VALUE LINE distribution amplifiers Rotary switch

VX 26 / 29 4032 Distribution amplifier


- CATV amplifier high output level
- Protection class IP 54
- all setting via rotary switches (stepwise)
- Return path passive/ active
- Lightning protection RF connectors /Power supply

Down-Stream
Frequency range 47/85-862 MHz
Gain 40 dB
Output level CENELEC flat 111 dBµV
42 ch 6 dB slope 114 dBµV
CSO, CTB ≥ 65 dB, ≥ 60 dB
Noise figure ≤ 6 dB
Input
Attenuator rotary switch 16 steps 0-15 dB
per 1 dB
Equalizer rotary switch 16 steps 0-22.5 dB
per 1.5 dB
Interstage attenuation Jumper 0/5 dB
Interstage slope Jumper 0/6 dB
Cable simulation Jumper 0/5 dB
Number of outputs 2
Test point input output -20 dB
Splitter 4 dB
Up-Stream
Frequency range 5-65 MHz
Gain 32 dB
Noise figure ≤ 6 dB
Output level 2nd order typ. 109 dBµV
3rd order typ. 115 dBµV
Max load 1 TS 140 120 dBµV
Attenuator Rotary switch 16 steps 0-15 dB
per 1 dB
Attenuator Jumper 0/5 dB
Equalizer Jumper 0/3/6/9 dB
General data
Operating voltage VX 26... 180-265 VAC /
50,60 Hz
VX 29... 27-65 VAC /
50, 60 Hz
Power supply typ. 19 W
Connectors VX 26... F
VX 29... PG 11
Remote feed voltage Input <7 A
Output 3A
Operation indicator LEG green
Operating temperature -20°C...+55°C
Storage temperature -25°C...+75°C
EMC CE, Class A