1. Product Introduction
2 / 11
HIWEIGH TECHNOLOGIES LIMITED
WIM (Weigh-In-Motion) is the top technology in weighing field. We
have long been engaged in research, development and production of the
axle load WIM system. We are one of the few firms who have the
intellectual property right of their own. This system is more reliable with
high accuracy and can be used in portable vehicle scales and other axle
load WIM systems.
Please read and understand this manual thoroughly before using the
system and in case of any problem, please contact our local distributor for
technical support.
2. Features
3 / 11
HIWEIGH TECHNOLOGIES LIMITED
4. Operation
A. Start System
4 / 11
HIWEIGH TECHNOLOGIES LIMITED
LOAD CELL CONNECTION:
Pin1 - S+ Pin2 – S-
Pin3 – E+ Pin4 – E-
After the system is ready, the system will load the main menu.
B. Function Explain:
If you are using In-Motion Weighing System, above main menu would be
displayed.
"Weigh in Motion": In this function, there are two weighing modes: Manual and
Auto. This can be selected in "Settings" menu.
5 / 11
HIWEIGH TECHNOLOGIES LIMITED
If you are using Static Weighing System, above main menu would be displayed.
"Static Weighing": It is to weight the axles of the truck in static which means
the truck has to stop on the scale every time when an axle is on the scale. In this
way, it is used as normal axle scale and there must be at least 2 operators. One of
them would guide the truck driver to stop on the scale and at the meantime the
other one would press "Weigh" button on the screen to record the weight. Please
press "Weigh" button only when the system locks the weight.
"Records": This is the data records of all weighing data including valid and
invalid. Please note this data is stored in the system by CVS file. Operator can
export it to computer and access it through a USB disk. Also the records could be
able to review, re-print and check.
"Settings": It is the core of the system to setup. Please do NEVER change
any settings unless your local distributor authorized.
"Data Monitor": It is to monitor the data and this function is only for
engineer to check the status of the whole system and calibration in case of
necessary.
"Turn Off": This is to switch off the system. But please note even the system
is switched off; the power supply unit is still working before operator turn off the
physical button on the indicator.
6 / 11
HIWEIGH TECHNOLOGIES LIMITED
a) Weigh In Motion:
Previous Scale Current Scale Previous Scale Total Weight Current Scale
Please note:
A Weight A Weight B Weight of the truck B Weight
In Manual weighing mode, the "Axle Type" inputting is required and it is valid.
Manual Weighing mode means the operator must input the axle type of the truck
before weighing. After that the truck goes pass the scale by as low as 5km/h
speed. After the whole truck passed the printer would automatically print the
weighing report.
Auto Weighing mode means unattended weighing. The operator does NOT do
anything on indicator. The sensor in the scale would automatically detect the
axles and make mathematics calculation. After the whole truck passed, please
leave 20 seconds for the system to make calculation and printing. During this
period, please make sure there will be no more truck goes onto the scale and there
is nothing on the scale because the system would also set the Zero Point during
this period. If anything is on the scale, it would seriously damage the accuracy
and system calculation.
7 / 11
HIWEIGH TECHNOLOGIES LIMITED
"Truck" filed is for the operator to input the Truck License Plate number. Please enter the
Truck License Plate Number from the small key pad. After it is entered, please press "Enter"
button for the system to record.
"Speed" would be automatically detected by the sensor. If the speed is over 6km/h, the
data could be invalid or having more than 3% difference than actual weight.
"Start" is to start weighing working and it can be pressed only when every filed is filled.
"Print" is to print the current weight. Please note the printer will print if in settings
“Printing Mode” is set to “Auto mode”. Otherwise it will not print until “Print” button is
pressed. “"Print" button is only valid when data is recorded.
"Zero" is when all weighing and printing work has been done while there is any base
number still on the screen, press this button to set the new "Zero" point.
"Back" is to back to the main menu.
8 / 11
HIWEIGH TECHNOLOGIES LIMITED
b) Static Weighing:
"Truck" filed is for the operator to input the Truck License Plate number. Please enter the
Truck License Plate Number from the small key pad. After it is entered, please press "Enter"
button for the system to record.
"Nos" filed is the axles which has been weight and recorded. It is auto added by system.
"Weighing“ button has to be pressed every time when the truck stops an axle on the scale
and the weight is locked.
"Print" button will be valid only when “End” button is pressed and the whole
information is recorded.
"End" button will be pressed ONLY when the whole truck passed and all axle weight is
recorded. After it is pressed, "Print" button will be valid and the records will be saved into the
system database. If it is pressed before the whole truck passed, the rear axle weight will not be
recorded for present truck.
"Zero" is when all weighing and printing work has been done while there is any base
number still on the screen, press this button to set the new "Zero" point.
"Back" is to back to the main menu.
c) Records:
9 / 11
HIWEIGH TECHNOLOGIES LIMITED
The records could be inquired by date and Truck license number.
Operator also can export the records to USB device and access the data from PC.
10 / 11
HIWEIGH TECHNOLOGIES LIMITED
5. User Attention:
The user manual ends here. If you have any question, please contact your
local distributor to get help. Thank you to choose HIWEIGH Scale.