rie ,

ur s
Product Data Sheet

sl id
s
PS-00388
Model D and DT

d iqu
January 2000

an s l
Mass Flow
s, re
se su

and Density Sensors


ga ea
M
Model D and DT sensors
Micro Motion® Model D sensors set the standard for Wetted-part materials for your fluid
Coriolis flowmeters nearly a quarter century ago. All Model D and DT sensors come standard with
Today, they continue to provide the same outstanding 316L stainless steel wetted parts. Most models are
measurement performance that made them so also available in nickel alloy, and three models
popular. feature stainless steel flow tubes that are lined with a
Tefzel® coating.
Working with any of our Coriolis transmitters,
Model D and DT sensors provide flow measurement System Integration
for liquids, gases and slurries — simply and directly. Micro Motion offers a variety of microprocessor-
Multivariable capability provides mass flow, volume based transmitters. Depending on the transmitter
flow, density, and temperature measurement — all in model, features include milliampere and
real time, without the need for additional equipment. frequency/pulse outputs, transmitter and process
control functions in a single device, and API outputs
A wide variety of models includes standard process for crude oil and other hydrocarbon fluids.
connections for virtually any fluid process. Select
from models with features that include: Other options include transmitters that can be
installed in instrument racks or panels, or housed in
Sizes for every need NEMA-compliant or explosion-proof enclosures.
Model D sensors are available in standard models Sensors and explosion-proof transmitters can be
ranging in size from 1/8- to 6-inch (3 to 150 mm). installed in the same hazardous area.

High-pressure sensors Micro Motion is known worldwide for increasing plant


Several sensors are available in high-pressure efficiency, production, and profitability. More than
models, for pressure flows up to 5600 psi (386 bar). 250,000 Micro Motion meters are installed and
Two of these, the DH25 and DH38, are designed for working in processes just like yours. Contact us, and
measuring compressed natural gas (CNG) for legal learn more about Model D and DT sensors.
trade.

High-temperature sensors
Three models of DT sensors measure process fluids
at high temperatures up to 800°F (426°C), without
the need for purge connections.

High-flow sensor
The D600, our largest sensor, is able to measure
flows up to 25,000 lb/min (680,400 kg/h), making it
ideal for ship loading and unloading, pipeline
transfers, platform production, and LACT
applications.

Housing options
Most Model D sensors are available with optional
purge connections, and some feature purge
connections and/or rupture disks.

2 Micro Motion D and DT Sensors


Model D and DT features comparison

re
atu

ed
re

ble isk
CN end
de per

ila ing
su

ava ure d
mo -pres

ava e fitt
mo -tem
mo dard

for mm

ble
G
l

ila
de

de

co

pt
rg
h

h
n

Hig

Hig
Sta

Ru
Re

Pu
Typical line size

D25 1/8 to 1/2 inch ‹ ‹ ‹


(3 to 13 mm)

D40 1/4 to 1/2 inch ‹ ‹ ‹


(6 to 13 mm)

D65 1/4 to 1/2 inch ‹ ‹ ‹


(6 to 13 mm)

D100 1/2 to 1 inch ‹ ‹ ‹


(13 to 25 mm)

D150 1 to 1-1/2 inch ‹ ‹ ‹


(25 to 38 mm)

D300 1-1/2 to 3 inch ‹ ‹ ‹


(38 to 75 mm)

D600 3 to 6 inch ‹
(75 to 150 mm)

High-pressure models

DH25 1/8 to 1/2 inch ‹ ‹ ‹ ‹


(3 to 13 mm)

DH38 1/8 to 1/2 inch ‹ ‹ ‹ ‹


(3 to 6 mm)

DH100 1/2 to 1 inch ‹


(13 to 25 mm)

DH150 1 to 1-1/2 inch ‹


(25 to 38 mm)

DH300 1-1/2 to 3 inch ‹


(38 to 75 mm)

High-temperature models

DT65 1/4 to 1/2 inch ‹


(6 to 13 mm)

DT100 1/2 to 1 inch ‹


(13 to 25 mm)

DT150 1 to 1-1/2 inch ‹


(25 to 38 mm)

Micro Motion D and DT Sensors 3


Performance specifications
Flow specifications — standard sensors
Nominal flow range(1) lb/min kg/h
D25 0 to 25 0 to 680
D40 0 to 45 0 to 1225
D65 0 to 150 0 to 4080
D100 0 to 400 0 to 10,890
D150 0 to 1400 0 to 38,100
D300 0 to 7000 0 to 190,500
D600 0 to 25,000 0 to 680,400
Maximum flow rate lb/min kg/h
D25 25 680
D40 45 1225
D65 300 8160
D100 800 21,780
D150 2800 76,200
D300 7000 190,500
D600 25,000 680,400
Accuracy (2) liquid ±0.15% ± [(zero stability / flow rate) x 100]% of rate
gas — except D25, D600 (3) ±0.65% ± [(zero stability / flow rate) x 100]% of rate
gas — D25 ±0.50% ± [(zero stability / flow rate) x 100]% of rate
Repeatability (2) liquid ±0.05% ± [½(zero stability / flow rate) x 100]% of rate
gas — except D25, D600 (3) ±0.30% ± [(zero stability / flow rate) x 100]% of rate
gas — D25 ±0.25% ± [½(zero stability / flow rate) x 100]% of rate
Zero stability lb/min kg/h
D25 0.005 0.14
D40 0.009 0.24
D65 0.03 0.84
D100 0.10 3.0
D150 0.30 9.0
D300 0.70 19.2
D600 2.5 66.0
(1)
Micro Motion has adopted the terminology "nominal flow range." The upper limit of this range is the flow rate at which water at
reference conditions causes approximately 15 psid (1 bar) of pressure drop for D and DT sensors.
(2)
Flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications for liquids are based on
reference conditions of water at 68 to 77°F (20 to 25°C) and 15 to 30 psig (1 to 2 bar), unless otherwise noted.
(3)
Model D600 not rated for gas applications.

