Eekels Technology B.V.

A. Plesmanlaan 2
9615 TH Kolham
The Netherlands
Telephone +31 88 799 17 99
www.marpower.com

MAS VDR Interface Description


Vertom (Customer) - Thecla Bodewes Shipyards Kampen (Yard) Date of creation
Marpower Automation System November 24, 2021
Date of update
November 24, 2021
Project
52112003
Version
Author(s) R0.1
P. Verburg Status
For approval
Page
1 of 8

Approval projectmanager

Approval principal
8

Date of creation Version


November 24, 2021 R0.1
Date of update Status
November 24, 2021 For approval
Page
2 of 8

Contents

1 References 3
1.1 Change log 3
1.2 Abbreviations and definitions 4
1.3 Key words 4

2 Introduction 5
2.1 Purpose of document 5
2.2 Relationship to other documents 5

3 Operation 6
3.1 Connect/Disconnect 6
3.2 Create/Update/Delete 6
3.3 Cyclic transmission 6

4 Alarming 7

5 Technical details; Interfacing VDR 8


5.1 Communication 8
5.2 NMEA-0183 ALR sentence 8
8

Date of creation Version


November 24, 2021 R0.1
Date of update Status
November 24, 2021 For approval
Page
3 of 8

1 References

1.1 Change log

Version Description Author Date Approved


R0.1 - Initial document P. Verburg 2021-11-24
8

Date of creation Version


November 24, 2021 R0.1
Date of update Status
November 24, 2021 For approval
Page
4 of 8

1.2 Abbreviations and definitions

Abbreviation Description

BV Bureau Veritas
FDS Functional Design Specification
FTS Functional Test Specification
IP Internet Protocol
MAS Marpower Automation System
NMEA National Marine Electronics Association
PLC Programmable Logic Controller
TCP Transmission Control Protocol
VDR Voyage Data Recorder

Definition Description
Mimic A graphical, simplified presentation of a (sub) system
emphasizing the functionality of that system.

1.3 Key words

The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in RFC 2119.
(https://www.ietf.org/rfc/rfc2119)
8

Date of creation Version


November 24, 2021 R0.1
Date of update Status
November 24, 2021 For approval
Page
5 of 8

2 Introduction

2.1 Purpose of document

The purpose of this document is to describe the interfacing of the MAS Alarming
service to the ships VDR.

The VDR system provides a NMEA/RS422 interface to the MAS system to make a
connection for reporting alarms.

2.2 Relationship to other documents

Base documents:

Document ID Title Version / Date


2110 Platform Operation Manual R3
2210 Project Operation Manual R1.0
2220 Project Functional Description R1.0
52112003- System Overview MAS R2.1
424-01

Related documents:

Document ID Title Version / Date


4210 Project Functional Tests R0.0

Appendix:

Document ID Title Version / Date


8

Date of creation Version


November 24, 2021 R0.1
Date of update Status
November 24, 2021 For approval
Page
6 of 8

3 Operation

The VDR Interface uses events and information from the MAS Alarming service to
send NMEA-0183 ALR sentences to the VDR. Description of the ALR sentence can
be found in §5.2 NMEA-0183 ALR sentence

3.1 Connect/Disconnect

The connection between the Alarming and VDR Interface services can be
interrupted. Use cases include for example network/hardware failures or uploading
new I/O lists to the system.

Connect events are notified to the VDR with the following alert description:
‘Alarming/VDR Interface connected’.

After a connection is established, all alerts that are marked in the VDR column are
sent to the VDR including their current state.

Disconnect events are notified to the VDR with the following alert description:
‘Alarming/VDR Interface disconnected’. However, in case of failures, this sentence
might, or might not be sent.

3.2 Create/Update/Delete

Every change to alerts marked in the VDR column is notified to the VDR. Create
and Delete events are normally only sent if a new I/O list is uploaded to the system.

Updates include changes to:


Active or Idle
New or Acknowledged
Inhibited

3.3 Cyclic transmission

For later interpretation and/or visualization purposes every five minutes the current
list of active and/or unacknowledged alerts are retransmitted to the VDR.
8

Date of creation Version


November 24, 2021 R0.1
Date of update Status
November 24, 2021 For approval
Page
7 of 8

4 Alarming

The IO-list contains the definitions of the related alarm items for the MAS system.
The alarms to be reported to the VDR are selected in the I/O list by using the VDR
column.

See below screenshot of the alarm list column detail :


8

Date of creation Version


November 24, 2021 R0.1
Date of update Status
November 24, 2021 For approval
Page
8 of 8

5 Technical details; Interfacing VDR

5.1 Communication

The MAS communicates to the VDR by using a TCP/IP to serial gateway.

TCP/IP gateway
Gateway IP address : 192.168.100.127
Port : 4003

RS422 Serial settings;


Protocol : NMEA/RS422
Baudrate : 4800
Parity : None
Databits :8
Stop bits :1

5.2 NMEA-0183 ALR sentence

The VDR Interface uses ‘II’ as Talker ID.

Note to field b: This field can only be used up to 999. Since the alarming service
normally has more alerts, this field is not used.

Note to field e: This field is formatted to contain both the alert ID, inhibit state and
tag separated with a space.
“<id> I:<inhibited yes/no> <tag>”

For example: the first alert ME PS lub. oil pressure low low 2.1 bar – SHUTDOWN
would then become:
“0 I:no MEPS_LO_PLL_SHD.LL”

This way, description will not exceed 79 characters while still being quite readable.
Alarm Commissioning Report 2024/10/01 07:06:35

Acknowledge Location

Sounding Locations
Normal Condition

Disallow Inhibit
Output Contact

Range Upper
Range Lower

Group Alarm
Scale Factor
Class. Appr.
Description

MB Address
Cust. Appr.

