0% found this document useful (0 votes)
21 views11 pages

Shien

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views11 pages

Shien

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

REPUBLIC OF THE PHILIPPINES

N PROVINCE OF SOUTHERN LEYTE


CITY ENGINEER'S OFFICE
MAASIN CITY, SOUTHERN LEYTE

RECOMMENDING APPROVAL:

W E

4.34
5 . 0
0 M
E T
1 E R
S R O
A D
THIS SITE 8.77 R I G
H T
O F

1
2.50 W A

2
Y

4
PERSPECTIVE

5
A
1.50

3.00 13.50

3.50

BED
ROOM
3.50
3.50

KITCH
2.00

DINNIN
4
B
SCALE: 1:50 M.

EN

G AR

LIVING
7.00

AREA
2

EA

A
EA AR
3.50

BED
3.50

SHOW ON

ENTR
COMM

BED
ROOM
C

ER RM

Y PO
ROOM

BED
3

RCH
3.85

.
7.00

ROOM
2

B
3

1
1.50

5 3.00 3.50

3.50

13.50 3.50

2.00

5.00M
3.14
LOT 5426 (PORTION)
RAY O. ESPINOSA

TERS E
4
LINE BEARING DIST. (m)

ROAD
1-2 S 77°06'E 56.34

SITE DEVELOPMENT PLAN

RIGH
2-3 S 33°56'E 04.38
SCALE: 1:500 M.
3-4 S 09°13'W 16.90

T OF
VICINITY MAP
DRAWN NOT TO SCALE 4-5 N 76°20'W 57.58

5-1 N 05°51'E 19.33

CIVIL ENGINEER SEAL: PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO.
REG. NO.: * PERSPECTIVE
CONSTRUCTION OF ONE STOREY
A
1
DATE: MR. & MRS. JANICE R. MONTE DE RAMOS * SITE DEVELOPMENT
PTR. NO.: BUILDING OWNER PLAN
* LOCATION PLAN
DATE: LOCATION: BARANGAY BAGTICAN, MAASIN CITY, LOCATION: BARANGAY BAGTICAN, MAASIN CITY, * TECH. DESCRIPTION
1
TIN: SOUTHERN LEYTE SOUTHERN LEYTE 6
N
9.00

4.50 4.50
1.00

A B C

1.00
A-A
W E
7.00

3.50 3.50

S
1 COMMON
1

1.50

1.50
BED ROOM 4 SHOWER RM.

FF - 02 FF - 03

BUILDING AREA
BED ROOM 3
SPACE KITCHEN AREA

3.00

3.00
FF - 02
FF - 01
ENTRY PORCH
LIVING AREA

12.50
2 2

15.50

15.50
DINING AREA
DINNING AREA
KITCHEN AREA BED ROOM 2
3.50

3.50
B-B FF - 01
13.50

13.50
FF - 02
BEDROOM 01
BEDROOM 02
3 3
BEDROOM 03
BEDROOM 04 LIVING AREA
BED ROOM 1
3.50

3.50
COMMON SHOWER ROOM FF - 01
FF - 02

TOTAL FLOOR AREA


4 4
ENTRY PORCH
2.00

2.00

2.00
FLOOR FINISH SCHEDULE
5 5
FF - 01 60 x 60 CERAMIC TILES 3.50 3.50

7.00

9.00
FF - 02 45 x 45 CERAMIC TILES
FLOOR PLAN ROOF PLAN
FF - 04 30 x 30 NON SKID TILES SCALE: 1:110M. SCALE: 1:130M.

CIVIL ENGINEER SEAL: PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO.
REG. NO.: BUILDING AREA
CONSTRUCTION OF ONE STOREY
A
2
DATE: MR. & MRS. JANICE R. MONTE DE RAMOS FLOOR FINISH SCHED.
BUILDING FLOOR PLAN
PTR. NO.: OWNER
ROOF PLAN
DATE: LOCATION: BARANGAY BAGTICAN, MAASIN CITY, LOCATION: BARANGAY BAGTICAN, MAASIN CITY, 2
TIN: SOUTHERN LEYTE SOUTHERN LEYTE 6
9.00

4.50 4.50
0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70

1.00
FULL TRUSS

PURLINS 3" x 2" x 12'


