OPEK365 Operating Manual (V3.00)
OPEK365 Operating Manual (V3.00)
, LTD
Catalog
Part 1 Overview......................................................................................................................3
1、Attention.............................................................................................................. 3
2、Warning............................................................................................................... 3
3、Prohibition........................................................................................................... 4
1、Machine parameter............................................................................................ 7
2、Actuator angle................................................................................................... 8
1、Actuator test.................................................................................................... 10
3、Alarm test.......................................................................................................... 12
1、Machine file....................................................................................................... 16
2、Density File....................................................................................................... 17
3、Chain file........................................................................................................... 18
4、Pattern file.........................................................................................................19
3、Action edit......................................................................................................... 22
Part 1 Overview
1、Attention
1.This machine used by the power of the power supply that limited to nameplate indicating
type. When the actual power more than plus or minus 10% , Machine should be equipped with
corresponding power regulator
2.The wire of power supply should be well fixed and necessary safety protection in strict
accordance with Power Industry Standard .The wire can not bear the force.
3.To ensure the machine`s working air pressure shall not be less than 6kg/cm², or else will
cause the valve abnormal operation.
4.The equipment must grounding . If there is no ground wire may cause the operator to get an
electric shock , and at the same time also can effect the normal running of the machine.
5.Repairing and debugging the electrical components ,please try to contact the professional
engineer, unprofessional operation will affect the performance of the equipment as well as the
failure rate .
6.In the process of using this equipment , please do not open the power control cabinet .
Because of some components with high voltage,threat personal safety .
7.Check the fuse of equipment periodically , and in accordance with the machine
specifications to replace the damaged fuse .
8.When the U-Disk read and write data , please don`t pull out the U-Disk . Or else will
damage and lost the data .
9.This equipment should work in a dry and ventilated environment , please regularly cleaning
the dust on the surface of the equipment .
10.Users should be in strict accordance with the instructions of the this manual . If there is
any inaccuracy , please contact our technical services in time .
2、Warning
1.When do the daily maintenance and debugging that need to open the control box , please
make sure the power disconnect in advance at least one minute before operation.
2.Please don`t use the component that is not our company provided, or else all the damage
should be borne by the customer.
3、Prohibition
1.When the normal operation of the machine, please don`t touch any running parts .
2.If machine`s protecting cover is defective or damaged . It is banned to use until repair or
replace it .
3.It is prohibit when machine works in the following conditions , Moisture ,Dust ,Corrosive
gas, Flammable and explosive gas .
4.It is forbidden to directly input and output circuit of controller insulation test , or else will
cause damage of electrical components.
F1-F8:Function keys.
0-9:Number keys.
Enter:Enter key.
Esc:Cancel and exit key.
WORK PROG:Work and Program switch.
Off(Light off): Programming interface. In this interface, you can modify the
parameters and test the hardware.
On(Light on): Knitting interface. In this interface, the machine can weave products.
JOG:Jog switch. Effective in knitting interface.
RUN:Run switch. Effective in knitting interface.
STOP:Stop switch. Effective in knitting interface.
Emergency stop:In emergency, the emergency stop switch on the left side of the
machine can force to stop the machine.
1、Machine parameter
Enter the ‘sys setup” interface, display the machine parameters interface. As shown in figure
3.3.
Key description:
0-9:Number keys. Please press the “Enter” to complete the input.
Esc:Enter the error or want to cancel the input, press the key to cancel the operation.
Enter:When the input is completed , press the key to confirm.
Parameter description:
1.1 Mac Needle:Number of needles for the machine.
1.2 Oil Time:Set the pump oil time,when oil pump auto oiling .
1.3 Oil Interval:How many products, the pump will work.
1.4 Overlap:Number of needles in the main yarn at the same time.
1.5 PAT Move<L>:In the knitting process, the number of needles that move to left.
1.6 PAT Move<R>:In the knitting process, the number of needles that move to right.
1.7 Blower Time:Effective when the blower is set “automatic”.When the machine is stop,
how much time the blower is stop work.
1.8 Density<1>:Invalid.
1.9 Density<2>:Invalid.
1.10 Max Speed:Maximum speed of the machine.
2、Actuator angle
In general, "Actuator01" is 0 degrees. Other parameters are set according to the actual
angle .The effective value is 0-360. As shown in figure 3.4
Key description:
0-9:Number keys. Please press the “Enter” to complete the input.
Esc:Enter the error or want to cancel the input, press the key to cancel the operation.
Enter:When the input is completed , press the key to confirm.
Note:
This parameter must be strictly in accordance with the data,that provided by the
manufacturers. Otherwise, the machine jacquard pattern will be error and may be
damage the jacquard needle.
