PROJECT: PROPOSED TWO-STOREY RESIDENTIAL DATE: 3/4/2022

LOCATION: CABANATUAN CITY, NUEVA ECIJA ENGINEER: CGH


OWNER: MR. DELA CRUZ

WIND DESIGN PRESSURE CALCULATION C&C(Roof)


*Input on blue cells only *According to NSCP 2015 7th Ed. 2nd Printing
Section 207A - General Requirements: *Use with NSCP 2015 on hand
V= 260 kph *See Figure 207A.5-1A,5-1B,5-1C
Kd= 0.85 *See Table 207A.6-1 h3 (h3)/2
Exposure= B *See Section 207A.7
Kzt= 1 *See Section 207A.8 h2
Enclosure= enclosed *See Section 207A.10
Gcpi= 0.18 *See Table 207A.11-1 h1
Occupancy= 4 *Standard Occupancy
NGL
Building Information:
h1= 2.7 m *Ground to 2nd floor
h2= 2.4 m *2nd floor to Roof beam
h3= 0.8 m *Roof beam to apex Roof θ= 17.745 deg
h= 5.5 m *Roof Mean Height Purlin Spacing= 0.62 m
Eff. Wind Area= 4.34 sqm
B= 5 m *Perpendicular to Wind Direction *Purlin spacing x purlin length
L= 7 m *Parallel to Wind Direction

External pressure coefficient: *See Figure 207E.4-2(A/B/C)


Zone 1 2 3
+GCp= 0.4 0.4 0.4
-GCp= -0.83 -1.4 -2.25

Velocity pressure:
α= 7 kh= 0.60588
zg= 365.76 qh= 1646.67 Pa

Dimension "a" Calculation:


0.10L or B= 0.5 m 4%L/B= 0.2 m
0.4h= 2.2 m dim= 0.9 m

use a= 0.9 m

Zones
Wind Design Pressure: Section 207E.4 (Envelope Procedure) in kPa
*Negative Pressure *Positive Pressure
Zone 1 2 3 Zone 1,2,3
-(Gcpi) -1.0703379689733 -2.00894203407 -3.4086148 -(Gcpi) 0.9550708
+(Gcpi) -1.6631405364047 -2.6017446015 -4.0014173 +(Gcpi) 0.3622682
*Use maximum values from -(Gcpi) and +(Gcpi) for each surfaces