4 Micro Motion D and DT Sensors


Performance specifications continued
Flow specifications — high-pressure sensors
Nominal flow range(1) lb/min kg/h
DH25 0 to 25 0 to 680
DH38 0 to 25 0 to 680
DH100 0 to 400 0 to 10,890
DH150 0 to 1400 0 to 38,100
DH300 0 to 7000 0 to 190,500
Maximum flow rate lb/min kg/h
DH25 25 680
DH38 50 1360
DH100 800 21,780
DH150 2800 76,200
DH300 7000 190,500
Accuracy(2) liquid ±0.15% ± [(zero stability / flow rate) x 100]% of rate
gas — except DH25, DH38 ±0.65% ± [(zero stability / flow rate) x 100]% of rate
gas — DH25, DH38 ±0.50% ± [(zero stability / flow rate) x 100]% of rate
Repeatability(2) liquid ±0.05% ± [½(zero stability / flow rate) x 100]% of rate
gas — except DH25, DH38 ±0.30% ± [(zero stability / flow rate) x 100]% of rate
gas — DH25, DH38 ±0.25% ± [½(zero stability / flow rate) x 100]% of rate
Zero stability lb/min kg/h
DH25 0.006 0.18
DH38 0.025 0.68
DH100 0.30 9.0
DH150 1.2 32.6
DH300 4.0 108.0

Flow specifications — compressed natural gas for legal trade


Maximum flow rate(3) lb/min kg/h
DH25 25 680
DH38 50 1360
Minimum flow rate lb/min kg/h
DH25 1.25 34
DH38 2.5 68
Minimum measured lb kg
quantity DH25 1.25 0.56
DH38 2.5 1.13
Delivery accuracy % of batch
DH25 0.5
DH38 0.5
(1)
Micro Motion has adopted the terminology "nominal flow range." The upper limit of this range is the flow rate at which water at
reference conditions causes approximately 15 psid (1 bar) of pressure drop for D and DT sensors.
(2)
Flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications for liquids are based on
reference conditions of water at 68 to 77°F (20 to 25°C) and 15 to 30 psig (1 to 2 bar), unless otherwise noted.
(3)
Maximum velocity when measuring gases: DH25, 100 ft/sec (30 m/sec); DH38, 200 ft/sec (61 m/sec).

Micro Motion D and DT Sensors 5


Performance specifications continued
Flow specifications — high-temperature sensors
Nominal flow range(1) lb/min kg/h
DT65 0 to 150 0 to 4080
DT100 0 to 400 0 to 10,890
DT150 0 to 700 0 to 19,500
Maximum flow rate lb/min kg/h
DT65 300 8160
DT100 800 21,780
DT150 1400 38,100
Accuracy(2) liquid ±0.15% ± [(zero stability / flow rate) x 100]% of rate
gas ±0.65% ± [(zero stability / flow rate) x 100]% of rate
Repeatability(2) liquid ±0.05% ± [½(zero stability / flow rate) x 100]% of rate
gas ±0.30% ± [(zero stability / flow rate) x 100]% of rate
Zero stability lb/min kg/h
DT65 0.03 0.84
DT100 0.08 2.16
DT150 0.14 3.84
(1)
Micro Motion has adopted the terminology "nominal flow range." The upper limit of this range is the flow rate at which water at
reference conditions causes approximately 15 psid (1 bar) of pressure drop for D and DT sensors.
(2)
Flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications for liquids are based on
reference conditions of water at 68 to 77°F (20 to 25°C) and 15 to 30 psig (1 to 2 bar), unless otherwise noted.

6 Micro Motion D and DT Sensors


Performance specifications continued
with Model 3500, 3700,
RFT9739, Model 5300, with IFT9701 with RFT9712
Density specifications — liquid only or RFT9709 transmitter transmitter (1) transmitter (2)
Accuracy g/cc kg/m3 g/cc kg/m3 g/cc kg/m3
D25 ±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0
D40 ±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0
D65 ±0.001 ±1.0 ±0.002 ±2.0 ±0.002 ±2.0
D100 ±0.001 ±1.0 ±0.002 ±2.0 ±0.002 ±2.0
D150 ±0.001 ±1.0 ±0.002 ±2.0 ±0.002 ±2.0
D150 Tefzel (3) ±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0
D300 ±0.0005 ±0.5 ±0.002 ±2.0 ±0.001 ±1.0
D300 Tefzel (3) ±0.001 ±1.0 ±0.002 ±2.0 ±0.002 ±2.0
D600 ±0.0005 ±0.5 n/a n/a ±0.001 ±1.0
DH25 ±0.004 ±4.0 ±0.004 ±4.0 ±0.008 ±8.0
DH38 ±0.004 ±4.0 ±0.004 ±4.0 ±0.008 ±8.0
DH100 ±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0
DH150 ±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0
DH300 ±0.001 ±1.0 ±0.002 ±2.0 ±0.002 ±2.0
DT65 ±0.001 ±1.0 n/a n/a ±0.002 ±2.0
DT100 ±0.001 ±1.0 n/a n/a ±0.002 ±2.0
DT150 ±0.001 ±1.0 n/a n/a ±0.002 ±2.0
Repeatability g/cc kg/m3 g/cc kg/m3 g/cc kg/m3
D25 ±0.001 ±1.0 ±0.001 ±1.0 ±0.002 ±2.0
D40 ±0.001 ±1.0 ±0.001 ±1.0 ±0.002 ±2.0
D65 ±0.0005 ±0.5 ±0.001 ±1.0 ±0.001 ±1.0
D100 ±0.0005 ±0.5 ±0.001 ±1.0 ±0.001 ±1.0
D150 ±0.0005 ±0.5 ±0.001 ±1.0 ±0.001 ±1.0
D150 Tefzel (3) ±0.001 ±1.0 ±0.001 ±1.0 ±0.002 ±2.0
D300 ±0.0002 ±0.2 ±0.001 ±1.0 ±0.0004 ±0.4
D300 Tefzel (3) ±0.0005 ±0.5 ±0.001 ±1.0 ±0.001 ±1.0
D600 ±0.0002 ±0.2 n/a n/a ±0.0004 ±0.4
DH25 ±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0
DH38 ±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0
DH100 ±0.001 ±1.0 ±0.001 ±1.0 ±0.002 ±2.0
DH150 ±0.001 ±1.0 ±0.001 ±1.0 ±0.002 ±2.0
DH300 ±0.0005 ±0.5 ±0.001 ±1.0 ±0.001 ±1.0
DT65 ±0.0005 ±0.5 n/a n/a ±0.001 ±1.0
DT100 ±0.0005 ±0.5 n/a n/a ±0.001 ±1.0
DT150 ±0.0005 ±0.5 n/a n/a ±0.001 ±1.0
Range g/cc kg/m3 g/cc kg/m3 g/cc kg/m3
0 to 5 0 to 5000 0 to 5 0 to 5000 0 to 5 0 to 5000
(1)
Model D600 and DT sensors cannot be used with IFT9701 transmitters.
(2)
When used with an RFT9712 and a DMS, NFC, or NOC, density specifications are the same as when used with a Model 3500.
(3)
Flow tubes are 316L stainless steel with Tefzel lining.