MB Server
Data Type

MB Func.
On Delay
Set Point
Checked

Terminal
Revision

Module
Priority

Source
Device

VDR ID

Cat. A
Code

Lock
Type

Unit
GEA
0004 F SWBR AMCS 1 Power Supply Failure R0.0 Alarm TBD KEB1 DI00 1 Wago Bool TBD TBD = False 0s ER
0005 F SWBR AMCS 1 Power Distribution Insulation Failure R0.0 Alarm TBD KEB1 DI00 2 Wago Bool TBD TBD = False 0s ER
0026 F Main Power Supply Valves Failure R0.0 Alarm TBD KEB1 DI02 7 Wago Bool TBD TBD = False 0s ER
0027 F Backup Power Supply Valves Failure R0.0 Alarm TBD KEB1 DI02 8 Wago Bool TBD TBD = False 0s ER
0052 F AMCS PLC KEB1 Power Module 1 Internal Fuse Blown R0.0 Alarm TBD KEB1 F1 1 Wago Bool TBD TBD = False 0s ER
0053 F AMCS PLC KEB1 Power Module 1 Power Failure R0.0 Alarm TBD KEB1 F1 2 Wago Bool TBD TBD = True 0s ER
0054 F Temp Alarm Switch board R0.0 Alarm TBD KEB1 DI20 1 Wago Bool TBD TBD = False 0s ER
0058 F EHDG CB tripped R0.0 Alarm TBD KEB1 DI20 5 Wago Bool TBD TBD = False 0s ER
0062 F EHDE Common alarm R0.0 Alarm TBD KEB1 DI21 1 Wago Bool TBD TBD = False 0s v ER
0067 F Watermaker Failure R0.7 Alarm TBD KEB1 DI21 6 Wago Bool TBD TBD = False 0s ER
0068 F Standby Cooling Water circulation pump started R0.0 Warning TBD KEB1 DI21 7 Wago Bool TBD TBD = False 0s ER
0069 F Fresh CW Expansion Tank - Low Level Alarm R0.0 Alarm TBD KEB1 DI21 8 Wago Bool TBD TBD = False 0s ER
0072 F Gas Oil Separator Alarm R0.0 Alarm TBD KEB1 DI22 3 Wago Bool TBD TBD = False 5s 5s ER
0076 F Anti-fouling System Common Alarm R0.0 Alarm TBD KEB1 DI22 7 Wago Bool TBD TBD = False 0s v ER
0077 F Non-preferent - Activated R0.0 Alarm TBD KEB1 DI22 8 Wago Bool TBD TBD = False 0s ER
0078 F EmStop Alarm Main Supply Failure R0.0 Alarm TBD KEB1 DI23 1 Wago Bool TBD TBD = False 0s ER
0079 F EmStop Alarm Aux Supply Failure R0.0 Alarm TBD KEB1 DI23 2 Wago Bool TBD TBD = False 0s ER
0080 F 24VDC distr system 02 charger failure R0.0 Alarm TBD KEB1 DI23 3 Wago Bool TBD TBD = False 0s ER
0081 F 24VDC distr system 02 power failure R0.0 Alarm TBD KEB1 DI23 4 Wago Bool TBD TBD = False 0s ER
0082 F 24VDC distr system 02 common failure R0.0 Alarm TBD KEB1 DI23 5 Wago Bool TBD TBD = False 0s ER
0085 F LO Store Tank (50) - High Level Alarm R0.2 Alarm TBD KEB1 DI23 8 Wago Bool TBD TBD = False 5s 5s ER
0086 F Dirty Oil Tank (61) - High Level Alarm R0.2 Alarm TBD KEB1 DI24 1 Wago Bool TBD TBD = False 5s 5s ER
0087 F MDO Day Tank 1 (44) - Low Level Alarm R0.2 Alarm TBD KEB1 DI24 2 Wago Bool TBD TBD = False 5s 5s ER
0088 F MDO Day Tank 2 (45) - High High Level Alarm R0.0 Alarm TBD KEB1 DI24 3 Wago Bool TBD TBD = False 5s 5s ER
0089 F MDO Em'cy Tank (46) - Low Level Alarm R0.2 Alarm TBD KEB1 DI24 4 Wago Bool TBD TBD = False 5s 5s ER
0090 F MDO Em'cy Tank (46) - High Level Alarm R0.2 Alarm TBD KEB1 DI24 5 Wago Bool TBD TBD = False 5s 5s ER
0091 F Bilge Water Tank (60) - High Level Alarm R0.2 Alarm TBD KEB1 DI24 6 Wago Bool TBD TBD = False 5s 5s ER
0092 F Sewage Tank (62) - High Level Alarm R0.2 Alarm TBD KEB1 DI24 7 Wago Bool TBD TBD = False 5s 5s ER
0093 F CPU Status OK R0.0 Alarm TBD KEB1 DI24 8 Wago Bool TBD TBD = False 0s ER
0094 F Group Alarm System 1 R0.0 Alarm TBD KEB1 DI25 1 Wago Bool TBD TBD = False 0s v ER
0095 F Group Alarm System 2 R0.0 Alarm TBD KEB1 DI25 2 Wago Bool TBD TBD = False 0s v ER
0096 F FU CPU Status OK R0.0 Alarm TBD KEB1 DI25 3 Wago Bool TBD TBD = False 0s ER
0097 F OIL Level Low System 1 R0.0 Alarm TBD KEB1 DI25 4 Wago Bool TBD TBD = False 0s ER
0098 F OIL Level Low System 2 R0.0 Alarm TBD KEB1 DI25 5 Wago Bool TBD TBD = False 0s ER
0099 F System part disabled R0.0 Alarm TBD KEB1 DI25 6 Wago Bool TBD TBD = False 0s ER
0100 F Common fire (Pre Alarm) R0.0 Alarm TBD KEB1 DI25 7 Wago Bool TBD TBD = False 0s v ER
0101 F Discharge Alarm R0.0 Alarm TBD KEB1 DI25 8 Wago Bool TBD TBD = False 0s ER
0102 F Common fault R0.0 Alarm TBD KEB1 DI26 1 Wago Bool TBD TBD = False 0s v ER
0104 F 24VDC Distr system 02 Battery Fuse Failure R0.4 Alarm TBD KEB1 DI26 3 Wago Bool TBD TBD = False 0s ER
0105 F Bilge Alarm Engine Room - Fore PS Level High I009 R0.1 Alarm TBD KEB1 DI26 4 Wago Bool TBD TBD = False 5s 5s ER
0106 F Bilge Alarm Engine Room - Fore SB Level High I008 R0.1 Alarm TBD KEB1 DI26 5 Wago Bool TBD TBD = False 5s 5s ER
0107 F Bilge Alarm Engine Room - Aft Level High I007 R0.1 Alarm TBD KEB1 DI26 6 Wago Bool TBD TBD = False 5s 5s ER
0108 F Bilge Alarm Steering Gear Room - Level High I010 R0.1 Alarm TBD KEB1 DI26 7 Wago Bool TBD TBD = False 5s 5s ER
0109 F Bilge Alarm Hold BW DB PS 20 - Level High I005 R0.7 Alarm TBD KEB1 DI26 8 Wago Bool TBD TBD = False 5s 5s ER
0112 F Bilgewater Separator Common Alarm R0.0 Alarm TBD KEB1 DI27 3 Wago Bool TBD TBD = False 0s v ER
0113 F Bilgewater Separator Long Time Running Alarm R0.0 Alarm TBD KEB1 DI27 4 Wago Bool TBD TBD = False 0s ER
0114 F CO2 Control Panel Fault R0.0 Alarm TBD KEB1 DI27 5 Wago Bool TBD TBD = False 0s ER
0115 F CO2 Control Panel Pre-Alarm R0.0 Alarm TBD KEB1 DI27 6 Wago Bool TBD TBD = False 0s ER
0116 F Lubrication Pressure Low Low - Shutdown R0.0 Emergency TBD KEB1 DI27 7 Wago Bool TBD SoftPlc.AT_LEAST_ONE_MOTOR_RUNNING = False TBD = False 0s ER Bridge
0118 F Lubrication Oil Filter Diff. Pressure High R0.0 Alarm TBD KEB1 DI28 1 Wago Bool TBD TBD = False 0s ER
0119 F Lubrication Oil Level Low (LSL300) R0.0 Alarm TBD KEB1 DI28 2 Wago Bool TBD SoftPlc.AT_LEAST_ONE_MOTOR_RUNNING = False TBD = False 0s ER
0120 F Thrust Bearing Temperature High High - Load reduction R0.0 Alarm TBD KEB1 DI28 3 Wago Bool TBD TBD = False 0s ER Bridge
0123 F Ballast Water Treatment Unit Common Alarm R0.0 Alarm TBD KEB1 DI28 6 Wago Bool TBD TBD = False 0s v ER
0124 F Ballast Water Treatment Unit Common Warning R0.0 Warning TBD KEB1 DI28 7 Wago Bool TBD TBD = False 0s v ER
0126 F Bilge Pipeduct Level High R0.0 Alarm TBD KEB1 DI29 1 Wago Bool TBD TBD = False 0s ER
0127 F Sterntube Oiltank Level Low R0.0 Alarm TBD KEB1 DI29 2 Wago Bool TBD TBD = False 5s 5s ER
0131 F Water Ingress Hold Water Level High R0.6 Alarm TBD KEB1 DI29 6 Wago Bool TBD TBD = False 0s ER
0132 F Water Ingress Hold Water Level High High R0.0 Alarm TBD KEB1 DI29 7 Wago Bool TBD TBD = False 0s ER
0135 F MDO Day Tank 1 (44) – High Level Alarm R0.2 Alarm TBD KEB1 DI30 2 Wago Bool TBD TBD = False 0s ER
0150 HH Sewage Tank 62 - LEVEL R0.2 Alarm TBD KEB1 AI20 1 Wago Float 0 800 TBD mbar TBD > 1300 0s ER
0151 HH MDO Day Tank 1 44 - LEVEL R0.2 Alarm TBD KEB1 AI20 2 Wago Float 0 1000 TBD mbar TBD > 1300 0s ER
0152 HH MDO Day Tank 2 45 - LEVEL R0.2 Alarm TBD KEB1 AI20 3 Wago Float 0 1000 TBD mbar TBD > 1300 0s ER
0153 HH MDO Emergency Tank 46 - LEVEL R0.2 Alarm TBD KEB1 AI20 4 Wago Float 0 400 TBD mbar TBD > 1300 0s ER
0154 L Lubrication Oil Pressure Low (PT200) R0.0 Alarm TBD KEB1 AI21 1 Wago Float 0 10 TBD Bar SoftPlc.AT_LEAST_ONE_MOTOR_RUNNING = False TBD < 0.6 0s ER
0170 H Lubrication Oil Inlet Temperature High (TE100) R0.0 Alarm TBD KEB1 AI25 1 Wago Float -200 850 TBD °C TBD > 55 0s ER
0171 H Thrust Bearing Temperature High (TE400) R0.0 Alarm TBD KEB1 AI25 2 Wago Float -200 850 TBD °C TBD > 70 0s ER

