04 · LEVEL DETECTING AND MEASUREMENT

HIGH LEVEL AND OVERFILL ALARM SYSTEM


ELECTRONIC CABINET

ITDAC-14B (n) ITDAC-14B (n)


- overfill - high Red flashing light
1
ITDAC-14B

1
ITDAC-14B
(overfill)
2 2 Ex-Proof CWB-ATEX
3 3
(EEx de IIC T6)
4 4
5 5
6 6
7 7
8 8

ALARM HOLD ALARM HOLD

POWER FAILURE POWER FAILURE


POWER POWER

220V,AC Rectifier Relay unit


unit-overfill (overfill)
Rectifier Relay unit
unit-high (high) AIR HORN
IS relay

IS relay

Amber flashing light,


pulsed (high)
Ex-Proof CWB-ATEX
NON-HAZARDOUS AREA (EEx de IIC T6)
HAZARDOUS AREA
magnetic level
switches
ITHLA

High level and overfill alarm system consists of our standard products:

magnetic level switches type ITHLA-1 (single point alarm) and/or ITHLA-2 (double point alarm)
electronic cabinet with alarm units type ITDAC-14B and intrinsic safety isolators
output light and signalling devices
completly separate high and overfill in the same cabinet

Magnetic level switches connection cables are fully controlled (short circuit, line break, resistance).

System is designed for use on board all types of liquid cargo ships. It is tailor made, following specific
requirements and meets requirements of all major classification societies

COMPONENTS TECHNICAL CHARACTERISTICS AND DIMENSIONS


72

ITDAC-14B
ITDAC 14B ALARM UNIT
1
2
3
Microprocessor controlled
4 Can control up to eight alarm points
5 For more than eight points, more units can be used, with
144

6
common external control buttons and power failure battery
7
8
Due to analogue inputs, ITHLA-x line condition
ALARM HOLD
can be fully controlled
POWER FAILURE
Type approved by Lloyd's, BV, DNV, RINA, GL and Croatian register of shipping
POWER

Depth is 175 mm

ENGINEERING FOR ELECTRONIC EQUIPMENT AND SYSTEMS


MAGNETIC LEVEL SWITCHES

18
Ø
TECHNICAL CHARACTERISTICS
45
Type ITHLA-2 (double point) °

Type ITHLA-1 (single point) Ø180


Specially designed for mounting on open deck, Ø220
robust construction

40
AISI 316L stainless steel construction with flange

Dimensions A, Z1, Z2 and B depends on tank height.


DN100, NP16

15
78
Can be tested from outside of tank
A float with built-in magnet is moved with liquid
level and activates reed switch fitted inside the stem
When high level or overfill alarm is required, single
point magnetic level switch ITHLA-1 is used. When

Z1
both (high level and overfill) alarms are required,
double point magnetic level switch ITHLA-2 should
be used.

Z2
Can be installed in dangerous area and connected

A
B
X
via intrinsically safe isolator situated in non- Switching
point
hazardous area. (According to explosion protection
standards, the equipment is regarded as a "simple
apparatus" due to the fact that it contains only
passive elements such as reed switch and resistors.)
Operating temperature: -25°C up to +90°C Switching
X

Working pressure: up to 4bar for wetting part point


Connection head protection: IP56 52
Ø88x2

EX PROOF FLASHING LIGHT


CWB-ATEX
TECHNICAL CHARACTERISTICS
Explosion protection EEx de IIC T6
Power supply 230V,AC
260

280

Consumption 80mA Ø70


340

Flashing power 5J
Primary fuse 0.20AT
Protection IP-66
Weight approx. 1.5 kg
Colours: red, amber, blue, green
M20x1.5,
35

