Final Summary Report - 81V5
Final Summary Report - 81V5
External:
Name plate is found intact and readable.
This equipment is insulated. Minor cladding damage near Manway M1
was observed, however overall Insulation cladding condition found
satisfactory.
Grounding connection found in satisfactory condition.
Platform, ladders, gratings, Lifting Lugs and foundation found in
satisfactory condition.
Minor paint damage at lifting lugs was observed.
Internal:
NDT:
DPT was performed after mechanical cleaning on all internal weld joints
including seams, nozzles and internal attachments and no relevant
indication noticed and found as Accepted.
UT thickness performed for remaining bottom head TML and result found
Accepted.
SEI: Saud/M.Talha/Irfan.
A.1
A.2 Area: 81 Unit: MTBE
0
A.1
A.3 Tag Number: 81v5 Work Order No.: 960850597
1
A.1
A.5 SAP No. Vessel Material: CS – SA 516 Gr.60 (N)
3
A.1
A.8 Inspection Technique VT, DPT & UT. Insulation Type HOT
Used: 6
INSPECTION CHECKLIST (A = In Good Condition, B = Minor Problem Need Repair, C = Bad Condition Need
B.
Repair)
Verified
S/N Item Inspected Condition Action
Yes No N/A
1 SHELL
Shell and heads in good condition (no
1.01 corrosion pits, liquid/vapor interface corrosion, √ A
erosion marks, etc.)
Weld joints in good condition (no corrosion,
1.02
erosion, grooving or pitting) √ A
Any galvanic corrosion damage on areas of
1.03 shell, which are in contact with internals of √ A
dissimilar metallurgy
1.04 Ladder rungs in good condition √ A
1.05 Thick / hard process deposits inside shell √ A Recleaning Done
Bulges, dents or other deformation on shell /
1.06
heads √ A
1.07 Lining in good condition √ A
1.08 Cladding / overlay in good condition √ A
Verified
2 INTERNALS Condition Action
Yes No N/A
Internal distributor piping in good condition (no
2.01 corrosion, loose supports clamps, missing bolts √
/ gaskets, etc.)
Trays in good condition (no corrosion, thinning
2.02 or warpage & are securely installed on tray √
support rings)
Valves, sieves or bubble caps on trays in good
2.03
condition (no damages or missing valves/caps) √
Tray support rings, support grids and their
2.04 welds in good condition (no corrosion, thinning √
or other damages)
Bed limiter / hold down grid and their welds in
2.05 good condition (no corrosion / thinning, √
missing nut bolts, etc.)
2.06 Demister pad in good condition √
Support ring for demister pad & welds in good
2.07
condition √
Vortex breaker on bottom head in good
2.08
condition √
2.09 Packing in good condition √
2.10 Agitator shaft & blades in good condition √
Baffles / partition plates / support grids in good
2.11
condition √
3 NOZZLES, MANWAYS & COVER Verified
Yes No N/A Condition Action
Inside of all nozzles in good condition (no
3.01
corrosion / thinning or pitting) √ A
Classification: Internal Use
Verified
4 Refractory Condition Action
Yes No N/A
4.01 General physical condition of lining √
Sign of overheating or shrinkage or surface
4.02
degradation √
Wall bulging or tilting, separation from anchors
4.03
or substrate. √
Structural deterioration, soundness and
4.04 strength of lining (e.g., hammer test for voids, √
laminations)
4.05 Cracks and typical width, length √
Expansion joint condition & filling materials or
4.06
penetration catalyst inside expansion gaps √
4.07 Open joints or gaps √
4.08 Condition of construction joints √
4.09 Surface spalling (loss of surface layer) √
Surface erosion / Overheating & glazing on
4.10
surface / devitrification √
Thickness reduction/ internal dimensional
4.11
checking for suspected location √
Fallen or lose of refractory layer /
4.12 Refractory bricks and tiles missing/ sagging/ √
displacement
Melting and formation of a hard glassed
4.13
surface (e.g., fluxing or slagging) √
4.14 Chemical attack, corrosion or condensation √
Visible anchor tips, exposures of anchors/
4.15
support & deteriorations √
Condition of Hex-mesh, S-bar anchors for thin
4.16
linings √
Deposition of foreign materials on surface or
4.17
surface build-up √
4.18 Softening of the hot face or soft surface √
4.19 Color changes of wall √
Lining in and around nozzles, manholes,
4.20
burners, openings √
4.21 Condition of back-up insulation layer √
Refractory pieces or debris on floor or catalyst
4.22
bed, if any and locations √
Bulging / tilting/ displacement of wall, Contour
4.23
of lining (Verticality & horizontality of wall) √ A
Condition of mortar joints and gaps between
4.24
bricks √
Classification: Internal Use
5 Inspection Findings
C. INSPECTION RECOMMENDATIONS:
C.1 Permanent Repair
Notification
Rec # Description Target Date Priority
#
D. ATTACHMENTS:
1 MOC Package for Temproray Repair(Sample)
2 Risk Assessment (Sample)
3 Other Reports (Sample)
Date:
Reviewd By: (Inspection
Engineer – Site / Manger – Site )
F. PHOTOGRAPHS:
Identification: Identification:
Description: Description:
Classification: Internal Use
Identification: Identification:
Description: Description: