FREQUENCY 47 Hz – 63 Hz
SUPPORTED GROUNDING SYSTEMS The charging station must be properly grounded.
Following grounding system are supported: TN-S, TN-C, TN-C-S and TT under special conditions. Where this is
possible local grounding should be done. IT grounding system supported only with use of transformer.
CHARGER OUTPUT
NUMBER OF CHARGING OUTPUTS (SOCKETS) 2
NOMINAL VOLTAGE (SINGLE-PHASE VEHICLE CONNECTED) Power supply voltage 230 V AC (-10 % , +10 %) and 120 V AC (-10 %, +10 %)
PER CONNECTOR On-board car charger nominal voltage depends on the car specification and typically reaches values between
100 V dc and 500 V dc.
NOMINAL VOLTAGE (THREE-PHASE VEHICLE CONNECTED) Power supply voltage 400 V AC (-10 %, +10 %) and 208 V AC (-10 %, +10 %)
PER CONNECTOR On-board car charger nominal voltage depends on the car specification and typically reaches values between
Electrical specification
100 V dc and 500 V dc. On a three phase charging station single and three phase vehicles can charge.
NOMINAL CURRENT PER PHASE PER CONNECTOR Max 32 A per phase (for each of two sockets)
Three phase model 3 x 32A.
Can be adjusted through charging station settings.
MAXIMUM CHARGING POWER PER CONNECTOR 22.1 kW, for each of two sockets
Max. power can be adjusted (lowered) when the charging station is installed and later using the power
management algorithms and power management settings using the user interface (mobile app, web app).
CHARGING SOCKET TYPE Two Type 2 sockets compliant with IEC 62196-2
• Sockets without status LED light (default).
• Sockets with status LED light (optionally).
• Sockets with shutter (optionally).
ELECTRICAL PROTECTION
DIFFERENTIAL PROTECTION Two residual current devices with Δ I = 30 mA.
Different options possible:
• DC fault current sensor 6 mA, default option.
• RCD Type A, RCD Type A EV, RCD Type B, optionally. ●
Compliant with the following standards:
• IEC 61851, IEC 62955, IEC/EN 62423 (Type B).
SURGE AND OVERVOLTAGE PROTECTION Installed in external electrical cabinet or in charging
Optional
station.
OVERCURRENT PROTECTION One main miniature circuit breaker (MCB) 80 A, two MCB's
40 A and MCB 6 A for electronics. All MCB's have tripping
characteristics C. ●
Rated short time withstand current: 10 kA.
COMMUNICATION PROTOCOLS
OCPP • OCPP 1.6 SOAP (fully supported).
• OCPP 1.6 JSON (all messages /methods supported).
• OCPP 2.0 JSON (upcoming).
• Additionally: Custom data transfer messages supported (for pricing and on display advertising).
• Allows OCPP communication with multiple nodes.
MODBUS TCP SERVER Used for integration with Smart Home/Smart building.
• Modbus registers table can be provided.
USER INTERFACES
TRUE COLOR LCD DISPLAY WITH TOUCH INTERFACE Specifications:
• LCD visual dimensions: 118.5 x 77.6 mm.
• Resolution: 800 x 480 pixels.
• 5-inch touch display true color (16 MB RGB).
●
• Sunlight readable, 12 o'clock view angle.
WEB INTERFACE FOR LOCAL USERS AND MAINTENANCE Embedded web interface with responsive design (PC,
tablet, phone).
It allows charger configuration, online control of charging session, enables ●
reporting, diagnostics/trouble shooting and firmware upgrades.
AUTHORIZATION USING PIN Users and PIN’s configurable through charger web
interface. ●
BASIC MECHANICAL SPECIFICATION
DIMENSIONS (HXWXD) 134.3 x 31.2 x 20.0 [cm], middle point height of charging sockets is 108 cm.
WEIGHT 38 kg (weight depending on the actual configuration).
DIMENSION INCLUDING PACKAGING (HXWXD) Packaging adds 10 cm to all dimensions of the product.
WEIGHT INCLUDING PACKAGING Packaging adds 5 kg to the charging station.
CASING MATERIAL Stainless steel with extra anti-corrosion protection (powder coated) and
polycarbonate display cover. UI holder material: fibre-reinforced ABS.
CASING COLOR Grey and grey.
Mechanical specification
ENVIRONMENTAL SPECIFICATIONS
ENCLOSURE INGRESS PROTECTION IP 54
in testing with IK10. ●
TEMPERATURE RANGE Operation temperature range: -25 °C to +65 °C
Storage temperature range: -40 °C to +70 °C
Product extendable with thermostat and heater.
●
HUMIDITY Up to 95 % relative humidity, non-condensing
●
MAXIMUM ALTITUDE 2000 m
●
VANDALISM PROTECTION
IMPACT PROTECTION IK10
●
PLUG LOCKING Plug locking operation can be enabled or disabled in
charger configuration. Optional
DOOR LOCKING Three point door locking with single mechanism. Single key access. Door open
sensor. Device tilt sensor.
MAINTENANCE
FIRMWARE UPDATE Firmware update done through backend system or web
interface. ●
ACCESS TO SERVICE AREA Service doors with key.
●
FUNCTIONS SUPPORTED THROUGH SERVICE AREA Access to:
• Ethernet.
• Mobile SIM.
• Charger system reset.
• Charger configuration reset.
• Protection manipulation. ●
• RCD protection test button (pressed once per year).
• Connection to the power supply.
• Configurable digital inputs (DI) and digital outputs (DO).
PREVENT OVERLOADING MAIN FUSE – GRID CONNECTION By using Load Guard device:
POINT • Static limit of maximum allowed charging current per
phase.
Software solutions