Fault Code Sumitomo - 1241
Fault Code Sumitomo - 1241
0107 Atmospheric Pressure Sensor Circuit Abnormality (abnormally low voltage) 0107
0108 Atmospheric Pressure Sensor Circuit Abnormality (abnormally high voltage) 0108
0112 IAT (intake air temperature) Sensor Abnormality (abnormally low voltage) 0112
0113 IAT (intake air temperature) Sensor Abnormality (abnormally high voltage) 0113
0117 ECT (engine coolant temperature) Sensor Abnormality (abnormally low voltage) 0117
0118 ECT (engine coolant temperature) Sensor Abnormality (abnormally high voltage) 0118
0182 FT (fuel temperature) Sensor Abnormality (abnormally low voltage) 0182
0183 FT (fuel temperature) Sensor Abnormality (abnormally high voltage) 0183
0192 Common Rail Pressure Sensor Abnormality (abnormally low voltage) 0192
0193 Common Rail Pressure Sensor Abnormality (abnormally high voltage) 0193
0201 No 1 Cylinder Injector Drive System Disconnection 0201
0202 No 2 Cylinder Injector Drive System Disconnection 0202
0203 No 3 Cylinder Injector Drive System Disconnection 0203
0204 No 4 Cylinder Injector Drive System Disconnection 0204
7023 アーム閉圧力センサ異
7040 燃料センサ異常
7041 油温センサ異常
7045 モニタサーミスタ異常
7060 ブーム角度センサ異常
7061 アーム角度センサ異常
7062 オフセット角度センサ
7063 リターンフィルタ目詰まりSW異常
7064 燃料密度センサ異常
7200 旋回ブレーキSOL異常
7201 走行2速SOL異常
7202 昇圧SOL異常
7203 走行アラーム異常
7204 パワーセーブSOL異常
7205 給油ポンプリレー異常
7206 予備ライン切り替えSOL
7207 フリースイングSOL異常
7208 ファン反転SOL異常
7209 エアコン水温送信異常
7210 クレーンブザー異常
7211 パトライト&バケットロ
7212 ゲートロックSOL異常
7240 馬力比例弁異常
7241 流量比例弁異常
7242 ファン比例弁異常
7243 ブーム比例弁異常
7244 アーム比例弁異常
7245 オフセット比例弁異常
7400 水温オーバーヒート1
7401 水温オーバーヒート2
7402 水温オーバーヒート3
7404 油温オーバーヒート
7405 ブースト温オーバーヒート1
7406 ブースト温オーバーヒート2
7420 オルタネータ発電不良
7421 クーラントレベル低下
7422 エンジンオイル圧低下
7423 エアクリーナ目詰まり
7424 リターンフィルタ目詰ま
7425 燃料密度エラー
7600 CANバス異常
7601 モニタ通信異常
7602 ECM通信異常
7603 コントローラS通信異常
7604 コントローラB通信異常
7605 ECMミスマッチ
7606 EEPROM異常
Engine DTC list on the last machine computer program
For LBX
PSM
Yes
Yes
Yes
Yes
Yes-OPT
Yes-OPT
Yes-OPT
Yes
Yes
Yes
Yes for LM
Yes for LM
Yes for LM
Yes-OPT
No need
Yes
Yes
Yes
Yes
Yes
No need "Not appeared" means that DTC was assigned, but there is no actual program to be appeared the DTC.
No need "Not appeared" means that DTC was assigned, but there is no actual program to be appeared the DTC.
No need "Not appeared" means that DTC was assigned, but there is no actual program to be appeared the DTC.
No need "Not appeared" means that DTC was assigned, but there is no actual program to be appeared the DTC.