6-13mm
Ø7
35
10

50

AIR SIREN M75/660

TECHNICAL CHARACTERISTICS 256


222
Frequency 660Hz
Sound pressure level
155

134-137dB/1m
Compressed air 4-10bar
Valve solenoid power supply
138

24V,DC or 220V,AC
Weight 0.38 kg 9
240

Air horn protection IP 66


Valve and Filter protection IP 65,
65

mounted outside of dangerous area


25

40
fixing
All dimensions are in mm. valve
filter

Ljubljanska cesta 7, HR-51000 Rijeka / Croatia / tel. ++385 51 274 536 / fax 712 122 / [email protected] / www.inelteh.hr
04 · LEVEL DETECTING AND MEASUREMENT

MAGNETIC LEVEL MEASURAMENTS ITMLM


MAGNETIC LEVEL MEASURAMENTS...
Continuous level measurament
Accuracy within 15 mm
Measuring range up to 2 meters (more on special
request only)
Top or side mounting
Material used (stainless steel AISI 316L) makes it suitable
for use in various liquids

Connection head
and signal converter Output
Ship's 4-20mA PRINCIPLE OF OPERATION
connection

Stem Resistors network and reed switches are incorporated in


the stem. The float with built-in magnet moves with liquid
level and activates reed switches. Resistor network
Float
changes value due to operation of reed switches. Over
signal converter, resistance is converted to analogue signal
Stopper
of 4-20mA. Signal converter is inside of the connection
head but can be also delivered in separate box.

ITMLM-01-92 90

TECHNICAL CHARACTERISTICS
82

Connection:
4-20mA Connection head protection:
1+ + 24V=
IP-65 with cable gland PG-16
2- Flange type 92x92 Wetside material AISI 316L
25 12

(AISI 316L)
Flange: Standard 92x92
Maximum stainless steel AISI 316L
Counterflange level measurement
Temperature range: up to 80OC
Measuring range

SB5992
Floating element Ø50x48, floatness 0.55
up to 2m

Ø68 min Top mounting


4 x M12
Signal converter inside of connection
head
Minimum Resolution within 15mm
48

level measurement
Output 4-20mA
45

Should be fixed
Ø13 for length of the stem
Ø50 more than 350mm

ITMLM-01-G2" 90
102

TECHNICAL CHARACTERISTICS
Connection head protection:
IP-65 with cable gland PG-16
27

G2"
Wetside material AISI 316L
Ship's connection G2"
25

Maximum
level measurement Temperature range up to 80OC
Connection:
Measuring range

Floating element Ø50x48, floatness 0.55


up to 2m

4-20mA Top mounting


1+
2-
+ 24V= Signal converter inside of connection
head
Minimum Resolution within 15mm
48

level measurement Output 4-20mA


45

Should be fixed
Ø13 for length of the stem
Ø50 more than 350mm

ENGINEERING FOR ELECTRONIC EQUIPMENT AND SYSTEMS


ITMLM-02A-00
Separate connection box
with signal converter
M24 x 1.5

13
Float's
resistors network Float
UPPER 27
brown position TECHNICAL CHARACTERISTICS

27
blue
yellow-green Fixing
Float
or white
LOWER holes Submersible version, IP-68 without
position Ø4.5
connection box

25

8
Maximum
Material AISI 316L
signal converter
PG-13.5 level
ITMLA-03

Temperature range up to 80OC (120 C


brown 3 measurement O
1+ +

Measuring range
blue 4
80
52

yellow- 2- - on special request)


green 5

up to 2m
PG-7 or white
Floating element Ø50x48, floatness 0.55
PTFE, teflon cable 3, 5, 7m or more
113 can be ordered
125 Minimum Top mounting
level

48
+ measurement Signal converter is delivered separately
24V=
Resolution within 15mm

45
4-20mA
Should be
Output 4-20mA
Ø13 fixed for
length of
Ø50
57

the stem
more than
350mm

ITMLM-02-92 Ø58

Separate connection box


with signal converter
75

Float's
resistors network 20
Float Flange
UPPER
25 12

brown position
type 92x92 TECHNICAL CHARACTERISTICS
blue (AISI 316L)
yellow-green Fixing
Float Maximum
or white
LOWER holes Submersible version, IP-68
position Ø4.5 level
measurement PTFE, teflon cable 3, 5, 7m or more
Measuring range

can be ordered
signal converter

PG-13.5
ITMLA-03

up to 2m

brown 3
blue 4 1+ +
Connection protected with IP-68 box
80
52

yellow- 2- - (AISI 316L stainless steel)


