Dcm1500s Manual 285f
Dcm1500s Manual 285f
User Guide
5 Commonwealth Ave
Woburn, MA 01801
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
2 DCM1500S User Guide
This manual supersedes all previous issues of this manual. Please ensure that you are
using the most recent issue of this document. Destroy any copies that are of an older
issue.
Declaration of Conformity
Hereby, Megger Instruments Limited declares that radio equipment manufactured by
Megger Instruments Limited described in this user guide is in compliance with Directive
2014/53/EU. Other equipment manufactured by Megger Instruments Limited described
in this user guide is in compliance with Directives 2014/30/EU and 2014/35/EU where they
apply.
The full text of Megger Instruments EU declarations of conformity are available at the
following internet address
megger.com/company/about-us/eu-dofc
G WARNING
Identify hazardous conditions and actions that could cause BODILY HARM or DEATH
When using test leads or probes, keep your fingers behind the finger guards.
Personal protective equipment should be used if there are ACCESSIBLE
HAZARDOUS LIVE PARTS in the installation where measurement is to be carried
out.
Remove test leads from meter before opening the battery door or meter case.
Use the meter only as specified in this manual; otherwise, the protection provided
by the meter may be impaired.
Always use the proper input terminals, switch position, and range for
measurements.
Verify the meters operation by measuring a known voltage. If in doubt, have the
meter calibrated.
Do not apply more than the rated voltage, as marked on the meter, between
terminals or between any terminal and earth.
Use caution with voltages above 30 V AC rms, 42 V AC peak, or 60 V DC. These
voltages pose a shock hazard.
To avoid false readings that can lead to electric shock and injury, replace the
battery as soon as the low battery indicator blinks.
Disconnect circuit power and discharge all high-voltage capacitors before testing
resistance, continuity, diodes, or capacitance.
Do not use the meter around explosive gas or vapour.
To reduce the risk of fire or electric shock do not expose this product to rain or
moisture.
Probe assemblies to be used for MAINS measurements shall be RATED as
appropriate for MEASUREMENT CATEGORY III or IV according to EN 61010-
031 and shall have a voltage RATING of at least the voltage of the circuit to be
measured.
G CAUTION
Disconnect the test leads from the test points before changing the position of the
function rotary switch.
Never connect a source of voltage with the function rotary switch in Ω, and
position.
Do not expose the meter to extremes of temperature or high humidity.
DC measurement
AC measurement
Battery
Earth
Conforms to EU directives
Bluetooth®
CATIV
Measurement category IV: Equipment connected between the origin of the low-voltage
mains supply outside the building and the consumer unit.
CATIII
Measurement category III: Equipment connected between the consumer unit and the
electrical outlets.
CATII
Measurement category II: Equipment connected between the electrical outlets and the
user’s equipment.
G Unsafe Voltage
To alert you to the presence of a potentially hazardous voltage, when the tester
detects a voltage ≥30 V or a voltage overload (OL) in V, mV, PV. The
displayed.
V symbol is
6 DCM1500S User Guide
Features
Upon removing your new Solar/PV Clamp Meter from its packing, you should have the
following items:
Function Button
1 JAW
2 VoltSeek LED
3 Push button
4 Trigger
5 Rotary switch to turn the instrument On / Off and select a function
6 6,000 count LCD display
7 Positive input terminal
8 Common (earth reference) input terminal
Measuring Voltage
PV String
Turn the switch and press the Function button to select AC/DC mode
G CAUTION
This function is only available with the dedicated PVHV test lead sets.
The PVHV test leads are designed for use in environments that are not directly
connected to the mains. Always select correct AC/DC mode to perform any high voltage
measurement.
The meter will flash this symbol F and the correct mode symbol (AC/DC) if the input
voltage is different and/or dangerous.
GCAT IV 600 V
CAT III 1000 V
Turn the switch and press the Function button to select AC/DC/Hz mode.
Note: The torch will turn on when the jaw is opened.
Turn the switch and press the Function button to select the measuring function
Function
button
K Type
Temperature
Probe
Vent / Pipe
Turn the switch and press the Function button to select °C / °F mode.
(Example)
Flame sensor
Control
module
Turn the switch and press the Function button to select AC/DC mode.
Switch
Function
Position
Press the Function button to change the function for each rotary switch position.
Function
button
Backlight
Press
> 2 sec
2 sec
The MIN/MAX mode records the min and max input values.