Yes
No need
No need
Yes for LM
Yes
Yes
Yes
Yes for LM
Yes for LM
No need
Yes
Yes
Yes
No need
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes-OPT
No need
Yes
Yes
Yes
No need
Yes for LM
Yes
Yes
Trauble shooting sumitomo excavator
7210 — Crane
7400.7402.7403– temperature
7404– oil
7421– level
7600 — CAN
7601– monitor communications
7605 — ECM
7606 — EEPROM
Fault location fault codes determine the timing of the failure mode occurred prerequisite
judgment recovery judgment
P1 pressure sensor GND short / open 7000 ○ ignition switch is turned from no voltage ≦ 0.25
V 0.25 V <voltage <4.75 V
Pressure sensor P2 GND short / open 7001 ○ ignition switch is turned from no voltage ≦ 0.25
V 0.25 V <voltage <4.75 V
N1 pressure sensor GND short / open 7002 ○ ignition switch is turned from no voltage ≦ 0.25
V 0.25 V <voltage <4.75 V
N2 pressure sensor GND short / open 7003 ○ from the ignition switch is turned on without
voltage ≦ 0.25 V 0.25 V <voltage <4.75 V
Overload pressure sensor GND short / open 7004 ○ Select the applicable regional EU voltage
from the ignition switch is turned ≦ 0.25 V 0.25 V <voltage <4.75 V
Bottom pressure sensor GND short / open 7005 ○ choose a crane voltage ≦ 0.25 V 0.25 V
<voltage <4.75 V from the ignition switch is turned
Pressure sensor GND link short / open 7006 ○ choose a crane voltage ≦ 0.25 V 0.25 V
<voltage <4.75 V from the ignition switch is turned
The upper part of the body’s pressure sensor GND short / open 7020 ○ ignition switch is
turned from no voltage ≦ 0.25 V 0.25 V <voltage <4.75 V
Rotary Pressure Sensor GND short / open 7021 ○ ignition switch is turned from no voltage ≦
0.25 V 0.25 V <voltage <4.75 V
Supply short-circuit voltage ≧ 4.75 V
Walking pressure sensor GND short / open 7022 ○ ignition switch is turned from no voltage ≦
0.25 V 0.25 V <voltage <4.75 V
Arm off pressure sensor GND short / open 7023 ○ from the ignition switch no voltage ≦ 0.25
V 0.25 V <voltage <4.75 V
Fuel oil level sensor open from 7040 ○ no resistance after the ignition is turned ≧ 100Ω 2 Ω
<resistance <100 Ω
Short-circuit resistance ≦ 2 Ω
Oil temperature sensor open 7041 ○ 3 minutes after the engine is started without resistance ≧
67200Ω (voltage ≧ 4.93 V) 111Ω <resistance <67200 Ω 0.5 V <voltage <4.93V)
Short circuit from the ignition switch is turned resistance ≦ 111Ω (voltage ≦ 0.5 V)
Monitor thermistor (* 1) Open 7045 × no receipt from the ignition switch is turned fault bit is
not received from the monitor from the monitor’s fault bit
Short circuit
Boom angle sensor GND short / open 7060 ○ choose a crane or anti-interference voltage ≦
0.2 V 0.2 V <voltage <4.8 V from the ignition switch is turned
Arm angle sensor GND short / open 7061 ○ choose a crane or anti-interference voltage ≦ 0.2
V 0.2 V <voltage <4.8 V from the ignition switch is turned
Deviation angle sensor GND short / open 7062 ○ choose a crane or anti-interference voltage ≦
0.2 V 0.2 V <voltage <4.8 V from the ignition switch is turned
Back to the oil filter clogging pressure switch open after 7063 ○ from the ignition switch is
turned to the front of the engine start without pressure switch off pressure switch open
Show “×” the project is not “abnormal electrical system” message. In addition, users no longer
DTC screen display. However, DTC recorded in the maintenance screen (DIAG) in.