PG-7 green 5
or white
Material AISI 316L
Minimum Temperature range up to 80OC (120OC
113 level on special request)
48

125 measurement
Floating element Ø50x48, floatness 0.55
45

+ Top mounting
24V= Should be
4-20mA Signal converter is delivered separately
Ø13 fixed for
Counterflange length of Resolution within 15mm
SB5992 Ø50 the stem Output 4-20mA
more than
350mm
57

Ø68 min
4 x M12

ITMLM-03-92 82 12
Flange type 92x92
(AISI 316L)
100
90

TECHNICAL CHARACTERISTICS
Connection head protection:
85

Connection: IP-65 with cable gland PG-16


4-20mA Wetside material AISI 316L
Maximum
1+ + 24V= level measurement Flange: Standard 92x92
2-
stainless steel AISI 316L
Measuring range

Temperature range up to 80OC


up to 2m

Counterflange Floating element Ø50x48, floatness 0.55


SB5992
Side mounting
Signal converter inside of connection
Ø68 min Minimum head
48

level measurement
4 x M12 Resolution within 15mm
45

Output 4-20mA
Should be fixed
Ø13 for length of the stem
Ø50 more than 350mm

All dimensions are in mm.

Ljubljanska cesta 7, HR-51000 Rijeka / Croatia / tel. ++385 51 274 536 / fax 712 122 / [email protected] / www.inelteh.hr
04 · LEVEL DETECTING AND MEASUREMENT

M A G N E T I C

L E V E L

S W I T C H E S
MAGNETIC LEVEL SWITCHES
Designed for using on board ships, in petrol industries etc.
Material used (stainless steel AISI 316L) makes it suitable for
use in various liquids
Various vessel connections can be done
Top or side mounting
Submersible version with teflon cable
Using Intrinsic Safety Isolators can operate in hazardous area

ITMLS-01-110-92
90 90 TECHNICAL CHARACTERISTICS
Connection head protection IP-65
with cable gland PG-16
82

82

Wetside material stainless steel AISI 316L


Up to 3 floating elements can be installed

2
(if so, distance between any one 100mm min)
10

10
More floating elements can be installed

More floating elements can be installed


Flange: Standard 92x92 AISI 316L.
Switchig point 90

Switchig point 90
Other dimensions can be ordered

Other dimensions can be ordered


Other types can be ordered.
(min 40)

(min 40)
Flange type 92x92
Temperature range up to 120OC
can be ordered (AISI 316L)
Protection tube against dirt

AISI 316L

160 Electrical contacts: change-over P=60W Vac/Vdc: 400V


160

Counterflange Switching current 1A max


4 x M12 For other types of contact see Ordering informations
Ø68 min Floating element Æ50x48, floatness 0.55
Top mounting
For detail see Ø12
Ø50
M8
Ø60.3 x 1.6
Weight » 1,1 kg
standard SB5992
Protection tube against dirt, can be ordered

ITMLS-02-110-92 SUBMERSIBLE
Ø58 Ø58
TECHNICAL CHARACTERISTICS
Submersible version, IP-68 protection
75

75

Material: stainless steel AISI 316L


10 10 Up to 3 floating elements can be installed
2

(if so, distance between any one 100mm min)


10

10
More floating elements can be installed

More floating elements can be installed

Flange: 92x92 stainless steel AISI 316L


Switchig point 90

Switchig point 90
Other dimensions can be ordered

Other dimensions can be ordered

Temperature range up to 120OC


(min 40)

(min 40)

