Gasketed Plate Heat Exchangers

NT SERIES:
THE MOST VERSATILE PHE

Kelvion’s NT Series is our most advanced gasketed plate heat NT Features:


exchanger. It features compact designs, wide varieties of material • Wide variety of material and design choices
choices, plate configurations, and connection sizes. Maximum • Compact footprint
flow rate up to 20,000 gpm. Pressure rating up to 360 psi makes • Higher performance at a lower cost
the NT Series a versatile heat exchanger suited to a wide variety • Easier maintenance features
of heat transfer applications. • Reduced fouling rate for less-than perfect media
The interior NT Plates are the most technologically advanced heat • 3D drawings available
transfer plates on the market with features for efficient processing
of all products, including those with high viscosities and fouling
tendencies.
NT Series: Technical Data

Heat Transfer Plate: 316L Stainless, 304 Stainless, Titanium, Approximate Maximum Liquid Flow Rate:
Hastelloy, 904L, SMO 254, and others are available
NT25: 50 gpm (11 m3/hour)
Gasket: NBR, EPDM, Viton, and others are available NT50: 200 gpm (45 m3/hour)
NT80: 500 gpm (110 m3/hour)
Pressure Plate: Carbon Steel, Stainless Steel, and others are
NT100: 800 gpm (180 m3/hour)
available
NT150: 1770 gpm (400 m3/hour)
Port Connection: Unlined, Metal Lined (Stainless, Titanium and NT250: 4900 gpm (1110 m3/hour)
others on request), Welded Neck Flange, threaded nipple, and NT350: 9600 gpm (2180 m3/hour)
others are available NT500: 20,000 gpm (4450 m3/hour)
Maximum Standard Design Pressure: 360 psig (25 bar) Higher Additional Options: Inline Strainer, Backflush Valve, Drip Tray,
pressures are available, depending on application Insulation and Shroud.
Maximum Standard Design Temperature: 330°F (170°C) Higher
temperatures are available

Connection Standard Frame Dimensions


Model Size Inches (mm)

Nominal A B C

7.1" 22.5" Up to 18"


NT 25 M 1" (457 mm)
(180 mm) (572 mm)
26.6"
NT 50 T
(675 mm)
12.7" 40.4" Up to 44"
NT 50 M 2"
(323 mm) (1025 mm) (1120 mm)
54.9"
NT 50 X
(1395 mm)
17.1" 49.8" Up to 127"
NT 80 M 3" (3230 mm)
(435 mm) (1266 mm)
51.1"
NT 100 T
(1298 mm)
23.0" 67.5" Up to 158"
NT 100 M 4"
(584 mm) (1716 mm) (4013 mm)
83.52"
NT 100 X
(2121 mm)
*Approximate, varies with design requirements 70.1"
*NT150 shown. Lifting point locations vary by model NT 150 S
26.2" (1781 mm) Up to 159"
6"
(665 mm) 89.4" (4039 mm)
NT 150 L (2271 mm)
89.5"
NT 250 S (2273 mm)
35.2" 99.6" Up to 159"
NT 250 M 10" (895 mm) (2529 mm) (4039 mm)
112.8"
NT 250 L
(2866 mm)
115.4"
NT 350 S
(2930 mm)
44.7" 128.6" Up to 238"
NT 350 M 14"
(1134 mm) (3267 mm) (6045 mm)

NT 350 L 141.9"
(3604 mm)
NT 500 T 128"
(3251 mm)
The specifications contained in this printing are intended only to serve the non-
55" 152" Up to 290"
binding description of our products and services and are not subject to guarantee. NT 500 M 20"
Binding specifications, especially pertaining to performance data and suitability for
(1397 mm) (3861 mm) (7366 mm)
specific operating purposes, are dependent upon the individual circumstances at the NT 500 X 176"
operation location and can, therefore, only be made in terms of precise requests. (4470 mm)
Optiwave™ Plate Pattern

What Makes OptiWave™ Better?


Superior design. Conventional plates allow media to flow
directly from one port to the other, reducing the flow in the
corner farthest from the inlet port. This “short circuiting”
reduces the effective use of the available heat transfer area,
potentially requiring more heat transfer plates and lowering
the heat transfer coefficient when compared to Optiwave.
Optiwave plates provide even media velocity over the entire
width of the plate via enhanced fluid distribution allowing the
Optiwave plate to make full use of the available heat transfer
area. Improved distribution can also reduce the required
surface area providing higher heat transfer coefficients, lower
capital costs for customers, and longer run times. Plates with
Conventional Design Distribution OptiWave Design Distribution
Optiwave deliver a better return on investment.
Low velocity at the far corner Even velocity across the entire
reduces plate performance. plate width.

Why PosLoc™ Is The Best In The Industry Plate Alignment Guides Corner Lead-Ins
Plates with PosLoc™ allow the PHE to tightly seal every time
it is closed. The plate pack has corner lead-ins that use the
compression force of the pressure plates to self-align the
heat transfer plates, virtually eliminating plate pack snaking.
Shoulders on all gasket flaps cradle each plate as the unit
closes and bring the plate pack into alignment. PosLoc™
plate packs will self-align even if the frame is out of alignment
and after repeated servicing. The benefit to you is years of
smooth and hassle free maintenance and operation.

How EcoLoc™ Can Help You


Our gaskets work in perfect combination with our plates to ensure worry free operation. Our chamfered opening allows each gasket
to settle into position and prevents the lock tab from being severed. Gaskets can be easily installed without tools or adhesive and self-
seat during unit closing. It takes just seconds to replace a gasket making maintenance quick and easy.

Kelvion