0% found this document useful (0 votes)
5 views

Test Report of Stone Compoosite Material

Uploaded by

Lil Tug
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
5 views

Test Report of Stone Compoosite Material

Uploaded by

Lil Tug
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Test Report Number: GZHH00501546

Applicant: FOSHAN GREENZONE CO., LTD Date: Oct 07, 2023


NO.12A, BLOCK 2, YIMEIJIA, NO.4 JIHUA ROAD,
CHANCHENG DISTRICT, FOSHAN, CHINA.

Sample Description:
One (1) submitted samples said to be :
Item Description : Greenzone KUAI Stone Composite Panel
Style/item no. : SS15
Material Name : WPC
Manufacturer Greenzone
Sample Received Date : Jul 18, 2023
Test Period : Jul 18, 2023 to Aug 28, 2023

************************************************************************************************************************************

Tests conducted:
As requested by the applicant, refer to attached page(s) for details.
************************************************************************************************************************************
To be continued

*GZHJ501546*
Page 1 of 11

Intertek Testing Services Shenzhen Limited, Guangzhou Branch Tel +8620 28209114
帿㖕㣔牬餘ꆀ䪮助剪⸉剣ꣳⰖ぀䎛䊜ⴔⰖ぀ intertek.com.cn
intertek.com
111, Huichuang Kongjian, TCL Cultural Industrial Park, No.69, Guangpu Road, Huangpu District,
Guangzhou, Guangdong, China. / Room 401/501/601/801/901/1003, No. 8, East BaoYing Road,
Huangpu District, Guangzhou, China
䎛䊜䋑랕㚅⼓⯕靶銯騟 69 〿 TCL 俒⻊❡⚌㔩宨⴯瑟ꢂ 111 㹔/䎛䊜䋑랕㚅⼓⥂渠⚎騟 8 〿 401 䨻ծ501 䨻ծ
601 䨻ծ801 䨻ծ901 䨻ծ1003 䨻
Test Report Number: GZHH00501546

Conclusion:
Tested sample Test Item Result
Submitted sample Mohs’ Hardness Test See test
- As per the client`s requirement, with reference to EN conducted
101: 1991

Water Absorption See test


- As per the client`s requirement, with reference to ISO conducted
10545-3: 2018

Breaking Strength and Modulus of Rupture See test


- As per the client`s requirement, with reference to ISO conducted
10545-4: 2019

Resistance to Deep Abrasion for Unglazed Tiles See test


- As per the client`s requirement, with reference to ISO conducted
10545-6: 2010

Coefficient of Linear Thermal Expansion See test


- As per the client`s requirement, with reference to ISO conducted
10545-8: 2014

Thermal Shock Resistance See test


- As per the client`s requirement, with reference to ISO conducted
10545-9: 2013

Frost Resistance See test


- As per the client`s requirement, with reference to ISO conducted
10545-12: 1997

Resistance to Chemicals See test


- As per the client`s requirement, with reference to ISO conducted
10545-13: 2016

Resistance to Staining See test


- As per the client`s requirement, with reference to ISO conducted
10545-14: 2015

Reaction to Fire See test


- As per the client`s requirement, with reference to EN conducted
15102: 2019 Clause 4.1 & EN 13501-1: 2018

Release of Formaldehyde See test


- As per the client`s requirement, with reference to EN conducted
15102: 2019 Clause 4.2 & EN 12149: 1997
************************************************************************************************************************************
To be continued

*GZHJ501546*
Page 2 of 11

Intertek Testing Services Shenzhen Limited, Guangzhou Branch Tel +8620 28209114
帿㖕㣔牬餘ꆀ䪮助剪⸉剣ꣳⰖ぀䎛䊜ⴔⰖ぀ intertek.com.cn
intertek.com
111, Huichuang Kongjian, TCL Cultural Industrial Park, No.69, Guangpu Road, Huangpu District,
Guangzhou, Guangdong, China. / Room 401/501/601/801/901/1003, No. 8, East BaoYing Road,
Huangpu District, Guangzhou, China
䎛䊜䋑랕㚅⼓⯕靶銯騟 69 〿 TCL 俒⻊❡⚌㔩宨⴯瑟ꢂ 111 㹔/䎛䊜䋑랕㚅⼓⥂渠⚎騟 8 〿 401 䨻ծ501 䨻ծ
601 䨻ծ801 䨻ծ901 䨻ծ1003 䨻
Test Report Number: GZHH00501546