Flange type 92x92


can be ordered (AISI 316L)
Protection tube against dirt

AISI 316L Electrical contacts: change-over P=60W Vac/Vdc: 400V


Switching current 1A max
160

160

Counterflange For other types of contact see Ordering informations


4 x M12 Floating element Æ50x48, floatness 0.55
Ø68 min PTFE, teflon cable 3, 5, 7m or more can be ordered
Top mounting
For detail see
Ø12
Ø50
M8
Ø60.3 x 1.6
Weight » 1,4 kg with 5m cable
standard SB5992 Protection tube against dirt, can be ordered

ITMLS-02A-110-00 SUBMERSIBLE

M24 x 1.5
8 27 13

27 TECHNICAL CHARACTERISTICS
Submersible version, IP-68 protection
More floating elements can be installed
Switchig point 40

but without protection box for the cable


Other dimensions can be ordered

Material: stainless steel AISI 316L


Temperature range up to 120OC
Electrical contacts: change-over P=60W Vac/Vdc: 400V
100

Switching current 1A max


For other types of contact see Ordering informations
Floating element Æ50x48, floatness 0.55
PTFE, teflon cable 3, 5, 7m or more can be ordered
Ø12 Top mounting
Ø50
Weight » 0,5 kg (with 5m cable)

All dimensions are in mm.

ENGINEERING FOR ELECTRONIC EQUIPMENT AND SYSTEMS


04 · LEVEL DETECTING AND MEASUREMENT

ITMLS-03A-110-92
TECHNICAL CHARACTERISTICS
82 10 Flange type 92x92
AISI 316L Connection head protection IP-65
100 with cable gland PG-16
Wetside material stainless steel AISI 316L

More floating elements can be installed


Up to 3 floating elements can be installed

90

Switchig point 90
(if so, distance between any one 100mm min)

Other dimensions can be ordered


Flange: Standard 92x92 AISI 316L.
Other types can be ordered.
Temperature range up to 120OC

160
Counterflange
Electrical contacts: change-over P=60W Vac/Vdc: 400V
4 x M12
Switching current 1A max

48
Ø68 min For other types of contact see Ordering informations
Floating element Æ50x48, floatness 0.55
For detail see Ø12 Side mounting
standard SB5992 Ø50
Weight » 1,2 kg

ITMLS-03B-110-92
Counterflange
4 x M12 TECHNICAL CHARACTERISTICS
Ø68 min Ø50
Ø12
Connection head protection IP-65
with cable gland PG-16

More floating elements can be installed


For detail see Wetside material stainless steel AISI 316L
standard SB5992
Up to 3 floating elements can be installed
Other dimensions can be ordered
Flange type 92x92 (if so, distance between any one 100mm min)
AISI 316L
Flange: Standard 92x92AISI 316L.
160

Other types can be ordered.


Switchig point 90

82 10
48

Temperature range up to 120OC


Electrical contacts: change-over P=60W Vac/Vdc: 400V
Switching current 1A max
For other types of contact see Ordering informations
90

Floating element Æ50x48, floatness 0.55


100 Side mounting
Weight » 1,2 kg

ITMLS-04A-110-92 SUBMERSIBLE
75 10 Flange type 92x92
AISI 316L
TECHNICAL CHARACTERISTICS
100 Submersible version, IP-68 protection
Material: stainless steel AISI 316L
Ø58

Up to 3 floating elements can be installed


More floating elements can be installed
Switchig point 90

(if so, distance between any one 100mm min)


Other dimensions can be ordered

Flange: 92x92 stainless steel AISI 316L


Temperature range up to 120OC
20

Electrical contacts: change-over P=60W Vac/Vdc: 400V


160

Counterflange Switching current 1A max


4 x M12 For other types of contact see Ordering informations
48

Ø68 min
Floating element Æ50x48, floatness 0.55
PTFE, teflon cable 3, 5, 7m or more can be ordered
Ø12 Side mounting
For detail see Ø50
standard SB5992 Weight » 1,5 kg (with 5m cable)

