Technical Data

Document Reference R1203


18/02023

RAMCRO - DATA LAN - M-BUS Cable


For standard applications, flame retardant.

Single pair, PVC-Insulation, UnScreened, PVC-Sheath

MSE0105HBAAN-T-RB
Application
M-BUS (Meter-Bus) is a european standard (EN 13757-2) physical and lnk layer, EN 13757-3 application layer) for the remote reading of gas or electricity meters. M-Bus is
also suitable for other types of consumption meters.

Construction
Nominal
Formation 1 Pair Unit Value
Section 18 AWG
Conductor Tinned copper wire, 7 strand mm 1,1
Insulation Polyetilene - PE mm 1,7
Colour Code Black, White

Individual Screen N.A.


Wrapping at least 1 layer of plastic tape 0,023 mm
Collective Screen N.A.

Inner Sheath N.A.


Armour N.A.
Outer Sheath Polyvinyl chloride - PVC - Grey RAL 7001 mm 4,8
RAMCRO ITALY R1203 DATA LAN CABLE 1PR 22AWG UNSCREENED 300 V 75 C
Cable Printing
IEC 60332-1/UL 1581 - MSE0105HBAAN-T-RB - "PROD.WEEK/18" + BATCH +
METER MARKING

Technical Data & Standard References


Fire Propagation:
- Test on single cable IEC 60332-1
- Test on bunched cables IEC 60332-3
Type of Cable: DATA LAN - M-BUS Cable
Low Voltage Directive 2014/35/UE
Limiting Oxygen Index (LOI) (min 30%) Other References:
Smoke Density IEC 61034
Amount of halogen acid gas IEC 60754-1 (max 15%)
Acidity (ph value) and conductivity IEC 60754-2
Sunlight resistance UL 1581 section 1200
Notes

Electrical & Mechanical Data

Conductor Cross-section Nom. 18 AWG Temperature Range:


DC Resistance per core at 20° C max Ω/km 23,2 During Operation °C -30°C up to 80°C
Insulation Resistance at 20° C min MΩ*km 5000 During Installation °C -30°C up to 80°C
Nominal Mutual Capacitance pF/ft 18.24
Inductance max mH/km 1 Min. Bending Radius mm 8 x cable diameter
Test Voltage - Core/Core V 2000 Max Pulling Tension N/mm2 43
Test Voltage - Core/Screen V 2000 Weight Approx kg/km 33
Standard Put Up Length ft 1000
Operating Voltage V 300

Issued by: RAMCRO S.p.A. Date of issue:


Prepared by RAMCRO Tech Via Marzorati, 15 - 20014 Nerviano - Milan - Italy / www.ramcro.it 05/06/2018 00:00
Creator: LDG Transfer to third parties only under authorization by Ramcro S.p.A. Empty Form
Printing errors excepted. Subject to alterations.