GOOD LUMBER @ 0.70M

4.50
FULL TRUSS
PURLINS

PURLINS

PURLINS

PURLINS

PURLINS

PURLINS

PURLINS

PURLINS

PURLINS

PURLINS

PURLINS

PURLINS
13.50

3.50
FULL TRUSS

RAFTER 6" x 2" x 10'


GOOD LUMBER
3.50

(SEE RAFTER DETAIL)

0.70

0.70
FULL TRUSS
3.00
0.70
1.00

1.00

0.70

PURLINS 3" x 2" x 12'


ROOF FRAMING PLAN GOOD LUMBER @ 0.60M

1.00 3.50 3.50 1.00


SCALE: 1:130M.
9.00

FROM THE OFFICE OF: APPROVED BY: SEAL: PROJECT TITLE: APPROVED AS TO PLANS & LOCATION: SHEET CONTENTS: SHEET NO.
REG. NO.: ROOF FRAMING PLAN
CONSTRUCTION OF ONE STOREY
A
3
DATE: MR. & MRS. JANICE R. MONTE DE RAMOS
PTR. NO.: BUILDING OWNER
DATE: LOCATION: BARANGAY BAGTICAN, MAASIN CITY, LOCATION: BARANGAY BAGTICAN, MAASIN CITY, 3
TIN: SOUTHERN LEYTE SOUTHERN LEYTE 6
A B C 5 4 3 2 1

7.00 13.50

3.50 3.50 2.00 3.50 3.50 4.50

APEX
APEX

1.46
1.46

TOP OF THE BEAM

5.21
5.21

3.00
3.00

FLOOR LINE
FLOOR LINE

0.75
0.75

NGL
NGL

FRONT VIEW RIGHT SIDE VIEW


SCALE: 1:100 M. SCALE: 1:100 M.

C B A 1 2 3 4 5

13.50
7.00
4.50 3.50 3.50 2.00
3.50 3.50

APEX
APEX

1.46
1.46

TOP OF THE BEAM


TOP OF THE BEAM

5.21
5.21

3.00
3.00

FLOOR LINE
FLOOR LINE
0.75
0.75

NGL
NGL

REAR VIEW LEFT SIDE VIEW


SCALE: 1:100 M. SCALE: 1:100 M.

FROM THE OFFICE OF: APPROVED BY: SEAL: PROJECT TITLE: APPROVED AS TO PLANS & LOCATION: SHEET CONTENTS: SHEET NO.
REG. NO.: FRONT VIEW
CONSTRUCTION OF ONE STOREY
A
4
DATE: MR. & MRS. JANICE R. MONTE DE RAMOS REAR VIEW
RIGHT SIDE VIEW
PTR. NO.: BUILDING OWNER LEFT SIDE VIEW
DATE: LOCATION: BARANGAY BAGTICAN, MAASIN CITY, LOCATION: BARANGAY BAGTICAN, MAASIN CITY, 4
TIN: SOUTHERN LEYTE SOUTHERN LEYTE 6
5 4 3 2 1

13.50
2.00 3.50 3.50 4.50

APEX

SEE ROOFING DETAIL D D D


01 02 03
5.21

FLOOR LINE
0.75

FILLING MATERIALS FILLING MATERIALS FILLING MATERIALS


NGL

SECTION A - A
SCALE: 1:100 M.

A B C

7.00
3.50 3.50 W W
01 02

APEX
1.46

TOP OF THE BEAM SEE ROOFING DETAIL


5.21
3.00

FLOOR LINE

SCHEDULE OF DOORS AND WINDOWS


0.75

FILLING MATERIALS FILLING MATERIALS


NGL

SCALE: 1:70 M.
SECTION B - B
SCALE: 1:100 M.

FROM THE OFFICE OF: APPROVED BY: SEAL: PROJECT TITLE: APPROVED AS TO PLANS & LOCATION: SHEET CONTENTS: SHEET NO.
REG. NO.: SECTION A - A
CONSTRUCTION OF ONE STOREY
A
5
DATE: MR. & MRS. JANICE R. MONTE DE RAMOS SECTION B - B
SCHEDULE OF DOORS &
PTR. NO.: BUILDING OWNER WINDOWS
DATE: LOCATION: BARANGAY BAGTICAN, MAASIN CITY, LOCATION: BARANGAY BAGTICAN, MAASIN CITY, 5
TIN: SOUTHERN LEYTE SOUTHERN LEYTE 6
PURLINS
2" x 3" 10' Good Lumber

0.57
0.70
0.70
0.70

2.90
RAFTER

1.40
2" x 6" 10' Good Lumber

WOODEN POST
4" x 4" 6' Good Lumber

RAFTER DETAIL
SCALE: 1:30 M.