Conclusion:
Tested sample Test Item Result
Submitted sample Migration of Heavy Metals and Specific Elements See test
- As per the client`s requirement, with reference to EN conducted
15102: 2019 Clause 4.3 & EN 12149: 1997

Release of Vinyl Chloride monomer See test


- As per the client`s requirement, with reference to EN conducted
15102: 2019 Clause 4.4 & EN 12149: 1997

Thermal Resistance See test


- As per the client`s requirement, with reference to EN conducted
15102: 2019 Clause 4.8 & EN 12667:2001

Standard
Tested component(s) of European Standard on Child Use and Care Articles - See test
submitted samples Cutlery and Feeding Utensils - EN 14372:2004 on conducted
phthalate content
************************************************************************************************************************************

Authorized by:
For Intertek Testing Services Shenzhen Ltd.
Guangzhou Branch, Hardlines

Victor T.J. Wang


Assistant General Manager

*GZHJ501546*
Page 3 of 11

Intertek Testing Services Shenzhen Limited, Guangzhou Branch Tel +8620 28209114
帿㖕㣔牬餘ꆀ䪮助剪⸉剣ꣳⰖ぀䎛䊜ⴔⰖ぀ intertek.com.cn
intertek.com
111, Huichuang Kongjian, TCL Cultural Industrial Park, No.69, Guangpu Road, Huangpu District,
Guangzhou, Guangdong, China. / Room 401/501/601/801/901/1003, No. 8, East BaoYing Road,
Huangpu District, Guangzhou, China
䎛䊜䋑랕㚅⼓⯕靶銯騟 69 〿 TCL 俒⻊❡⚌㔩宨⴯瑟ꢂ 111 㹔/䎛䊜䋑랕㚅⼓⥂渠⚎騟 8 〿 401 䨻ծ501 䨻ծ
601 䨻ծ801 䨻ծ901 䨻ծ1003 䨻
Test Report Number: GZHH00501546

Tests Conducted

1 Mohs’ Hardness Test

As per the client's requirement, with reference to EN 101:1991, the submitted sample was subjected to the
following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test conditions:
Lab environment condition: 23±2℃, 50±5%RH

Test result:
Test item Test result
Mohs’ hardness test 2

2 Water Absorption

As per the client's requirement, with reference to ISO 10545-3: 2018, the submitted sample was subjected
to the following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test conditions:
Dry condition: Dry at 110℃ until constant mass→ Cool to room temperature
Impregnation condition: 10kPa, 30min → immersed in water, 15min.

Test result:
Specimens No. 1 2 3 4 5
Water Absorption, (%) 18.8 21.4 20.2 21.8 25.0

*GZHJ501546*
Page 4 of 11

Intertek Testing Services Shenzhen Limited, Guangzhou Branch Tel +8620 28209114
帿㖕㣔牬餘ꆀ䪮助剪⸉剣ꣳⰖ぀䎛䊜ⴔⰖ぀ intertek.com.cn
intertek.com
111, Huichuang Kongjian, TCL Cultural Industrial Park, No.69, Guangpu Road, Huangpu District,
Guangzhou, Guangdong, China. / Room 401/501/601/801/901/1003, No. 8, East BaoYing Road,
Huangpu District, Guangzhou, China
䎛䊜䋑랕㚅⼓⯕靶銯騟 69 〿 TCL 俒⻊❡⚌㔩宨⴯瑟ꢂ 111 㹔/䎛䊜䋑랕㚅⼓⥂渠⚎騟 8 〿 401 䨻ծ501 䨻ծ
601 䨻ծ801 䨻ծ901 䨻ծ1003 䨻
Test Report Number: GZHH00501546

Tests Conducted

3 Breaking Strength and Modulus of Rupture

As per the client's requirement, with reference to ISO 10545-4:2019, the submitted sample was subjected to
the following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test conditions:
Specimen: 300mm×300mm×4.53mm
Conditioning: 110℃, 24h→ Cool down to room temperature
2
Loading rate: 1N/mm /s

Test result:
Specimens No. 1 2 3 4 5 6 7
Breaking strength, (N) 70.6 72.6 63.8 76.6 70.5 60.9 75.8
Modulus of Rupture,
2 5.16 5.31 4.67 5.60 5.15 4.45 5.54
(N/mm )

4 Resistance to Deep Abrasion for Unglazed Tiles

As per the client's requirement, with reference to ISO 10545-6:2010, the submitted sample was subjected to
the following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test conditions:
Specimen: 150mm×100mm×4.53mm, 5pcs. Cut from the whole tiles.