When the input goes below the recorded min value or above the recorded max value, the
meter beeps and records the new value. Press Hold button to pause the recording.
Sensor position
Do not hold
across this line
when sensing the
hazardous voltage
Volt Seek
2 sec
Press MIN/MAX button for over 2 seconds to enter/exit Volt Seek mode. Press MIN/MAX
button to switch from high to low sensitivity.
G WARNING
The Volt Seek LED indicates the electric field. If the Volt Seek LED is not on, voltage could
still be present.
The meter will beep continuously, and the display will flash if the measured signal is larger
than the display reading by 50 counts.
DCA ZERO
Remove the clamp from the conductor before performing DCA ZERO.
Press the HOLD button for over 2 seconds to compensate for any residual magnetism.
Press
> 2 sec
Press
> 2 sec
The High Frequency Rejection (HFR) mode uses a low pass filter when taking AC
measurements. The cut-off frequency (-3 dB point) of the low pass filter is 800 Hz.
Press
F WARNING
Hazardous voltages may still be present when the LCD reading is very low in HFR mode.
Verify the voltage again without HFR mode activated.
When using the inrush current mode, select a suitable measurement range before pressing
the HFR/INRUSH button and triggering the inrush current measurement feature.
Detecting
Press
> 2 sec
Inrush
2 sec
Press
> 2 sec The current is > trigger level
Inrush
2 sec
Function
Button
Function
Button
Press and hold the function button whilst turning the meter on, the meter beeps 3 times
prior to APO (Auto Power Off) activating.
Release the function button and press it again to select the desired time. The auto power
off time can be set to 5 mins,10 mins, 20 mins, or disabled (OFF).
Press
Press the Bluetooth® button while powering-up to select the Logger mode,
Manual Saving mode or Clear the memory.
Press Press
Press
G CAUTION
All stored data is cleared at the start of each data log or when Clr (Clear) or Save
(Manual Saving) is selected. Data can be downloaded and saved for analysis by the
Megger Link App.
Flash
Press
> 2 sec
To save a reading
If Manual Saving is selected, readings can be stored by pressing the Hold/Zero button
when in Log mode. The sample location is displayed on each button press.
G CAUTION
All stored data is saved until switching to data logger mode or executing the clear
function.
The meter uses Bluetooth® low energy (BLE) V4.0 wireless technology to transfer the real-
time reading and the stored data. The open-air communication range is up to 10 meters.
Download the “Megger Link” App. Turn on the Bluetooth function of the meter by
pressing the Bluetooth button and open the Megger Link App to connect the DCM.
The Bluetooth icon of the meter will flash whilst connecting and remain on the LCD once
the connection is established.
QR Code for the Megger Link App QR Code for the Megger Link App
on the Google Play Store on the Apple App Store
OR
Press and hold the MIN/MAX button whilst turning the meter on to select °C or °F.
Replace the battery as soon as the low battery indicator appears to avoid false readings.
Refer to the following figure to replace the batteries
G CAUTION
Remove test leads from meter before opening the battery cover or meter case.
General Specifications
Display count : 6,000 counts.
Overrange display : « OL » or « -OL »
Measurement frequency : 3 times per second
Maximum Conductor Size of 42 mm diameter
JAW:
Dimensions (W x H x D) : 62 x 254 x 41 mm
Weight (approx.) : 480 g (including battery)
Low Batteries Indication If battery voltage drops below the operating
voltage, will flash.
Power requirements : AA size battery x 2 (R6, LR6, 15D, 15A)
Battery life : pproximately 200 hours (based on Alkaline
A
batteries without using the backlight).
Environmental Conditions
Indoor Use Only
Pollution degree : 2
Maximum Operating Altitude : 2,000 m (6562 ft)
Operating Temperature & - 10 °C ~ 10 °C,
Relative Humidity : -10 °C ~ 30 °C, ≤80 % RH.
30 °C ~ 40 °C, ≤75 % RH.
40 °C ~ 50 °C, ≤45 % RH.
Storage temperature : -20 to +60 °C, 0 to 80 % RH.