Rotary brake solenoid valve open from 7200 ○ no output after the ignition is turned ≠ Output
Monitor Output = Output Monitor
Short circuit
Walking speed solenoid valve open from 7201 ○ no output after the ignition is turned ≠ Output
Monitor Output = Output Monitor
Short circuit
7202 ○ boost solenoid valve open after the ignition is turned from no output ≠ Output Monitor
Output = Output Monitor
Short circuit
BZ walking alarm (* 1) Open 7203 × after turning the ignition switch from no output ≠ Output
Monitor Output = Output Monitor
Short circuit
7204 ○ saving solenoid valve open after the ignition is turned from no output ≠ Output Monitor
Output = Output Monitor
Short circuit
REL Open 7205 ○ charge pump stops after the ignition is turned from no output ≠ Output
Monitor Output = Output Monitor
Short circuit
Spare oil return circuit from the solenoid valve open 7206 ○ no output after the ignition is
turned ≠ Output Monitor Output = Output Monitor
Short circuit
Swing open from the solenoid valve open 7207 ○ no output after the ignition is turned ≠ Output
Monitor Output = Output Monitor
Short circuit
Fans reverse solenoid valve open from 7208 ○ no output after the ignition is turned ≠ Output
Monitor Output = Output Monitor
Short circuit
Air conditioning temperature signal output (* 1) Open 7209 × from the ignition switch is turned
on no output ≠ Output Monitor Output = Output Monitor
Short circuit
BZ cranes open after 7210 ○ no output from the ignition switch is turned ≠ Output Monitor
Output = Output Monitor
Short circuit
REL rotating lights and lock open 7211 ○ bucket from the ignition switch is turned on no output
≠ Output Monitor Output = Output Monitor
Short circuit
Lock rod from the solenoid valve open 7212 ○ no output after the ignition is turned ≠ Output
Monitor Output = Output Monitor
Short circuit
Pump output proportional valve open without current ≦ 30 mA 30 mA after 7240 ○ engine
start <current <3 A
Pump flow proportional valve open without current ≦ 30 mA 30 mA after 7241 ○ engine start
<current <3 A
After the fan proportional valve open 7242 ○ engine start no current ≦ 30 mA 30 mA <current
<3 A
After the big boom proportional valve open 7243 ○ engine start no current ≦ 30 mA 30 mA
<current <3 A
After the arm proportional valve open 7244 ○ engine start no current ≦ 30 mA 30 mA <current
<3 A
Deviation proportional valve open after the engine starts 7245 ○ no current ≦ 30 mA 30 mA
<current <3 A
Fault location fault codes determine the timing of the failure mode occurred prerequisite
judgment recovery judgment
Abnormally high temperature 1 7400 ○ one minute after starting the engine coolant
temperature sensor = normal CAN communication = normal ECM5 V supply voltage = normal
temperature ≧ 105 ℃ temperature <105 ℃
7404 ○ abnormal high temperature oil 1 minute after starting the engine oil temperature
sensor = normal oil temperature ≧ 95 ℃ temperature <95 ℃
Abnormally high temperature pressurized backward 1 7405 ○ supercharged engine start one
minute after the last-air temperature sensor = normal CAN communication = normal ECM5 V
supply voltage = normal pressurized air temperature ≧ 80 ℃ backward backward pressurized
air temperature ≦ 70 ℃
No abnormal voltage, low voltage AC motor 7420 ○ 10 seconds after starting the engine
pressure ≦ 10 V power generating pressure> 10 V
Coolant level is too low 7421 ○ no level switch is open level switch off the ignition switch is
turned from
Low engine oil pressure after 7422 ○ abnormal engine start 30 seconds oil pressure sensor =
normal CAN communication = normal ECM5 V supply voltage = normal pressure ≦ 40 kPa
pressure> 10 40 kPa
Air filter clogged 7423 ○ 10 seconds after starting the engine without vacuum switch on the
vacuum switch off
Back to the oil filter clogged 7424 ○ 10 seconds after starting the engine oil filter pressure
switch back to normal pressure switch off pressure switch open
CAN Bus Bus after 7600 ○ unusual open bus from the ignition switch without disconnecting or
passive failure condition is not satisfied
Abnormal condition monitor communications receiver after the ignition switch from 7601 ○ no
monitor is not open packets sent occurring not established
Conditions for receiving information packets sent Exception Monitor error occurred is not
established
Communication ECM timeout 7602 ○ condition after the ignition is turned from no information
has not issued ECM does not hold
Controller B Communications timeout 7603 ○ Choose from the ignition switch is turned on
there is a crane or anti-interference controller B information has not issued condition is not
satisfied
Conditions controller S communication timeout after 7604 ○ opened from the ignition switch S
does not send a message without a controller not established occur
ECM mismatch 7605 ○ 10 seconds after starting the engine models only select models ≠ ECM
calibration number invariably reply
EEPROM data anomalies 7606 × from the ignition switch is turned on without the last store to
check ≠ The calculation checks and store the last inspection = The calculation checks and
Show “×” the project is not “abnormal electrical system” message. In addition, users no longer
DTC screen display. However, DTC recorded in the maintenance screen (DIAG) in.