Document Number: AST-AD-170912-01

Initial Date: 12h Sep. 2017


Revised Date: 12th Sep. 2017 / Rev.00

“More than just Digital”

Digital Flat Panel X-ray Detectors

Auto Exposure Detection (AED)

Slim Design & Light Weight

Large Active Area for Image

www.astel.co.kr
Document Number: RS-AD-170912-02
Initial Date: 12h Sep. 2017
Revised Date: 12th Sep. 2017 / Rev.00
DRA-1717S

Wide and Slim Flat Panel Detector


for Digital Radiography!

Model & Parameters DRA-1717SG DRA-1717SC


Scintillator Gd2O2S:Tb CsI:Tl (Direct)
Pixel size 140um, a-Si TFT active matrix with PIN diode
Pixel Matrix 3072 x 3072
Sensor
Effective Area 427.8 x 427.8 mm
Effective Array 3056 x 3056
Spatial Resolution 3.4 lp/mm
ADC Resolution 16 bits
Grayscale 65536 grayscales
Image performance x-ray voltage Range 40 ~ 150 Kvp

X-ray Generator Interface Line Trigger(Manual)/ Auto Trigger(AED Mode)

Shot Mode Single / Multi


Weight Gd2O2S:Tb / 3.40 Kg CsI :TI / 3.50 kg
Mechanical
Dimensions Meet ISO4090 cassette size(460x460x15mm)

Wired Giga Ethernet (1000BaseT)


Sync. Out Port 2 port / TTL(0~5.0V)
Communications
Operation Software Window 7,8,10
(Console S/W) Support for 32/64bits Windows

Power/ Wired DC +15V


Environment
Environment T(10~+40)/H(20 ~ 75%)/P(70~106KPa)

26-79, Gajeongbuk-ro, Yuseong-gu, Daejeon, 34113, Korea


Document Number: RS-AD-170912-03
Initial Date: 12h Sep. 2017
Revised Date: 12th Sep. 2017 / Rev.00
DRA-1417M

Portable Flat Panel Detect


or for Digital Radiography!

Model & Parameters DRA-1417MG DRA-1417MC


Scintillator GD2O2S:Tb CsI:Tl (Indirect)

Sensor Pixel size 140um, a-Si TFT active matrix with PIN diode
Pixel Matrix 2500x 3052

Effective Area 347.8x 425.04mm

Effective Array 2484 x 3036

Image Spatial Resolution 3.4 lp/mm 3.4 lp/mm


performance
ADC Resolution 16 bits

Grayscale 65536 grayscales

x-ray voltage Range 40 ~ 150 Kvp

X-ray Generator Interface Line Trigger(Manual)/ Auto Trigger(AED Mode)

Shot Mode Single / Multi

Mechanical Weight GD2O2S:Tb / 3.0 Kg CsI / 3.2 kg

Dimensions Meet ISO4090 for cassette size (384x460x15mm)

Communications Wired Giga Ethernet (1000BaseT)

Wireless IEEE802.11n/2.4 or 5Gbps

Sync. Out Port 2 port / TTL(0~5.0V)

Operation Software Windows 7/8/10:


(Console S/W) Support for 32/64bits Windows

Power/ Wired DC +15V


Environment Wireless Max. 1 Pack(Battery/11.8V/ 4 hour)

Environment T(10~+40)/H(20 ~ 75%)/P(70~106KPa)

26-79, Gajeongbuk-ro, Yuseong-gu, Daejeon, 34113, Korea


Document Number: RS-AD-170912-03
Initial Date: 12h Sep. 2017
Revised Date: 12th Sep. 2017 / Rev.00
RFA-1717DI

Superior-quality
Dynamic Panel Detector for
Radiography and Fluoroscopy!

Model & Parameters RFA-1717DIG RFA-1717DIC


Scintillator GD2O2S:Tb CsI:Tl (Indirect)

Sensor Pixel size 140um, IGZO TFT active matrix with PIN diode
Pixel Matrix 3072 x 3072
Effective Area 427.8 x 427.8 mm
Effective Array 3056 x 3056
Image Spatial Resolution 3.4 lp/mm
performance ADC Resolution 16 bits
Grayscale 65536 grayscales

x-ray voltage Range 40 ~ 150 Kvp


X-ray Generator Line Trigger(Manual)/ Auto Trigger(AED Mode)
Shot Mode Continuous/Pulsed
Mechanical Weight GD2O2S:Tb / 3.0 Kg CsI / 3.2 kg
Dimensions Meet ISO4090 cassette size(460x460x15mm)
Maximum Frame 12 fps @ 1x1 (3052 x 3052)
Rate 25 fps @ 2x2 (1536 x 1536) NBIC
25 fps @ 2x1 (3052 x 3052) BIC
18 fps @ 1x1 (2048 x 2048) FOV-1
25 fps @ 1x1 (1536 x 1536) FOV-2
38 fps @ 1x1 (1024 x 1024) FOV-3
35 fps @ 1x1 (2560 x 1024) FOV-4
75 fps @ 1x1 ( 512 x 512) FOV-5

Communications Wired Giga Ethernet (1000BaseT)


Sync. Out Port 2 port / TTL(0~5.0V)
Operation Software Windows 7/8/10:
(Console S/W) Support for 32/64bits Windows
Power/ Wired DC +15V
Environment Environment T(10~+40)/H(20 ~ 75%)/P(70~106KPa)

26-79, Gajeongbuk-ro, Yuseong-gu, Daejeon, 34113, Korea


“More than just Digital”

26-79, Gajeongbuk-ro, Yuseong-gu, Daejeon, 34113, Korea