52212021 - Vertom C293 Page 1 / 7


Alarm Commissioning Report 2024/10/01 07:06:35

Acknowledge Location

Sounding Locations
Normal Condition

Disallow Inhibit
Output Contact

Range Upper
Range Lower

Group Alarm
Scale Factor
Class. Appr.
Description

MB Address
Cust. Appr.

MB Server
Data Type

MB Func.
On Delay
Set Point
Checked

Terminal
Revision

Module
Priority

Source
Device

VDR ID

Cat. A
Code

Lock
Type

Unit
GEA
AMCS System
180 F AMCS PLC KEB1 Power Module 2 Fuse Blown R0.0 Alarm TBD KEB1 F2 1 Wago Bool TBD TBD = False 0s ER
181 F AMCS PLC KEB1 Power Module 2 Power Failure R0.0 Alarm TBD KEB1 F2 2 Wago Bool TBD TBD = True 0s ER
0311 F AMCS PLC KEB3 Power Module 1 Fuse Blown R0.0 Alarm TBD KEB3 F1 1 Wago Bool TBD TBD = False 0s ER
0312 F AMCS PLC KEB3 Power Module 1 Power Failure R0.0 Alarm TBD KEB3 F1 2 Wago Bool TBD TBD = True 0s ER
0366 F BOSUN AMCS Power Supply Failure R0.0 Alarm TBD KEB2 DI00 1 Wago Bool TBD TBD = False 0s ER
0367 F BOSUN AMCS Power Distribution Insulation Failure R0.0 Alarm TBD KEB2 DI00 2 Wago Bool TBD TBD = False 0s ER
0370 F BOSUN AMCS Power UPS Battery Mode R0.0 Warning TBD KEB2 DI00 5 Wago Bool TBD TBD = True 0s v ER
0371 F BOSUN VALVES Main Power Supply Failure R0.0 Alarm TBD KEB2 DI00 6 Wago Bool TBD TBD = False 0s ER
0372 F BOSUN VALVES Power Supply Failure R0.0 Alarm TBD KEB2 DI00 7 Wago Bool TBD TBD = False 0s ER
0373 F BOSUN AMCS Power UPS Alarm R0.0 Alarm TBD KEB2 DI00 8 Wago Bool TBD TBD = False 0s ER
0382 F BOSUN AMCS PLC KEB2 Power Module 1 Internal Fuse Blown R0.0 Alarm TBD KEB2 F1 1 Wago Bool TBD TBD = False 0s ER
0383 F AMCS PLC KEB2 Power Module 1 Power Failure R0.0 Alarm TBD KEB2 F1 2 Wago Bool TBD TBD = True 0s ER
0388 F AMCS PLC KEB2 Power Module 2 Fuse Blown R0.0 Alarm TBD KEB2 F2 1 Wago Bool TBD TBD = False 0s ER
0389 F AMCS PLC KEB2 Power Module 2 Power Failure R0.0 Alarm TBD KEB2 F2 2 Wago Bool TBD TBD = True 0s ER

