1.Install NI GPIB and NI VISA driver. More details see the documentation for installation of NI GPIB and NI VISA driver.
Connect one or more instruments to the GPIB connector on the PC.
Run NI Max. NI Max will automatically detect and configure the interface and instruments and will
assign names and other default configuration settings.
To verify that the computer recognized the instrument, expand USB/GPIB (GPIB0) in the Devices
and I/O on this PC section. NI Max will list all instruments and their addresses. If problems, refer to
the troubleshooting chapter in the GPIB User’s Guide.
PART 3. Configuring the USB/GPIB Interface
Note: 1.The GPIB addresses of devices connected to the same station cannot be repeated, otherwise the NIMAX scan
will fail.
2.In order to facilitate debugging and maintenance of all devices, it is best to fix the GPIB address.
SMW200A GPIB address: 20 SMB100B GPIB address: 6 Another SMB100B GPIB address: 7
N5766A Power Supply GPIB address: 5 FSV3004 IP address: 172.158.100.10 HP8921A GPIB address: 1
PART 4. Test software general settings
1.Click "ATE System", select the TestPlan corresponding to the product, and click "OK"
PART 4. Test software general settings
2.Click the key icon Type in Password: “th” and click OK button enter Administrator Mode
PART 4. Test software general settings
3.General Configuration
Enable Automatic Increase SN:
Product Serial Number add one per test, Default configuration “false”
Enable get SN From EEPROM:
Read Serial Number from product instead of input manually, Default
configuration “true”
If you need to write SN, you need to change it to "false"
Enable SN Pattem Check:
Check whether Serial Number conforms to the rules
SN Pattem:
Serial Number pattern, * character is wildcard
Enable SN Length Check:
Check Serial Number length
SN Length:
Serial Number length
Clean Up SN When Finished:
Cleanup Serial Number display in test main application window when
test finished
PART 4. Test software general settings
4.Test report format and storage path can be selected
PART 4. Test software general settings
5.Configure the ATE software based on the instrument GPIB address scanned by NI MAX
PART 4. Test software general settings
6.Transmit path RF cable loss setting,Click “FSV”, Double click “Loss”
PART 4. Test software general settings
7.In the dialog box, modify the actual line loss of the RF path, and then click OK
PART 4. Test software general settings
8.Receive path RF cable loss setting,Click “SMU200”, Double click “Loss”
PART 4. Test software general settings
9.General settings Modification is complete Click Save.After the modification is completed, click the key
icon to exit the administrator mode.
PART 5. Waterproof automated test control process
1.Waterproof automated test control process
Scan SN to
start the test
Question 8. The whole machine is defective. Replace the mainboard. Software upgrade and information writing are required.
Solution:Subsequent software upgrades/information writing completed Mainboards will be provided