Why LG VRF?
The benefits of LG VRF are numerous: less piping for installers, energy efficiency for owners, and modern indoor units
that complement every setting. Furthermore, LG Inverter scroll compressors optimize energy efficiency.
With the addition of LGRED° heating capability, the Multi V™ 5 provides operational performance
with heating down to -22˚F and cooling up to 122˚F for all units with no additional accessories
LGRED
Powerful Heat Technology
or modifications to the equipment, making it a robust solution for all climates. R E L I A B L E TO E X T R E M E D E G R E E S
131 ft.
Height
between
IDU-IDU
4. Quiet Operation
• Quiet indoor unit operation
down to 23 dB(A), comparable 50 dB(A)
Conversation
to the sound of rustling leaves at Home
40 dB(A) 60 dB(A)
Bird Calls Conversation
in Restaurant
• Simultaneous Operation: 14˚F to 81˚F DB R E L I A B L E TO E X T R E M E D E G R E E S 1. Down to 31 dB(A). See page 44 for HRU specification details.
2
LG VRF ADVANTAGES
Efficiency
Advanced features for superior efficiency • LG Inverter Scroll Compressor
Innovative high side-shell design creates a more
• Advanced Smart Load Control
compact unit providing the same capacity output,
Automatically adjusts system target pressures
with greater reliability in cold climates.
based on outdoor temperature and humidity
for increased cooling performance. • HiPOR™ (High-Pressure Oil Return)
• Active Refrigerant Control Oil is returned to the compressor through a
Depending on the operating mode and separate inlet pipe, so compressor energy is used to
conditions, the system refrigerant level is compress refrigerant only.
automatically adjusted for increased part load • Smart Oil Control
and heating efficiency. Eliminates timed oil-return cycles and takes hours
off of the time required to return oil compared to
• Variable Path Heat Exchanger
systems that use a timed oil-recovery cycle.
Depending on the operating mode and
conditions, both the refrigerant flow path and • Intelligent Heating
velocity are adjusted for improved efficiency. By monitoring the outdoor humidity, system
• Advanced Printed Circuit Board Cooling target pressures can be reduced to extend heating
Improved cooling performance of the inverter operation, delay defrost operation and reduce
printed circuit board by using liquid refrigerant power consumption.
instead of heat sink cooling methods.
Performance
Expansive operating range in cooling and heating without
adding accessories:
• LG Multi V™ 5 uses vapor injection technology
for improved heating performance in ambient
conditions as low as -22˚F.
• Using a variable path heat exchanger, LG Multi V™ 5
performs in low ambient conditions to provide
cooling down to 5˚F.
Comfort
• Quiet Operation
Multi V™ indoor units are among the quietest in
the industry, with rated sound levels as low as
23dB(A). In addition to temperature, airflow and
dehumidification, low sound levels contribute to a
Design Flexibility relaxing environment.
• Individualized Zone Control
• Higher-Elevation Piping Technology
Multi V™ solutions allow the user to control the
More floors with fewer systems. LG Multi V™ 5
space to the temperature desired. This further
eliminates the need to invest in extra systems
enhances comfort while promoting reduced
and saves on installation. Enjoy no heating
power consumption.
capacity losses due to long pipe length.
• Indoor Air Quality
• Compact & Lightweight
All Multi V™ indoor units incorporate a reusable,
More indoor zones, less outdoor space. When
washable filter. Since distribution and return ducts
space or access is at a premium, Multi V™ 5
are not required for this system, dust accumulation
offers significant cost advantages on large
is reduced, contributing to improved indoor air
projects.
quality.
MA
NJ
CA
GA
TX
Training
LG US Air Conditioning Technologies is headquartered near Atlanta in Alpharetta, Georgia, along with a full training
academy. Additional training academies are located in California, Texas, New Jersey, and Massachusetts. Since 2008,
our academies have trained thousands on the advantages of LG air conditioning products, and even more have been
trained through LG’s online training modules. World-class trainers with years of experience teach classes in duct-
free technology, with topics covering everything from installation to service for the full range of LG air conditioning
products. LG also has a number of strategically placed partner academies throughout the United States that offer a
number of LG-focused training classes as well.
For HVAC professionals, LG offers online instruction via our Learning Management System and classroom training at
our training academies, strategically placed throughout the country. Training is open to all contractors; ask your LG
Electronics authorized distributor for details. For more information and to find out how you can be part of the next
training class near you, visit https://lghvac.com/training.
