D Series
D Series
ur s
Product Data Sheet
sl id
s
PS-00388
Model D and DT
d iqu
January 2000
an s l
Mass Flow
s, re
se su
High-temperature sensors
Three models of DT sensors measure process fluids
at high temperatures up to 800°F (426°C), without
the need for purge connections.
High-flow sensor
The D600, our largest sensor, is able to measure
flows up to 25,000 lb/min (680,400 kg/h), making it
ideal for ship loading and unloading, pipeline
transfers, platform production, and LACT
applications.
Housing options
Most Model D sensors are available with optional
purge connections, and some feature purge
connections and/or rupture disks.
re
atu
ed
re
ble isk
CN end
de per
ila ing
su
ava ure d
mo -pres
ava e fitt
mo -tem
mo dard
for mm
ble
G
l
ila
de
de
co
pt
rg
h
h
n
Hig
Hig
Sta
Ru
Re
Pu
Typical line size
D600 3 to 6 inch ‹
(75 to 150 mm)
High-pressure models
High-temperature models
To determine accuracy, turndown, and pressure drop using your process variables, use
the Micro Motion flowmeter selection guide. Download a free copy from our Web site at
www.micromotion.com, or contact your local Micro Motion representative.
Sample data
2.5 18.0 (1.2)
100:1 1:1
2.0 20:1
10:1 15.0 (1.0)
1.5
15
12.0 (0.8)
D
Accuracy, %
0.5 5
D2
0 9 .0 (0.6)
–0.5
00
D6 6 .0 (0.4)
–1.0
–1.5
3 .0 (0.2)
–2.0
–2.5 0
0 10 20 30 40 50 60 70 80 90 100
Accuracy Accuracy, ±%
100:1 20:1 10:1 1:1
turndown turndown turndown turndown
D25 2.15 0.55 0.35 0.17
D40 2.15 0.55 0.35 0.17
D65 2.15 0.55 0.35 0.17
D100 2.65 0.65 0.40 0.18
D150 2.29 0.58 0.36 0.17
D300 1.15 0.35 0.25 0.16
D600 1.15 0.35 0.25 0.16
To determine accuracy, turndown, and pressure drop using your process variables, use
the Micro Motion flowmeter selection guide. Download a free copy from our Web site at
www.micromotion.com, or contact your local Micro Motion representative.
0.5
0 9 .0 (0.6)
–0.5
6 .0 (0.4)
–1.0
–1.5
3 .0 (0.2)
–2.0
–2.5 0
0 10 20 30 40 50 60 70 80 90 100
Accuracy Accuracy, ±%
100:1 20:1 10:1 1:1
turndown turndown turndown turndown
DH38 10.15 2.15 1.15 0.25
To determine accuracy, turndown, and pressure drop using your process variables, use
the Micro Motion flowmeter selection guide. Download a free copy from our Web site at
www.micromotion.com, or contact your local Micro Motion representative.
00
D
12.0 (0.8)
65
DT
Accuracy, %
0.5
0 9 .0 (0.6)
–0.5
6 .0 (0.4)
–1.0
DT 150
–1.5
3 .0 (0.2)
–2.0
–2.5 0
0 10 20 30 40 50 60 70 80 90 100
Accuracy Accuracy, ±%
100:1 20:1 10:1 1:1
turndown turndown turndown turndown
DT65 2.15 0.55 0.35 0.17
DT100 2.15 0.55 0.35 0.17
DT150 2.15 0.55 0.35 0.17
Temperature effect Process temperature effect on span is the worst-case output error due to process fluid
on span temperature change away from the calibration temperature. Only Model DT sensors are affected.
Effect on flow outputs Effect on density outputs
% of rate per °C g/cc per °C kg/m3 per °C
DT sensors ±0.005 ±0.00003 ±0.03
Temperature offset The long-term temperature offset causes a shift in sensor calibration, which is attributed to a
long-term change in the elasticity modulus as a result of sensor operation at elevated
temperatures. The calibration shift is always negative and causes the flowmeter to read lower
than the actual flow rate. The effects of this shift can be minimized with periodic calibration. Only
Model DT sensors are affected.
Offset
DT sensors Above 600°F (315°C), –0.092% of rate per °C in addition to process
temperature effect (above)
Pressure effect Pressure effect is defined as the change in sensor flow sensitivity due to process pressure
change away from the calibration pressure. Pressure effect can be corrected. Only the sensors
listed below are affected.
Effect on flow accuracy Effect on density accuracy
% of rate % of rate g/cc kg/m3
per psi per bar per psi per bar
D300 –0.009 –0.131 –0.00001 –0.0175
D300 Tefzel (2) –0.009 –0.131 –0.00001 –0.0175
D600 –0.005 –0.073 –0.0000031 –0.045
(1)
Nominal flow rate is the upper limit of the nominal flow range.
(2)
Flow tubes are 316L stainless steel with Tefzel lining.