ITMLS-04B-110-92 SUBMERSIBLE
Counterflange Ø50
Ø12
4 x M12 TECHNICAL CHARACTERISTICS
More floating elements can be installed

Ø68 min
Submersible version, IP-68 protection
Other dimensions can be ordered

Material: stainless steel AISI 316L


For detail see
standard SB5992 Up to 3 floating elements can be installed
(if so, distance between any one 100mm min)
160
Switchig point 90

75 10
48

Flange: 92x92 stainless steel AISI 316L


Temperature range up to 120OC
Flange type 92x92
AISI 316L Electrical contacts: change-over P=60W Vac/Vdc: 400V
Switching current 1A max
Ø58

For other types of contact see Ordering informations


100 Floating element Æ50x48, floatness 0.55
PTFE, teflon cable 3, 5, 7m or more can be ordered
20

Side mounting
Weight » 1,5 kg (with 5m cable)

All dimensions are in mm.


ITMLS-06A-110-92

TECHNICAL CHARACTERISTICS
Connection head protection IP-65
Flange 92x92 with cable gland PG-16
(material AISI 316L)
82 10 226 Wetside material stainless steel AISI 316L
Temperature range up to 120OC
Electrical contacts:
Counterflange change-over P=60W Vac/Vdc: 400V
4 x M12 Switching current 1A max
Ø68 min Floating element Ø64x120
Test mechanism available
90

Ø64
For detail see 90 Rod extension available
standard SB5992 Side mounting
Weight » 1,3 kg

ITMLS-06B-110-92 SUBMERSIBLE

TECHNICAL CHARACTERISTICS

Flange 92x92
Submersible version, IP-68 protection
75 10
(material AISI 316L)
226
Material stainless steel AISI 316L
Temperature range up to 120OC
Electrical contacts:
Counterflange change-over P=60W Vac/Vdc: 400V
Ø58

4 x M12 Switching current 1A max


Ø64

Ø68 min Floating element Ø64x120


90
Test mechanism available
20

For detail see


Rod extension available
standard SB5992 Side mounting
Weight » 1,55 kg

ITMLS-06AC-110-92
TECHNICAL CHARACTERISTICS
Submersible version, IP-68 protection
Material stainless steel AISI 316L
Temperature range up to 120OC
Electrical contacts:
82 10 226
change-over P=60W Vac/Vdc: 400V
Switching current 1A max
Floating element Ø64x120
Counterflange Test mechanism not available
4 x M12 Rod extension available
Ø68 min
PTFE, teflon cable 3, 5, 7m or more
Ø64

can be ordered
90

90
Additional protection against dirt
For detail see
standard SB5992 Side mounting
Weight » 1,45 kg

ITMLS-06BC-110-92 SUBMERSIBLE
TECHNICAL CHARACTERISTICS
Submersible version, IP-68 protection
Material stainless steel AISI 316L
Temperature range up to 120OC
Electrical contacts:
75 10 226
change-over P=60W Vac/Vdc: 400V
Switching current 1A max
Floating element Ø64x120
Counterflange Test mechanism not available
Ø58

4 x M12 Rod extension available


PTFE, teflon cable 3, 5, 7m or more
Ø64

Ø68 min
90 can be ordered
Additional protection against dirt
20

For detail see


standard SB5992 Side mounting
Weight » 1,8 kg

All dimensions are in mm.

ENGINEERING FOR ELECTRONIC EQUIPMENT AND SYSTEMS


04 · LEVEL DETECTING AND MEASUREMENT

ROD EXTENSIONS FOR HORIZONTAL TYPES OF LEVEL SWITCHES

700 max 120

Rod extensions are available


for following types of magnetic
level switches:

Ø64
ITMLS-06A-110-92
ITMLS-06B-110-92
ITMLS-06AC-110-92
ITMLS-06BC-110-92

TEST MECHANISM TYPE ITMLS-TM01

Material stainless steel AISI 316L


Protection IP 68 3bar (more on request)
Weight 0,430 kg

Test mechanism should be inserted between


magnetic level switch and tank connection.