Test result:
Specimens No. 1 2 3 4 5
Chord length, (mm) 31.0 30.5 31.5 30.5 31.0
3
Removed volume, (mm ) 250 238 262 238 250
3
Mean value, (mm ) 248

*GZHJ501546*
Page 5 of 11

Intertek Testing Services Shenzhen Limited, Guangzhou Branch Tel +8620 28209114
帿㖕㣔牬餘ꆀ䪮助剪⸉剣ꣳⰖ぀䎛䊜ⴔⰖ぀ intertek.com.cn
intertek.com
111, Huichuang Kongjian, TCL Cultural Industrial Park, No.69, Guangpu Road, Huangpu District,
Guangzhou, Guangdong, China. / Room 401/501/601/801/901/1003, No. 8, East BaoYing Road,
Huangpu District, Guangzhou, China
䎛䊜䋑랕㚅⼓⯕靶銯騟 69 〿 TCL 俒⻊❡⚌㔩宨⴯瑟ꢂ 111 㹔/䎛䊜䋑랕㚅⼓⥂渠⚎騟 8 〿 401 䨻ծ501 䨻ծ
601 䨻ծ801 䨻ծ901 䨻ծ1003 䨻
Test Report Number: GZHH00501546

Tests Conducted

5 Coefficient of Linear Thermal Expansion

As per the client's requirement, with reference to ISO 10545-8:2014, the submitted sample was subjected to
the following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test conditions:
Heating rate: 5°C/min
Temperature range:30°C ~ 100°C

Test result:
Test Item Test Result
-6
α1: 71.5×10 /°C
-6 -6
Coefficient of linear thermal expansion, (×10 /°C) α2: 76.2×10 /°C
-6
Average: 73.8×10 /°C

6 Thermal Shock Resistance

As per the client's requirement, with reference to ISO 10545-9:2013, the submitted sample was subjected to
the following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test conditions:
10 times of thermal shock cycles in temperature of 15°C~145°C

Test result:
Specimens No. 1 2 3 4 5
Description of No visible No visible No visible No visible No visible
damage defects defects defects defects defects

*GZHJ501546*
Page 6 of 11

Intertek Testing Services Shenzhen Limited, Guangzhou Branch Tel +8620 28209114
帿㖕㣔牬餘ꆀ䪮助剪⸉剣ꣳⰖ぀䎛䊜ⴔⰖ぀ intertek.com.cn
intertek.com
111, Huichuang Kongjian, TCL Cultural Industrial Park, No.69, Guangpu Road, Huangpu District,
Guangzhou, Guangdong, China. / Room 401/501/601/801/901/1003, No. 8, East BaoYing Road,
Huangpu District, Guangzhou, China
䎛䊜䋑랕㚅⼓⯕靶銯騟 69 〿 TCL 俒⻊❡⚌㔩宨⴯瑟ꢂ 111 㹔/䎛䊜䋑랕㚅⼓⥂渠⚎騟 8 〿 401 䨻ծ501 䨻ծ
601 䨻ծ801 䨻ծ901 䨻ծ1003 䨻
Test Report Number: GZHH00501546

Tests Conducted

7 Frost Resistance

As per the client's requirement, with reference to ISO 10545-12:1997, the submitted sample was subjected
to the following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test conditions:
100 times of freeze-thaw cycles in temperature of 5°C~-5°C

Test result:
Specimens
1 2 3 4 5 6 7 8 9 10
No.
Surface of No No No No No No No No No No
specimens defect defect defect defect defect defect defect defect defect defect

8 Resistance to Chemicals

As per the client's requirement, with reference to ISO 10545-13:2016, the submitted sample was subjected
to the following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test result:
Test Item Test Result
Ammonium chloride solution (100g/L) Class A
Sodium hypochlorite solution (20mg/L) Class A
Hydrochloric acid solution 3 % (V/V) Class LA
Citric acid solution (100g/L) Class LA
Potassium hydroxide solution (30g/L) Class LA

Note:
1.Class A and Class LA: No visible effect.
2.Class is evaluated according to NF EN ISO 10545-13:2016, with Class A and Class LA as the best and
Class C and Class LC as the worst.