KING POST PURLINS


5 4.8
2" x 6" x 10' Good Lumber 2" x 3" 12' Good Lumber
4.8 5
WEB MEMBERS
2" x 6" x 12' Good Lumber TOP & BOTTOM CHORD
2" x 6" 12' Good Lumber

0.80 0.90 0.90 0.90 0.90 0.90 0.90 0.80


7.00

TRUSS DETAIL
SCALE: 1:50 M.

FROM THE OFFICE OF: APPROVED BY: SEAL: PROJECT TITLE: APPROVED AS TO PLANS & LOCATION: SHEET CONTENTS: SHEET NO.
REG. NO.: TRUSS DETAIL
CONSTRUCTION OF ONE STOREY
A
6
DATE: MR. & MRS. JANICE R. MONTE DE RAMOS RAFTER DETAIL

PTR. NO.: BUILDING OWNER


DATE: LOCATION: BARANGAY BAGTICAN, MAASIN CITY, LOCATION: BARANGAY BAGTICAN, MAASIN CITY, 6
TIN: SOUTHERN LEYTE SOUTHERN LEYTE 6
7.00 7.00 CHB WALL REINFORCEMENT:
VERTICAL BARS : 10mmØ @ 400mm O.C.
HORIZONTAL BARS: 10mmØ FOR EVERY
3.50 3.50 3.50 3.50 3 LAYERS of CHB

F1C1 wf F1C1 wf F1C1 F1C1 10MM Ø VERTICAL BARS 10MM Ø VERTICAL BARS
RB250m x 250m RB250m x 250m SPACED @ 400MM O.C. SPACED @ 400MM O.C.
COLUMN VERTICAL BARS
(SEE COLUMN SCHEDULE) SLAB ON GRADE SLAB ON GRADE
10MM Ø TIES SPACED @:
1.50

1.50
wf wf 4@50MM, 3@75MM, 2@100MM N.G.L.
REST @ 150MM O.C. TO CL
NATURAL GRADE LINE 3 - 10MM Ø 3 - 10MM Ø

RB250m x 250m

RB250m x 250m

RB250m x 250m
TEMP. BARS TEMP. BARS
DOWEL BARS TO DOWEL BARS TO
MATCH CHB VERT. BARS MATCH CHB VERT. BARS

4.50
FILL FILL
wf wf

3.00
3.00

3.00
12MM Ø MAIN FOOTING 12MM Ø MAIN FOOTING
BARS @ 200MM O.C. BARS @ 200MM O.C.

wf wf
RB250m x 250m RB250m x 250m
F1C1 F1C1 F1C1
100MM THICK GRAVEL BED
TYPICAL WALL FOOTING DETAIL
SECTION

RB250m x 250m

RB250m x 250m

RB250m x 250m
SCHEDULE OF REINFORCED CONCRETE COLUMNS

3.50

3.50
3.50

wf wf 3.50

13.50

13.50
13.50

13.50
MARK DETAILS
"N1" MATTING BARS
SEE FOOTING SCHEDULE
wf wf
RB250m x 250m RB250m x 250m
F1C1 F1C1 F1C1 C1
250mm

RB250m x 250m

RB250m x 250m

RB250m x 250m
3.50 250mm

3.50
3.50

3.50

wf wf
NOTE: PLEASE REFER TO FOOTING
SIZE 250mm x 250mm
AND COLUMN SCHEDULE FOR THE VERT. BARS 4 - 16mm Ø
DIMENSIONS AND SIZING OF BARS 10mm Ø: 1 SET 4-50mm, 3-75mm,
F1C1 wf F1C1 wf F1C1 TIES
2-100mm, REST @ 150mm O.C.
RB250m x 250m RB250m x 250m
MATERIAL SPECIFICATIONS:
fc' = 20.7 MPa (3,000 psi)
"N2" MATTING BARS fvy = 230 MPa (33,000 psi) FOR 10MMØ STIRRUPS
2.00