PRINCIPLE OF OPERATION DIMENSIONS


FOR TEST
PUSH DOWN
25
Ø

MAGNETIC LEVEL TANK


SWITCH
65

NORMAL CONDITION Tube DN65 (Ø76.1x5)


29
76.1

92
Ø

MAGNETIC LEVEL TANK


SWITCH
R8

40
Flange 92x92

ALARM CONDITION

All dimensions are in mm.


ITMLS-06AV-110-92
Counterflange 90

4 x M12
TECHNICAL CHARACTERISTICS

82
Ø68 min
Flange 92x92
(material AISI 316L) Connection head protection IP-65
For detail see with cable gland PG-16

10
standard SB5992
Wetside material stainless steel AISI 316L

90
Temperature range up to 120OC
Electrical contacts: change-over P=30W Vdcmax: 500V
Rod extension Switching current 0.5A max
For other types of contact see Ordering informations
Floating element Ø64x120

A
Test mechanism available

Ø64
B With rod extension only
120 Top mounting
Weight » 1,6 kg

ITMLS-06ACV-110-92
90
Counterflange
TECHNICAL CHARACTERISTICS
4 x M12
82

Ø68 min Connection head protection IP-65


with cable gland PG-16
Wetside material stainless steel AISI 316L
10

For detail see


Temperature range up to 120OC
90

standard SB5992
Electrical contacts: change-over P=30W Vdcmax: 500V
Switching current 0.5A max
Rod extension For other types of contact see Ordering informations
Floating element Ø64x120
Test mechanism not available
A

With rod extension only


Ø64

B
Additional protection against dirt
120 Top mounting
Weight » 1,8 kg

ITMLS-06BV-110-92 SUBMERSIBLE
Ø58
Counterflange
4 x M12
TECHNICAL CHARACTERISTICS
75

Ø68 min
20 Flange 92x92
(material AISI 316L) Submersible version, IP-68 protection
Material stainless steel AISI 316L
10

For detail see


standard SB5992 Temperature range up to 120OC
90

Electrical contacts: change-over P=30W Vdcmax: 500V


Switching current 0.5A max
Rod extension For other types of contact see Ordering informations
Floating element Ø64x120
PTFE, teflon cable, 3, 5, 7m or more can be ordered
A

Test mechanism available


Ø64

B With rod extension only


120 Top mounting
Weight » 1,9 kg

ITMLS-06BCV-110-92 SUBMERSIBLE
Ø58
Counterflange
4 x M12
TECHNICAL CHARACTERISTICS
75

Ø68 min
20
Submersible version, IP-68 protection
Material stainless steel AISI 316L
Temperature range up to 120OC
10

For detail see


standard SB5992 Electrical contacts: change-over P=30W Vdcmax: 500V
90

Switching current 0.5A max


For other types of contact see Ordering informations
Rod extension Floating element Ø64x120
PTFE, teflon cable, 3, 5, 7m or more can be ordered
Test mechanism not available
A

With rod extension only


Ø64

B Additional protection against dirt


120 Top mounting
Weight » 2,15 kg

All dimensions are in mm.

ENGINEERING FOR ELECTRONIC EQUIPMENT AND SYSTEMS


04 · LEVEL DETECTING AND MEASUREMENT

ITMLS-07A-110-92 90

82
Flange type 92x92
(AISI 316L)

97 10
TECHNICAL CHARACTERISTICS
Counter weight

14
is used if "X" is Connection head protection IP-65
over 1000mm
with cable gland PG-16

15

Max 2000 (more on request)


