70.1 mm 2.760 inch
underhead).

Product types
Power down
Product name Time range Operating mode Output Operating voltage Terminal type Part number
insurance
Power ON delay (1) 100 to 240 V AC LT4HL8-AC240V
9.999 s (0.001 s~)
Power ON delay (2) Relay
99.99 s (0.01 s~) 24 V AC/DC LT4HL8-AC24V
Signal ON delay (1 c)
999.9 s (0.1 s~)
Signal OFF delay 12 to 24 V DC LT4HL8-DC24V
LT4H-L 9999 s (1 s~)
Pulse One-shot Available 8 pins
digital timer 99 min 59 s (1 s~) 100 to 240 V AC LT4HLT8-AC240V
Pulse ON-delay
999.9 min (0.1 min~)
Signal Flicker Transistor
99 h 59 min (1 min~) 24 V AC/DC LT4HLT8-AC24V
Totalizing ON-delay (1 a)
999.9 h (0.1 h~)
(8 modes) 12 to 24 V DC LT4HLT8-DC24V

Part names
Time delay indicator (Countdown time display) DIP switches
TIMER
Elapsed time display

ON
1 2 3 4 5 6 7 8

Controlled output indicator


Set time display
OP.
Reset indicator RST
LOCK h m s

Lock indicator Time units display


UP
RESET
Up keys
Reset switch LOCK
Down keys
Lock switch LT4H DOWN
(Same for screw terminal type and 8-pin type)
LT4H/-L
Specifications
Type Ralay output type Transistor output type
Item AC type AC/DC type DC type AC type AC/DC type DC type
100 to 240 V AC, 24 V AC, 100 to 240 V AC, 24 V AC,
Rated operating voltage 12 to 24 V DC 12 to 24 V DC
24 V AC/DC 24 V AC/DC
Rated frequency 50/60 Hz common — 50/60 Hz common —
Rated power consumption Max. 10 V A Max. 3 W Max. 10 V A Max. 3 W
Rated control capacity 5 A, 250 V AC (resistive load) 100 mA, 30 V DC
Time range 9.999 s, 99.99 s, 999.9 s, 9999 s, 99 min 59 s, 999.9 min, 99 h 59 min, 999.9 h (selected by DIP switch)
Addition (UP)/Subtraction (DOWN)
Time counting direction
(2 directions selectable by DIP switch)
Rating A (Power ON delay 1), A2 (Power ON delay 2), B (Signal ON delay), C (Signal OFF delay), D (Pulse one-shot),
Operation mode
E (Pulse ON delay), F (Signal Flicker), G (Totalizing ON delay) (selectable by DIP switch)
Start/Reset/Stop input Min. input signal width: 1 ms, 20 ms (2 directions by selected by DIP switch) (The 8-pin type does not have a stop input.)
Lock input Min. input signal width: 20 ms (The 8-pin type does not have a lock input.)
Open collector input Input impedance: Max. 1 kΩ; Residual voltage: Max. 2 V
Input signal
Open impedance: 100kΩ or less, Max. energized voltage: 40V DC
Indication 7-segment LCD (LT4H, LT4H-L common), Elapsed value (backlight red LED), Setting value (backlight yellow LED)
Power failure memory
EEP-ROM (Min. 105 overwriting)
method
Operating time fluctuation
Time
accuracy
(max.)
Temperature error
Voltage error
Setting error
± (0.005 % + 50 ms) in case of power on start
± (0.005 % + 20 ms) in case of input signal start [ Operating voltage: 85 to 110%
Temperature: –10 to +55°C +14 to +131°F
Min. input signal width: 1ms
]
Contact arrangement Timed-out 1 Form C Timed-out 1 Form A (Open collector)
Contact Contact resistance (Initial value) 100 mΩ (at 1 A 6 V DC) —
Contact material Ag alloy/Au flash —
Mechanical (contact) Min. 2 × 107 ope. (Except for switch operation parts) —
Life
Electrical (contact) 1.0 × 10 ope. (At rated control voltage)
5
Min. 10 ope. (At rated control voltage)
7