2.00
2.00

2.00

PLAN SEE FOOTING SCHEDULE fy = 414 MPa (60,000 psi) FOR 16MMØ BARS AND ABOVE

STIRRUPS
F1C1 F1C1 F1C1 F1C1 F1C1 F1C1 SEE BEAM SCHEDULE
3.50 3.50 3.50 3.50

7.00 7.00

FOUNDATION PLAN ROOF BEAM PLAN BOTTOM BARS


SEE BEAM SCHEDULE
TOP BARS
SEE BEAM SCHEDULE
NOTE: PLEASE REFER TO RC BEAMS
SCHEDULE FOR DIMENSIONS AND
SCALE: 1:110M. SCALE: 1:110M. SIZING OF BARS

TYPICAL BEAM DETAIL


SCHEDULE OF RC BEAMS SCHEDULE OF FOOTINGS
BEAM SIZE MAIN BARS STIRRUPS
FOOTING DIMENSIONS REINFORCEMENTS
MARK WIDTH DEPTH LEFT RIGHT 10mmØ EXCAVATION
MIDSPAN MARK
(mm) (mm) SUPPORT SUPPORT SPACED AT: WIDTH, B LENGTH, L THICKNESS DEPTH ( m )
(mm) (mm) t (mm) N1 (PCS) N2 (PCS)
TOP 3 - 16mm Ø 2 - 16mm Ø 3 - 16mm Ø
RB 250 250 6@50, 6@100, F1 1200 1200 250 1.20 6 - 16MM Ø 6 - 16MM Ø
BOTTOM 2 - 16mm Ø 3 - 16mm Ø 2 - 16mm Ø
REST @150mm O.C. TO C.L.
SIDE NONE NONE NONE MATERIAL SPECIFICATIONS:
MATERIAL SPECIFICATIONS: fc' = 20.7 MPa (3,000 psi)
fc' = 20.7 MPa (3,000 psi) fy = 414 MPa (60,000 psi) FOR 16MMØ BARS AND ABOVE
fvy = 230 MPa (33,000 psi) FOR 10MMØ STIRRUPS ASSUMED ALLOWABLE SOIL PRESSURE = 168 MPa (3500 psf)
fy = 414 MPa (60,000 psi) FOR 16MMØ BARS AND ABOVE

FROM THE OFFICE OF: APPROVED BY: SEAL: PROJECT TITLE: APPROVED AS TO PLANS & LOCATION: SHEET CONTENTS: SHEET NO.
REG. NO.: FOUNDATION PLAN

CONSTRUCTION OF ONE STOREY ROOF BEAM PLAN

S
7
DATE: MR. & MRS. JANICE R. MONTE DE RAMOS TYPICAL BEAM DETAIL
TYPICAL WALL FOOTING
PTR. NO.: BUILDING OWNER SHED. OF REINFORCED

DATE: LOCATION: BARANGAY BAGTICAN, MAASIN CITY, LOCATION: BARANGAY BAGTICAN, MAASIN CITY,
CONCRETE
SCHED. OF FOOTINGS 1
TIN: SOUTHERN LEYTE SOUTHERN LEYTE
SCHED. OF RC BEAMS
1
LAV WC SH
THIS SITE

SEPTIC TANK
HB

VICINITY MAP
DRAWN NOT TO SCALE

CHECK VALVE
GATE VALVE
m WATER METER

SANITARY & WASTE WATER LAYOUT


SCALE: 1:110M. A. THE MAIN WATER SOURCE
B. ANY ADDITIONAL SOURCE PROVIDED BY THE OWNER
INSTRUCTION TO PARTICULAR SPECIFICATIONS:

WATER SUPPLY & DISTRIBUTION PLAN PLUMBING NOTES:


A. WHERE MANUFACTURER OR SUPPLIER ARE NOMINATED IN THIS SPECIFICATION, SELECTION SHALL BE MADE AMONG
THOSE
B. WHERE THERE IS NO RECOMMENDED FOR MANUFACTURER OR SUPPLIER, SAMPLE OF THE MATERIALS WITH NECESSARY
SCALE: 1:110M. 1. ALL PLUMBING SHALL BE IN ACCORDANCE WITH THE GOVERNING CODES AND REGULATIONS OF
THE PHILIPPINE PLUMBING CODES, APPLICABLE RULES AND REGULATIONS OF THE MUNICIPALITY
INFORMATION SHALL BE SUBMITTED TO THE SUPERVISOR FOR APPROVAL.