Micro Motion D and DT Sensors 7


Performance specifications continued
Temperature specifications
Accuracy ±1°C ± 0.5% of reading in °C
Repeatability ±0.2°C
Range °F °C
D25 –400 to 350 –240 to 177
D40 –400 to 350 –240 to 177
D65 –400 to 350 –240 to 177
D100 –400 to 400 –240 to 204
D150 –400 to 400 –240 to 204
D150 Tefzel (1) 32 to 250 0 to 121
D300 –400 to 400 –240 to 204
D300 Tefzel (1) 32 to 250 0 to 121
D600 (2) –400 to 400 –240 to 204
DH25 –400 to 350 –240 to 177
DH38 –400 to 350 –240 to 177
DH100 –400 to 400 –240 to 204
DH150 –400 to 400 –240 to 204
DH300 –400 to 400 –240 to 204
DT65 32 to 800 0 to 426
DT100 32 to 800 0 to 426
DT150 32 to 800 0 to 426
(1)
Flow tubes are 316L stainless steel with Tefzel lining.
(2)
Maximum fluid temperature for CENELEC-approved model D600 sensors is 40°C. Ambient temperature limits for booster
amplifier are as follows:
CENELEC-approved model –4 to 104°F (–20 to 40°C)
UL-approved and standard models –22 to 131°F (–30 to 55°C)
If ambient and radiant heat will cause the booster amplifier to exceed these limits, a remotely mounted booster amplifier
assembly is necessary. Consult the factory for remote-mount booster amplifier information.

8 Micro Motion D and DT Sensors


Performance specifications continued
Pressure ratings
Flow tube rating(1) psi bar
D25 1900 131
D40 1250 86
D65 2250 155
D100 2250 155
D150 1500 103
D150 Tefzel (2) 1000 69
D300 740 51
D300 Tefzel (2) 740 51
D600 625 43
DH25 4000 276
DH38 5200 358
DH100 5600 386
DH150 5400 372
DH300 4000 276
DT65 (3) 900 62
DT100 (3) 900 62
DT150 (3) 600 41
Housing All models Housing is not rated for pressure containment.
(1)
Flow tube pressure rating at 77°F (25°C), according to ASME B31.3. For higher operating temperatures, tube pressure needs to
be derated as follows:
Stainless steel sensors 7. 2% derating from 301 to 400°F (149 to 204°C)
Nickel alloy sensors 2% derating from 201 to 300°F (94 to 148°C)
9. 2% derating from 301 to 400°F (149 to 204°C)
(2)
Flow tubes are 316L stainless steel with Tefzel lining.
(3)
Pressure rating at 800°F (426°C).

Micro Motion D and DT Sensors 9


Performance specifications continued
Typical accuracy, turndown, and pressure drop — standard sensors

To determine accuracy, turndown, and pressure drop using your process variables, use
the Micro Motion flowmeter selection guide. Download a free copy from our Web site at
www.micromotion.com, or contact your local Micro Motion representative.

Sample data
2.5 18.0 (1.2)
100:1 1:1
2.0 20:1
10:1 15.0 (1.0)
1.5

Pressure drop, psi (bar)


0
1.0

15
12.0 (0.8)

D
Accuracy, %

0.5 5
D2
0 9 .0 (0.6)

–0.5
00
D6 6 .0 (0.4)
–1.0

–1.5
3 .0 (0.2)
–2.0

–2.5 0
0 10 20 30 40 50 60 70 80 90 100

Nominal flow rate, %

Accuracy Accuracy, ±%
100:1 20:1 10:1 1:1
turndown turndown turndown turndown
D25 2.15 0.55 0.35 0.17
D40 2.15 0.55 0.35 0.17
D65 2.15 0.55 0.35 0.17
D100 2.65 0.65 0.40 0.18
D150 2.29 0.58 0.36 0.17
D300 1.15 0.35 0.25 0.16
D600 1.15 0.35 0.25 0.16

Pressure drop Pressure drop, psi (bar)


100:1 20:1 10:1 1:1
turndown turndown turndown turndown
D25 ~0 0.1 (0.01) 0.2 (0.01) 12.4 (0.86)
D40 ~0 0.1 (0.01) 0.3 (0.02) 15.0 (1.03)
D65 ~0 0.1 (0.01) 0.2 (0.01) 13.6 (0.94)
D100 ~0 0.1 (0.01) 0.2 (0.01) 16.2 (1.12)
D150 ~0 0.1 (0.01) 0.2 (0.01) 15.8 (1.09)
D300 ~0 0.1 (0.01) 0.2 (0.01) 15.1 (1.04)
D600 ~0 0.1 (0.01) 0.1 (0.01) 7.3 (0.50)

10 Micro Motion D and DT Sensors


Performance specifications continued
Typical accuracy, turndown, and pressure drop — DH38 sensor

To determine accuracy, turndown, and pressure drop using your process variables, use
the Micro Motion flowmeter selection guide. Download a free copy from our Web site at
www.micromotion.com, or contact your local Micro Motion representative.

2.5 18.0 (1.2)


100:1 1:1
2.0 20:1
10:1 15.0 (1.0)
1.5

Pressure drop, psi (bar)


1.0
12.0 (0.8)
Accuracy, %

0.5

0 9 .0 (0.6)

–0.5
6 .0 (0.4)
–1.0

–1.5
3 .0 (0.2)
–2.0

–2.5 0
0 10 20 30 40 50 60 70 80 90 100

Nominal flow rate, %

Accuracy Accuracy, ±%
100:1 20:1 10:1 1:1
turndown turndown turndown turndown
DH38 10.15 2.15 1.15 0.25

Pressure drop Pressure drop, psi (bar)


100:1 20:1 10:1 1:1
turndown turndown turndown turndown
DH38 ~0 0.1 (0.01) 0.2 (0.01) 12.0 (0.83)

Micro Motion D and DT Sensors 11


Performance specifications continued
Typical accuracy, turndown, and pressure drop — high-temperature sensors

To determine accuracy, turndown, and pressure drop using your process variables, use
the Micro Motion flowmeter selection guide. Download a free copy from our Web site at
www.micromotion.com, or contact your local Micro Motion representative.

2.5 18.0 (1.2)


100:1 1:1
2.0 20:1
10:1 15.0 (1.0)
1.5

00

Pressure drop, psi (bar)


T1
1.0

D
12.0 (0.8)
65
DT
Accuracy, %

0.5

0 9 .0 (0.6)

–0.5
6 .0 (0.4)
–1.0
DT 150
–1.5
3 .0 (0.2)
–2.0

–2.5 0
0 10 20 30 40 50 60 70 80 90 100

Nominal flow rate, %

Accuracy Accuracy, ±%
100:1 20:1 10:1 1:1
turndown turndown turndown turndown
DT65 2.15 0.55 0.35 0.17
DT100 2.15 0.55 0.35 0.17
DT150 2.15 0.55 0.35 0.17

Pressure drop Pressure drop, psi (bar)


100:1 20:1 10:1 1:1
turndown turndown turndown turndown
DT65 ~0 0.1 (0.01) 0.2 (0.01) 13.2 (0.91)
DT100 ~0 0.1 (0.01) 0.2 (0.01) 16.2 (1.12)
DT150 ~0 0.1 (0.01) 0.1 (0.01) 4.6 (0.32)

12 Micro Motion D and DT Sensors


Functional specifications
Environmental influences
Temperature effect Process temperature effect on zero is defined as the worst-case zero offset due to process fluid
on zero temperature change away from the zeroing temperature.
Effect on zero (1)
% of nominal flow rate per °C
D25 ±0.01
D40 ±0.01
D65 ±0.001
D100 ±0.001
D150 ±0.001
D150 Tefzel (2) ±0.002
D300 ±0.004
D300 Tefzel (2) ±0.004
D600 ±0.004
DH sensors ±0.01
DT sensors ±0.002

Temperature effect Process temperature effect on span is the worst-case output error due to process fluid
on span temperature change away from the calibration temperature. Only Model DT sensors are affected.
Effect on flow outputs Effect on density outputs
% of rate per °C g/cc per °C kg/m3 per °C
DT sensors ±0.005 ±0.00003 ±0.03

Temperature offset The long-term temperature offset causes a shift in sensor calibration, which is attributed to a
long-term change in the elasticity modulus as a result of sensor operation at elevated
temperatures. The calibration shift is always negative and causes the flowmeter to read lower
than the actual flow rate. The effects of this shift can be minimized with periodic calibration. Only
Model DT sensors are affected.
Offset
DT sensors Above 600°F (315°C), –0.092% of rate per °C in addition to process
temperature effect (above)

Pressure effect Pressure effect is defined as the change in sensor flow sensitivity due to process pressure
change away from the calibration pressure. Pressure effect can be corrected. Only the sensors
listed below are affected.
Effect on flow accuracy Effect on density accuracy
% of rate % of rate g/cc kg/m3
per psi per bar per psi per bar
D300 –0.009 –0.131 –0.00001 –0.0175
D300 Tefzel (2) –0.009 –0.131 –0.00001 –0.0175
D600 –0.005 –0.073 –0.0000031 –0.045
(1)
Nominal flow rate is the upper limit of the nominal flow range.
(2)
Flow tubes are 316L stainless steel with Tefzel lining.

Micro Motion D and DT Sensors 13


Functional specifications continued
Hazardous area classifications
Intrinsically safe when properly connected to an approved transmitter. Approval agency on
sensor approval tag must match agency on transmitter approval tag.

UL is a U.S.A. approvals agency, CSA is a Canadian approvals agency, CENELEC is a European


standards organization, and SAA is an Australian approvals agency.
UL D, DH sensors Class I, Div. 1, Groups C and D
Class I, Div. 2, Groups A, B, C, and D
Class II, Div. 1, Groups E, F, and G
DT sensors Class I, Div. 1, Groups C and D
Class I, Div. 2, Groups A, B, C, and D
CSA D, DH sensors Class I, Div. 1, Groups C and D
Class I, Div. 2, Groups A, B, C, and D
Class II, Div. 1, Groups E, F, and G
DT sensors Class I, Div. 1, Groups C and D
Class I, Div. 2, Groups A, B, C, and D
Class II, Div. 1, Groups E, F, and G
CENELEC(1) Maximum fluid temperature, °C
T1 T2 T3 T4 T5 T6
D25, DH25 EEx ib IIC T1...T6 177 177 177 120 85 70
DH38 EEx ib IIC T1...T6 177 177 177 120 85 70
D40 EEx ib IIC T1...T6 204 204 185 120 85 70
D65 EEx ib IIC T1...T6 177 177 177 120 85 70
D100, DH100 EEx ib IIB T1...T6 204 204 185 120 85 70
D150, DH150 EEx ib IIB T1...T6 204 204 185 120 85 70
D300, DH300 EEx ib IIB T1...T6 204 204 162 97 62 47
D600 EEx [ib] de IIB T4 40
DT sensors EEx ib IIB T1...T6 409 259 164 99 64 49
SAA D25, DH25 Ex ib IIB T4
DH38 Ex ib IIB T4
D40 Ex ib IIB T4
D100, DH100 Ex ib IIB T4
D150, DH150 Ex ib IIB T6
D150 Tefzel (2) Ex ib IIB T6
D300, DH300 Ex ib IIB T4
D300 Tefzel (2) Ex ib IIB T4
DT sensors Ex ib IIB T6
(1)
CENELEC "T" rating depends on the maximum temperature of the process fluid flowing through the sensor.
(2)
Flow tubes are 316L stainless steel with Tefzel lining.

14 Micro Motion D and DT Sensors


Physical specifications
Materials of construction
Standard materials of construction are as follows:
SS = 316L stainless steel (SS) flow tubes and flanges, CF-3M SS manifolds
Ni = Hastelloy ® C-22 nickel alloy (Ni) flow tubes and glands with Hastelloy CW-2M Ni manifolds
Ni/SS = Hastelloy C-22 Ni flow tubes with 316L SS manifolds and flanges
Lined = 316L stainless steel flow tubes with Tefzel ® lining
Wetted parts(1) SS Ni Ni/SS Lined
D25 9 9
D40 9 9
D65 9
D100 9 9
D150 9 9 9
D300 9 9 9
D600 9
DH25 9
DH38 9
DH100 9
DH150 9
DH300 9
DT65 9
DT100 9
DT150 9

Housing 304 stainless steel


Junction box Epoxy-coated aluminum

Sensor weight
Approximate weight of sensors with noted process fittings.
with process connection type lb kg
D25 1/2" ANSI 150 lb WNRF flanges 8 3.6
D40 1/2" ANSI 150 lb WNRF flanges 8 3.6
D65 1/2" ANSI 150 lb WNRF flanges 17.3 7.8
D100 1" ANSI 150 lb WNRF flanges 40 18.2
D150 1 1/2" ANSI 150 lb WNRF flanges 46 20.9
D300 3" ANSI 150 lb WNRF flanges 113 60.4
D600 6" ANSI 150 lb WNRF flanges 1400 635
DH38 3/8" NPT union fittings 8 3.6
DH100 1 1/2" high-pressure, clamp-type flanges 80 36.4
DH150 1 1/2" high-pressure, clamp-type flanges 80 36.4
DH300 4" high-pressure, clamp-type flanges 218 99.1
DT65 1/2" ANSI 300 lb WNRF flanges 52 24
DT100 1" ANSI 300 lb WNRF flanges 105 48
DT150 1 1/2" ANSI 300 lb WNRF flanges 155 70
(1)
General corrosion guides do not account for cyclical stress, and therefore should not be relied upon when choosing a wetted
material for your Micro Motion sensor. Please refer to Micro Motion’s corrosion guide for material compatibility information.