Allowable operating voltage range 85 to 110 % of rated operating voltage


2,000 Vrms for 1 min: Between live and dead metal parts (11-pin)
Breakdown voltage 2,000 Vrms for 1 min: Between live and dead metal parts (Pin type)
2,000 Vrms for 1 min: Between input and output
(Initial value) 2,000 Vrms for 1 min: Between input and output
1,000 Vrms for 1 min: Between contacts
Between live and dead metal parts Min. 100 MΩ: Between live and dead metal parts
Insulation resistance (At 500V DC)
Electrical Min. 100 MΩ: Between input and output (At 500V DC) Between input and output
(Initial value)
Between contacts
Operating voltage reset
Max. 0.5 s
time
Max. 65° C
Temperature rise —
(under the flow of nominal operating current at nominal voltage)
Vibration Functional 10 to 55 Hz: 1 cycle/min single amplitude of 0.35 mm .014 inch (10 min on 3 axes)
resistance Destructive 10 to 55 Hz: 1 cycle/min single amplitude of 0.75 mm .030 inch (1 h on 3 axes)
Mechanical
Shock Functional Min. 98 m 321.522 ft./s2 (4 times on 3 axes)
resistance Destructive Min. 294 m 964.567 ft./s2 (5 times on 3 axes)
Ambient temperature –10° C to 55° C +14° F to +131° F
Operating Ambient humidity Max. 85 % RH (non-condensing)
conditions Air pressure 860 to 1,060 h Pa
Ripple rate — 20 % or less — 20 % or less
Connection 8-pin/11-pin/screw terminal
Protective construction IP66 (front panel with rubber gasket)

Applicable standard
Safety standard EN61812-1 Pollution Degree 2/Overvoltage Category II
(EMI)EN61000-6-4
Radiation interference electric field strength EN55011 Group1 ClassA
Noise terminal voltage EN55011 Group1 ClassA
(EMS)EN61000-6-2
Static discharge immunity EN61000-4-2 4 kV contact
8 kV air
RF electromagnetic field immunity EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz)
10 V/m pulse modulation (895 MHz to 905 MHz)
EMC EFT/B immunity EN61000-4-4 2 kV (power supply line)
1 kV (signal line)
Surge immunity EN61000-4-5 1 kV (power line)
Conductivity noise immunity EN61000-4-6 10 V/m AM modulation (0.15 MHz to 80 MHz)
Power frequency magnetic field immunity EN61000-4-8 30 A/m (50 Hz)
Voltage dip/Instantaneous stop/Voltage fluctuation immunity EN61000-4-11 10 ms, 30% (rated voltage)
100 ms, 60% (rated voltage)
1,000 ms, 60% (rated voltage)
5,000 ms, 95% (rated voltage)
LT4H/-L
Dimensions (units: mm inch)
Tolerance: ±1.0 ±.039
• LT4H digital timer
Screw terminal type Pin type
(Flush mount) (Flush mount/Surface mount)
48 5.5 64.5 5.5 55.6 14.5
1.890 .217 2.539 .217 2.189 .571

TIMER

OP.
RST 44.5 44.5
LOCK h m s 1.752 1.752
RESET UP

LOCK

LT4H DOWN

7.5 7.5
.295 .295

• Dimensions for embedded installation (with adapter installed)


Screw terminal type Pin type
Rubber gasket Panel Mounting frame Rubber gasket Panel Mounting frame 8-pin type
for flush mount for flush mount (8p cap AD8-RC
ATC18002 (supplied) ATC18002 (supplied)
AT8-DA4 (supplied) AT8-DA4 (supplied) sold separately)
11-pin type
TIMER TIMER (11p cap AT8-DP11
sold separately)