(batteries not fitted)
Vibration : andom Vibration per MIL-PRF-28800F
R
Class 2
Drop Protection : .2 m (4 ft) drop to hardwood on concrete
1
floor
Safety : E N 61010-1, EN 61010-2-032,
EN 61010-2-033 for CAT III 1000 V, CAT IV
600 V, EN 61326-1
Input Impedance : 10 MΩ
Overload Protection : AC/DC 1,000 V
DC Voltage
Range OL Reading Resolution Accuracy
600.0 V 660.0 V 0.1 V
± (0.7% + 2D)
1000 V 1100 V 1V
Input Impedance : 10 MΩ
Overload Protection : AC/DC 1,000 V
AC/DC µA
Range OL Reading Resolution Accuracy
400.0 µA 440.0 µA 0.1 µA
± (1.0% + 3D)
4000 µA 4400 µA 1 µA
Add 10 digits to the accuracy when <5.0 A. Add 0.5% to the accuracy when >1000 A.
Add 1% to the accuracy when >100 Hz.
Frequency Response : (Sine Wave) 45 ~ 400 Hz for ≤1000 A
45 ~ 65 Hz for >1000 A
Overload Protection : AC/DC 1500 A
Frequency
Range OL Reading Resolution Accuracy
100.00 Hz 100.00 Hz 0.01 Hz
1000.0 Hz 1000.0 Hz 0.1 Hz ± (0.3% + 3D)
10.000 kHz 10.000 kHz 0.001 kHz
Inrush Current
Available for ACA and Flexible Current Probe. Trigger level: ≥50d.
Add ± 3% to specified accuracy of each function and each range.
Continuity
Built-in buzzer sounds when measured resistance is less than 20Ω and the sound is off
when measured resistance is more than 200 Ω, between 20 Ω to 200 Ω the buzzer may
be either on or off.
Continuity Indicator : 2.7 kHz Tone Buzzer
Response Time of Buzzer : < 100 ms
Overload Protection : AC/DC 1000 V
Diode
Range OL Reading Resolution Accuracy
1.500 V 1.550 V 0.001 V ± (0.9% + 2D)
Capacitance
Range OL Reading Resolution Accuracy
100.0 µF 110.0 µF 0.1 µF
± (1.9% + 2D)
1000 µF 1100 µF 1 µF
Temperature
Range OL Reading Resolution Accuracy
-40.0 °C – 400.0 °C 440.0 °C 0.1 °C ± (1% + 20D)
-40.0 °F – 752.0 °F 824.0 °F 0.1 °F ± (1% + 36D)
The accuracy does not include the accuracy of the thermocouple probe.
Accuracy specification assumes surrounding temperature stable to ±1 °C.
For surrounding temperature changes of ± 2 °C rated accuracy applies after 2 hours.
Overload Protection : AC/DC 1000 V
Cleaning
Periodically wipe the case with a dry cloth and detergent, do not use abrasives or solvents
WEEE Directive
The crossed out wheeled bin symbol on the instrument and on the batteries is a reminder
not to dispose of them with general waste at the end of their life. Megger is registered in
the UK as a Producer of Electrical and Electronic equipment. The registration No is; WEE/
DJ2235XR.
Users of Megger products in the UK may dispose of them at the end of their useful life by
contacting B2B Compliance at www.b2bcompliance.org.uk or by telephone on 01691
676124.
Users of Megger products in other regions should contact their local Megger office or
distributor.
Battery Disposal
The batteries in this product are classified as Portable Batteries under the Batteries
Directive. Please contact either Megger Ltd, your local Megger office or distributor for
instructions on the safe disposal of these batteries. Megger is registered in the UK as a
producer of batteries. The registration number is BPRN01235.
This meter is warranted to the original purchaser against defects in material and
workmanship for 3 year from the date of purchase.
During this warranty period, the manufacturer will, at its option, replace or repair the
defective unit, subject to verification of the defect or malfunction.
This warranty does not cover fuses, disposable batteries, or damage from abuse, neglect,
accident, unauthorised repair, alteration, contamination, or abnormal conditions of
operation or handling.
Any implied warranties arising out of the sale of this product, including but not limited to
implied warranties of merchantability and fitness for a particular purpose, are limited to
the above. The manufacturer shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any claim or
claims for such damage, expense or economic loss. Some states or countries laws vary, so
the above limitations or exclusions may not apply to you.
Megger Limited
Archcliffe Road
Dover
Kent
CT17 9EN
Visit us at www.TestEquipmentDepot.com
The company reserves the right to change the specification or design without prior notice.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG,
Inc and is used under licence.