4
5 LG Air Conditioning Technologies
TABLE OF CONTENTS
AIR SOURCE
Multi V S® 24
WATER SOURCE
AIR TECHNOLOGIES
Rooftop DOAS 39
Accessories 42
6
OUTDOOR UNIT
Lineup
System
Frames 2 3 4 5 6 8 10 12
Type
•• •• •• ••
• Heat Pump and Heat
Multi V™ 5 Recovery in the same
chassis
LGRED
Powerful Heat Technology • Available in 208-
RELIABLE TO EXTREME DEGREES
230V and 460V
Air
Source
• • • •• • •
• Heat Pump or Heat
Recovery Systems 1 1
Multi V S® • Single-Phase Power
Three-Phase Power
1
Multi V
WATER® 5 • Heat Pump and Heat
208-230V Recovery Systems
Water
Source
Multi V
• Heat Pump and Heat
WATER® 5 Recovery Systems
460V
14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 48
•• •• •• ••
•• •• •• •• •• •• ••
LINEUP
•• •• •• ••
8
INDOOR UNIT Lineup
Chassis 5 7 9 12 15 18
Gallery
• •
• • • • • •
Art Cool™
Mirror
4-Way (2’x2’)
4-Way (3’x3’)
• • • • •
Ceiling
Suspended
Ceiling Mounted
•
Low Static
• • • • •
Ceiling
Concealed
Convertible
Mid Static • • • • •
Ducted
Mid Static
High Static
• • • • •
Multi-
Position
Air Handler
Unit
Vertical / Horizontal
• •
With Case
• • • • •
• • • • •
Floor Standing
Without Case
Unit : kBtu/h
24 28 30 36 42 48 54 76 96
•
• • •
•
LINEUP
•
• • • • •
• • •
•
•
• • • • •
• • • • • • •
• • • • • •
•
•
10
AIR SOURCE
SOLUTIONS
MULTI V™ 5 MULTI V S®
Heat Pump and Heat Pump and
Heat Recovery Heat Recovery
6 to 42 Tons 3 to 4 Tons
LGRED
Powerful Heat Technology
LGRED
Powerful Heat Technology
R E L I A B L E TO E X T R E M E D E G R E E S R E L I A B L E TO E X T R E M E D E G R E E S
MULTI V S®
Heat Pump or
Heat Recovery
2 to 8 Tons
MULTI V™ 5
R E L I A B L E TO E X T R E M E D E G R E E S
ARUM072BTE5 ARUM***BTE5
Specifications Unit ARUM072BTE5 ARUM096BTE5 ARUM121BTE5 ARUM144BTE5
Frames ARUM072BTE5 ARUM096BTE5 ARUM121BTE5 ARUM144BTE5
Tons 6 8 10 12
Cooling Btu/h 72,000 96,000 119,700 144,000
Nominal Capacity
Heating Btu/h 81,000 108,000 135,000 162,000
Cooling Btu/h 69,000 92,000 114,000 138,000
Rated Capacity1
Heating Btu/h 77,000 103,000 129,000 152,000
Power Voltage V / Hz / Ø 208-230/60/3 208-230/60/3 208-230/60/3 208-230/60/3
Power/Communication Wiring No x AWG 2 x 18 2 x 18 2 x 18 2 x 18
Cooling ˚F 5 ~122 5 ~122 5 ~122 5 ~122
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Temperatures shown are for Simultaneous operation - primarily cooling. The simultaneous operation range (primarily heating) is 14°F to 61°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. Used in Heat Recovery Systems only.
5. The System Combination Ratio must be between 50 and 130%.
6. Due to our commitment to continued innovation, some specifications may be changed without notification.
12
MULTI V™ 5
LGRED
Powerful Heat Technology
R E L I A B L E TO E X T R E M E D E G R E E S
ARUM***BTE5
Specifications Unit ARUM168BTE5 ARUM192BTE5 ARUM216BTE5 ARUM241BTE5
Tons 14 16 18 20
Cooling Btu/h 168,000 192,000 216,000 233,100
Nominal Capacity
Heating Btu/h 189,000 216,000 243,000 243,000
Cooling Btu/h 160,000 184,000 206,000 222,000
Rated Capacity1
Heating Btu/h 180,000 206,000 230,000 230,000
Power Voltage V / Hz / Ø 208-230/60/3 208-230/60/3 208-230/60/3 208-230/60/3
Power/Communication Wiring No x AWG 2 x 18 2 x 18 2 x 18 2 x 18
Cooling ˚F 5 ~122 5 ~122 5 ~122 5 ~122
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Temperatures shown are for Simultaneous operation - primarily cooling. The simultaneous operation range (primarily heating) is 14°F to 61°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. Used in Heat Recovery Systems only.
5. The System Combination Ratio must be between 50 and 130%.
6. Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V™ 5
ARUM***BTE5
Specifications Unit ARUM264BTE5 ARUM288BTE5 ARUM312BTE5 ARUM336BTE5
ARUM096BTE5 ARUM096BTE5 ARUM096BTE5 ARUM121BTE5
Frames
ARUM168BTE5 ARUM192BTE5 ARUM216BTE5 ARUM216BTE5
Tons 22 24 26 28
Cooling Btu/h 264,000 288,000 312,000 336,000
Nominal Capacity
Heating Btu/h 297,000 324,000 351,000 378,000
Cooling Btu/h 252,000 276,000 298,000 320,000
Rated Capacity1
Heating Btu/h 282,000 308,000 332,000 358,000
Power Voltage V / Hz / Ø 208-230/60/3 208-230/60/3 208-230/60/3 208-230/60/3
Power/Communication Wiring No x AWG 2 x 18 2 x 18 2 x 18 2 x 18
Cooling ˚F 5 ~122 5 ~122 5 ~122 5 ~122
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Temperatures shown are for Simultaneous operation - primarily cooling. The simultaneous operation range (primarily heating) is 14°F to 61°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. Used in Heat Recovery Systems only.