*GZHJ501546*
Page 7 of 11

Intertek Testing Services Shenzhen Limited, Guangzhou Branch Tel +8620 28209114
帿㖕㣔牬餘ꆀ䪮助剪⸉剣ꣳⰖ぀䎛䊜ⴔⰖ぀ intertek.com.cn
intertek.com
111, Huichuang Kongjian, TCL Cultural Industrial Park, No.69, Guangpu Road, Huangpu District,
Guangzhou, Guangdong, China. / Room 401/501/601/801/901/1003, No. 8, East BaoYing Road,
Huangpu District, Guangzhou, China
䎛䊜䋑랕㚅⼓⯕靶銯騟 69 〿 TCL 俒⻊❡⚌㔩宨⴯瑟ꢂ 111 㹔/䎛䊜䋑랕㚅⼓⥂渠⚎騟 8 〿 401 䨻ծ501 䨻ծ
601 䨻ծ801 䨻ծ901 䨻ծ1003 䨻
Test Report Number: GZHH00501546

Tests Conducted

9 Resistance to Staining

As per the client's requirement, with reference to ISO 10545-14:2015, the submitted sample was subjected
to the following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test result:
Test Item Test Result
Iodine: 13 g/L solution in alcohol Class 5
Green staining agent Class 5
Olive oil Class 5

Note: Class 5 corresponds to the greatest ease of removing the particular stain: class 1 corresponds to the
impossibility of removing the particular stain with any of the test procedures and / or to irreversible damage
of the proper surface.

10 Reaction to Fire

As per the client's requirement, with reference to EN 15102: 2019 Clause 4.1 & EN 13501-1: 2018, the
submitted sample was subjected to the following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test result:
Test Item Test Result
Class F
Reaction to fire
(Declared by applicant without testing)

*GZHJ501546*
Page 8 of 11

Intertek Testing Services Shenzhen Limited, Guangzhou Branch Tel +8620 28209114
帿㖕㣔牬餘ꆀ䪮助剪⸉剣ꣳⰖ぀䎛䊜ⴔⰖ぀ intertek.com.cn
intertek.com
111, Huichuang Kongjian, TCL Cultural Industrial Park, No.69, Guangpu Road, Huangpu District,
Guangzhou, Guangdong, China. / Room 401/501/601/801/901/1003, No. 8, East BaoYing Road,
Huangpu District, Guangzhou, China
䎛䊜䋑랕㚅⼓⯕靶銯騟 69 〿 TCL 俒⻊❡⚌㔩宨⴯瑟ꢂ 111 㹔/䎛䊜䋑랕㚅⼓⥂渠⚎騟 8 〿 401 䨻ծ501 䨻ծ
601 䨻ծ801 䨻ծ901 䨻ծ1003 䨻
Test Report Number: GZHH00501546

Tests Conducted

11 Release of Formaldehyde

As per the client's requirement, with reference to EN 15102: 2019 Clause 4.2 & EN 12149: 1997, the
submitted sample was subjected to the following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test result:
Test Item MDL (mg/kg) Test Result (mg/kg)
Release of formaldehyde 0.1 0.7

Remark: ND=Not Detected; MDL=Method Detection Limits; 1 mg/kg=0.0001%.

12 Migration of Heavy Metals and Specific Elements

As per the client's requirement, with reference to EN 15102: 2019 Clause 4.3 & EN 12149: 1997, the
submitted sample was subjected to the following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test result:
Test Item MDL (mg/kg) Test Result (mg/kg)
Antimony (Sb) 5 ND
Arsenic (As) 5 ND
Barium (Ba) 5 ND
Cadmium (Cd) 2 ND
Chromium (Cr) 2 ND
Lead (Pb) 2 ND
Mercury (Hg) 2 ND
Selenium (Se) 5 ND

Remark:
1. ND=Not Detected; MDL=Method Detection Limits; 1 mg/kg=0.0001%.
2. The results shown are the total weight of the sample.

*GZHJ501546*
Page 9 of 11

Intertek Testing Services Shenzhen Limited, Guangzhou Branch Tel +8620 28209114
帿㖕㣔牬餘ꆀ䪮助剪⸉剣ꣳⰖ぀䎛䊜ⴔⰖ぀ intertek.com.cn
intertek.com
111, Huichuang Kongjian, TCL Cultural Industrial Park, No.69, Guangpu Road, Huangpu District,
Guangzhou, Guangdong, China. / Room 401/501/601/801/901/1003, No. 8, East BaoYing Road,
Huangpu District, Guangzhou, China
䎛䊜䋑랕㚅⼓⯕靶銯騟 69 〿 TCL 俒⻊❡⚌㔩宨⴯瑟ꢂ 111 㹔/䎛䊜䋑랕㚅⼓⥂渠⚎騟 8 〿 401 䨻ծ501 䨻ծ
601 䨻ծ801 䨻ծ901 䨻ծ1003 䨻
Test Report Number: GZHH00501546

Tests Conducted

13 Elements Release of Vinyl Chloride monomer

As per the client's requirement, with reference to EN 15102: 2019 Clause 4.4 & EN 12149: 1997, the
submitted sample was subjected to the following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test result:
Test Item MDL (mg/kg) Test Result (mg/kg)
Vinyl chloride monomer 50 ND

Remark: ND=Not Detected; MDL=Method Detection Limits; 1 mg/kg=0.0001%.