0420 F MDO Tank 1 SB (41) - High Level Alarm R0.2 Alarm TBD KEB2 DI63 7 Wago Bool TBD TBD = False 5s 5s ER
0421 F MDO Tank 2 PS (40) - High Level Alarm R0.2 Alarm TBD KEB2 DI63 8 Wago Bool TBD TBD = False 5s 5s ER
0422 F Door To Paint Store open R0.0 Warning TBD KEB2 DI64 1 Wago Bool TBD TBD = False 0s BRG
0423 F MDO Overflow Tank (43) - High High Level Alarm R0.2 Alarm TBD KEB2 DI64 2 Wago Bool TBD TBD = False 5s 5s ER
0425 F Bilge Alarm Bowthruster Room - Level High I001 R0.1 Alarm TBD KEB2 DI64 4 Wago Bool TBD TBD = False 5s 5s ER
0426 F Bilge Alarm Bosun Store PS - Level High I003 R0.1 Alarm TBD KEB2 DI64 5 Wago Bool TBD TBD = False 5s 5s ER
0427 F MDO Overflow Tank (43) - Alarm R0.2 Alarm TBD KEB2 DI64 6 Wago Bool TBD TBD = False 5s 5s ER
0428 F Dirty Oil Tank (61) - High Level Alarm R0.2 Alarm TBD KEB2 DI64 7 Wago Bool TBD TBD = False 5s 5s ER
0429 F Door to Forecastle space Open R0.0 Warning TBD KEB2 DI64 8 Wago Bool TBD TBD = False 0s BRG
0430 F Door to CO2 room Open R0.0 Warning TBD KEB2 DI65 1 Wago Bool TBD TBD = False 0s BRG
0431 F Door to Hold vent / Entrace Open R0.0 Warning TBD KEB2 DI65 2 Wago Bool TBD TBD = False 0s BRG
0432 F WB FP Tank 601 - 10% Tank vol. R0.0 Alarm TBD KEB2 DI65 3 Wago Bool TBD TBD = False 5s 5s ER
0433 F BTR Rm - 0.1m Above Deck Water LVL H R0.0 Alarm TBD KEB2 DI65 4 Wago Bool TBD TBD = False 5s 5s ER
0434 F Bosun STR - 0.1m Above Deck Water LVL H R0.0 Alarm TBD KEB2 DI65 5 Wago Bool TBD TBD = False 5s 5s ER
0435 F Bowthruster Lube Oil Tank Level Low R0.7 Alarm TBD KEB2 DI65 6 Wago Bool TBD TBD = False 5s 5s ER

0438 F AMCS PLC KEB2 Power Module 3 Fuse Blown R0.0 Alarm TBD KEB2 F3 1 Wago Bool TBD TBD = False 0s ER
0439 F AMCS PLC KEB2 Power Module 3 Power Failure R0.0 Alarm TBD KEB2 F3 2 Wago Bool TBD TBD = True 0s ER
0473 F Bridge AMCS Power Supply Failure R0.0 Alarm TBD KEB6 DI00 1 Wago Bool TBD TBD = False 0s ER
0474 F Bridge AMCS Power Distribution Insulation Failure R0.0 Alarm TBD KEB6 DI00 2 Wago Bool TBD TBD = False 0s ER
0477 F Bridge Buzzers Power Supply Failure R0.0 Alarm TBD KEB6 DI00 5 Wago Bool TBD TBD = False 0s ER
0489 F AMCS PLC KEB6 Power Module 1 Internal Fuse Blown R0.0 Alarm TBD KEB6 F1 1 Wago Bool TBD TBD = False 0s ER
0490 F AMCS PLC KEB6 Power Module 1 Power Failure R0.0 Alarm TBD KEB6 F1 2 Wago Bool TBD TBD = True 0s ER

0491 F ECDIS-1 - UPS Failure R0.0 Alarm TBD KEB6 DI20 1 Wago Bool TBD TBD = False 0s BRG
0492 F ECDIS-2 - UPS Failure R0.0 Alarm TBD KEB6 DI20 2 Wago Bool TBD TBD = False 0s BRG
0493 F 24VDC Distr System 01 Charger Failure R0.0 Alarm TBD KEB6 DI20 3 Wago Bool TBD TBD = False 0s ER
0494 F 24VDC Distr System 01 Power Failure R0.0 Alarm TBD KEB6 DI20 4 Wago Bool TBD TBD = False 0s ER
0495 F 24VDC Distr System 01 Common Failure R0.0 Alarm TBD KEB6 DI20 5 Wago Bool TBD TBD = False 0s ER
0496 F Fire Alarm Panel Common Alarm R0.0 Alarm TBD KEB6 DI20 6 Wago Bool TBD TBD = False 0s v BRG
0497 F Bridge Watch Alarm Panel Power Failure R0.0 Alarm TBD KEB6 DI20 7 Wago Bool TBD TBD = False 0s BRG
0498 F 24VDC Distr System 01 Battery Fuse Failure R0.4 Alarm TBD KEB6 DI20 8 Wago Bool TBD TBD = False 0s ER
0499 F AMCS PLC KEB6 Power Module 2 Fuse Blown R0.0 Alarm TBD KEB6 F2 1 Wago Bool TBD TBD = False 0s BRG
0500 F AMCS PLC KEB6 Power Module 2 Power Failure R0.0 Alarm TBD KEB6 F2 2 Wago Bool TBD TBD = True 0s BRG
0503 F Smoke Detection Fire Alarm R0.3 Alarm TBD KEB6 DI60 3 Wago Bool TBD TBD = False 0s BRG
0504 F Smoke Detection Fault R0.3 Alarm TBD KEB6 DI60 4 Wago Bool TBD TBD = False 0s BRG
0509 F AMCS PLC KEB6 Power Module 3 Fuse Blown R0.0 Alarm TBD KEB6 F3 1 Wago Bool TBD TBD = False 0s BRG
0510 F AMCS PLC KEB6 Power Module 3 Power Failure R0.0 Alarm TBD KEB6 F3 2 Wago Bool TBD TBD = True 0s BRG
0540 F Communication Lost with BT Lever R0.3 Alarm TBD KEB7 0 Wago Bool TBD TBD = False 10 s BRG
0546 F Communication With PMS System Lost R0.3 Alarm TBD KEB7 0 Wago Bool TBD TBD = True BRG

52212021 - Vertom C293 Page 2 / 7


Alarm Commissioning Report 2024/10/01 07:06:35

Acknowledge Location

Sounding Locations
Normal Condition

Disallow Inhibit
Output Contact

Range Upper
Range Lower

Group Alarm
Scale Factor
Class. Appr.
Description

MB Address
Cust. Appr.