5. The System Combination Ratio must be between 50 and 130%.
6. Due to our commitment to continued innovation, some specifications may be changed without notification.
14
MULTI V™ 5
LGRED
Powerful Heat Technology
R E L I A B L E TO E X T R E M E D E G R E E S
ARUM***BTE5
Specifications Unit ARUM360BTE5 ARUM384BTE5 ARUM408BTE5
ARUM144BTE5 ARUM168BTE5 ARUM192BTE5
Frames
ARUM216BTE5 ARUM216BTE5 ARUM216BTE5
Tons 30 32 34
Cooling Btu/h 360,000 384,000 408,000
Nominal Capacity
Heating Btu/h 405,000 432,000 459,000
Cooling Btu/h 344,000 366,000 390,000
Rated Capacity1
Heating Btu/h 384,000 410,000 434,000
Power Voltage V / Hz / Ø 208-230/60/3 208-230/60/3 208-230/60/3
Power/Communication Wiring No x AWG 2 x 18 2 x 18 2 x 18
Cooling ˚F 5 ~122 5 ~122 5 ~122
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Temperatures shown are for Simultaneous operation - primarily cooling. The simultaneous operation range (primarily heating) is 14°F to 61°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. Used in Heat Recovery Systems only.
5. The System Combination Ratio must be between 50 and 130%.
6. Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V™ 5
ARUM***BTE5
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Temperatures shown are for Simultaneous operation - primarily cooling. The simultaneous operation range (primarily heating) is 14°F to 61°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. Used in Heat Recovery Systems only.
5. The System Combination Ratio must be between 50 and 130%.
6. Due to our commitment to continued innovation, some specifications may be changed without notification.
16
MULTI V™ 5
LGRED
Powerful Heat Technology
R E L I A B L E TO E X T R E M E D E G R E E S
ARUM072DTE5 ARUM***DTE5
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Temperatures shown are for Simultaneous operation - primarily cooling. The simultaneous operation range (primarily heating) is 14°F to 61°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. Used in Heat Recovery Systems only.
5. The System Combination Ratio must be between 50 and 130%.
6. Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V™ 5
ARUM***DTE5
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Temperatures shown are for Simultaneous operation - primarily cooling. The simultaneous operation range (primarily heating) is 14°F to 61°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. Used in Heat Recovery Systems only.
5. The System Combination Ratio must be between 50 and 130%.
6. Due to our commitment to continued innovation, some specifications may be changed without notification.
18
MULTI V™ 5
LGRED
Powerful Heat Technology
R E L I A B L E TO E X T R E M E D E G R E E S
ARUM***DTE5
Tons 22 24 26 28
Cooling Btu/h 264,000 288,000 312,000 336,000
Nominal Capacity
Heating Btu/h 297,000 324,000 351,000 378,000
Cooling Btu/h 252,000 276,000 298,000 320,000
Rated Capacity1
Heating Btu/h 282,000 308,000 332,000 358,000
Power Voltage V / Hz / Ø 460/60/3 460/60/3 460/60/3 460/60/3
Power/Communication Wiring No x AWG 2 x 18 2 x 18 2 x 18 2 x 18
Cooling ˚F 5 ~122 5 ~ 122 5 ~ 122 5 ~ 122
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Temperatures shown are for Simultaneous operation - primarily cooling. The simultaneous operation range (primarily heating) is 14°F to 61°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. Used in Heat Recovery Systems only.
5. The System Combination Ratio must be between 50 and 130%.
6. Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V™ 5
ARUM***DTE5
Specifications Unit ARUM360DTE5 ARUM384DTE5 ARUM408DTE5
ARUM144DTE5 ARUM168DTE5 ARUM192DTE5
Frames
ARUM216DTE5 ARUM216DTE5 ARUM216DTE5
Tons 30 32 34
Cooling Btu/h 360,000 384,000 408,000
Nominal Capacity
Heating Btu/h 405,000 432,000 459,000
Cooling Btu/h 344,000 366,000 390,000
Rated Capacity1
Heating Btu/h 384,000 410,000 434,000
Power Voltage V / Hz / Ø 460/60/3 460/60/3 460/60/3
Power/Communication Wiring No x AWG 2 x 18 2 x 18 2 x 18
Cooling ˚F 5 ~ 122 5 ~ 122 5 ~ 122
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Temperatures shown are for Simultaneous operation - primarily cooling. The simultaneous operation range (primarily heating) is 14°F to 61°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. Used in Heat Recovery Systems only.
5. The System Combination Ratio must be between 50 and 130%.
6. Due to our commitment to continued innovation, some specifications may be changed without notification.
20
MULTI V™ 5
LGRED
Powerful Heat Technology
R E L I A B L E TO E X T R E M E D E G R E E S
ARUM***DTE5
Specifications Unit ARUM432DTE5 ARUM456DTE5 ARUM480DTE5 ARUM504DTE5
ARUM121DTE5 ARUM121DTE5 ARUM121DTE5 ARUM121DTE5
Frames ARUM121DTE5 ARUM121DTE5 ARUM144DTE5 ARUM168DTE5
ARUM192DTE5 ARUM216DTE5 ARUM216DTE5 ARUM216DTE5
Tons 36 38 40 42
Cooling Btu/h 430,500 455,700 476,700 504,000
Nominal Capacity
Heating Btu/h 486,000 513,000 540,000 567,000
Cooling Btu/h 410,000 434,000 454,000 480,000
Rated Capacity 1
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Temperatures shown are for Simultaneous operation - primarily cooling. The simultaneous operation range (primarily heating) is 14°F to 61°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. Used in Heat Recovery Systems only.
5. The System Combination Ratio must be between 50 and 130%.
6. Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V S® MULTI V S®
WITH LGRED° Heat Pump or Heat Recovery
Heat Pump and Heat Recovery 2 to 8 Tons
3 to 4 Tons
22
MULTI V S® WITH LGRED°
ARUM036GSS5
ARUM048GSS5
1. Nominal capacity applied with non-ducted indoor units, and is rated 0 ft. above sea level with 25 ft. of refrigerant line per indoor unit and a 0 ft. level difference between outdoor and indoor units. All
capacities are net with a Combination Ratio between 95–105%.
