Huawei Solution

Optimal Configuration Get mobile version

Issue 02
Quorum Server Date 2018-06-15
 Quorum software must be deployed on an x86
server. The server's system disks and data
disks must not be provided by the LUNs or file
systems on the HyperMetro storage systems.
Hardware
 Deploy the quorum server at a dedicated site.
If no such site is available, configure an
uninterruptible power supply for the quorum Storage System
server.
Both storage systems must use the same model,
Interoperability  For the quorum server's OS, see the
Navigator hardware, and software version.
OceanStor Interoperability Navigator.

Networking Between Storage Systems


 Links between storage systems use parallel
(A-A, B-B...) redundant networking (two links
for each controller).
Quorum Server to Storage Systems  When the storage systems are over 10 km
The quorum server must have at least one link to apart, use 8 Gbit/s FC, 10GE, or SmartIO
each controller on both storage systems. (10GE) interface modules to connect them
and enable Fast Write.
Host to Storage Systems General Suggestions
Each host must have at least one link to each The three networks (quorum server to storage
HyperMetro storage system controller. systems, host to storage systems, between
storage systems) must use different ports on
General Suggestions the storage systems.
 The LUNs or file systems in a HyperMetro pair
should have the same owning controller.
 The LUNs or file systems in a HyperMetro pair
should have the same type, capacity, and
SmartDedupe and SmartCompression policies. Software
HyperMetro for SAN
 HyperMetro pairs running the same service
must be added to a consistency group. HyperMetro for NAS
 Both storage systems must have the same
SmartTier, SmartQoS, and SmartPartition  Logical ports (LIF) must be created on both
policies. storage systems.
 The HyperMetro LUNs on both storage  The secondary file system must be newly
systems are mapped to the same hosts. created.
 For the AIX/Linux/Solaris/Windows/VMware  Use NFSv3/v4 to mount shares for non-
OS, use OceanStor UltraPath. disruptive failover.
 To use OS native multipathing software, follow  HyperMetro pairs running the same service
the instructions in Huawei SAN Storage Host must be in the same vStore pair.
Connectivity Guide for XXX.
Obtain Document *Log in to support.huawei.com/e and search for
"Host Connectivity Guide".

Inspection
After configuration, use OceanStor Toolkit to
conduct a site deployment inspection and output
an inspection report. Obtain Toolkit
Verification
Acceptance Test
See the HyperMetro acceptance cases in your
product model's Acceptance Test Guide.
*Log in to support.huawei.com/e and search for Obtain Document
"product model + acceptance test guide".

You might also like