Vista 20SE Programming
Vista 20SE Programming
2-PARTITIONED
SECURITY SYSTEM
PROGRAMMING
FORM
–2–
*36 ENTRY DELAY 2 (zone type 02) | | [60] [60]
Part. 1 † Part. 2 † 00-99 = entry delay 2 time for each
partition; 50 seconds max. for UL installations
*37 AUDIBLE EXIT WARNING [1] [1]
Part. 1 † Part. 2 † 0 = no; 1 = yes
*38 CONFIRMATION OF ARMING DING [0] [0]
Part. 1 † Part. 2 †
0 = no; 1 = yes (wired keypads and RF); 2 = yes, RF only
*39 POWER UP IN PREVIOUS STATE † [1]
0 = no; 1 = yes; “1” for UL installations
† Entry of a number other than one specified will give unpredictable results.
–3–
*49 SPLIT/DUAL REPORTING [0]
0 = Disable (Backup report only)
TO PRIMARY PHONE No. TO SECONDARY PHONE No.
1 = Alarms, Restore, Cancel Others
2 = All except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All
4 = All except Open/Close, Test All
5 = All All
TO PRIMARY PHONE No. TO PAGING No. * (Secondary)
** A 10-digit code is sent to the pager consisting 6 = All except Open/Close ** Alarms, Open/Close, Troubles
of a 4-digit subscriber number, a 3-digit event code, 7 = All reports ** Alarms, Troubles
and a 3-digit user or zone number. 8 = All reports * * Alarms, Open/Close, Troubles
See Installation Instructions for an explanation 9 = All except Open/Close * * A l a r ms , O p e n / Cl o s e f o r
of the 10-digit code. us ers 5-25 (us ers 5-16 or
wi r e l e s s b u t t o n z o n e s 1 0 -
2 5 ) , Tr o u b l e s
* Ca n o n l y b e u s e d i f p r i ma r y r e p o r t i n g f o r ma t i s A d e mc o Co n t a c t I D.
*50 15 SEC DIALER DELAY (BURG) † [0]
0 = no; 1 = yes; “0” for UL installations
*51 PERIODIC TEST REPORT † [0]
0 = none; 1 = 24 hours; 2 = weekly; 3 = 30 days (Enter Test
Code in field * 64. Reports with Partition 1 subscriber No.)
*52 TEST REPORT OFFSET † [2]
0 = 24 hour; 1 = 6 hours; 2 = 12 hours; 3 = 18 hours (Time to 1st
report from programming or downloading).
*53 SESCOA/RADIONICS SELECT [0]
0 = Radionics (0–9, B–F reporting); 1 = SESCOA (0–9 only
reporting). Select 0 for all other formats.
† Entry of a number other than one specified will give unpredictable results.
*56 ZONE ASSIGNMENT/ALARM REPORT CODES —This field is an interactive mode. Fill in the required
data on the worksheet below (and on next page) and follow the programming procedure in the installation
manual.
ZONES ON CONTROL: See explanation of headings on next page ·
ZONE ZONE ZONE PART'N ALARM RPT CODE INPUT
RESPONSE
DESCRIPTION No. TYPE No. (Hex) TYPE TIME
(Zn) (ZT) (P) (RC) (In) (RT)
Wired Zone 1* 0 1 HW
Wired Zone 2 0 2 HW
Wired Zone 3 0 3 HW
Wired Zone 4 0 4 HW
Wired Zone 5 0 5 HW
Wired Zone 6 0 6 HW
Wired Zone 7 0 7 HW
Wired Zone 8** 0 8 HW
Expansion Module 0 9 0 5 Both Ñ Ñ
Supervision
Duress 9 2 — — Both Ñ Ñ
Console Panic (1 & *, or A) 9 5 Both Ñ Ñ
Console Panic (3 & #, or C) 9 6 Both Ñ Ñ
Console Panic (* & #, or B) 9 9 Both Ñ Ñ
* Zone 1 can be used as a 2-wire Fire zone. **Zone 8 can be used as a Glassbreak zone.