MB Server
Data Type

MB Func.
On Delay
Set Point
Checked

Terminal
Revision

Module
Priority

Source
Device

VDR ID

Cat. A
Code

Lock
Type

Unit
GEA
Aux Engine
0718 F GEN1 Low Water Level HT R0.8 Alarm TBD KEC2_ME_GEN_1 Modbus Bool TBD TBD = False 0s ER 1 HoldingRegister 0
0719 F GEN1 Low Water Level LT R0.8 Alarm TBD KEC2_ME_GEN_1 Modbus Bool TBD TBD = False 0s ER 1 HoldingRegister 0
0733 F GEN1 Common Alarm R0.0 Alarm TBD KEC2_ME_GEN_1 Modbus Bool TBD TBD = False 0s v ER 1 HoldingRegister 9
0718 F GEN2 Low Water Level HT R0.8 Alarm TBD KEC2_ME_GEN_2 Modbus Bool TBD TBD = False 0s ER 1 HoldingRegister 0
0719 F GEN2 Low Water Level LT R0.8 Alarm TBD KEC2_ME_GEN_2 Modbus Bool TBD TBD = False 0s ER 1 HoldingRegister 0
0733 F GEN2 Common Alarm R0.0 Alarm TBD KEC2_ME_GEN_2 Modbus Bool TBD TBD = False 0s v ER 1 HoldingRegister 9
0718 F GEN3 Low Water Level HT R0.8 Alarm TBD KEC3_ME_GEN_3 Modbus Bool TBD TBD = False 0s ER 1 HoldingRegister 0
0719 F GEN3 Low Water Level LT R0.8 Alarm TBD KEC3_ME_GEN_3 Modbus Bool TBD TBD = False 0s ER 1 HoldingRegister 0
0733 F GEN3 Common Alarm R0.0 Alarm TBD KEC3_ME_GEN_3 Modbus Bool TBD TBD = False 0s v ER 1 HoldingRegister 9
0718 F GEN4 Low Water Level HT R0.8 Alarm TBD KEC3_ME_GEN_4 Modbus Bool TBD TBD = False 0s ER 1 HoldingRegister 0
0719 F GEN4 Low Water Level LT R0.8 Alarm TBD KEC3_ME_GEN_4 Modbus Bool TBD TBD = False 0s ER 1 HoldingRegister 0
0733 F GEN4 Common Alarm R0.0 Alarm TBD KEC3_ME_GEN_4 Modbus Bool TBD TBD = False 0s v ER 1 HoldingRegister 9
1086 F Torque Meter Failure R1.10 Alarm TBD KEC5_TORQUE Generic Bool TBD TBD = True 5 s 5s ER
1094 F Connection Between NavCom GPS and AMCS Broken R0.4 Alarm TBD NAVCOM_GPS Generic Bool TBD TBD = True ER
1109 F Connection Between NavCom Speed and AMCS Broken R0.4 Alarm TBD NAVCOM_SPEED Generic Bool TBD TBD = True ER
1114 F Connection Between NavCom Wind and AMCS Broken R0.4 Alarm TBD NAVCOM_WIND Generic Bool TBD TBD = True ER
I33 F Main Network Ring AMCS Broken R0.0 Warning TBD SoftPlc Generic Bool TBD TBD = False v ER
I34 F Drive Network Ring AMCS Broken R0.0 Warning TBD SoftPlc Generic Bool TBD TBD = False v ER
I47 F PCS Common Alarm R0.0 Alarm TBD Redundant Generic Bool TBD TBD = False v ER
I48 F Redundant Connection to KEB2 Broken R0.0 Alarm TBD SoftPlc Generic Bool TBD TBD = False v ER
I49 F Bilge Ballast Pump 1 Feedback Failure R0.0 Warning TBD KEB1 0 Wago Bool TBD TBD = True ER
I60 F Bilge Ballast Pump 2 Feedback Failure R0.0 Warning TBD KEB1 0 Wago Bool TBD TBD = True ER
I81 F Situation 1 Gravity Ballasting R0.1 Alarm TBD KEB1 0 Wago Bool TBD TBD = True 0s ER
I82 F Situation 2 Gravity Ballasting R0.1 Alarm TBD KEB1 0 Wago Bool TBD TBD = True 0s ER
I83 F Situation 3 Gravity De-Ballasting R0.1 Alarm TBD KEB1 0 Wago Bool TBD TBD = True 0s ER
I84 F Situation 4 Gravity De-Ballasting R0.1 Alarm TBD KEB1 0 Wago Bool TBD TBD = True 0s ER
I85 F Situation 5 Ejector 23-1-B005 R0.1 Alarm TBD KEB1 0 Wago Bool TBD TBD = True 0s ER
I86 F Situation 6 Ejector 23-1-B005 R0.1 Alarm TBD KEB1 0 Wago Bool TBD TBD = True 0s ER
I87 F Situation 7 De-Ballasting by FiFi Line R0.1 Alarm TBD KEB1 0 Wago Bool TBD TBD = True 0s ER
I88 F Situation 8 De-Ballasting via FiFi Line R0.1 Alarm TBD KEB1 0 Wago Bool TBD TBD = True 0s ER
I89 F Situation 9 De-Ballasting via FiFi Line R0.1 Alarm TBD KEB1 0 Wago Bool TBD TBD = True 0s ER
I90 F Situation 10 De-Ballasting via FiFi Line R0.1 Alarm TBD KEB1 0 Wago Bool TBD TBD = True 0s ER
I91 F Situation 11 Emergency BWTS By-Pass R0.1 Alarm TBD KEB1 0 Wago Bool TBD TBD = True 0s ER
I96 F Emergency Generator Not Standby R0.1 Alarm TBD KEB1 0 Wago Bool TBD TBD = True ER