Micro Motion D and DT Sensors 15


D25 and D40 dimensions
inches
Dimensions in
(mm)
9
#10-32 UNF for (229)
grounding (green
binding head screw) 2 7/32 8 3/32
(56) 1 3/32 (208)
(28) 4 1/2
3/8
(114)
(10)
2X 1/2-14 NPT
female purge
fitting (optional)
10 19/32
(269)
8 25/32
(223)

4 1/8 9 25/32
FLOW (248)
(105)

Dim. B

4
3/4-14
2 5/16 (102)
NPT F
(59)

3 15/16 6 13/16
(100) (173)

Dim. A
face-to-face

Union fitting
detail

6 13/16
(173)
Dim. A
face-to-face

16 Micro Motion D and DT Sensors


D25 process fittings
Dim. A Dim. B
Fitting Face-to-face Outside diameter
Fittings for standard-pressure, stainless steel sensors(1) code inches (mm) inches (mm)
1/2-inch ANSI 150 lb weld neck raised face flange 113 10 1/4 (260) 3 1/2 (89)
1/2-inch ANSI 300 lb weld neck raised face flange 114 10 5/8 (270) 3 3/4 (95)
1/2-inch ANSI 600 lb weld neck raised face flange 115 11 1/8 (283) 3 3/4 (95)
3/8-inch NPT female union fitting 119 8 1/8 (206) ---
1/2-inch sanitary fitting 121 9 3/4 (248) 1 (25)
15 mm DIN PN40 weld neck, DIN 2635, type C face 116 10 7/16 (265) 3 3/4 (95)
15 mm JIS 10K weld neck raised face flange 216 10 1/4 (260) 3 3/4 (95)
15 mm JIS 20K weld neck raised face flange 118 10 1/4 (260) 3 3/4 (95)

Fittings for standard-pressure, nickel alloy sensors(1)


1/2-inch ANSI 150 lb lap joint flange 124 11 1/4 (286) 3 1/2 (89)
1/2-inch ANSI 300 lb lap joint flange 125 11 1/4 (286) 3 3/4 (95)
1/2-inch ANSI 600 lb lap joint flange 126 11 1/4 (286) 3 3/4 (95)
15 mm DIN PN40 lap joint flange, DIN 2656 217 11 1/4 (286) 3 3/4 (95)
15 mm JIS 10K lap joint flange 117 11 1/4 (286) 3 3/4 (95)

Fittings for high-pressure, stainless steel sensors(1)


1-inch high-pressure clamp-type flange(2) 225 10 1/4 (260) 2 (51)
1/2-inch 900/1500 lb weld neck raised face flange 903 11 31/32 (304) 5 1/4 (133)
1/2-inch 2500 lb weld neck raised face flange 905 12 31/32 (329) 4 1/4 (108)
3/8-inch NPT female union fitting 119 8 1/8 (206) ---

D40 process fittings


Dim. A Dim. B
Fitting Face-to-face Outside diameter
Fittings for standard-pressure, stainless steel sensors(1) code inches (mm) inches (mm)
1/2-inch ANSI 150 lb weld neck raised face flange 113 10 1/4 (260) 3 1/2 (89)
1/2-inch ANSI 300 lb weld neck raised face flange 114 10 5/8 (270) 3 3/4 (95)
1/2-inch ANSI 600 lb weld neck raised face flange 115 11 1/8 (283) 3 3/4 (95)
3/8-inch NPT female union fitting 119 8 1/8 (206) ---
1/2-inch sanitary fitting 121 9 3/4 (248) 1 (25)
15 mm DIN PN40 weld neck, DIN 2635, type C face 116 10 7/16 (265) 3 3/4 (95)
15 mm JIS 10K weld neck raised face flange 216 10 1/4 (260) 3 3/4 (95)
15 mm JIS 20K weld neck raised face flange 118 10 1/4 (260) 3 3/4 (95)

Fittings for standard-pressure, nickel alloy sensors(1)


1/2-inch ANSI 150 lb lap joint flange 124 11 1/4 (286) 3 1/2 (89)
1/2-inch ANSI 300 lb lap joint flange 125 11 1/4 (286) 3 3/4 (95)
1/2-inch ANSI 600 lb lap joint flange 126 11 1/4 (286) 3 3/4 (95)
15 mm DIN PN40 lap joint flange, DIN 2656 217 11 1/4 (286) 3 3/4 (95)
15 mm JIS 10K lap joint flange 117 11 1/4 (286) 3 3/4 (95)
(1)
Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.
(2)
Oteco hub size: 1 OC4. Mating connectors (not included): Grayloc hub size 1 GR4, seal ring size 4; clamp size 1, stainless steel.

Micro Motion D and DT Sensors 17


DH38 dimensions and process fittings
inches
Dimensions in
(mm)
9
#10-32 UNF for (229)
grounding (green 2 7/32
binding head screw) (56) 8 3/32
1 3/32 (206)
(28) 4 1/2
3/8
(114)
(10)
2X 1/2-14 NPT
female purge
fitting (optional)
10 19/32
(269)
8 25/32
(223)

4 1/8 9 25/32
FLOW (248)
(105)

3/4-14 4
2 5/16 (102)
NPT F
(59)

3 15/16 6 13/16
(100) (173)

Dim. A
face-to-face

Fitting Dim. A, Face-to-face


Fittings(1) code inches (mm)
3/8-inch NPT female union fitting 119 8 1/8 (206)
(1)
Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.