Nominal cooling capacity rating obtained with air entering the indoor unit at 80°F dry bulb (DB) and 67°F wet bulb (WB) and outdoor ambient conditions of 95°F dry bulb (DB) and 75°F wet bulb (WB).
Nominal heating capacity rating obtained with air entering the indoor unit at 70°F dry bulb (DB) and 59°F wet bulb (WB) and outdoor ambient conditions of 47°F dry bulb (DB) and 43°F wet bulb (WB).
2. Rated capacity is certified under AHRI Standard 210/240. See www.ahrinet.org for information.
3. The System Combination Ratio must be between 50–130%.
4. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
5. Power wiring is field provided, solid or stranded, and must comply with all local and national codes. Refer to the engineering manual for detailed electrical data.
6. Cooling range with the Low Ambient Baffle Kit (sold separately) is down to -9.9°F.
7. Multi V S® units with LGRED° ship from the factory configured for heat recovery operation. For heat pump operation, the DIP switch settings must be set accordingly. See the product installation manual for details.
ENERGY STAR® and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency.
Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V S®
ARUN024GSS4
ARUN038GSS4
ARUN048GSS4
ARUN060GSS4
1. Nominal capacity applied with non-ducted indoor units, and is rated 0 ft. above sea level with 25 ft. of refrigerant line per indoor unit and a 0 ft. level difference between outdoor and indoor units. All
capacities are net with a Combination Ratio between 95–105%.
Nominal cooling capacity rating obtained with air entering the indoor unit at 80°F dry bulb (DB) and 67°F wet bulb (WB) and outdoor ambient conditions of 95°F dry bulb (DB) and 75°F wet bulb (WB).
Nominal heating capacity rating obtained with air entering the indoor unit at 70°F dry bulb (DB) and 59°F wet bulb (WB) and outdoor ambient conditions of 47°F dry bulb (DB) and 43°F wet bulb (WB).
2. Rated capacity is certified under AHRI Standard 1230. See www.ahrinet.org for information.
3. The System Combination Ratio must be between 50–130%.
4. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
5. Power wiring is field provided, solid or stranded, and must comply with all local and national codes. Refer to the engineering manual for detailed electrical data.
6. Cooling range with the Low Ambient Baffle Kit (sold separately) is -9.9°F to +122°F.
Due to our commitment to continued innovation, some specifications may be changed without notification.
24
MULTI V S® HEAT RECOVERY
ARUB060GSS4
1. Nominal capacity applied with non-ducted indoor units, and is rated 0 ft. above sea level with 25 ft. of refrigerant line per indoor unit and a 0 ft. level difference between outdoor and indoor units. All
capacities are net with a Combination Ratio between 95–105%.
Nominal cooling capacity rating obtained with air entering the indoor unit at 80°F dry bulb (DB) and 67°F wet bulb (WB) and outdoor ambient conditions of 95°F dry bulb (DB) and 75°F wet bulb (WB).
Nominal heating capacity rating obtained with air entering the indoor unit at 70°F dry bulb (DB) and 59°F wet bulb (WB) and outdoor ambient conditions of 47°F dry bulb (DB) and 43°F wet bulb (WB).
2. Rated capacity is certified under AHRI Standard 1230. See www.ahrinet.org for information.
3. The System Combination Ratio must be between 50–130%.
4. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
5. Power wiring is field provided, solid or stranded, and must comply with all local and national codes. Refer to the engineering manual for detailed electrical data.
6. Cooling range with the Low Ambient Baffle Kit (sold separately) is down to -9.9°F.
Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V S®
ARUN072BSS5
ARUN096BSS5
1. Nominal capacity applied with non-ducted indoor units, and is rated 0 ft. above sea level with 25 ft. of refrigerant line per indoor unit and a 0 ft. level difference between outdoor and indoor units. All
capacities are net with a Combination Ratio between 95–105%.
Nominal cooling capacity rating obtained with air entering the indoor unit at 80°F dry bulb (DB) and 67°F wet bulb (WB) and outdoor ambient conditions of 95°F dry bulb (DB) and 75°F wet bulb (WB).
Nominal heating capacity rating obtained with air entering the indoor unit at 70°F dry bulb (DB) and 59°F wet bulb (WB) and outdoor ambient conditions of 47°F dry bulb (DB) and 43°F wet bulb (WB).
2. Rated capacity is certified under AHRI Standard 1230. See www.ahrinet.org for information.
3. The System Combination Ratio must be between 50–130%.
4. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
5. Power wiring is field provided, solid or stranded, and must comply with all local and national codes. Refer to the engineering manual for detailed electrical data.
6. Cooling range with the Low Ambient Baffle Kit (sold separately) is -9.9°F to +122°F.
Due to our commitment to continued innovation, some specifications may be changed without notification.
26
WATER SOURCE
SOLUTIONS
MULTI V WATER® 5
Heat Pump & Heat Recovery
6 to 48 Tons
LG Multi V WATER® 5 systems permit synchronous cooling and heating in different zones at
the same time. Units are available from 6 Tons to 48 Tons.
MULTI V WATER® 5
ARWM***BAS5
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745. Value is parenthesis is the maximum sound pressure at those conditions.
3. The System Combination Ratio must be between 50 and 130%.
Due to our commitment to continued innovation, some specifications may be changed without notification.