90 53
Wetside material stainless steel AISI 316L

Fix stem each 500mm


Flange: 92x92 stainless steel AISI 316L

"X"
Stem
Stoper
adjustable Temperature range up to 120OC

Can be adjusted
Electrical contacts: change-over P=60W Vac/Vdc: 400V
Ø1
00 Switching current 1A max
For other types of contact see Ordering informations
Stoper Floating element Ø100
adjustable
Ø6
Top mounting
Weight » 2,1 kg

ITMLS-07B-110-92 SUBMERSIBLE
Ø58

75
30
20
97 10 TECHNICAL CHARACTERISTICS
Counter weight Submersible version, IP-68 protection
14

is used if "X" is
over 1000mm Material stainless steel AISI 316L
Flange: 92x92 stainless steel AISI 316L
15

Max 2000 (more on request)

90 53 Temperature range up to 120OC


Fix stem each 500mm

"X"

Stem Electrical contacts: change-over P=60W Vac/Vdc: 400V


Stoper
adjustable Switching current 1A max
Can be adjusted

For other types of contact see Ordering informations


Ø1
00 Floating element Ø100
PTFE, teflon cable 3, 5, 7m or more can be ordered
Stoper
adjustable
Top mounting
Ø6 Weight » 2,8 kg

COUNTERFLANGE 92x92 for welding to tank structure (material AISI 316L)


92 10

Ø68 2
Ø9
92

M12
M12x35

25
Tank structure

All dimensions are in mm.

ROD EXTENSION TABLE FOR VERTICAL TYPE ITMLS-06...V

HAVE TO BE FOLLOWED A / B <= 2 A + B = 750mm Amin = 50 / Amax = 500 B = 50 / B = 500


min max

A (mm) 50 100 200 500

B (mm) 25 50 100 250


ORDERING INFORMATIONS for basic types ITMLS-01 up to 04

ITMLS - 01 - 1100 - 92
Flange type
00 - Without flange thread M24X1.5 (AISI 316)
DN50* - Steel grade A, galvanised
R2 - 4 Threaded plug R2"
Inelteh 92 - 92x92 AISI 316 flange

Type of third contact


2 - Normally open
Magnetic level switch 3 - Normally closed

40 mm
Basic type

Min.

L3
01
02 Type of second contact
02A 0 - No second contact

L2
03A 1 - Change over 3rd

100 mm
03B 2 - Normally open contact

Min.

L1
04A or 04B 3 - Normally closed

2nd contact

100 mm
Min.
Number of contacts
1 - One contact Type of first contact
2 - Two contacts 1 - Change over
3 - Three contacts (only normally open 2 - Normally open 1st contact

70
or closed contacts can be used) 3 - Normally closed

Change over contacts Contact ratings: 60W max. / Switch. current: 1A max. / Vac/Vdc: 400V

Normally open Contact ratings: 60W max. / Switch. current: 1A max. / Vac/Vdc: 400 V
DO NOT FORGET Calculations: P=UxI (W), where P=power, U=voltage, I=current

ORDERING INFORMATIONS for basic type ITMLS-06...

ITMLS - 06 ACV - 100 - 92


- Ship's connection, flange 92x92
Inelteh - Material AISI 316L stainless steel

0 - No second contact
1 - Change-over
Magnetic level switch 2 - Normally open

Contact type
0 - Normally open or if you rotate complete
magn. level switch for 180°- normally close
(it is effectuated for side mounting only)
Basic type 06 Remark 2 1 - Change-over

A - Connection head, IP-65 with PG-16


cable gland
B - Submersible version, IP-68, with teflon 1 - One contact
cable (3, 5, 7 meters or more can be ordered) 2 - Two contacts (on special order only)

C - Mechanism protection from dirt, protection


rubber is included V - Vertical use with rod extension
- Specify only if is used (see "Table for rod extension")
- Test mechanism type ITMLS-TM01 is not available H - Horizontal use with rod extension
if additional protection from dirt is used Remark 1 (see "Rod extension dimensions")

Remark 1 V or H letter specify only if rod extension is necessary. Otherwise do not specify anything.