18 Micro Motion D and DT Sensors


D65 dimensions and process fittings
inches
Dimensions in
(mm) 3 1/2
(89)
11
#10-32 UNF for 3 (279)
grounding (green (76)
1 1/2 5 1/2 3/8
binding head screw)
1 1/2 (38) (140) (10)
(38)

1 7/16 2X 1/2-14 NPT female 14


(37) purge fitting (optional) (356)
2X 1/2-14 NPT male
hex plug
16 11/16
(424)
1 1/2 FLOW
(38)

Dim. B
4
(102)
1 7/16
3/4-14 (37)
NPT F 3 15/16 12 1/2 2 5/16
1/2" female NPT
(100) conduit bushing (316) (59)
Dim. A
face-to-face

Union fitting
detail

12 1/2
(316)
Dim. A
face-to-face

Dim. A Dim. B
Fitting Face-to-face Outside diameter
Fittings(1) code inches (mm) inches (mm)
1/2-inch ANSI 150 lb weld neck raised face flange 113 16 3/16 (411) 3 1/2 (89)
1/2-inch ANSI 300 lb weld neck raised face flange 114 16 9/16 (421) 3 3/4 (95)
1/2-inch ANSI 600 lb weld neck raised face flange 115 17 1/16 (433) 3 3/4 (95)
1/2-inch ANSI 900 lb weld neck raised face flange 237 17 11/16 (449) 4 3/4 (121)
1-inch ANSI 150 lb weld neck raised face flange 219 17 1/8 (435) 4 1/4 (108)
1-inch ANSI 300 lb weld neck raised face flange 241 17 5/8 (448) 4 7/8 (124)
1-inch ANSI 600 lb weld neck raised face flange 918 18 (457) 4 7/8 (124)
1-inch ANSI 900/1500 lb weld neck raised face flange 919 18 7/8 (479) 5 7/8 (149)
3/4-inch NPT female union fitting 239 14 5/16 (364) 1 3/16 (30)
1-inch sanitary fitting 238 16 (406) 2 (51)
15 mm DIN PN40 weld neck, DIN 2635, type C face 116 15 7/16 (392) 3 3/4 (95)
15 mm JIS 10K weld neck raised face flange 216 15 3/16 (386) 3 3/4 (95)
15 mm JIS 20K weld neck raised face flange 118 15 3/8 (391) 3 3/4 (95)
(1)
Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.

Micro Motion D and DT Sensors 19


D100, D150, and standard-pressure D300 dimensions
inches
Dimensions in
(mm)
#10-32 UNF for
grounding (green K C
binding head screw) L D 3/8
2 (10)
(51)

1 7/16
(37) 2X 1/2-14 NPT
female purge
fitting (optional) G F E

2X 1/2-14 NPT
male hex plug
FLOW

2
(51) B

1 7/16 H
3/4-14 (37)
NPT F
3 15/16 J 2 5/16
(100) (59)
A

Dimensions(1)
Standard-pressure sensors C D E F G H J K L
D100 inches 12 1/4 6 1/8 24 3/4 23 5/16 21 9/32 4 12 7/8 4 2
(mm) (311) (156) (629) (592) (541) (102) (327) (102) (51)
D150 inches 12 1/4 6 1/8 24 3/4 23 5/16 21 9/32 4 12 7/8 4 2
(mm) (311) (156) (629) (592) (541) (102) (327) (102) (51)
D300 inches 17 8 1/2 39 7/16 36 15/16 33 27/32 4 1/2 17 7/8 7 1/4 3 5/8
(mm) (432) (216) (1002) (938) (860) (114) (454) (184) (92)

High-pressure sensors
DH100 inches 12 1/4 6 1/8 24 27/32 23 13/32 21 3/8 4 12 7/8 4 2
(mm) (311) (156) (631) (595) (543) (102) (327) (102) (51)
DH150 inches 12 3/4 6 3/8 28 11/32 26 29/32 24 29/32 4 12 7/8 4 1/2 2 1/4
(mm) (324) (162) (720) (683) (633) (102) (327) (114) (57)

(1)
For dimensions A and B, see process fittings tables, pages 21–22.

20 Micro Motion D and DT Sensors


D100 process fittings
Dim. A Dim. B
Fitting Face-to-face Outside diameter
Fittings for standard-pressure, stainless steel sensors(1) code inches (mm) inches (mm)
1-inch ANSI 150 lb weld neck raised face flange 128 17 1/8 (435) 4 1/4 (108)
1-inch ANSI 300 lb weld neck raised face flange 129 17 5/8 (448) 4 7/8 (124)
1-inch ANSI 600 lb weld neck raised face flange 130 18 1/8 (460) 4 7/8 (124)
1-inch sanitary fitting 138 16 (406) 2 (51)
25 mm DIN PN40 weld neck, DIN 2635, type C face 131 15 29/32 (404) 4 17/32 (115)
25 mm JIS 10K weld neck raised face flange 212 15 3/4 (400) 4 29/32 (125)
25 mm JIS 20K weld neck raised face flange 133 15 29/32 (404) 4 29/32 (125)

Fittings for standard-pressure, nickel alloy sensors


1-inch ANSI 150 lb lap joint flange 134 18 1/2 (270) 4 1/4 (108)
1-inch ANSI 300 lb lap joint flange 135 18 1/2 (270) 4 7/8 (124)
1-inch ANSI 600 lb lap joint flange 136 18 1/2 (270) 4 7/8 (124)
25 mm DIN PN40 lap joint flange, DIN 2656 213 18 1/2 (270) 4 17/32 (115)
25 mm JIS 10K lap joint flange 132 18 1/2 (270) 4 29/32 (125)

Fittings for high-pressure, stainless steel sensors


1 1/2-inch high-pressure clamp-type flange(2) 140 17 1/2 (445) 3 1/8 (79)
1-inch ANSI 900/1500 lb weld neck raised face flange 925 19 1/16 (484) 5 7/8 (149)
1-inch ANSI 2500 lb weld neck raised face flange 927 20 9/32 (515) 6 1/4 (159)

D150 process fittings


Dim. A Dim. B
Fitting Face-to-face Outside diameter
Fittings for standard-pressure, stainless steel sensors code inches (mm) inches (mm)
1 1/2-inch ANSI 150 lb weld neck raised face flange 141 17 5/8 (448) 5 (127)
1 1/2-inch ANSI 300 lb weld neck raised face flange 142 18 1/8 (460) 6 1/8 (156)
1 1/2-inch ANSI 600 lb weld neck raised face flange(3) 143 18 3/4 (476) 6 1/8 (156)
2-inch ANSI 150 lb weld neck raised face flange(3) 218 17 25/32 (452) 6 (152)
1 1/2-inch sanitary fitting(3) 151 16 (406) 2 (51)
40 mm DIN PN40, DIN 2635, type C face 144 16 5/16 (414) 5 29/32 (150)
40 mm JIS 10K weld neck raised face flange(3) 214 16 1/16 (408) 5 1/2 (140)
40 mm JIS 20K weld neck raised face flange(3) 146 16 3/8 (416) 5 1/2 (140)

