Department of Research & Development
Fan Performance Testing Laboratory
TEST REPORT
Subject: Maximum Air Delivery for DC Ceiling Fan
Report Number: xx/xxxx/xxxx Date of Test: 06/ 04 / 2024
Results
Requirement -Test Result/Remarks
Specifications of the Product Model No. ECFP231B Brand Name Polycrome Viera Blade Description Kumbuk Finished / 52 inch Light Kit (Y/N) Y Color Temperature Light 3000K / 4500K / 6000K Rated Power Fan 55W Rated Power Light 24W Max. Current Fan 0.4A Max. Current Light 0.2A Input Voltage 220 – 240 V Frequency 50/60 Hz Method of Testing Test Voltage 229.79 V Test Frequency 50.12 Hz Ambient Temperature 34.37 0C Test Method Measurement shall be conducted for each position in 3 different radial axes at the maximum speed. Table: Maximum Air Delivery, Power Input and Power Factor of the Fan Test Results Measurement Position Distance from Center (mm) Average Velocity (ms-1) Air Delivery (CMM) 1 0 0.25 2 94.3 0.43 3 88.7 0.66 4 283.0 1.42 5 377.4 2.12 170.91 6 471.7 2.34 7 566.1 2.39 8 660.4 1.49 Average Power (W) 75.17 W Average Power Factor 0.49 CMM/W 2.27 Test Layout Pos. 8 Pos. 7 Pos. 6 Pos. 5 Pos. 4 Pos. 3 Pos. 2 Pos. 1