Remark 2 Change over contacts Contact ratings: 60W max. / Switch. current: 1A max. / Vac/Vdc: 400V

Normally open Contact ratings: 60W max. / Switch. current: 1A max. / Vac/Vdc: 400V
DO NOT FORGET Calculations: P=UxI (W), where P=power, U=voltage, I=current

Ljubljanska cesta 7, HR-51000 Rijeka / Croatia / tel. ++385 51 274 536 / fax 712 122 / [email protected] / www.inelteh.hr
04 · LEVEL DETECTING AND MEASUREMENT

WATER INGRESS DETECTION SYSTEM WID


Inelteh's water ingress detection system is designed for detecting sea water in holds of bulk carriers. Meets
SOLAS, IMC and requierments of major classification societes.

ALARM UNIT type ITDAC-14D


TECHNICAL CHARACTERISTICS
All functions for WID in one unit 144x144cm
Power supply 230V,AC and 24V,DC
12 alarms inputs in 6 groups for 6 holds
Any group can be blocked
Automatic dimmer
All connections directly to rear side
Intermittent tone for pre-alarms and continuos for alarms
LE signalisation of alarms, blocking facility, power/system
and line failure
"Block" programming using buttons on the front panel
Output relays for: - alarm
- pre-alarm
- common
- power/system failure
Flush or bulkhead mounting

SAFETY BARRIERS
TECHNICAL CHARACTERISTICS
Used when level switch is installed
in dangerous area
Can be delivered together with alarm unit
ITDAC-14D for bulkhead mounting or separate

MAGNETIC LEVEL SWITCH


type ITMLS-02A-110-WID
TECHNICAL CHARACTERISTICS
Robust construction, used material AISI 316L
IP-68
Can be delivered with teflon or standard
marine cable
Resistors network with reed switch enable
line failure indication
Local test mechanism
Remote test with water, even when
holds are loaded
Easy cleaning and changing the filter
Ship's connection R 2 ½

ENGINEERING FOR ELECTRONIC EQUIPMENT AND SYSTEMS


ALARM UNIT ITDAC-14D DIMENSIONS
144 138

ITDAC-14D
RIJEKA - CROATIA WATER INGRESS ALARM UNIT

MAIN ALARM MAIN ALARM

PRE-ALARM HOLD 1 HOLD 4 PRE-ALARM

BLOCK BLOCK

MAIN ALARM MAIN ALARM

PRE-ALARM HOLD 2 HOLD 5 PRE-ALARM


144

138
BLOCK BLOCK

MAIN ALARM MAIN ALARM


CUT-OUT
PRE-ALARM HOLD 3 HOLD 6 PRE-ALARM

BLOCK BLOCK

TEST BLOCK ACCEPT


Main POWER
Emerg. POWER

DEPTH IS 115mm

MAGNETIC LEVEL SWITCH type ITMLS-02A-110-WID DIMENSIONS


Water inlet for remote test
(Tube Ø8/Ø6 with coupling, optional)
Cable
1/4" (Teflon or marine should be specified)
2 1/2", outer Breather tube
(Tube Ø8/Ø6 with coupling, optional)
24

Inlet for breather tube, 1/4"


25

Inlet for remote test with water, 1/4"

Switching point
166

Floating element
Ø50x48
236

Filter
78

M8
Ø76.1
70

Local test Unscrew for


filter changing

SENSORS CONNECTION IN CASE OF DANGEROUS AREA


ITDAC-14D
Water Ingress Alarm Unit

+ - SENSORS' INPUTS

to ITDAC-14D
sensor's input

+
8 5 6 7 1 2
Safety barrier Safety barrier
"Stahl" Z787 OR "MTL" 787(SP)

1 4 3 2 3 4

SAFE AREA
DANGEROUS AREA

Sensor
All dimensions are in mm.

Ljubljanska cesta 7, HR-51000 Rijeka / Croatia / tel. ++385 51 274 536 / fax 712 122 / [email protected] / www.inelteh.hr