14 Thermal Resistance

As per the client's requirement, with reference to EN 15102: 2019 Clause 4.8 & EN 12667:2001, the
submitted sample was subjected to the following tests.

Sample description: Stone composite pane

Initial inspection: No any damage was found

Test result:
2
Temperature difference, (℃) Average temperature, (℃) Thermal resistance, (m ·K/W)
10 20 0.04661

*GZHJ501546*
Page 10 of 11

Intertek Testing Services Shenzhen Limited, Guangzhou Branch Tel +8620 28209114
帿㖕㣔牬餘ꆀ䪮助剪⸉剣ꣳⰖ぀䎛䊜ⴔⰖ぀ intertek.com.cn
intertek.com
111, Huichuang Kongjian, TCL Cultural Industrial Park, No.69, Guangpu Road, Huangpu District,
Guangzhou, Guangdong, China. / Room 401/501/601/801/901/1003, No. 8, East BaoYing Road,
Huangpu District, Guangzhou, China
䎛䊜䋑랕㚅⼓⯕靶銯騟 69 〿 TCL 俒⻊❡⚌㔩宨⴯瑟ꢂ 111 㹔/䎛䊜䋑랕㚅⼓⥂渠⚎騟 8 〿 401 䨻ծ501 䨻ծ
601 䨻ծ801 䨻ծ901 䨻ծ1003 䨻
Test Report Number: GZHH00501546

Tests Conducted

15 Phthalate Content

As per European Standard on Child Use and Care Articles - Cutlery and Feeding Utensils - EN
14372:2004, by Gas Chromatographic-Mass Spectrometric (GC-MS) analysis.

Component (1)
Result (%)
Dibutyl phthalate (DBP) <0.005
Di-(2-ethyl hexyl) phthalate (DEHP) 0.010
Di-(iso-nonyl) phthalate (DINP) <0.005
Benzyl butyl phthalate (BBP) <0.005
Di-(n-octyl) phthalate (DNOP) <0.005
Di-(iso-decyl) phthalate (DIDP) <0.005

Sum of six phthalates 0.010

Limit 0.1%

Tested Component: (1) White/beige stone composite pane.


************************************************************************************************************************************
End of report

The statements of conformity reported have considered the decision rule agreed, namely that Intertek have taken account of measurement uncertainty as
calculated by Intertek, and applied according to ILAC-G8/09:2019 (Non-binary acceptance based on guard band w = U) except designation from the customer,
regulation or test specification. This decision rule only applies to the numeric test results.
The sample(s) and sample information hereto are provided by the client who shall be solely responsible for the authenticity and integrity thereof. The results shown
in this report relate only to the sample(s) tested. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of
care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained
in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with
respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not
accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross
negligence or wilful misconduct. This report shall not be reproduced unless with prior written approval from Intertek Testing Services Shenzhen Limited, Guangzhou
Branch. The testing data and result issued by this report are just for scientific research, teaching, internal quality control, product research and development etc. on
reference only in the territory of the People’s Republic of China.

*GZHJ501546*
Page 11 of 11

Intertek Testing Services Shenzhen Limited, Guangzhou Branch Tel +8620 28209114
帿㖕㣔牬餘ꆀ䪮助剪⸉剣ꣳⰖ぀䎛䊜ⴔⰖ぀ intertek.com.cn
intertek.com
111, Huichuang Kongjian, TCL Cultural Industrial Park, No.69, Guangpu Road, Huangpu District,
Guangzhou, Guangdong, China. / Room 401/501/601/801/901/1003, No. 8, East BaoYing Road,
Huangpu District, Guangzhou, China
䎛䊜䋑랕㚅⼓⯕靶銯騟 69 〿 TCL 俒⻊❡⚌㔩宨⴯瑟ꢂ 111 㹔/䎛䊜䋑랕㚅⼓⥂渠⚎騟 8 〿 401 䨻ծ501 䨻ծ
601 䨻ծ801 䨻ծ901 䨻ծ1003 䨻

You might also like