Fittings for standard-pressure, nickel alloy sensors


1 1/2-inch ANSI 150 lb lap joint flange 147 19 1/4 (489) 5 (127)
1 1/2-inch ANSI 300 lb lap joint flange 148 19 1/4 (489) 6 1/8 (156)
1 1/2-inch ANSI 600 lb lap joint flange 149 19 1/4 (489) 6 1/8 (156)
40 mm DIN PN40 lap joint flange, DIN 2656 215 19 1/4 (489) 5 29/32 (150)
40 mm JIS 10K lap joint flange 145 19 1/4 (489) 5 1/2 (140)

Fittings for high-pressure, stainless steel sensors


1 1/2-inch high-pressure clamp-type flange(4) 154 17 1/2 (445) 3 1/8 (79)
1 1/2-inch ANSI 900/1500 lb weld neck raised face flange 936 19 25/32 (502) 7 (178)
1 1/2-inch ANSI 2500 lb weld neck raised face flange 938 22 1/32 (560) 8 (203)
(1)
Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.
(2)
Oteco hub size: 1½ OC11. Mating connectors (not included): Grayloc hub size 1½ GR11, seal ring size 11; clamp size 1½,
stainless steel.
(3)
Not available with Tefzel sensors.
(4)
Oteco hub size: 1½ OC14. Mating connectors (not included): Grayloc hub size 1½ GR14, seal ring size 14; clamp size 1½,
stainless steel.

Micro Motion D and DT Sensors 21


High-pressure DH300 dimensions, D300 and DH300 process fittings
inches 17
Dimensions in 7 1/4 (432)
(mm) 3/8
#10-32 UNF for (184) 8 1/2 (10)
2 grounding (green 3 5/8 (216)
(51) binding head screw) (92)

1 7/16
(37)
39 7/16
(1002)
2X 1/2-14 NPT
female purge 36 15/16
fitting (optional) (938)

33 27/32
2X 1/2-14 NPT (860)
male hex plug
FLOW

2
(51) Dim. B

3/4-14 1 7/16
NPT F (37)
8 3/4 17 7/8 4 1/2
3 15/16 (221) (454) (114)
(100) Dim. A 2 5/16
face-to-face (59)

Dim. A Dim. B
Fitting Face-to-face Outside diameter
Fittings for standard-pressure, stainless steel sensors(1) code inches (mm) inches (mm)
3-inch ANSI 150 lb weld neck raised face flange 155 23 1/4 (591) 7 1/2 (191)
3-inch ANSI 300 lb weld neck raised face flange 156 24 (610) 8 1/4 (210)
3-inch ANSI 600 lb weld neck raised face flange(2) 157 24 3/4 (629) 8 1/4 (210)
3-inch sanitary fitting(2) 161 21 3/8 (543) 3 19/32 (91)
80 mm DIN PN40, DIN 2635, type C face 158 22 5/16 (567) 7 7/8 (200)
80 mm JIS 10K weld neck raised face flange(2) 159 21 11/16 (551) 7 9/32 (185)
80 mm JIS 20K weld neck raised face flange(2) 160 22 5/16 (567) 7 7/8 (200)

Fittings for standard-pressure, nickel alloy sensors(1)


3-inch ANSI 150 lb lap joint flange 203 25 5/8 (651) 7 1/2 (191)
3-inch ANSI 300 lb lap joint flange 204 25 5/8 (651) 8 1/4 (210)
80 mm DIN PN40 lap joint flange, DIN 2656 211 25 5/8 (651) 7 7/8 (200)
80 mm JIS 10K lap joint flange 210 25 5/8 (651) 7 9/32 (185)

Fittings for high-pressure, stainless steel sensors(1)


4-inch high-pressure clamp-type flange(3) 164 25 1/16 (634) 6 (151)
3-inch ANSI 300 lb weld neck raised face flange 156 24 (610) 8 1/4 (210)
3-inch ANSI 600 lb weld neck raised face flange 157 24 3/4 (629) 8 1/4 (210)
3-inch ANSI 900 lb weld neck raised face flange 246 26 5/16 (668) 9 1/2 (241)
3-inch ANSI 1500 lb weld neck raised face flange 946 27 9/16 (700) 10 1/2 (267)
3-inch ANSI 2500 lb weld neck raised face flange 947 31 9/16 (802) 12 (305)
(1)
Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.
(2)
Not available with Tefzel sensors.
(3)
Oteco hub size: 4 OC27. Mating connectors (not included): Grayloc hub size 4 GR27, seal ring size 27; clamp size 4, stainless
steel.

22 Micro Motion D and DT Sensors


D600 dimensions and process fittings
inches
Dimensions in
(mm)

Snub-mount connector

16 1/2 33 3/4
(419) (858) 2 9/16
(65)

68 11/16
(1745)

75 7/16
(1916)

#10-32 UNC for


80 13/16
grounding
(2053)

1/2-14 NPT F FLOW


conduit opening

Dim. B

12 1/2
(318) 36 1/2-14 NPT F
(914) conduit opening

Dim. A
face-to-face

Dim. A Dim. B
Fitting Face-to-face Outside diameter
Fittings(1) code inches (mm) inches (mm)
6-inch ANSI 150 lb weld neck raised face flange 165 43 (1092) 11 (279)
6-inch ANSI 300 lb weld neck raised face flange 166 43 3/4 (1111) 12 1/2 (317)
150 mm DIN PN40 weld neck, DIN 2635, type C face 167 42 1/16 (1068) 11 55/64 (301)
150 mm JIS 10K weld neck raised face flange 168 40 15/32 (1028) 11 1/16 (281)
150 mm JIS 20K weld neck raised face flange 169 42 1/16 (1068) 12 1/16 (306)
(1)
Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.