WHICH ARE HEREBY MADE PART OF THESE PLANS.


SPECIFICATION:

LEGEND :
2. THE SPECIFICATIONS & DRAWINGS ARE MUTUALLY COMPLIMENTARY, IN ALL CASE OF CONFLICT,
THE SPECIFICATION SHALL PREVAIL OVER THE DRAWINGS.
1. ALL HORIZONTAL PIPING SHALL BE RUN IN PRACTICAL ALIGNMENT AND UNIFORM GRADE NOT LESS THAN 2% AND SHALL
3. THE DRAWING SHOW THE GENERAL ARRANGEMENT OF ALL THE PIPING HOWEVER,
BE SUPPORTED OR ANCHORED AT INTERNAL NOT TO EXCEED 10 FEET.
WHERE LOCAL OR ACTUAL CONDITIONS AT THE JOB SITE NECESSITATE A RE STATION OR REARRANGEMENT,
THE CONTRACTOR SHALL PREPARE & SUBMIT THE NEW ARRANGEMENT FOR THE ENGINEER/ARCHITECH APPROVAL.
FD FLOOR DRAIN FC FAUCET 4. THE PLUMBING SYSTEM SHALL BE LAID OUT & INSTALLED CONSISTENCY THROUGHOUT WITH THE GIVEN SLOPES
2. ALL PIPES PASSING THRU OR UNDER WALLS AND DRIVEWAYS SHALL BE PROPERLY PROTECTED AGAINST BREAKAGE.

IN THE PLANS & SHALL CONFORM TO THE ACTUAL LOCATION DEPTH & INVERT ELEVATION OF EXISTING PIPES WHERE
3. ALL CAULKED JOINTS SHALL BE FIRMLY PACKED WITH OAKUM OR OIL TREATED HEMP AND BE PROPERLY SECURED ONLY
THE TAPPING POINT OF EACH SYSTEM.
WITH THE PURE LEAD NOT LESS THAN 1" DEEP WELL CAULKED.
WC WATER CLOSET CHECK VALVE 5. ALL ABOVE GROUND STORM DRAIN & UNDER PASSING UNDER SLAB SHALL BE POLYVINYL CHLORIDE (PVC)
6 THE SANITARY SEWER LINES SHALL BE PVC PIPES & FITTING SCH. 40. THE SLOPE FOR HORIZONTAL SEWER LINES
4. WORKMANSHIP SHALL BE OF SUCH CHARACTER AS TO FULLY SECURE THE RESULTS SOUGHT IN ALL PROVISION OF THE
SHALL BE IN 1% FOR 100MM DIA, & ABOVE 4.2% FOR 75MM DIA. BELOW.
NATIONAL PLUMBING CODE INCLUDING THE FURNISHING OF ALL FITTINGS, TRAPS,VALVES, AND ACCESSORIES REQUIRED

LAV LAVATORY GATE VALVE 7. ALL VENT PIPING SHALL BE PVC SCH. 40 AS APPROVED BY THE ARCHITECT, ALL PLUMBING FIXTURES SHALL BE
INDIVIDUALLY VENTED UNLESS OTHERWISE INDICATED THE VENT BRANCH OF THE SEWER LINE SHALL BE TAKEN AT
FOR PROPER PLUMBING SYSTEM.

A VERTICAL ANGLE OR FORM THE TOP OR HORIZONTAL.

