Number of Exits For Place of Assembly For 600
Number of Exits For Place of Assembly For 600
3 exits
Maximum occupant load for a class C public assembly.
50-300
Minimum number of exit for an Institutional type of structure.
2 exits
Maximum travel distance between room door intended as exit access and exit with
sprinkler system for institutional use.
30 mts.
Maximum travel distance from the door of any room to exit for hotels with sprinkler.
30 mts.
Maximum travel distance from the main entrance door to exit for apartments with
sprinkler.
31 mts.
Minimum increase in width for an aisle per linear meter.
2.5 cms
Minimum width of an aisle serving an occupant of 60 or more serving one side for a
public assembly building.
91 cms.
Minimum width of an aisle serving an occupant of 60 or more serving two sides for a
public assembly building.
1.00 mts
Minimum width of an aisle serving an occupant of below 60 for a public assembly
building.
76 cms.
Minimum width of an aisle for an educational use building.
1.80 mts
Minimum width of an aisle for hospitals or nursing homes.
2.44 mts.