0221 F 02_SPPLY – Power Supply 400 VAC Fault R0.1 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0222 F 02_SPPLY – Power Supply 230 VAC Fault R0.1 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0223 F 02_SPPLY – Power Supply 24 VDC Fault R0.1 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0224 F 02_SPPLY – Power Supply 24 VDC UPS Fault R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0225 F 02_SPPLY – PLC KEB Power Module F1 Fuse Blown R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0226 F 02_SPPLY – PLC KEB Power Module F1 Power Fail R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0227 F 02_SPPLY – PLC KEB Power Module F2 Fuse Blown R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0228 F 02_SPPLY – PLC KEB Power Module F2 Power Fail R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0229 F 02_SPPLY – PLC KEB Power Module F3 Fuse Blown R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0230 F 02_SPPLY – PLC KEB Power Module F3 Power Fail R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0353 F 04_FAULT – Global Common Alarm Active R0.1 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0354 F 04_FAULT – Global Common Trip Active R0.1 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER

0558 F 20_DG – DG 1 Diode Temperature High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0559 F 20_DG – DG 1 Generator Winding U Temperature High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0560 F 20_DG – DG 1 Generator Winding U Temperature High High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0561 F 20_DG – DG 1 Generator Winding V Temperature High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0562 F 20_DG – DG 1 Generator Winding V Temperature High High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0563 F 20_DG – DG 1 Generator Winding W Temperature High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0564 F 20_DG – DG 1 Generator Winding W Temperature High High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0565 F 20_DG – DG 1 Generator Bearing Drive End Temperature High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0566 F 20_DG – DG 1 Generator Bearing Drive End Temperature High High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0567 F 20_DG – DG 1 Generator Bearing Non Drive End Temperature High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0568 F 20_DG – DG 1 Generator Bearing Non Drive End Temperature High High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0569 F 20_DG – DG 1 Generator Winding U Temperature Sensor Failure R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0570 F 20_DG – DG 1 Generator Winding V Temperature Sensor Failure R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0571 F 20_DG – DG 1 Generator Winding W Temperature Sensor Failure R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0572 F 20_DG – DG 1 Generator Bearing Drive End Temperature Sensor Failure R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0573 F 20_DG – DG 1 Generator Bearing Non Drive End Temperature Sensor Failure R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0574 F 20_DG – DG 1 Diesel Generator Common Shutdown R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0575 F 20_DG – DG 1 Diesel Generator Common Alarm R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0576 F 20_DG – DG 1 Automatic Voltage Regulator Alarm R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0577 F 20_DG – DG 1 Power Measurement Module Communication Fail R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER

52212021 - Vertom C293 Page 3 / 7


Alarm Commissioning Report 2024/10/01 07:06:35

Acknowledge Location

Sounding Locations
Normal Condition

Disallow Inhibit
Output Contact

Range Upper
Range Lower

Group Alarm
Scale Factor
Class. Appr.
Description

MB Address
Cust. Appr.

MB Server
Data Type

MB Func.
On Delay
Set Point
Checked

Terminal
Revision

Module
Priority

Source
Device

VDR ID

Cat. A
Code

Lock
Type

Unit
GEA
0585 F 20_DG – DG 3 Diode Temperature High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0586 F 20_DG – DG 3 Generator Winding U Temperature High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0587 F 20_DG – DG 3 Generator Winding U Temperature High High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0588 F 20_DG – DG 3 Generator Winding V Temperature High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0589 F 20_DG – DG 3 Generator Winding V Temperature High High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0590 F 20_DG – DG 3 Generator Winding W Temperature High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0591 F 20_DG – DG 3 Generator Winding W Temperature High High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0592 F 20_DG – DG 3 Generator Bearing Drive End Temperature High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0593 F 20_DG – DG 3 Generator Bearing Drive End Temperature High High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0594 F 20_DG – DG 3 Generator Bearing Non Drive End Temperature High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0595 F 20_DG – DG 3 Generator Bearing Non Drive End Temperature High High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0596 F 20_DG – DG 3 Generator Winding U Temperature Sensor Failure R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0597 F 20_DG – DG 3 Generator Winding V Temperature Sensor Failure R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0598 F 20_DG – DG 3 Generator Winding W Temperature Sensor Failure R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0599 F 20_DG – DG 3 Generator Bearing Drive End Temperature Sensor Failure R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0600 F 20_DG – DG 3 Generator Bearing Non Drive End Temperature Sensor Failure R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0601 F 20_DG – DG 3 Diesel Generator Common Shutdown R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0602 F 20_DG – DG 3 Diesel Generator Common Alarm R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0603 F 20_DG – DG 3 Automatic Voltage Regulator Alarm R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0604 F 20_DG – DG 3 Power Measurement Module Communication Fail R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER

0725 F 30_GRID – Transformer Temperature High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0726 F 30_GRID – Transformer Temperature High High R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0727 F 30_GRID – Transformer Temperature Sensor Failure R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0728 F 30_GRID – Drive Fault R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0729 F 30_GRID – Drive Alarm R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0730 F 30_GRID – Drive Comm Fail R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0731 F 30_GRID – Drive Run Lost R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0732 F 30_GRID – Circuit Breaker Tripped R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0733 F 30_GRID – Control Mode Input Failure R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0734 F 30_GRID – Synchronize Mode Input Failure R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0735 F 30_GRID – Remote Control Local Synchronize Undefined State Alarm R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0736 F 30_GRID – Circuit Breaker Opened Unexpected R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER

0937 F 31_THRUST – THRUST PROP 1 Drive Fault R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0938 F 31_THRUST – THRUST PROP 1 Drive Alarm R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0939 F 31_THRUST – THRUST PROP 1 Drive Comm Fail R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0940 F 31_THRUST – THRUST PROP 1 Drive Run Lost R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0941 F 31_THRUST – THRUST PROP 1 Propulsion Control System Network Alarm R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0942 F 31_THRUST – THRUST PROP 1 Propulsion Control System Network Fault R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0943 F 31_THRUST – THRUST PROP 1 Setpoint Deviation Alarm R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0944 F 31_THRUST – THRUST PROP 1 Setpoint Health Alarm R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0945 F 31_THRUST – THRUST PROP 1 Setpoint Fault R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0983 F 31_THRUST – THRUST PROP 1 Drive Temp Sensor Warning R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
0990 F 31_THRUST – THRUST PROP 1 Drive External Warning (Motor Coolwater Leakage) R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
1015 F 31_THRUST – THRUST PROP 1 Drive Temp Sensor Fault R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER

1034 F 31_THRUST – THRUST BOW 1 Drive Fault R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
1035 F 31_THRUST – THRUST BOW 1 Drive Alarm R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
1036 F 31_THRUST – THRUST BOW 1 Drive Comm Fail R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
1069 F 31_THRUST – THRUST BOW 1 Drive Temp Sensor Warning R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
1101 F 31_THRUST – THRUST BOW 1 Drive Temp Sensor Fault R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER

1292 F 31_BCHOP – BCHOP 1 Drive Fault R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
1293 F 31_BCHOP – BCHOP 1 Drive Alarm R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
1294 F 31_BCHOP – BCHOP 1 Drive Comm Fail R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER
1296 F 31_BCHOP – BCHOP 1 Drive Thermistor / PT100 Warning R0.6 Alarm TBD KEB4 0 Wago Bool TBD TBD = True ER

52212021 - Vertom C293 Page 4 / 7


Alarm Commissioning Report 2024/10/01 07:06:35

Acknowledge Location

Sounding Locations
Normal Condition

Disallow Inhibit
Output Contact

Range Upper
Range Lower

Group Alarm
Scale Factor
Class. Appr.
Description

MB Address
Cust. Appr.