Sensor weight
Approximate weight of sensors with noted process fittings.
with process connection type lb kg
D25 1/2" ANSI 150 lb WNRF flanges 8 3.6
D40 1/2" ANSI 150 lb WNRF flanges 8 3.6
D65 1/2" ANSI 150 lb WNRF flanges 17.3 7.8
D100 1" ANSI 150 lb WNRF flanges 40 18.2
D150 1 1/2" ANSI 150 lb WNRF flanges 46 20.9
D300 3" ANSI 150 lb WNRF flanges 113 60.4
D600 6" ANSI 150 lb WNRF flanges 1400 635
DH38 3/8" NPT union fittings 8 3.6
DH100 1 1/2" high-pressure, clamp-type flanges 80 36.4
DH150 1 1/2" high-pressure, clamp-type flanges 80 36.4
DH300 4" high-pressure, clamp-type flanges 218 99.1
DT65 1/2" ANSI 300 lb WNRF flanges 52 24
DT100 1" ANSI 300 lb WNRF flanges 105 48
DT150 1 1/2" ANSI 300 lb WNRF flanges 155 70
(1)
General corrosion guides do not account for cyclical stress, and therefore should not be relied upon when choosing a wetted
material for your Micro Motion sensor. Please refer to Micro Motion’s corrosion guide for material compatibility information.
4 1/8 9 25/32
FLOW (248)
(105)
Dim. B
4
3/4-14
2 5/16 (102)
NPT F
(59)
3 15/16 6 13/16
(100) (173)
Dim. A
face-to-face
Union fitting
detail
6 13/16
(173)
Dim. A
face-to-face
4 1/8 9 25/32
FLOW (248)
(105)
3/4-14 4
2 5/16 (102)
NPT F
(59)
3 15/16 6 13/16
(100) (173)
Dim. A
face-to-face
Dim. B
4
(102)
1 7/16
3/4-14 (37)
NPT F 3 15/16 12 1/2 2 5/16
1/2" female NPT
(100) conduit bushing (316) (59)
Dim. A
face-to-face
Union fitting
detail
12 1/2
(316)
Dim. A
face-to-face
Dim. A Dim. B
Fitting Face-to-face Outside diameter
Fittings(1) code inches (mm) inches (mm)
1/2-inch ANSI 150 lb weld neck raised face flange 113 16 3/16 (411) 3 1/2 (89)
1/2-inch ANSI 300 lb weld neck raised face flange 114 16 9/16 (421) 3 3/4 (95)
1/2-inch ANSI 600 lb weld neck raised face flange 115 17 1/16 (433) 3 3/4 (95)
1/2-inch ANSI 900 lb weld neck raised face flange 237 17 11/16 (449) 4 3/4 (121)
1-inch ANSI 150 lb weld neck raised face flange 219 17 1/8 (435) 4 1/4 (108)
1-inch ANSI 300 lb weld neck raised face flange 241 17 5/8 (448) 4 7/8 (124)
1-inch ANSI 600 lb weld neck raised face flange 918 18 (457) 4 7/8 (124)
1-inch ANSI 900/1500 lb weld neck raised face flange 919 18 7/8 (479) 5 7/8 (149)
3/4-inch NPT female union fitting 239 14 5/16 (364) 1 3/16 (30)
1-inch sanitary fitting 238 16 (406) 2 (51)
15 mm DIN PN40 weld neck, DIN 2635, type C face 116 15 7/16 (392) 3 3/4 (95)
15 mm JIS 10K weld neck raised face flange 216 15 3/16 (386) 3 3/4 (95)
15 mm JIS 20K weld neck raised face flange 118 15 3/8 (391) 3 3/4 (95)
(1)
Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.
1 7/16
(37) 2X 1/2-14 NPT
female purge
fitting (optional) G F E
2X 1/2-14 NPT
male hex plug
FLOW
2
(51) B
1 7/16 H
3/4-14 (37)
NPT F
3 15/16 J 2 5/16
(100) (59)
A
Dimensions(1)
Standard-pressure sensors C D E F G H J K L
D100 inches 12 1/4 6 1/8 24 3/4 23 5/16 21 9/32 4 12 7/8 4 2
(mm) (311) (156) (629) (592) (541) (102) (327) (102) (51)
D150 inches 12 1/4 6 1/8 24 3/4 23 5/16 21 9/32 4 12 7/8 4 2
(mm) (311) (156) (629) (592) (541) (102) (327) (102) (51)
D300 inches 17 8 1/2 39 7/16 36 15/16 33 27/32 4 1/2 17 7/8 7 1/4 3 5/8
(mm) (432) (216) (1002) (938) (860) (114) (454) (184) (92)
High-pressure sensors
DH100 inches 12 1/4 6 1/8 24 27/32 23 13/32 21 3/8 4 12 7/8 4 2
(mm) (311) (156) (631) (595) (543) (102) (327) (102) (51)
DH150 inches 12 3/4 6 3/8 28 11/32 26 29/32 24 29/32 4 12 7/8 4 1/2 2 1/4
(mm) (324) (162) (720) (683) (633) (102) (327) (114) (57)
(1)
For dimensions A and B, see process fittings tables, pages 21–22.