OP. OP.
48 RST 50 66 44.5 48 RST 50 66
1.890 LOCK h m s 1.969 2.598 1.752 1.890 LOCK h m s 1.969 2.598
RESET UP RESET UP

LOCK LOCK

LT4H DOWN LT4H DOWN

48 1 63.5 48 1 90
1.890 .039 2.500 1.890 .039 3.543

• Dimensions for front panel installations • Installation panel cut-out dimensions • For connected installations
The standard panel cut-out dimensions are shown
DIN rail terminal block below. Use the mounting frame (AT8-DA4) and rub-
45+0.6
0
(8-pin type AT8-DF8K ber gasket (ATC18002). 1.772+.024
0
sold separately)
(11-pin type AT8-DF11K 80 min.
sold separately) 3.150
45+0.6
0 1.772+.024
0 A
+0.6
A = (48 × n – 2.5) 0
+0.6
Device installation rail 45 0
+.024
AT8-DLA1 1.772 0

(sold separately) Note) 1: The installation panel thickness should be between 1


80 min.
3.150 and 5 mm .039 and .197 inch.
95.5
(90.0) Note) 2: For connected installations, the waterproofing ability
3.760 between the unit and installation panel is lost.
(3.543) ( ) dimension is for 8-pin type.

Terminal layouts and Wiring diagrams


• 8-pin type • 11-pin type
Relay output type Transistor output type Relay output type Transistor output type
N.C. Reset Reset
Start
Start Start N.C. Start
N.O.
Stop Stop
Reset 4 5 Reset 4 5 5 6 7 N.O. 5 6 7
6 Lock Lock
3 6 3 4 8 4 8
3 9 3 9
2 7 2 7 2 10 2 10
1 8 1 8 1 11 1 11
Operating Operating Operating Operating
– voltage + – voltage + –
– voltage + voltage +

• Screw terminal type


Relay output type Transistor output type
Reset Reset
Start Start
Stop Stop
Lock N.O. Lock
6 7 8 9 10 6 7 8 9 10
N.C.

1 2 3 4 5 1 2 3 4 5
Note) For connecting the output leads of the transistor output type, refer to
Operating Operating 5) Transistor output on page 48.
+ voltage – + voltage –
LT4H/-L
Setting the operation mode, time range, and time
Setting procedure 1) Setting the operation mode and time range
Set the operation mode and time range with the DIP switches on the side of the LT4H timer.
DIP switches Table 1: Setting the operation mode
DIP switch DIP switch No.
Item Operation mode
OFF ON 1 2 3
1 ON ON ON A: Power on delay 1
2 Operation mode Refer to table 1 OFF OFF OFF A2: Power on delay 2
3 ON OFF OFF B: Signal on delay
Minimum input reset, start, and OFF ON OFF C: Signal off delay
*4 20 ms 1 ms
stop signal width ON ON OFF D: Pulse One shot
5 Time delay direction Addition Subtraction OFF OFF ON E: Pulse On delay
6 ON OFF ON F: Signal Flicker
7 Time range Refer to table 2 OFF ON ON G: Totalizing On delay
8
* The 8-pin type does not have the stop input, so that the dip
Table 2: Setting the time range
switch can be changed over between reset and start inputs. DIP switch No.
Time range
The signal range of the lock input is fixed (minimum 20 ms). 6 7 8
ON ON ON 0.001 s to 9.999 s
DIP switches OFF OFF OFF 0.01 s to 99.99 s
ON OFF OFF 0.1 s to 999.9 s
ON

1 2 3 4 5 6 7 8

OFF ON OFF 1 s to 9999 s


ON ON OFF 0 min 01 s to 99 min 59 s
OFF OFF ON 0.1 min to 999.9 min
ON OFF ON 0 h 01 min to 99 h 59 min
OFF ON ON 0.1 h to 999.9 h
(Same for screw terminal type) Notes: 1) Set the DIP switches before installing the timer.
2) When the DIP SW setting is changed, turn off the power once.
3) The DIP switches are set as ON before shipping.