CLEAN OUT m WATER METER 8. ALL PLUMBING WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF SANITARY ENGINEER OR A MASTER
CERTIFICATION:
CO PLUMBER.
9. VERIFY AND DETERMINE, SUBJECT TO THE ARCHITECTS APPROVAL. THE BEST LOCATION T WHICH TO CONNECT THE
DRAINAGE SYSTEM TO EXISTING STREET DRAIN OR TO OTHER CONVENIENT ACCEPTABLE APPROVED WATER DISCHARGE THIS IS TO CERTIFY THAT THERE SHOULD BE NO ARTESIAN WELL BE CONSTRUCTED WITHIN 25.00MTS. RADIUS
RECEIVER IN ALL CASES, PROVIDE STORM DRAINAGE LINES WITH 2% MINIMUM SLOPE TOWARDS DIRECTION OF DRAIN.
KS KITCHEN SINK 10. VERIFY AND DETERMINE SUBJECT TO THE ARCHITECTS APPROVAL, THE BEST SOURCE OF WATER, THE CONNECTOR FROM THE PROPOSED SEPTIC VAULT.
SHALL BE RESPONSIBLE FOR TAPPING THE WATER SYSTEM TO THE SOURCE, EITHER FROM:

FROM THE OFFICE OF: APPROVED BY: SEAL: PROJECT TITLE: APPROVED AS TO PLANS & LOCATION: SHEET CONTENTS: SHEET NO.
REG. NO.:
P
WATER SUPPLY &
CONSTRUCTION OF ONE STOREY

8
DATE: MR. & MRS. JANICE R. MONTE DE RAMOS DISTRIBUTION PLAN
SANITARY & WATER LAYOUT
PTR. NO.: BUILDING OWNER PLUMBING NOTES
DATE: LOCATION: BARANGAY BAGTICAN, MAASIN CITY, LOCATION: BARANGAY BAGTICAN, MAASIN CITY, VICINITY MAP 1
TIN: SOUTHERN LEYTE SOUTHERN LEYTE LEGEND 2
HB
LAV
WC
SH

K
TAN C
PTI
SE

ISOMETRIC VIEW
WATER SUPPLY & DISTRIBUTION PLAN ISOMETRIC VIEW

SCALE: 1:80 M. SANITARY & WASTE WATER LAYOUT


C
G HECK
SCALE: 1:80 M.
m
WATATE VAL VALVE
ER M VE
ETE
R

0.15 1.35 0.15 2.35 0.15


O.C. BOTH WAYS 0.60
10mmØ @ 0.20m 0.60
0.60 X 0.60m 0.60 X 0.60m
4.00 MANHOLE MANHOLE

1.50 2.50
NGL 0.15 0.60 CONCRETE COVER W/
0.20mm AIR SPACE HANDLE 10mm Ø BAR
SPCD. @ 0.2M
0.15
4" PVC INLET PIPE
CO FOR WASTE
1.60

0.60

0.60
0.60 X 0.60m 0.60 X 0.60m LEACHING DIGESTIVE CHAMBER
MANHOLE MANHOLE CHAMBER 10mmØ @ 0.20m

1.35 6" CHB WITH 10mmØ


REBARS SPACED
SLOPE
CO CO @ 0.60m O.C.BOTH WAYS

CO 0.10
0.60
0.15
0.15 PLAN SECTION
10mmØ SPACED Ø 0.40 O.C. BOTH
0.15 1.35 2.50 3-10mmØ WITH 10mmØ WAYS
4" PVC OUTLET
4" PVC INLET PIPE FOR
DRAIN / SEWER
4" PVC INLET PIPE FOR
DRAIN / SEWER
TEMPERATURE BARS
SPACED Ø 0.40 O.C. MANHOLE DETAIL
SCALE: NTS
SYPTIC TANK DETAIL
SCALE: 1:60M.
FROM THE OFFICE OF: APPROVED BY: SEAL: PROJECT TITLE: APPROVED AS TO PLANS & LOCATION: SHEET CONTENTS: SHEET NO.
REG. NO.:
P
WATER SUPPLY &
CONSTRUCTION OF ONE STOREY