–4–
EXPANSION ZONES: Assign zone numbers (Zn) 10–17 to 4219/4229 Auxiliary Wired Loops A–H, if used. ENTER FOR
RF zones can use zone numbers (Zn) 10–31 [
RF ONLY
[
ZONE ZONE ZONE PART'N ALARM RPT CODE INPUT LEARNED
DESCRIPTION No. TYPE No. (Hex) TYPEÊÊÊÊRF INPUT
(Zn) (ZT) (P) (RC) (In) (L)
4219/4229 Loop A 1st Exp'n Zone 1 0
or RF Zones B 1 1
C 1 2
D 1 3
E 1 4
F 1 5
G 1 6
H 1 7
RF Zones 1 8
1 9
2 0
2 1
2 2
2 3
2 4
2 5
RF Zones 2 6
2 7
2 8
2 9
3 0
3 1
3 2
3 3
–5–
TO PROGRAM SYSTEM STATUS, & RESTORE *75 RF XMTR LO BAT RST RPT CODE |
REPORT CODES (*59Ð*76, & *89):
*76 TEST RESTORE RPT CODE |
With a 3+1 or 4+1 Standard Format: Enter a code in the first
box: 1–9, 0, B, C, D, E, or F. Enter "#+10" for 0, "#+11" for B,
"#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F. OUTPUT AND SYSTEM SETUP (*80– *93)
A "0" ( not "#+10") in the first box will disable a report. *80 OUTPUT RELAYS AND Program only if
A "0" ( not "#+10") in the second box will result in auto matic
advance to the next field when programming. POWERLINE CARRIER Relays and/or
DEVICES Powerline Carrier
With an Expanded or 4+2 Format: Enter codes in both boxes devices are to be
(1st and 2nd digits) for 1–9, 0, or B–F, as de scribed above. *81 ZONE LISTS FOR OUTPUT used. See next page.
A "0" ( not "#+10") in the second box will eliminate the ex- DEVICES
panded message for that report.
A "0" ( not "#+10") in both boxes will disable the report. *82 CUSTOM ALPHA EDITING: (Also entered from field
With Ademco Contact ID Reporting: Enter any digit (other *56): See procedure in instructions.
than "0") in the first box, to enable zone to report (entries in the *83 SEQUENTIAL LEARN MODE (Also entered from
second boxes will be ignored). field *56): See procedure in instructions.
A "0" ( not "#+10") in the first box will disable the report.
*89 EVENT LOG 80% FULL RPT CODE |
Examples:
For Code 3 (single digit), enter: 3 | 0
*90 EVENT LOGGING [3]
For Code 3 2 (two digits), enter: 3 | 2 0 = None; 1 = Alarm/Alarm Restore;
2 = Trouble/Trouble Restore; 4 = Bypass/Bypass
For Code B 2 (Hexadecimal), enter: #+11 | 2 Restore; 8 = Open/Close.
Example: To select “Alarm/Alarm Restore”, and
SYSTEM STATUS REPORT CODES (*59– * 68) “Open/Close”, enter 9 (1 + 8); To select all, enter #15.
Default for all report codes = [00] Note: System messages are logged when any non-
zero selection is made.
*59 EXIT ERROR REPORT CODE
*91 OPTION SELECTION (AAV) [0]
*60 TROUBLE REPORT CODE | 0 = None; 4 = AAV;“0” for UL installations.
*92 PHONE LINE MONITOR ENABLE [0]
*61 BYPASS REPORT CODE |
0 = Not used
*62 AC LOSS REPORT CODE t | 1 = Keypad display when line is faulted
2 = Keypad display plus keypad trouble sound
*63 LOW BAT REPORT CODE t | 3 = Same as “2”, plus Device #2 STARTS. If either
partition is armed, external sounder activates also.
*64 TEST REPORT CODE | Note:Ê Device #2 must either be programmed to be
STOPPED in field *80 or STOPPED by Code + # + 8 + 2.
*65 OPEN REPORT CODE Part. 1 ††
*93 No. OF REPORTS IN ARMED PERIOD [0]
Part. 2 †† 0 = 10 Alarm/Alarm Restore Reports; 1 = Unlimited.
“1” for UL installations.
*66 ARM AWAY/STAY RPT CODE Part. 1 ††
AWAY STAY DOWNLOAD INFORMATION ( *94, *95)
Part. 2 †† *94 DOWNLOAD PHONE No.
AWAY STAY | | | | | | | | | | | | | | |
† 2nd digit is automatically sent as the 2nd digit of the
zone alarm report code programmed in * 56, if Enter up to 16 digits, 0–9; #+11 for '*'; #+12 for '#'; #+13 for
expanded or 4+2 report ing is selected. a pause. Do not fill unused spaces. If fewer than 16 digits
†† 2nd digit is automatically sent as the user number if entered, exit field by pressing * (and press 95, if entering
next field). To clear entries from field, press *94 *.
expanded or 4+2 reporting is selected.
Note: In UL installations, down loading may only be
*67 RF XMTR LOW BAT REPORT CODE | performed if a technician is at the site.
