STRUCTURAL ENGINEERING LABORATORY DEPARTMENT OF CIVIL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI -600 036, INDIA 1: [email protected] Dr. G. APPA RAO, Ph.D. (IISc) PROFESSOR To, Dt: 05.01.2022. M/s The National High Speed Rail Corporation Limited, 1001-1006, 10" Floor, Swastik Universal, Opp.Central Shopping Mall, Piplod, Rundh, Surat Magdalla Road, Surat - 395 007. Sir, Sub: “Relaxation Test for 15.2mm High Tension Strands” - Report - Reg. Ref: Your Mail Dated: 14.05.2021 1 Type of test 100 hrs 2 Type of material 152 mm 3 Material Make TATA 4 Heat No & Coil No M8007 & Y2245B 5 Applied load 182490 N (70% of breaking load As per IS 14268-2017) 6 Loss in load after 100 hrs 2207 N 7% of loss in load after 100 hrs 1.209 % 8 Remark Test conducted as per IS 14268-2017 and the specification are satisfied © : #91-44-2257 4279 (0) 2257 6279 (R) fal: +91-44- 2257 5286/2257 4252 fd: + 91-94440 47421 ofloss 1.40 1.20 0.80 0.40 0.20 0.00 on Fig. 1. 100 hrs relaxation test data, 100 Time in hours 1000 STRUCTURAL ENGINEERING LABORATORY DEPARTMENT OF CIVIL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI - 600036, INDIA [): [email protected] Dr. G. APPA RAO, Ph.D. (IISc) PROFESSOR To, Dt: 05.01.2022. M/s The National High Speed Rail Corporation Limited, 1001-1006, 10" Floor, Swastik Universal, Opp.Central Shopping Mall, Piplod, Rundh, Surat Magdalla Road, Surat - 395 007. Sir, Sub: “Relaxation Test for 5.2mm High Tension Strands” - Report - Reg. Ref: Your Mail Dated: 14.05.2021 1 Type of test 1000 hrs 2 Type of material 15.2 mm 3 Material Make TATA 4 Heat No & Coil No 80077 & Y2245B Applied load 182490 N (70% of breaking load ‘As per IS 14268-2017) 6 Loss in load after 1000 hrs 4179 N 7% of loss in load after 1000 hrs 2.29 % 8 Remark Test conducted as per IS 14268-2017 and the specification are satisfied echnology Madras 600 036, india © : 491-44-2257 4279 (0) 2257 6279 (R) If: +91-44-2257 5286 / 2257 4252 fa): + 91-94440 47421 2.50 $225 ® 2.00 175 150 125 1.00 075 0.50 025 0.00 ‘Time in hours Fig. 1. 1000 hrs relaxation test data, Dr. G. APPA RAO Professor egerment ot ew ENE an ite of Tecnology Madras ‘Cheanai ~690 035, India

You might also like