Setting procedure 2) Setting the time


Set the set time with the keys (UP and DOWN keys) on the front of the LT4H timer.
Front display section
Q Elapsed time display 3 I UP keys
W Set time display TIMER Changes the corresponding digit of the
1
E Time delay indicator set time in the addition direction
4 2
R Controlled output indicator (upwards)
OP.
T Reset indicator 5 RST O DOWN keys
LOCK h m s
Y Lock indicator Changes the corresponding digit of the
6 7
UP set time in the subtraction direction
U Time units display 10
RESET
8
LOCK
(downwards)
11 9 P RESET switch
LT4H DOWN
Resets the elapsed time and the output
{ LOCK switch
Locks the operation of all keys on the unit
• Changing the set time
1. It is possible to change the set time is changed to a time above the elapsed delay 2), the output will turn on when the
with the up and down keys even dur- time, the time delay will continue until the power supply is turned on. However, the
ing time delay with the timer. elapsed time reaches the new set time. output will be off while reset is being
However, be aware of the following 2) If the time delay is set to the subtrac- input.
points. tion direction, time delay will continue 2) In the other modes, the output turns
1) If the set time is changed to less than until “0” regardless of the new set time. on when the start is input. When the
the elapsed time with the time delay set 2. If the set time is changed to “0,” the operation mode is C (signal off delay), D
to the addition direction, time delay will unit will operate differently depending (Pulse one shot), or F (Signal flicker),
continue until the elapsed time reaches on the operation mode. only when the start input is on does the
full scale, returns to zero, and then 1) If the operation mode is set to A output turn on. Also, when the reset is
reaches the new set time. If the set time (power on delay 1) or A2 (power on being input, the output is off.
• Power failure memory
The EEPROM is used for power failure memory. It has a life of Min. 105 over-writings.
The EEPROM is overwriting with the following timing.
Output mode Overwrite timing
Power ON delay (2) A2 When power is OFF
Addition G Change of preset value or start, reset input
When power is OFF after being ON
Other modes When power is OFF after changing preset value
* Be aware that the contents of EEPROM for all modes will be overwritten when power is turned OFF during input to external lock terminals R to E and 7 to 6 .
Such an action does not exist by doing lock operation from the front.
LT4H/-L
Operation mode T: Set time t1, t2, t3, ta<T

Operation type Explanation Time chart


• Set the operation mode 1 2 3
section of the DIP switches
ON ON ON
(no.’s 1, 2, and 3) on the
side of the timer as shown.
• Clears elapsed time value and starts time
ON
delay at power ON. Power supply OFF

• After timer completion, stops at the display of ON


T t1 t2 t1+t2=T

Power on delay (1) the set value (addition), or stops at “0” (sub- Output OFF

traction).
A • Ignores start input.
Reset
ON
OFF

• Stops delay time operation at stop ON. Stop


ON
OFF
Restarts delay time operation at stop OFF.

• Set the operation mode 1 2 3


section of the DIP switches
OFF OFF OFF
(no.’s 1, 2, and 3) on the
side of the timer as shown.
• Elapsed time value does not clear at power
ON
ON. (power outage countermeasure func- Power supply OFF

tion) ON
T t1 t2 t1+t2=T

Power on delay (2) • The output remains ON even after the power Output OFF

is cut and restarted.


A2 • After timer completion, stops at the display of
Reset
ON
OFF

the set value (addition), or stops at “0” (sub- Stop


ON
OFF
traction).
• Ignores start input.
• Stops delay time operation at stop ON.
Restarts delay time operation at stop OFF.

• Set the operation mode 1 2 3


section of the DIP switches
ON OFF OFF
(no.’s 1, 2, and 3) on the
side of the timer as shown.
• Clears elapsed time value at power ON. Power supply
ON
OFF
• Time delay starts at start ON and elapsed T t1 t2 t1+t2=T
ON
time value or output resets at start OFF. Output OFF

Signal on delay • Instantaneous time delay start at reset OFF ON


and power ON while start is ON. Reset OFF

B • Stops delay time operation at stop ON. ON


Stop OFF
Restarts delay time operation at stop OFF.
ON
• In order to have the time delay start at power Start OFF

ON or reset at power OFF, short out the start


input beforehand.