28
MULTI V WATER® 5 (208-230V)
HEAT PUMP /
HEAT RECOVERY
ARWM***BAS5
Tons 14 16 18 20 22 24
Cooling Btu/h 168,000 192,000 216,000 239,400 264,000 287,700
Nominal Capacity
Heating Btu/h 189,000 216,000 243,000 269,000 297,000 324,000
Cooling Btu/h 160,000 184,000 206,000 228,000 252,000 274,000
Rated Capacity1
Heating Btu/h 180,000 206,000 230,000 256,000 282,000 308,000
Power Voltage V / Hz / Ø 208-230/60/3 208-230/60/3 208-230/60/3 208-230/60/3 208-230/60/3 208-230/60/3
Power/Communication Wiring No x AWG 2 x 18 2 x 18 2 x 18 2 x 18 2 x 18 2 x 18
64-3/16 x 64-3/16 x 64-3/16 x 64-3/16 x 64-3/16 x 64-3/16 x
Dimensions (W×H×D) Body in
44-3/32 x 21-17/32 44-3/32 x 21-17/32 44-3/32 x 21-17/32 44-3/32 x 21-17/32 44-3/32 x 21-17/32 44-3/32 x 21-17/32
Net lbs 322 x 2 322 x 2 322 x 2 322 x 2 322 x 2 322 x 2
Weight
Shipping lbs 340 x 2 340 x 2 340 x 2 340 x 2 340 x 2 340 x 2
Sound Pressure2 dB(A) 52 (65) 53 (65) 57 (65) 59 (65) 59 (65) 59 (65)
Cooling ˚F 50 ~ 113 50 ~ 113 50 ~ 113 50 ~ 113 50 ~ 113 50 ~ 113
Water Temperature Range Heating ˚F 23 ~ 113 23 ~ 113 23 ~ 113 23 ~ 113 23 ~ 113 23 ~ 113
Synchronous ˚F 23 ~ 113 23 ~ 113 23 ~ 113 23 ~ 113 23 ~ 113 23 ~ 113
High-Side Shell High-Side Shell High-Side Shell High-Side Shell High-Side Shell High-Side Shell
Type
DC Scroll DC Scroll DC Scroll DC Scroll DC Scroll DC Scroll
Compressor (Inverter Scroll) Oil Type PVE/FVC68D PVE/FVC68D PVE/FVC68D PVE/FVC68D PVE/FVC68D PVE/FVC68D
Quantity 2 2 2 2 2 2
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Heat Exchanger Flow Rate Nominal GPM 20.3 + 25.4 25.4 + 25.4 25.4 + 30.4 30.4 + 30.4 30.4 + 35.5 35.5 + 35.5
Pressure Drop ft wg 3.47 / 5.20 5.20 / 5.20 5.20 / 7.23 7.23 / 7.23 7.23 / 9.63 9.63 / 9.63
Liquid Line in (OD) 3/8 + 3/8 3/8 + 3/8 3/8 + 1/2 1/2 + 1/2 1/2 + 1/2 1/2 + 1/2
High Pressure Vapor Line in (OD) 3/4 + 3/4 3/4 + 3/4 3/4 + 7/8 7/8 + 7/8 7/8 + 7/8 7/8 + 7/8
Low Pressure Vapor Line
Piping in (OD) 3/4 + 7/8 7/8 + 7/8 7/8 + 1-1/8 1-1/8 + 1-1/8 1-1/8 + 1-1/8 1-1/8 + 1-1/8
(Heat Recovery only)
Water Inlet / Outlet in (ID) 1-1/2 + 1-1/2 1-1/2 + 1-1/2 1-1/2 + 1-1/2 1-1/2 + 1-1/2 1-1/2 + 1-1/2 1-1/2 + 1-1/2
Condensate Pipe in (ID) 3/4 + 3/4 3/4 + 3/4 3/4 + 3/4 3/4 + 3/4 3/4 + 3/4 3/4 + 3/4
Type R410A R410A R410A R410A R410A R410A
Refrigerant Charge lbs 7.7 + 7.7 7.7 + 7.7 7.7 + 7.7 7.7 + 7.7 7.7 + 7.7 7.7 + 7.7
Control EEV EEV EEV EEV EEV EEV
Maximum Number of Indoor Units3 29 32 35 39 42 45
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745. Value is parenthesis is the maximum sound pressure at those conditions.
3. The System Combination Ratio must be between 50 and 130%.
Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V WATER® 5
ARWM***BAS5
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745. Value is parenthesis is the maximum sound pressure at those conditions.
3. The System Combination Ratio must be between 50 and 130%.
Due to our commitment to continued innovation, some specifications may be changed without notification.
30
MULTI V WATER® 5 (460V)
HEAT PUMP /
HEAT RECOVERY
ARWM***DAS5
Tons 6 8 10 12 14 16
Cooling Btu/h 72,000 96,000 119,700 144,000 168,000 192,000
Nominal Capacity
Heating Btu/h 81,000 108,000 135,000 162,000 189,000 216,000
Cooling Btu/h 69,000 92,000 114,000 138,000 160,000 184,000
Rated Capacity 1
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745. Value is parenthesis is the maximum sound pressure at those conditions.
3. The System Combination Ratio must be between 50 and 130%.
Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V WATER® 5
ARWM***DAS5
Tons 16 18 20 22 24 30
Cooling Btu/h 192,000 216,000 239,400 264,000 287,700 360,000
Nominal Capacity
Heating Btu/h 216,000 243,000 269,000 297,000 324,000 405,000
Cooling Btu/h 184,000 206,000 228,000 252,000 274,000 344,000
Rated Capacity 1
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745. Value is parenthesis is the maximum sound pressure at those conditions.