*95 RING DET COUNT FOR DOWNLOADING[0]
*68 CANCEL REPORT CODE |
0 = Disable Station Initiated Download; 1–14 = number
of rings (1–9, # +10 =10, # +11 =11, # +12 =12,
RESTORE REPORT CODES (*70– *76) # +13 =13, # +14 =14); 15 = answering machine defeat
Default for all restore report codes = [00] (# +15 =15)
Note: Do not enter “0” if using 4285 Voice Module.
*70 ALARM RESTORE RPT CODE
2nd digit is automatically sent as the 2nd digit of
*96 INITIALIZES DOWNLOAD ID, SUBSCRIBER
the zone alarm report code programmed in *56, if
expanded or 4+2 re porting is selected. ACCOUNT No. FOR INITIAL DOWNLOAD:
No data entry required.
*71 TROUBLE RESTORE RPT CODE |
*97 SETS ALL PROGRAM FIELDS TO DEFAULT
*72 BYPASS RESTORE RPT CODE | VALUES: No data entry required.
*98 Exits programming mode and prevents re-entry
*73 AC RESTORE RPT CODE t | by: Installer Code + 8+ 0 + 0. If *98 is used to
exit programming mode, system must be
*74 LOW BAT RESTORE RPT CODE t | powered down, and method 1 above used to
enter the programming mode.
t Reports with Partition 1 Subscriber No. *99 Exits programming mode and allows re-entry
by: Installer Code + 8 + 0 + 0 or: Power-up, then
press " *" and "#" within 50 seconds of power up.
–6–
OUTPUT RELAYS/POWERLINE CARRIER DEVICES WORKSHEET FOR *80, and *81.
Applicable only if Relays and/or Powerline Carrier Devicess are to be used.
80 OUTPUT DEVICES – This is an interactive menu mode. Fill in the required data on the worksheet on below and follow
*
the programming procedure in the installation manual as you enter the data during the displays and prompts that appear
in sequence.
Notes: 1. For Relays, field *25 must be programmed for a 4229 (Relays 01 and 02), OR for a 4204 (Relays 01 to 04).
2. For Powerline Carrier devices, field *27 must be programmed with a House Code.
3. Tampers of expansion units cannot be used to operate devices.
S T A R T S T O P
=either or both - ÊÊÊÊÊÊÊÊÊÊÊÊ= either or both -
ZONE ZONE TYPEÊÊPART'N RESTORE of ZONE TYPEÊÊÊÊPART'N
DEVICE ACTION EVENT LIST SYST OP'N No. ZONE LIST /SYST OP'N No. X-10
NUMBER (A) (EV) (ZL) ÊÊÊÊÊ(ZT) (P) (ZL) (ZT) (P) SELECT
OUTPUT RELAY
OR P.L.C.D.* 01
OUTPUT RELAY
OR P.L.C.D.* Ê02
OUTPUT RELAY
OR P.L.C.D.* Ê Ê03
OUTPUT RELAY
OR P.L.C.D.* ÊÊ04
P.L.C.D.* ÊÊÊÊÊÊÊÊ05
P.L.C.D.* ÊÊÊÊÊÊÊÊ06
P.L.C.D.* ÊÊÊÊÊÊÊÊ07
–7–
81
* ZONE LISTS FOR OUTPUT DEVICES – This is an interactive mode. Fill in the required data on the worksheet
below and follow the procedure in the installation manual as you enter the data during the displays and prompts that
appear in sequence.
Note: Record desired zone numbers below. More or fewer boxes than shown may be needed, since any list may
include any or all of system's zone numbers.
Zone List 3: Started or stopped by zone numbers AND/OR assignment of Chime zones (enter 00 to end entries)
, , , , , , , , , ...etc.
SPECIAL MESSAGES
OC = OPEN CIRCUIT (no communication between Console and Control).
EE or ENTRY ERROR = ERROR (invalid field number entered; re-enter valid field number).
After powering up, AC, dI (disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds. This
will revert to READY in appx. 1 minute, which allows PIRS, etc. to stabilize. To bypass this delay, press: [#] + [0].
If E4 or E8 appears, more zones than the expansion units can handle have been programmed. Correct the programming and
then completely de-power and re-power the control to clear this indication and remove the disable indication.
ALARM DE V I CE MANUFACTURI NG CO .
A DIVISION OF PITTWAY CORPORATION
165 Eileen Way, Syosset, New York 11791
Copyright © 1997 PITTWAY CORPORATION
àVISTA-20PRV4sä
VISTA-20PRV4 Rev B 4/99 (See Instructions N7526V4 Rev B)