1、Actuator test
Enter the testing interface of actuator, following the step “Main menu → Test→ Actuator ” .
As shown in figure 3.6.
3、Alarm test
Following the step “Main menu→Test→Alarm Test” to enter the alarm test interface . As
shown in figure 3.8 .
When a certain part is malfunction . The corresponding light will be lit at the same time.
Scissors Motor:When the motor is tested, the motor will rotate in a fixed direction.
Density Motor:When the motor is tested, the motor will rotate forward and reverse.
Attention:
When the density motor is tested, the zero signal of the corresponding motor is input,
that is, the indicator lamp of the zero position signal probe has been lit. System to determine
the motor is always on the 0 degree. So the test output is always wrong. Motor test will be
error. Please check:
Whether the motor is stuck.
Whether the zero signal is normal.
1、Machine file
Following the step “Main Menu→File Manage→Mac File” to enter the machine file
management interface . As shown in figure 3.12 .
Machine file’s suffix for "MTR" . According to the actual parameters of the machine, each
machine can only have one machine file. As shown in figure 3.12. Machine file list on the left.
The right for the U disk file list.
Insert U disk and U disk system with the corresponding file, U disk file list will be effective.
2、Density File
Following the step “Main Menu→File Manage→Den File” to enter the density file
management interface . As shown in figure 3.13 .
Density file’s suffix for "MAG" . According to the actual parameters of the machine, each
machine can only have one density file. As shown in figure 3.13. Density file list on the left. The
right for the U disk file list.
Insert U disk and U disk system with the corresponding file, U disk file list will be effective.
3、Chain file
Following the step “Main Menu→File Manage→Chain File” to enter the chain file
management interface . As shown in figure 3.14 .
Chain file’s suffix for "CAT" . As shown in figure 3.14.Chain file list on the left. The right
for the U disk file list.
Insert U disk and U disk system with the corresponding file, U disk file list will be effective.
4、Pattern file
Following the step “Main Menu→File Manage→Pat File” to enter the pattern file
management interface . As shown in figure 3.15 .
Chain file’s suffix for "MOF" . As shown in figure 3.15.Pattern file list on the left. The right
for the U disk file list.
Insert U disk and U disk system with the corresponding file, U disk file list will be effective.
Option description:
PU PgUp:When the file list exceeds the display interface, press this button to page up
the file list.
PD PgDn:When the file list exceeds the display interface, press this button to page
down the file list.
EN Edit:Enter the editing interface for the selected file.
F1 Add:Add a new chain file.
3、Action edit
Following the step “Main Menu→Chain Edit” to enter the chain edit interface . Select the
files you need to edit, and then press the “Enter” key to enter the interface. Then select the step
you need to edit, press the “Enter” key to enter action edit interface. As shown in figure 3.18.
Option description:
PU PgUp:When the file list exceeds the display interface, press this button to page up
the file list.
PD PgDn:When the file list exceeds the display interface, press this button to page
down the file list.
F7 Add:Add the code, prompted "Are you sure to add ?". Press the "Enter" key on the
keyboard to add, "Esc" key to cancel.
F8 Delet:Delete the code, prompted "Are you sure to delete ?". Press the "Enter" key on
the keyboard to delete, "Esc" key to cancel.
0-9:Number keys. Please press the “Enter” to complete the input.
Esc:Enter the error or want to cancel the input, press the key to cancel the operation.
Enter:When the input is completed , press the key to confirm.
Knitting information:
Target output:Target production quantity. When the quantity is full, the machine will be
stop automatically.
File information:
Knitting time:
9 Function key
Note:
When the machine is stopped, the function key is valid.
www.opek-textiles.com email : [email protected] Tel: 0086-551-68778836
OPEK365 Fully Computerized Cap Control System Operating Instruction
Note:
When the machine is stopped, the function key is valid.
Note:
When the machine is stopped, the function key is valid.
Note:
When the machine is stopped, the function key is valid.
Option description:
0-9:Number keys. Please press the “Enter” to complete the input.
Esc:Enter the error or want to cancel the input, press the key to cancel the operation.
Enter:When the input is completed , press the key to confirm.
Note:
When the machine is stopped, the function key is valid.
Option description:
0-9:Number keys. Please press the “Enter” to complete the input.
Esc:Enter the error or want to cancel the input, press the key to cancel the operation.
Enter:When the input is completed , press the key to confirm.
Note:
When the machine is stopped, the function key is valid.
Note:
www.opek-textiles.com email : [email protected] Tel: 0086-551-68778836
OPEK365 Fully Computerized Cap Control System Operating Instruction
4 Depict edge You can draw the outline of the color inside or outside.。