PI Release 2.2
PI Release 2.2
, CH-Basle
Product information
Information produit
englisch (GB) - e / DoNo.: D100005167 Release date: 16.02.2007
Version 2.2 of novaPro Open is now on sale and can be ordered from stock at
SBA with immediate effect.
LIST OF CONTENTS
1. Ordering information ........................................................................................................... 3
2. Contents of novaPro Open Suite 2.2 .................................................................................. 3
2.1 CD No 1: novaPro Open Suite 2.2 ......................................................................................... 3
2.2 CD No 2:................................................................................................................................ 4
2.3 Cluster ................................................................................................................................... 4
3. New features of novaPro Open Suite 2.2............................................................................ 5
3.1 Calling up the multiple tag list in novaPro Open Studio .......................................................... 5
3.2 AAM user time table in the web.............................................................................................. 6
3.3 User administration shift planner in the web........................................................................... 6
3.4 Alarm definition: action on alarm ............................................................................................ 7
3.5 The 'Inhibit alarm' page in the national language.................................................................... 7
3.6 Alarm objects in pictures support alarm filters ........................................................................ 7
3.7 Alarm template....................................................................................................................... 8
3.8 Context .................................................................................................................................. 8
3.9 Support of ActiveX elements in pictures................................................................................. 9
3.10 BACnet generation – Object Generator................................................................................ 11
3.11 Object Generator Wizard ..................................................................................................... 13
3.12 Tag and Alarm Editor ........................................................................................................... 15
4. List of fixes......................................................................................................................... 16
5. System requirements......................................................................................................... 17
pi_07-186e_SCP / D-ID: 443004 R.: 04 / V.: 01 1 / 20
5.1 Hardware ............................................................................................................................. 17
5.2 Software .............................................................................................................................. 17
6. Known problems................................................................................................................ 18
7. Installation.......................................................................................................................... 18
7.1 Pre-conditions...................................................................................................................... 18
7.2 Installing novaPro Open Suite 2.2 on a PC ......................................................................... 19
7.3 Installing novaPro Open Suite 2.2 in a network.................................................................... 19
8. Updating project data ........................................................................................................ 20
9. Documentation................................................................................................................... 20
10. Training .............................................................................................................................. 20
11. FAQs ................................................................................................................................... 20
Please note:
Use version upgrade
YZP 420 F003 to upgrade from V2.1 to V2.2
YZP 420 F004 to upgrade from V1.x or V2.0 to V2.2
Advantages:
o Uniform appearance when working with lists in a novaPro Open application.
o Calls are made via dynamic tag filters. Thus it is possible to install one tag filter for
each plant or section. Selecting the desired filter will exclusively display data points
from the desired plant or section.
It allows convenient operation of the novaPro Open application via plant-specific data
point lists.
o You now have direct access to all the parameters for tag definition from the tag list
with on-line data on call from the novaPro Open Studio.
o Tag address and sampling rate
o Activating or deactivating tag reading.
o Forced reading of every tag displayed in the list.
Advantages:
o Remote configuration and operation of the user time table from any PC in the network
using Internet Explorer.
o The user time table can be called up from within a novaPro Open picture via a trigger
object with the URL: http://PCname/docs/UsersTimeTable.html
Advantages:
o Remote configuration and operation of the user time table from any PC in the network
using Internet Explorer.
o The user time table can be called up from within a novaPro Open picture via a trigger
object with the URL: http://PCname/docs/ShiftManagement.html
Advantages:
o Easy visualisation of batch
alarms in pictures.
o You can simply copy alarm
filters (AFM.XML) from one
application (project) to
another project.
Fig. 8: Alarm filter selection with context Fig. 9: Calling up an event window via a trigger object
from within a picture with context details.
3.8 Context
The tag context for pictures and trends was introduced with novaPro Open 2.1. The tag context
enables the efficient generation of group pictures.
novaPro Open 2.2 also allows the use of context in event windows and alarm objects via alarm filters,
and in the tag list (Tag Lock) and analysis via tag filter.
JavaAPIs are available for Java programmers:
o changeLayoutContext(context)
o ChangeContext(window, context)
o loadPicture(window, image, context)
Advantages:
o Allows you to call up a specific alarm list for each room in group pictures (hotel rooms). You
only need to generate one alarm list.
ActiveX elements available in novaPro Open must be listed in the file ActiveX.ini.
Enter the video file to be played by default when the picture is opened under 'Default file'. You can
also use a novaPro Open tag to dynamically send the video file to Windows Media Player.
To do so, create a dummy tag of the type 'String'. You can now assign the name of the video file to
the tag.
Application example:
Allocate the file to be played as an instruction for the user in the event of an alarm to the 'Video' tag.
Enter the website to be opened by default when the picture is loaded under 'Default URL'. You can
also use a novaPro Open tag to dynamically send the URL to the Web Explorer.
To do so, create a dummy tag of the type 'String'. You can now assign the URL to the tag.
Fig. 14: Example of a novaPro Open picture with embedded Media Player and Web Explorer
Fig. 18: Rule for creating alarms Fig. 19: Preview of created alarms
Variables permitted in dialogues Illus. 16: Rules for naming tags and Fig. 18: Rule for creating
alarms:
%DevInst%
%DevName%
%ObjType%
%ObjTypeName%
%ObjInst%
%ObjName%
%PropId%
%PropName%
%Description%
%KeyName%
%Counter%
Enter '%' – this will display a selection list of the variables %EventTypeName%
available. %EventStateName%
Fig. 20: Variables permitted in dialogues, Fig. 16: Rules for naming tags, and Fig. 18: Rules for creating
alarms
An EDE file can be created directly from CASE FBD or CASE Engine data for projects in EYK220,
EYK230 or EYK300.
The EDE file in BACnet projects serves the exchange of data between automation level and
management level. The EDE file permits the parameterisation of the management level without
having to create an on-line connection to the automation stations (see also 3.10)
Advantages:
o Import direct from CASE FBD or CASE Engine project data without previously exporting the
date in an intermediate format.
o Generation of the novaPro Open tags for EY3600 novaNet
o Generation of the novaPro Open alarms for EY3600 novaNet
o Generation of the EDE file for EY3600 BACnet
o Automatic generation of tag filters based on the house address structure. Tag filters are used
in the 'Tag Table', 'Multiple Tag List' to display a plant address list. 3.1 Calling up the multiple
tag list in novaPro Open Studio
o Automatic creation of novaPro Open text tables (*.tbl), for instance to display comparators as
text. A *.tbl is created automatically for multi-stage switching commands based on the
definitions in CASE.
o Automatic creation of alarm filters (see also 3.6 Alarm objects in pictures support alarm filters,
3.7 Alarm template)
o View (Preview) of imported data points and alarms prior to definitive adoption
Data generated by the Object Generator Wizard is stored under UCVT_Data in the project directory.
Example when using the Project Template: D:\EY3600\Hotel Bellevue\Private_Data\UCVT_Data
Fig. 23: Import of EY3600 novaNet data points from CASE FBD or CASE Engine and preview of
generated alarms
Fig. 24: Import of EY3600 novaNet data points from CASE FBD or CASE Engine and preview of the
BACnet EDE file
Advantages:
o Efficient modification of properties of a large number of tags or alarms.
o The 'Export, process with Excel and re-import' method used to date no longer applies. Data is
modified directly in the novaPro Open database.
o Reduction of work steps required to modify tag and alarm properties.
Ö More efficient, i.e. faster and safer method of working.
4. List of fixes
BACnet:
2006/1334 nPO repeats Read-Range all the time without end.
2006/1271 BCC: No way to cancel when reading object.
2006/1249 BCN is blocked, if you poll non available device.
2006/1218 Event_Notification are ignored by nPO.
