FSD Scrubber Type
FSD Scrubber Type
TYPE FSD
KYOWA
OPERATION MANUAL
WWW.KYOWA.CO.TH
2
CONTENTS
1.SPECIFICATIONS………….……………………………………………….. 2
2.EXTERNAL VIEW………………………………………………………….. 3
3.FUNCTION OF EACH SECTION………………………………………… 4
4.SAFETY CONTROL AND SAFETY OPERATION……………………… 5
5.TEST OPERATION………………………………………………………… 6
6.OPERATION ……………………………………………………………… 7
7.DAILY MAINTENANCE…………………………………………………… 9
8.MAINTENANCE AFTER LONG-TERM
SUSPENSION OF OPERATION……………………………………………. 11
9.DISASSEMBLY AND ASSEMBLY OF
COMPONENTS FOR MAINTENANCE SYSTEM ………………………. 11
10.TROUBLESHOOTING…………………………………………………… 13
11.GUARANTEE…………………………………………………………….. 14
WARNING
This system could be used only in a right purpose and right condition. If some
abnormal state occurred, stop the operation of gas generating source. Next, inspect exhaust
gas treatment system, and this system can be resumed after restoring all the breakdown
section perfectly.
3
Warning
The Kyowa FSD-type exhaust gas scrubber sucks in the exhaust gas and, after scrubbing,
discharges it into the air.The parts, which contact the exhaust gas are made of fiberglass reinforced
plastic, which has excellent anti-corrosion properties.
Please, read this manual carefully before operating this unit so that it operates to its full
performance and prevent malfunctions.This operation manual covers the general and basic precautions
for the unit. For details on operating the exhaust fan, the circulation pump and other devices. Please,
refer to each of the attached instruction manuals.
1. Specifications: (Refer to Specifications in part 2)
2. External View
2. Spray nozzle
To spray the absorbent water on the tower packing uniformly.
3. Mist separator.
To remove the droplets from exhaust gases, which is generated from the spraying inside the scrubber.
(1) Start
- Must sure that the circulation tank is filled with circulation water up to specified(overflow) level.
- Turn the circulation pump on before opening the delivery valve.
- After sure that the circulation pump is working correctly. Turn the exhaust fan on.
- Start supplying water.
- Measure the air flow rate in the initial operation and set it to the specified value.
(2) Stop
- Stop the water supply.
- Switch off the exhaust fan.
- Switch off the circulation pump.
(3) When the electric power is cut off. Turn the exhaust fan and circulation pump off. After the power
supply is recovered. Start the operation from the beginning.
(Start) (Stop)
Confirm the water level in the
Circulation tank
Operation
8
7.Daily maintenance
(1) Exhaust fan
1) V-BELT
The V-Belt might be stretched and slipped, especially at the initial stage of operation. If occurred,
adjust the tension of the V-Belt by sliding the slide base of the motor. Replace the V-Belt with a new
one according to the damage,which depends greatly upon r.p.m., operation term, condition of
installation,etc.
2) Bearing
Lubricate the bearing using high-grade grease with a lithium soup base every 2 to 6 months
depending upon r.p.m., operation hours, bearing temperature, etc. If unusual noise or vibration is
produced by damage, replace a new one.
(Grease to used)
Maker Brand name
Shell ALBANIA Nos.2 and 3
Cosmo REMAX Nos.2 and 3
Mobil MOBILUX no.2
3) Runner
Depending upon the kind of gas sucked in, dust might adhere to the runner or the runner
might be deformed by heat, and as the result, vibration occurs due to an unbalanced runner.
Because such vibration might cause a sudden breakage of the bearing or the runner. Clean or
replace the runner when vibration becomes intense.
4) Others
For details, refer to the attached ” KYOWA Anticorrosive Blower Instruction Manual KS Type”
2) Spray nozzles
If spraying isn’t uniform when viewed through the inspection port for spray nozzle. The nozzles
might be blocked. Remove and clean the nozzles.
3) Demister
The demister might similarly be blocked with dirt. So if the demister is clogged. Mist can
disperse from the stack or the exhaust gas suction capacity, might be reduced. In this case,
remove and clean or replace a new one.
(4) Circulation tank
1) Because deposits might be formed on the bottom of the circulation tank depending upon the
operation condition, periodically clean the circulation tank (every 3 months).
2) If operation is suspended when freezing may occur, completely remove the circulation water
from the circulation tank.
10
8.Maintenance after long-term suspension of operation
(1) When operation of the unit is suspended for a long-term, operate the exhaust fan and
the circulation pump once a month for more than an hour under normal operating conditions.
(2) When operation is suspended for a long-term in winter. When freezing might occur,
completely drain circulation water.Also drain the pump piping at the same time.
(3) Before operating the unit after a long–term suspension of operation, perform a test
operation in accordance with the procedure in “3. Test operation”.
10.Troubleshooting.
(Problem) (Cause) (Solution)
Gas isn’t sucked in Failure of the exhaust Refer to (trouble-shooting for blower)
or the suction power fan. in the attached(KYOWA Anticorrosive
is weak. Blower Instruction Manual KS Type).
The duct is clogged. Check and clean the inside of the dust.
11. Guarantee
The unit is guaranteed for one year after delivery. If any trouble occurs, please contact us even if the term
of the guarantee has expired.
13