MB Server
Data Type

MB Func.
On Delay
Set Point
Checked

Terminal
Revision

Module
Priority

Source
Device

VDR ID

Cat. A
Code

Lock
Type

Unit
GEA
1605 F 01_PLC – Hardware Heartbeat Time Out R0.1 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1606 F 01_PLC – Software Heartbeat Time Out R0.1 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1607 F 01_PLC – Send and Receive Latency High R0.1 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1625 F 02_SPPLY – Power Supply 400 VAC Fault R0.1 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1626 F 02_SPPLY – Power Supply 230 VAC Fault R0.1 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1627 F 02_SPPLY – Power Supply 24 VDC Fault R0.1 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1628 F 02_SPPLY – Power Supply 24 VDC UPS Fault R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1629 F 02_SPPLY – PLC KEB Power Module F1 Fuse Blown R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1630 F 02_SPPLY – PLC KEB Power Module F1 Power Fail R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1631 F 02_SPPLY – PLC KEB Power Module F2 Fuse Blown R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1632 F 02_SPPLY – PLC KEB Power Module F2 Power Fail R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1633 F 02_SPPLY – PLC KEB Power Module F3 Fuse Blown R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1634 F 02_SPPLY – PLC KEB Power Module F3 Power Fail R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1757 F 04_FAULT – Global Common Alarm Active R0.1 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1758 F 04_FAULT – Global Common Trip Active R0.1 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER

1961 F 20_DG – DG 2 Diode Temperature High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1962 F 20_DG – DG 2 Generator Winding U Temperature High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1963 F 20_DG – DG 2 Generator Winding U Temperature High High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1964 F 20_DG – DG 2 Generator Winding V Temperature High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1965 F 20_DG – DG 2 Generator Winding V Temperature High High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1966 F 20_DG – DG 2 Generator Winding W Temperature High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1967 F 20_DG – DG 2 Generator Winding W Temperature High High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1968 F 20_DG – DG 2 Generator Bearing Drive End Temperature High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1969 F 20_DG – DG 2 Generator Bearing Drive End Temperature High High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1970 F 20_DG – DG 2 Generator Bearing Non Drive End Temperature High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1971 F 20_DG – DG 2 Generator Bearing Non Drive End Temperature High High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1972 F 20_DG – DG 2 Generator Winding U Temperature Sensor Failure R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1973 F 20_DG – DG 2 Generator Winding V Temperature Sensor Failure R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1974 F 20_DG – DG 2 Generator Winding W Temperature Sensor Failure R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1975 F 20_DG – DG 2 Generator Bearing Drive End Temperature Sensor Failure R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1976 F 20_DG – DG 2 Generator Bearing Non Drive End Temperature Sensor Failure R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1977 F 20_DG – DG 2 Diesel Generator Common Shutdown R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1978 F 20_DG – DG 2 Diesel Generator Common Alarm R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1979 F 20_DG – DG 2 Automatic Voltage Regulator Alarm R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1980 F 20_DG – DG 2 Power Measurement Module Communication Fail R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER

1988 F 20_DG – DG 4 Diode Temperature High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1989 F 20_DG – DG 4 Generator Winding U Temperature High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1990 F 20_DG – DG 4 Generator Winding U Temperature High High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1991 F 20_DG – DG 4 Generator Winding V Temperature High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1992 F 20_DG – DG 4 Generator Winding V Temperature High High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1993 F 20_DG – DG 4 Generator Winding W Temperature High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1994 F 20_DG – DG 4 Generator Winding W Temperature High High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1995 F 20_DG – DG 4 Generator Bearing Drive End Temperature High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1996 F 20_DG – DG 4 Generator Bearing Drive End Temperature High High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1997 F 20_DG – DG 4 Generator Bearing Non Drive End Temperature High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1998 F 20_DG – DG 4 Generator Bearing Non Drive End Temperature High High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
1999 F 20_DG – DG 4 Generator Winding U Temperature Sensor Failure R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2000 F 20_DG – DG 4 Generator Winding V Temperature Sensor Failure R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2001 F 20_DG – DG 4 Generator Winding W Temperature Sensor Failure R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2002 F 20_DG – DG 4 Generator Bearing Drive End Temperature Sensor Failure R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2003 F 20_DG – DG 4 Generator Bearing Non Drive End Temperature Sensor Failure R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2004 F 20_DG – DG 4 Diesel Generator Common Shutdown R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2005 F 20_DG – DG 4 Diesel Generator Common Alarm R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2006 F 20_DG – DG 4 Automatic Voltage Regulator Alarm R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2007 F 20_DG – DG 4 Power Measurement Module Communication Fail R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER

52212021 - Vertom C293 Page 5 / 7


Alarm Commissioning Report 2024/10/01 07:06:35

Acknowledge Location

Sounding Locations
Normal Condition

Disallow Inhibit
Output Contact

Range Upper
Range Lower

Group Alarm
Scale Factor
Class. Appr.
Description

MB Address
Cust. Appr.