Micro Motion D and DT Sensors 23


DT sensor dimensions and process fittings
inches
Dimensions in
(mm)

F 2X lifting handle 2 3/4


(70)

H
C

G 4 1/2
(114)

FLOW
Grounding
bolt

D A

Dimensions
High-temperature sensors C D E F G H
DT65 inches 25 1/2 9 5 1/2 15 1/2 20 16
(mm) (648) (229) (140) (394) (508) (406)
DT100 inches 29 1/2 10 6 1/2 17 1/2 24 18
(mm) (749) (254) (165) (444) (610) (457)
DT150 inches 35 1/2 11 1/2 8 20 1/2 30 21
(mm) (902) (292) (203) (521) (762) (533)

Dim. A Dim. B
Fitting Face-to-face Outside diameter
Fittings for DT65 sensors(1) code inches (mm) inches (mm)
1/2-inch ANSI 300 lb weld neck raised face flange 114 23 7/8 (606) 3 3/4 (95)
1/2-inch ANSI 600 lb weld neck raised face flange 115 23 7/8 (606) 3 3/4 (95)
15 mm DIN PN40 weld neck, DIN 2635, type C face 116 22 3/4 (578) 3 3/4 (95)
15 mm JIS 20K weld neck raised face flange 118 22 3/4 (578) 3 3/4 (95)

Fittings for DT100 sensors(1)


1-inch ANSI 300 lb weld neck raised face flange 129 29 23/32 (755) 4 7/8 (124)
1-inch ANSI 600 lb weld neck raised face flange 130 30 7/32 (768) 4 7/8 (124)
25 mm DIN PN40 weld neck, DIN 2635, type C face 131 28 (711) 4 17/32 (115)
25 mm JIS 20K weld neck raised face flange 133 28 (711) 4 59/64 (125)

Fittings for DT150 sensors(1)


1 1/2-inch ANSI 300 lb weld neck raised face flange 142 39 1/32 (992) 6 1/8 (156)
1 1/2-inch ANSI 600 lb weld neck raised face flange 143 39 43/64 (1008) 6 1/8 (156)
40 mm DIN PN40 weld neck, DIN 2635, type C face 144 37 13/64 (945) 5 29/32 (150)
40 mm JIS 20K weld neck raised face flange 146 37 13/64 (945) 5 33/64 (140)
(1)
Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.

24 Micro Motion D and DT Sensors


Ordering Information
Model D, standard-pressure sensors, model number matrix

Code Sensor model


DS025 D25 1/4-inch sensor, standard pressure
DS040 D40 3/8-inch sensor, standard pressure
DS065 D65 1/2-inch sensor, standard pressure
DS100 D100 1-inch sensor, standard pressure
DS150 D150 1 1/2-inch sensor, standard pressure
DS300 D300 3-inch sensor, standard pressure
DS600 D600 6-inch sensor, standard pressure

Code Wetted material


S 316L stainless steel
H Hastelloy ® C-22 nickel alloy — not available with DS065 or DS600
Z 316L stainless steel with Tefzel ® lining — DS150 and DS300 only

Code Process connections


### See fittings tables on pages 17-23

Code Case option


S Standard pressure containment
P Purge fittings — (2) 1/2" NPT female; not available with DS600
D Metal rupture disk — not available with DS600

Code Approvals
M Micro Motion standard — no approvals
U UL intrinsically safe — U.S.A. approvals agency
C CSA — Canadian approvals agency, not available with DS600
B CENELEC — European approvals agency
S SAA — Australian approvals agency, not available with DS600

Code Booster amplifier power voltage — D600 only


1 110/115 VAC
2 220/230 VAC

Example*
DS025 S 113 S U

*Example: DS025 S 113 S U = Model D25 1/4-inch standard-pressure sensor, 316L stainless steel; 1/2-inch ANSI 150 lb weld
neck raised face flanges; standard pressure containment; UL approved for intrinsically safe installations

Micro Motion D and DT Sensors 25


Ordering Information continued
Model DH, high-pressure sensors, model number matrix

Code Sensor model


DH025 DH25 1/4-inch sensor, high pressure
DH038 DH38 3/8-inch sensor, high pressure
DH100 DH100 1-inch sensor, high pressure
DH150 DH150 1 1/2-inch sensor, high pressure
DH300 DH300 3-inch sensor, high pressure

Code Wetted material


S 316L stainless steel

Code Process connections


### See fittings tables on pages 17-22

Code Case option


S Standard pressure containment
P Purge fittings — (2) 1/2" NPT female, not available with DH100, DH150, or DH300
D Metal rupture disk — not available with DH100, DH150, or DH300

Code Approvals
M Micro Motion standard — no approvals
U UL intrinsically safe — U.S.A. approvals agency
C CSA — Canadian approvals agency
B CENELEC — European approvals agency
S SAA — Australian approvals agency

Example*
DH038 S 119 S U

*Example: DH038 S 119 S U = Model DH38 3/8-inch high-pressure sensor, 316L stainless steel; 3/8-inch NPT female union
fittings; standard-pressure case; UL approved for intrinsically safe installations

26 Micro Motion D and DT Sensors


Ordering Information continued
Model DT, high-temperature sensors, model number matrix

Code Sensor model


DT065 DT65 1/2-inch sensor, standard pressure, high temperature
DT100 DT100 1-inch sensor, standard pressure, high temperature
DT150 DT150 1 1/2-inch sensor, standard pressure, high temperature

Code Wetted material


H Hastelloy ® C-22 nickel alloy

Code Process connections


### See fittings tables on page 24

Code Case option


G Standard high-temperature case

Code Approvals
M Micro Motion standard — no approvals
U UL intrinsically safe — U.S.A. approvals agency
C CSA — Canadian approvals agency
B CENELEC — European approvals agency

Example*
DT100 H 129 G U

*Example: DT100 H 129 G U = Model DT100 1-inch, standard-pressure, high-temperature sensor; Hastelloy ® C-22 nickel alloy;
1-inch ANSI 300 lb weld neck raised face flanges; standard high-temperature case; UL approved for intrinsically safe
installations

Micro Motion D and DT Sensors 27


Due to Micro Motion’s commitment to continuous improvement of our products, all specifications are subject to change without notice. Micro Motion is a
registered trademark of Micro Motion, Inc., Boulder, Colorado. PlantWeb is a registered trademark of Fisher-Rosemount, Clayton, Missouri. Hastelloy is a registered
trademark of Haynes International, Inc., Kokomo, Indiana. Tefzel is a registered trademark of E.I. Du Pont de Nemours Co., Inc., Wilmington, Delaware.

For the latest Micro Motion product specifications, view the


PRODUCTS section of our Web site at at www.micromotion.com

Micro Motion Europe Micro Motion Asia


Groeneveldselaan 8 1 Pandan Crescent
3903 AZ Veenendaal Singapore 128461
The Netherlands Republic of Singapore
Tel +31 (0) 318 549 549 Tel (65) 777-8211
Fax +31 (0) 318 549 559 Fax (65) 770-8003

Micro Motion Inc. USA Micro Motion Japan


Worldwide Headquarters Shinagawa NF Bldg. 5F
7070 Winchester Circle 1-2-5, Higashi Shinagawa
Boulder, Colorado 80301 Shinagawa-ku
Tel (303) 530-8400 Tokyo 140-0002 Japan
(800) 522-6277 Tel (81) 3 5769-6803
Fax (303) 530-8459 Fax (81) 3 5769-6843

© 2000, Micro Motion, Inc.


All rights reserved
PS-00388 (1/00)