3. The System Combination Ratio must be between 50 and 130%.
Due to our commitment to continued innovation, some specifications may be changed without notification.
32
MULTI V WATER® 5 (460V)
HEAT PUMP /
HEAT RECOVERY
ARWM***DAS5
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745. Value is parenthesis is the maximum sound pressure at those conditions.
3. The System Combination Ratio must be between 50 and 130%.
Due to our commitment to continued innovation, some specifications may be changed without notification.
34
ERV (ENERGY RECOVERY VENTILATOR)
ARVU*****A2
The LG ERV system allows users to exchange indoor air with outdoor air in order to improve the air quality by reducing the
temperature and humidity of incoming fresh air. Easy to maintain while providing superior energy savings and performance,
LG ERV is an ideal solution for hotels, dormitories, restaurants, hospitals, retail establishments, theaters, schools and office
buildings.
Specifications Unit 053ZE 063ZE 093ZF 123ZF
Capacity CFM 470 590 880 1,180
Performance
Power Input (SH1) Watts 360 470 720 930
Operation Range °F DB 14 ~113 14 ~113 14 ~113 14 ~113
Air-to-Air Heat Exchanger Cross-Flow Fixed Core Cross-Flow Fixed Core Cross-Flow Fixed Core Cross-Flow Fixed Core
Heat Exchanger Data
Quantity 1 1 1 1
Temperature Cooling (Fan Speed SH) % 62 59 62 59
Exchanger
Efficiency Entering Water Temp Range °F 41~113 53-167
Accessories
Description Model
PI-485 PFNFP14A0
1. SH - Super-high condensate drain not required. ERV temperature and enthalpy exchange efficiencies are in
accordance with AHRI 1060 test conditions, 100% airflow, and 0” external static pressure. AHRI Certified - Air-to-Air ERV
Cooling: Outdoor 95°F DB, 78°F WB; Exhaust 75°F DB, 63°F WB AHRI Standard 1060
Heating: Outdoor 35°F DB, 33°F WB; Exhaust 70°F DB, 58°F WB Energy Recovery COMPONENT is certified. Actual performance is
Due to our commitment to continued innovation, some specifications may be changed without notification. in packaged equinment may vary.
.
ARNU483B8Z4
ARNU763B8Z4
ARNU963B8Z4
TECHNOLOGIES
Heating Min °F DB 23 23 23
Refrigerant Type2 R410A R410A R410A
AIR
Refrigerant Control EEV EEV EEV
Sound Power3 dB(A) 54 56 57
Unit Data Dimensions (W×H×D) in 61-1/2 x 18-1/8 x 27-1/8 61-1/2 x 18-1/8 x 27-1/8 61-1/2 x 18-1/8 x 27-1/8
Net Unit Weight lbs 161 161 161
Shipping Weight lbs 191 191 191
Communication Cable4 No. x AWG 2 x 18 2 x 18 2 x 18
Type Sirocco Sirocco Sirocco
Motor 1 1 1
Fan Motor/Drive Brushless Digitally Controlled / Direct Brushless Digitally Controlled / Direct Brushless Digitally Controlled / Direct
Airflow Rate (H/M/L) CFM 708/477/477 837 / 446 / 446 1,261 / 837 / 837
External Static Pressure in wg 0.7 0.87 0.87
Liquid Line (OD) in 3/8 Flare 3/8 Flare 3/8 Flare
Piping (Main Coil)
Vapor Line (OD) in 5/8 Brazed 3/4 Brazed 7/8 Brazed
Condensate Condensate Line (OD) in 1 1 1
MCA A 2.7 2.7 2.7
Electrical Data MOP A 15 15 15
Power Supply V / Hz / Ø 208-230/60/1 208-230/60/1 208-230/60/1
Accessories
Model
Description Model
High-Capacity Filter Box for B8 HSD Chassis ZFBXB801A
36
AIR HANDLING UNIT (AHU) CONVERSION KIT
Solution to extend LG VRF technology to third-party Air Handling Units.
Communication Kit
PAHCMR000 PAHCMS000
Specifications
Combination Dimensions (in)
Type Model Name Description
Outdoor Expan- Central
EEV Kit controller W H D Weight
unit sion Kit
NOTE: Available functions/features may differ based on the connected system. Due to our commitment to continued innovation, some specifications may be changed without notification.
Digital input
Mode Cooling/Heating only - -
(Non-voltage)
Controlling
Digital input
Fan Step High/mid/low (three steps) Applied Not Applied
(Non-voltage)
Room Temperature Control Cooling 64 ~ 86oF, Heating 60 ~ 86oF By wired controller* Analog input 0V 10 V
Supply Air Temperature Compressor Off, Compressor Off & Fan Off,
- Analog input 0V 10 V
(by outdoor capacity control) 40 ~ 100% capacity control
Specifications
Dimensions (in)
Type Model Name Capacity Range
W H D
TECHNOLOGIES
PRLK048A0 8 Tons maximum 8-5/8 15-15/16 3-5/16
AIR
PRLK096A0 16 Tons maximum 8-5/8 15-15/16 3-5/16
EEV Kit
PRLK396A0 32 Tons maximum 8-1/2 13-1/2 7-1/8
Can be used in combination with or without indoor units. Several EEV kits can be connected to a single outdoor unit.