2006/1217 No 'Remove_List_elements' after shut-down from nPO.
2006/1216 BCC: property Device 'active_cov_subscritions'
2006/1136 CHANGE_OF_BITSTRING event type algorithms
2006/1099 Trending & name-based address format
2006/1029 The WebScheduler does not check the Bacnet error Message.
EY2400:
ECR 3367: S24 driver is modified to run on Master/Backup architecture.
OPC:
ECR 2569: When you start the Wizcon client OPC with a wrong server name in COM
start-up takes a long time.
ECR 3297: On reconnection with the DEF OPC Server, our OPC client is not notified
anymore and values are frozen.
Applicom:
ECR 3314: Dual sampling on Master/Backup application with Applicom driver.
General:
5. System requirements
Before you install the application, verify that you have the following:-
5.1 Hardware
Processor: Pentium III 800 MHz (recommended 1 GHz and up)
RAM: 256 MByte RAM (recommended 512 MB)
Hard disk: at least 1.8 GB (9 GB recommended, depending on size of
system)
Monitor adaptor 32 MB
Monitor resolution 800x600 or higher
Display: VGA, SVGA, or any graphic adaptor that supports the
operation system desktop. Colour depth should be at least
256 colours.
CD reader: for the installation
Ports: 1 mouse
2 serial RS-232
1 network connection
1 USB port for dongle
5.2 Software
Operating system: Microsoft's Windows NT 4.0 SP6a, Windows 2000 SP4,
Windows XP SP2 or Windows 2003 Server
Correctly configured TCP/IP: IP address can be fixed or provided by a DHCP server,
except for HotBackup stations and web server which should
have a fixed IP address set manually.
6. Known problems
• Before installing the current version of the product, always uninstall the currently installed
version from your computer.
• In the rare event that you cannot uninstall novaPro Open from the Control Panel 'Add/Remove
Programs', uninstall it with help of the file Setup.exe from the location where you performed
the installation (i.e. from the CD or a local folder).
• There are a number of online Help subjects that appear in English only.
• Advanced Alarm Management: Backup User option does not function.
• Image: when a metafile .EMF or .WMF is imported to the Image module text conversion is not
supported during the file’s conversion.
• In the rare event that you cannot launch novaScheduler, you must give write access control to
the Internet Guest Account 'IUSR_<<computer name>>' in the novaPro Open application
folder where the file WebScheduler.mdb is located
7. Installation
7.1 Pre-conditions
• Before you start the installation of novaPro Open, ensure that the operating system, the
internet information server (IIS) and Microsoft’s Internet Explorer have been installed.
• Backup your project data
• Backup the INI-files from AAM as followed:
e.g. Email.ini
ermes.ini
Fax.ini
Jericho.ini
Pager.ini
tap.ini
These files can be found in:
C:\Program\Sauter\EY3600\novaPro_Open Suite\novaPro Open\Bin
• Deinstall any older versions of novaPro Open before starting the installation, and save your
project data.
The file 'Jericho.cfg' can be found in the folder C:\Program Files\Sauter\EY3600\novaPro Open\Bin .
The file is empty by default.
Add the path of your project data:
e. g.: D:\EY3600\SkyTower\Private_Data
From now on, all configuration files with extension *.ini are saved in your project folder.
9. Documentation
novaPro Open Suite 2.1 has an extensive, integrated, online help function. In addition, the user’s
manuals I + II 2.0 are provided on the CD as PDF files.
BACnet PICS and BIBBS have all been updated and are available on Sauter-Intra for downloading.
10. Training
Training courses on novaPro Open are held regularly at SBA. For the exact dates, please consult
Sauter's training schedule.
11. FAQs
Answers and possible solutions to frequently-asked questions can be found in the Sauter Intr@net at:
https://www.sauter-intra.ch/download/documentation/faq_36novaproopen_001.pdf.
Peter Schoenenberger
Product Manager