9
DATE: MR. & MRS. JANICE R. MONTE DE RAMOS DISTRIBUTION PLAN
SANITARY & WATER LAYOUT
PTR. NO.: BUILDING OWNER SYPTIC TANK DETAIL
DATE: LOCATION: BARANGAY BAGTICAN, MAASIN CITY, LOCATION: BARANGAY BAGTICAN, MAASIN CITY, MANHOLE DETAIL 2
TIN: SOUTHERN LEYTE SOUTHERN LEYTE 2
7.00
7.00
3.50 3.50
3.50 3.50

j j

o o
LEGEND
SYMBOL LIGHTING FIXTURE 1.50 1.50
1.50 p m
1.50
o (o,p) o

(m,n) h
h

CKT 2

j j CKT 5

n
(g,h) 3.00 3.00
3.00 3.00
g

S1 CKT 7

h h

f f S2

e S3 3.50 3.50
3.50 j i (i,j) j 3.50
(e,f)
13.50 13.50
13.50 13.50 CKT 6

PB
f f

b b d d
LEGEND
SYMBOL OUTLET FIXTURE
(c,d)
3.50 3.50
3.50 j j 3.50
c
a
CO PB
PB
CKT 1

b b d d
(a,b) GFCI
(k,L)
CKT 3

2.00 k L L
CKT 4
k
2.00 REF 2.00 2.00

PB

3.50 3.50
3.50 3.50
7.00
7.00

POWER LAYOUT ELECTRICAL LAYOUT


SCALE: 1:100M.
SCALE: 1:100M.

CIVIL ENGINEER SEAL: PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO.
REG. NO.: POWER LAYOUT
DATE: CONSTRUCTION OF ONE STOREY MR. & MRS. JANICE R. MONTE DE RAMOS ELECTRICAL LAYOUT
E
PTR. NO.:
DATE:
TIN:
BUILDING
LOCATION: BARANGAY BAGTICAN, MAASIN CITY,
SOUTHERN LEYTE
LOCATION:
OWNER
BARANGAY BAGTICAN, MAASIN CITY,
SOUTHERN LEYTE
LEGENDS

1
2
10
ELECTRICAL GENERAL NOTES AND SPECIFICATIONS : THIS SITE
SERVICE ENTRANCE
M
2 -8.00 mm2 THW dia. PVC Pipe

60 A

15AT2P 15AT2P

2 1
LIGHTING LIGHTING

15AT2P 15AT2P

4 3
LIGHTING LIGHTING

15AT2P 15AT2P

CONVENIENCE
OUTLET
6 5 CONVENIENCE
OUTLET
VICINITY MAP
20AT2P 20AT2P DRAWN NOT TO SCALE
8 7
AIRCON spare REF

SCHEDULE OF LOADS:
LOADS SWITCHES VOLT. AMP. VOLT. AMP. CURRENT FUSE ACB SIZE OF WIRE CONDUIT
CKT. NO
CO LO S1 S2 S3
C1 10 2 1000 10 x 100W / 220V 4.45 A 15 AT 2P 2-2.0mm² THW
C2 10 2 1000 10 x 100W / 220V 4.45 A 15 AT 2P 2-2.0mm² THW 1
2" Ø PVC
C3 10 2 2 1000 10 x 100W / 220V 4.45 A 15 AT 2P 2-2.0mm² THW
C4 10 1 1000 10 x 100W / 220V 4.45 A 15 AT 2P 2-2.0mm² THW
C5 8 350 8 x 200W / 220V 7.27 A 15 AT 2P 2-2.0mm² THW
C6 5 350 5 x 200W / 220V 4.54 A 15 AT 2P 2-2.0mm² THW
3
1(REF) 1 4" Ø PVC
C7 350 x 350W / 220V 1.60 A 20 AT 2P 2-2.0mm² THW
TOTAL SPARE 31.21 A
MAIN FEEDER CONDUCTION SIZE CALCULATION: 31.21 A x 1.25 = 39.0125

MAIN FEEDER PROTECTION CALCULATION: 31.21 A x 0.85 x 250% = 66.32 A - USE 70 AMPS FUSE FOR MAIN CIRCUIT BREAKER

CIVIL ENGINEER SEAL: PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO.
REG. NO.: ELECTRICAL GENERAL NOTES
DATE: CONSTRUCTION OF ONE STOREY MR. & MRS. JANICE R. MONTE DE RAMOS & SPECIFICATION
E
PTR. NO.:
DATE:
BUILDING
LOCATION: BARANGAY BAGTICAN, MAASIN CITY, LOCATION:
OWNER
BARANGAY BAGTICAN, MAASIN CITY,
SCHED. OF LOADS
VICINITY MAP
2
2
11
TIN: SOUTHERN LEYTE SOUTHERN LEYTE

You might also like