* In order for the PRLK594A0 to work with the PAHCMS000 the EV Control Module is required - PAEEVA020. This module will come in the box with the PRLK594A0.
System Architecture
MULTI V™ Application (in Combination with third-party AHU)
Field Supplied
Controller Comm. kit
Refrigerant Piping *DDC
Communication Wire
Sensor Signal
*DDC : Digital Direct Controller Return Air Exhaust Air Outdoor Air Supply Air
EEV kit
ODU
IDU
CTRL
38
ROOFTOP DOAS
AR-DC**-**A
Tested to UL1995 AR-DE**-**A
AR-DR**-**A
The LG Rooftop DOAS product line ranges from 3 to 70 Tons in cooling capacity and up to 18,000 CFM of airflow capacity.
Rooftop DOAS units are highly configurable to meet any local design requirement such as heating options including indirect gas
furnace with modulating gas controls, SCR controlled electric, or hot water coil options. Available with inverter scroll or digital
scroll compressors, split systems, bottom or side discharge.
Cabinet Chassis Size 02 123 223 32 35
AR-DR02-03A AR-DC12-05A AR-DC22-15A AR-DC22-15A AR-DC35-30A
AR-DR02-04A AR-DC12-07A AR-DC22-17A AR-DC22-17A AR-DC35-40A
AR-DR02-05A AR-DC12-10A AR-DC22-20A AR-DC22-20A AR-DC35-50A
AR-DR02-06A AR-DC12-12A AR-DC22-25A AR-DC22-25A AR-DC35-60A
AR-DR02-07A AR-DC12-15A AR-DC22-30A AR-DC22-30A AR-DC35-70A
AR-DE12-05A AR-DE22-15A AR-DE32-25A AR-DE35-30A
AR-DE12-07A AR-DE22-17A AR-DE32-30A AR-DE35-40A
Model Numbers1,2 AR-DE12-10A AR-DE22-20A AR-DE32-40A AR-DE35-50A
AR-DE12-12A AR-DE22-25A AR-DE32-50A AR-DE35-60A
AR-DE12-15A AR-DE22-30A AR-DR32-25A AR-DE35-70A
AR-DR12-05A AR-DR22-15A AR-DR32-30A AR-DR35-30A
AR-DR12-07A AR-DR22-17A AR-DR32-40A AR-DR35-40A
AR-DR12-10A AR-DR22-20A AR-DR32-50A AR-DR35-50A
AR-DR12-12A AR-DR22-25A AR-DR35-60A
AR-DR12-15A AR-DR22-30A AR-DR35-70A
Nominal Tons 3, 4, 5, 6, 7 5, 7.5, 10, 12.5, 15 15, 17.5, 20, 25, 30 25, 30, 40, 50 30, 40, 50, 60, 70
Cooling Components Digital Scroll Not Available Not Available Not Available Not Available Not Available
Indirect Gas Furnace Maximum (MBH) 200 300 500 1,200 1,200
Minimum (KW) 4 15 35 35 50
Accessories
LG Rooftop DOAS units are highly customizable with many accessories available to meet your application needs. To design an LG
Rooftop DOAS unit and determine which accessory models are appropriate, use the LG CAPS (Computer-Aided Product
Selection) software available through myLGHVAC.com.
1. AR-DR unit types include cooling and heating. AR-DE unit types include cooling, heating, and an ERV wheel.
2. Voltages are selectable between 208, 230, or 460 volts (all 3ø).
3. Air-Source Heat Pump option is available for the 12 and 22 DOAS cabinet chassis size, up to 30 Tons, with inverter compressors as standard.
ARND093DCR4
LG Split Compact Dedicated Outdoor Air System (DOAS) units provide 100% outdoor air in heating, cooling, and
dehumidification modes. Working with LG VRF systems, the LG Split Compact DOAS unit optimizes energy savings and
performance.
TECHNOLOGIES
Moisture Removal Capacity lb/h 33.0 55.0 67
AIR
Heating Mode Performance Capacity Btu/h 40,000 51,000 59,900
Cooling Max °F DB/WB 122/78 122 / 78 122 / 78
Entering Air
Heating Min °F DB 14 (10)144 14
Refrigerant Type1 R410A R410A R410A
Refrigerant Control EEV EEV EEV
Sound Power2 dB(A) 60 75 72
Unit Data Dimensions (W×H×D) in 75 x 21-11/16 x 45 75 x 21-11/16 x 45 75 x 21-11/16 x 45
Net Unit Weight lbs 342 397 397
Shipping Weight lbs 381 437 437
Communication Cable3 No. x AWG 4 x 18 4 x 18 4 x 18
Type Sirrocco 3D Plug 3D Plug
Motor (HP/W) 0.33 / 250 1 / 750 1 / 750
Fan Motor/Drive ECM / Direct ECM / Direct ECM / Direct
Airflow Rate5 CFM 500 - 900 1,000 - 1,500 1,000 - 2,000
External Static Pressure in wg 1.0 2.0 1.5
Liquid Line (OD) in 3/8 Brazed 1/2 Brazed 1/2 Brazed
Piping High Pressure Vapor (OD) in 5/8 Brazed 7/8 Brazed 3/4 Brazed
Low Pressure Vapor (OD) in 3/4 Brazed 1-1/8 Brazed 1-1/8 Brazed
Condensate Condensate Line (OD) in 1 1 1
MCA A 2.5 7.5 7.3
Electrical Data MOP A 15 15 15
Power Supply V / Hz / Ø 208-230/60/1 208-230/60/1 208-230/60/1
Filter Outdoor 2" Merv 8 (25"x20") 2” Merv 8 (25” x 20”) 2” Merv 8 (25” x 20”)
Accessories
LG DOAS units are highly customizable with many accessories available to meet your application needs. To design an LG DOAS
unit and determine which accessory models are appropriate, use the LG CAPS (Computer-Aided Product Selection) software
available through myLGHVAC.com.
1. Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608 of CAA.
2. Sound power levels are tested under AHRI 260 Standard.
3. All communication cable to be minimum 18 AWG, 4-conductor, twisted, stranded, shielded and must comply with applicable local and national codes. Ensure the communication cable is properly grounded at
the outdoor unit only. Do not ground the communication cable from the outdoor unit to the DOAS unit at any other point.
4. A maximum of (2) DOAS units connected to (1) ODU. A minimum 12 Ton ODU for (1) DOAS unit connection and minimum 30 Ton ODU for (2) DOAS unit connection.
5. Both ARND153DCR4 and ARND203DCR4 can be utilized for applications requiring CFM as low as 900CFM. A minimum 6-Ton unit or 8-Ton LG MV 5 HR unit is required based on the application
CSA Group® is a registered trademark of Canadian Standards Association
40
HEAT RECOVERY UNIT
PRHR023A
PRHR033A
PRHR043A
PRHR023A PRHR033A PRHR043A
PRHR063A (2-branch Unit) (3-branch Unit) (4-branch Unit)
PRHR083A
PRHR063A PRHR083A
Features (6-branch Unit) (8-branch Unit)
• Max. 64 indoor units can be connected (Max. eight indoor units per branch)
• Easy installation with auto pipe detect
• Delivers maximum efficiency using the subcooling cycle within the HR Unit
Models Applied
• MULTI V™ 5 Heat Recovery
• MULTI V WATER® 5 Heat Recovery
• Multi V S® Heat Recovery
Specifications
Specification Unit PRHR023A PRHR033A PRHR043A PRHR063A PRHR083A
Number of Indoor Unit Ports2 2 3 4 6 8
Power Input (Cooling / Heating) Watts 39.8 / 37.2 39.8 / 37.2 39.8 / 37.2 75.9 / 72.1 75.9 / 72.1
Each Port Btu/h 60,000 60,000 60,000 60,000 60,000
Max Port Capacity
Sum of Ports Btu/h 120,000 180,000 230,000 230,000 230,000
Power Supply V/Hz/Ø 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1
Electrical
Rated Amps A 0.06 0.06 0.06 0.09 0.09
Port Liquid Line in 3/8 3/8 3/8 3/8 3/8
Port Vapor Line in 5/8 5/8 5/8 5/8 5/8
Piping System Liquid Line in 3/8 1/2 5/8 5/8 5/8
System Vapor Line High in 3/4 7/8 7/8 7/8 7/8
System Vapor Line Low in 7/8 1 1/8 1 1/8 1 1/8 1 1/8
Cooling Mode dB(A) 31 31 31 31 31
Sound Pressure Data Heating Mode dB(A) 31 31 31 31 31
Simultaneous dB(A) 38 38 38 38 38
Net Unit Weight lbs 33 37 40 60 68
Weight
Shipping Weight lbs 46 50 53 75 82
30-15/16 x 25-7/8 x 30-15/16 x 25-7/8 x 30-15/16 x 25-7/8 x 43-13/16 x 25-7/8 x 43-13/16 x 25-7/8 x
Dimensions W×D×H in
8-9/16 8-9/16 8-9/16 8-9/16 8-9/16
Air Guide Air Guide Hail Guard Low Ambient Baffle Kit Wind Baffle Low Ambient Kit Cool/Heat Variable Water
Selector Flow Control
Kit
ACCESSORIES
Type Model Description Used with
PQSH1200 Drain Pan Heater ARUN024GSS4 & ARUN060GSS4
ZPLT1A51A Drain Pan Heater (208/230V) Multi V™ 5 (6 Ton Chassis)
ZPLT1A52A Drain Pan Heater (208/230V) Multi V™ 5 (8 to 20 Ton Chassis)
Drain Pan Heater Base
ZPLT2A51A Drain Pan Heater (460V) Multi V™ 5 (6 Ton Chassis)
ZPLT2A52A Drain Pan Heater (460V) Multi V™ 5 (8 to 20 Ton Chassis)
42
UNIT NOMENCLATURE
Outdoor Units and Heat Recovery Units
ARU M 072 B T E 5
Family Type Capacity Electrical Airflow Efficiency Generation
Ratings Configuration
Generation 5 Fifth
PRHR 02 3A
Family Number of Ports Series
Number
Due to our commitment to continued innovation, some specifications may be changed without notification.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
ARW M 072 B A S 5
Family Type Capacity Electrical Airflow Efficiency Generation
Ratings Configuration
Efficiency S Standard
Generation 5 Fifth
44
NEED IMAGE
46
Variable Refrigerant Flow (VRF) Multi-Split AC and HP
AHRI Standard 1230
©2024 LG Electronics U.S.A., Inc. All rights reserved. Document Number: PC_VRF_Systems_05_24
The AHRI Certified® mark indicates LG Electronics (LG) participation in the AHRI Certification program. For verification of individual certified products, go to www.ahridirectory.org.
CSA Group® is a registered trademark of Canadian Standards Association. All indoor and outdoor units are certified by the CSA Group.
USGBC® and the related logo are trademarks owned by the U.S. Green Building Council and are used with permission.