SOLAR-XPLORE Datasheet

Portable heated FID VOC analyser

Uploaded by

gwarninz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

NEW

S4 SOLAR XPLORE
Portable heated FID VOC analyser

Flame Ionisation Detector (FID) analysers for the


discontinuous measurement of the mass concentration
of gaseous and vaporous organic substances in
stationary source emissions.

Flexible Easy to Use Accurate


Single or dual detectors Rugged and portable Precision monobloc heated FID

Integrated zero air generator Wireless tablet interface Simultaneous monitoring of THC,
NMHC & Methane
Software suite for use over Typical warm up 30 minutes
ethernet Fast response time

Rack mounted
FID for continuous
monitoring
S4 SOLAR XPLORE
SPECIFICATIONS
MEASUREMENT TEMPERATURE EFFECT ON FUEL CONSUMPTION REMOTE CONTROL
TECHNIQUE ZERO Single detector: AK protocol
Flame Ionisation Detector <0.15% per oC 35ml/min H2 or 180ml/min Ethernet
H2He Comes with S4i remote
MEASURING UNITS TEMPERATURE EFFECT ON Dual detectors: software operating system.
PPM or mg user selectable SPAN 70ml/min H2 or 360ml/min
<0.3% per oC H2He SIZE AND WEIGHT
MEASURING RANGES 252 (w) x 264 (h) x 494 (d) mm
Range A: 0-1000ppm. SAMPLE INLET PRESSURE AIR SUPPLY 14kg - 16kg
User settable to e.g. With internal sample pump: Single detector:
0-1ppm, 0-5ppm, 0-10ppm, -0.6 to +0.4bar <1.1L/min IP RATING
0-50ppm,0-100ppm, Without internal sample Dual detector: IP55
0-500ppm, 0-1000ppm. pump: <1.6L/min
Resolution:0.01ppm +0.2 to +0.5bar
Range B: 0-10000ppm. OPERATING CONDITIONS
User settable to e.g. 0-10ppm, ACCURACY 5-40oC ambient temperature NEW - Every S4 gas analyser
0-50ppm, 0-100ppm, <0.2% FSD can now be supplied with
0-500ppm, 0-1000ppm, OUTPUTS a rugged, wireless tablet
0-5000ppm. 0-10,000ppm. PRECISION 0-10 Vdc which connects wirelessly
Resolution: 0.1ppm <1% RS232 to the analyser via an
Range C. 0-100,000 ppm. Ethernet inbuilt 802.11 Wi-Fi that can
User settable, with resolution DETECTION LIMIT TCP/IP connect up to 50 metres
of 1ppm 0.05mgC/m3 Optional 4-20 mA away. This provides the
users with the ability to
RESPONSE TIME BYPASS FLOW SENSITIVITY POWER REQUIREMENTS view live data in a different
THC <1.5 secs Less than 2% from 100 to 250Vac location, and even manage
CH4 and NMHC <2.5 secs 1 to 3 L/min Optional 24VDC data logging, alarms and
600W max calibrations.
REPEATABILITY SAMPLE FILTER
<1% FSD Removable 0.4 micron PTFE
7um non removable stainless
OXYGEN EFFECT steel filter for CFID
<2% of reading from
0% to 21% WITH C3H8 DISPLAY
Blank or Detachable Screen
LINEARITY
± 0.5% FSD OR 2% of reading SAMPLE CONDITION
0-200oC (Heated version)
DRIFT 0-80oC non-condensing for
< ± 0.2ppm or ± 2% range CFID
whichever greater

NOISE
<0.05% FSD, THC & CH4
(EURO VII)

Authorised Representative:

Signal Group Ltd


Standards House, Doman Road, Camberley, Surrey GU15 3DF
United Kingdom

www.signal-group.com Tel: +44 (0)1276 682841 Email: [email protected]