1 7/16
(37)
39 7/16
(1002)
2X 1/2-14 NPT
female purge 36 15/16
fitting (optional) (938)
33 27/32
2X 1/2-14 NPT (860)
male hex plug
FLOW
2
(51) Dim. B
3/4-14 1 7/16
NPT F (37)
8 3/4 17 7/8 4 1/2
3 15/16 (221) (454) (114)
(100) Dim. A 2 5/16
face-to-face (59)
Dim. A Dim. B
Fitting Face-to-face Outside diameter
Fittings for standard-pressure, stainless steel sensors(1) code inches (mm) inches (mm)
3-inch ANSI 150 lb weld neck raised face flange 155 23 1/4 (591) 7 1/2 (191)
3-inch ANSI 300 lb weld neck raised face flange 156 24 (610) 8 1/4 (210)
3-inch ANSI 600 lb weld neck raised face flange(2) 157 24 3/4 (629) 8 1/4 (210)
3-inch sanitary fitting(2) 161 21 3/8 (543) 3 19/32 (91)
80 mm DIN PN40, DIN 2635, type C face 158 22 5/16 (567) 7 7/8 (200)
80 mm JIS 10K weld neck raised face flange(2) 159 21 11/16 (551) 7 9/32 (185)
80 mm JIS 20K weld neck raised face flange(2) 160 22 5/16 (567) 7 7/8 (200)
Snub-mount connector
16 1/2 33 3/4
(419) (858) 2 9/16
(65)
68 11/16
(1745)
75 7/16
(1916)
Dim. B
12 1/2
(318) 36 1/2-14 NPT F
(914) conduit opening
Dim. A
face-to-face
Dim. A Dim. B
Fitting Face-to-face Outside diameter
Fittings(1) code inches (mm) inches (mm)
6-inch ANSI 150 lb weld neck raised face flange 165 43 (1092) 11 (279)
6-inch ANSI 300 lb weld neck raised face flange 166 43 3/4 (1111) 12 1/2 (317)
150 mm DIN PN40 weld neck, DIN 2635, type C face 167 42 1/16 (1068) 11 55/64 (301)
150 mm JIS 10K weld neck raised face flange 168 40 15/32 (1028) 11 1/16 (281)
150 mm JIS 20K weld neck raised face flange 169 42 1/16 (1068) 12 1/16 (306)
(1)
Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.
H
C
G 4 1/2
(114)
FLOW
Grounding
bolt
D A
Dimensions
High-temperature sensors C D E F G H
DT65 inches 25 1/2 9 5 1/2 15 1/2 20 16
(mm) (648) (229) (140) (394) (508) (406)
DT100 inches 29 1/2 10 6 1/2 17 1/2 24 18
(mm) (749) (254) (165) (444) (610) (457)
DT150 inches 35 1/2 11 1/2 8 20 1/2 30 21
(mm) (902) (292) (203) (521) (762) (533)
Dim. A Dim. B
Fitting Face-to-face Outside diameter
Fittings for DT65 sensors(1) code inches (mm) inches (mm)
1/2-inch ANSI 300 lb weld neck raised face flange 114 23 7/8 (606) 3 3/4 (95)
1/2-inch ANSI 600 lb weld neck raised face flange 115 23 7/8 (606) 3 3/4 (95)
15 mm DIN PN40 weld neck, DIN 2635, type C face 116 22 3/4 (578) 3 3/4 (95)
15 mm JIS 20K weld neck raised face flange 118 22 3/4 (578) 3 3/4 (95)
Code Approvals
M Micro Motion standard — no approvals
U UL intrinsically safe — U.S.A. approvals agency
C CSA — Canadian approvals agency, not available with DS600
B CENELEC — European approvals agency
S SAA — Australian approvals agency, not available with DS600
Example*
DS025 S 113 S U
*Example: DS025 S 113 S U = Model D25 1/4-inch standard-pressure sensor, 316L stainless steel; 1/2-inch ANSI 150 lb weld
neck raised face flanges; standard pressure containment; UL approved for intrinsically safe installations
Code Approvals
M Micro Motion standard — no approvals
U UL intrinsically safe — U.S.A. approvals agency
C CSA — Canadian approvals agency
B CENELEC — European approvals agency
S SAA — Australian approvals agency
Example*
DH038 S 119 S U
*Example: DH038 S 119 S U = Model DH38 3/8-inch high-pressure sensor, 316L stainless steel; 3/8-inch NPT female union
fittings; standard-pressure case; UL approved for intrinsically safe installations
Code Approvals
M Micro Motion standard — no approvals
U UL intrinsically safe — U.S.A. approvals agency
C CSA — Canadian approvals agency
B CENELEC — European approvals agency
Example*
DT100 H 129 G U
*Example: DT100 H 129 G U = Model DT100 1-inch, standard-pressure, high-temperature sensor; Hastelloy ® C-22 nickel alloy;
1-inch ANSI 300 lb weld neck raised face flanges; standard high-temperature case; UL approved for intrinsically safe
installations