• Set the operation mode 1 2 3


section of the DIP switches
OFF ON OFF
(no.’s 1, 2, and 3) on the ON
side of the timer as shown. Power supply OFF
T>ta+tb T>t
• Clears elapsed time value at power ON. Output
ON
OFF

Signal off delay • Output control ON at start ON and time delay T ta tb t


ON
start at start OFF. Reset OFF

C • Elapsed time value clears when start goes ON Stop


ON
OFF
again during time delay. ON
Start
• Stops delay time operation at stop ON. OFF

Restarts delay time operation at stop OFF.

Notes: 1) Each signal input (start, reset, stop, and lock) is applied by shorting their input terminal to the common terminal (terminal Q for the 8-pin type, terminal E for
the 11-pin type, and terminal 6 for the screw terminal type).
2) The 8-pin type does not have a stop input or lock input.
LT4H/-L
T: Set time t1, t2, t3, ta<T

Operation type Explanation Time chart


• Set the operation mode 1 2 3
section of the DIP switches
ON ON OFF
(no.’s 1, 2, and 3) on the
side of the timer as shown.
• Clears elapsed time value at power ON. Power supply
ON
OFF
• Time delay starts and output control ON at T>ta T=t1+t2
ON
start ON. Output OFF
T ta T t1 t2 t
Pulse One-shot • Turns output control OFF and clears elapsed Reset
ON
OFF
time value at time-up.
D • Ignores start input during time delay.
Stop
ON
OFF

ON
• Stops delay time operation at stop ON. Start OFF

Restarts delay time operation at stop OFF.


• In order to have the time delay start at power
ON or reset at power OFF, short out the start
input beforehand.

• Set the operation mode 1 2 3


section of the DIP switches
OFF OFF ON
(no.’s 1, 2, and 3) on the
side of the timer as shown.
• Clears elapsed time value at power ON. ON
Power supply OFF
• Time delay starts at start ON. T=t1+t2
• Ignores start input during time delay. Output
ON
OFF

Pulse On delay • Stops delay time operation at stop ON. ON


T t1 t2 T T
Reset OFF
Restarts delay time operation at stop OFF.
E • In order to have the time delay start at power Stop
ON
OFF

ON or reset at power OFF, short out the start Start


ON
OFF
input beforehand.

• Set the operation mode 1 2 3


section of the DIP switches
ON OFF ON
(no.’s 1, 2, and 3) on the
side of the timer as shown.
• Clears elapsed time value at power ON. ON
Power supply OFF
• Time delay starts at start ON. T=t1+t2 T>ta T=t1+t2
• Ignores start input during time delay. Output
ON
OFF

Signal Flicker • Output control reverses, elapsed time value ON


T T t1 t2 ta T t1 t2
Reset OFF
clears, and timer delay starts at timer comple-
F tion. Stop
ON
OFF

• Stops delay time operation at stop ON. Start


ON
OFF
Restarts delay time operation at stop OFF.
• In order to have the time delay start at power
ON or reset at power OFF, short out the start
input beforehand.

• Set the operation mode 1 2 3


section of the DIP switches
OFF ON ON
(no.’s 1, 2, and 3) on the ON
side of the timer as shown. Power supply OFF

T=t1+t2+t3 T>ta
• Elapsed time value does not clear at power Output
ON
OFF

Totalizing On delay ON. (power outage countermeasure function) T t1 t2 t3 ta


ON
• The output remains ON even after the power Reset OFF

G is off and restarted. Stop


ON
OFF
• Stops delay time operation at stop ON. ON
Start
Restarts delay time operation at stop OFF. OFF

Notes: 1) Each signal input (start, reset, stop, and lock) is applied by shorting their input terminal to the common terminal (terminal Q for the 8-pin type, terminal E for
the 11-pin type, and terminal 6 for the screw terminal type).
2) The 8-pin type does not have a stop input or lock input.