MB Server
Data Type

MB Func.
On Delay
Set Point
Checked

Terminal
Revision

Module
Priority

Source
Device

VDR ID

Cat. A
Code

Lock
Type

Unit
GEA
2128 F 30_GRID – GRID 2 Transformer Temperature High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2129 F 30_GRID – GRID 2 Transformer Temperature High High R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2130 F 30_GRID – GRID 2 Transformer Temperature Sensor Failure R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2131 F 30_GRID – GRID 2 Drive Fault R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2132 F 30_GRID – GRID 2 Drive Alarm R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2133 F 30_GRID – GRID 2 Drive Comm Fail R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2135 F 30_GRID – GRID 2 Circuit Breaker Tripped R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2136 F 30_GRID – GRID 2 Control Mode Input Failure R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2137 F 30_GRID – GRID 2 Synchronize Mode Input Failure R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2138 F 30_GRID – GRID 2 Remote Control Local Synchronize Undefined State Alarm R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2139 F 30_GRID – GRID 2 Circuit Breaker Opened Unexpected R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER

2340 F 31_THRUST – THRUST PROP 2 Drive Fault R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2341 F 31_THRUST – THRUST PROP 2 Drive Alarm R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2342 F 31_THRUST – THRUST PROP 2 Drive Comm Fail R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2343 F 31_THRUST – THRUST PROP 2 Drive Run Lost R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2344 F 31_THRUST – THRUST PROP 2 Propulsion Control System Network Alarm R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2345 F 31_THRUST – THRUST PROP 2 Propulsion Control System Network Fault R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2348 F 31_THRUST – THRUST PROP 2 Setpoint Fault R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2422 F 31_THRUST – THRUST PROP 2 Drive Quick Stop Activated R0.7 Emergency v TBD KEB5 0 Wago Bool TBD TBD = True ER

2695 F 31_BCHOP – BCHOP 2 Drive Fault R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2696 F 31_BCHOP – BCHOP 2 Drive Alarm R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER
2697 F 31_BCHOP – BCHOP 2 Drive Comm Fail R0.6 Alarm TBD KEB5 0 Wago Bool TBD TBD = True ER

2827 F 03_THERM – Pump 1 Power Supply Failed R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2828 F 03_THERM – Pump 2 Power Supply Failed R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2829 F 03_THERM – Pump 1 Standby Started R0.5 Warning TBD KEBR Generic Bool TBD TBD = True ER
2830 F 03_THERM – Pump 2 Standby Started R0.5 Warning TBD KEBR Generic Bool TBD TBD = True ER
2831 F 03_THERM – Pump 1 Delta Pressure Low R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2832 F 03_THERM – Pump 2 Delta Pressure Low R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2833 F 03_THERM – BT1 Temperature In High R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2834 F 03_THERM – BT1 Temperature In High High R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2835 F 03_THERM – BT1 Temperature In Sensor Failure R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2836 F 03_THERM – BT2 Temperature Out High R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2837 F 03_THERM – BT2 Temperature Out High High R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2838 F 03_THERM – BT2 Temperature out Sensor Failure R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2839 F 03_THERM – BT1 / BT2 Delta Temperature High R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2840 F 03_THERM – BT1 / BT2 Delta Temperature High High R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2841 F 03_THERM – BP1 Pressure In Low R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2842 F 03_THERM – BP1 Pressure In Low Low R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2843 F 03_THERM – BP1 Pressure In High R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2844 F 03_THERM – BP1 Pressure In Sensor Failure R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2845 F 03_THERM – BP2 Pressure Out Low R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2846 F 03_THERM – BP2 Pressure Out Low Low R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2847 F 03_THERM – BP2 Pressure Out High R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2848 F 03_THERM – BP2 Pressure Out Sensor Failure R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2849 F 03_THERM – BP1 / BP2 Delta Pressure Low R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2850 F 03_THERM – BP1 / BP2 Delta Pressure High R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2855 F 03_THERM – Heater Power Supply Failure R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2856 F 03_THERM – Cabinet Ventilation Fans 1 Circuit Breaker Tripped R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2857 F 03_THERM – Cabinet Ventilation Fans 2 Circuit Breaker Tripped R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER
2858 F 03_THERM – Coolwater Leakage R0.5 Alarm TBD KEBR Generic Bool TBD TBD = True ER

52212021 - Vertom C293 Page 6 / 7


Alarm Commissioning Report 2024/10/01 07:06:35

Acknowledge Location

Sounding Locations
Normal Condition

Disallow Inhibit
Output Contact

Range Upper
Range Lower

Group Alarm
Scale Factor
Class. Appr.
Description

MB Address
Cust. Appr.

MB Server
Data Type

MB Func.
On Delay
Set Point
Checked

Terminal
Revision

Module
Priority

Source
Device

VDR ID

Cat. A
Code

Lock
Type

Unit
GEA
3046 F DG 1 AVR – DC Current Measurement Sensor Failure R1.3 Alarm TBD KEB8 0 Wago Bool TBD TBD = True ER
3047 F DG 1 AVR – DC Voltage Measurement Sensor Failure R1.3 Alarm TBD KEB8 0 Wago Bool TBD TBD = True ER
3048 F DG 1 AVR – DC NO LOAD Voltage Setpoint Sensor Failure R1.3 Alarm TBD KEB8 0 Wago Bool TBD TBD = True ER
3049 F DG 3 AVR – DC Current Measurement Sensor Failure R1.3 Alarm TBD KEB8 0 Wago Bool TBD TBD = True ER
3050 F DG 3 AVR – DC Voltage Measurement Sensor Failure R1.3 Alarm TBD KEB8 0 Wago Bool TBD TBD = True ER
3051 F DG 3 AVR – DC NO LOAD Voltage Setpoint Sensor Failure R1.3 Alarm TBD KEB8 0 Wago Bool TBD TBD = True ER
3099 F DG 2 AVR – DC Current Measurement Sensor Failure R1.3 Alarm TBD KEB9 0 Wago Bool TBD TBD = True ER
3100 F DG 2 AVR – DC Voltage Measurement Sensor Failure R1.3 Alarm TBD KEB9 0 Wago Bool TBD TBD = True ER
3101 F DG 2 AVR – DC NO LOAD Voltage Setpoint Sensor Failure R1.3 Alarm TBD KEB9 0 Wago Bool TBD TBD = True ER
3102 F DG 4 AVR – DC Current Measurement Sensor Failure R1.3 Alarm TBD KEB9 0 Wago Bool TBD TBD = True ER
3103 F DG 4 AVR – DC Voltage Measurement Sensor Failure R1.3 Alarm TBD KEB9 0 Wago Bool TBD TBD = True ER
3104 F DG 4 AVR – DC NO LOAD Voltage Setpoint Sensor Failure R1.3 Alarm TBD KEB9 0 Wago Bool TBD TBD = True ER
3105 F DG 1 AVR – DC Voltage Measurement Failure R1.3 Alarm TBD KEB8 0 Wago Bool TBD TBD = True ER
3106 F DG 3 AVR – DC Voltage Measurement Failure R1.3 Alarm TBD KEB8 0 Wago Bool TBD TBD = True ER
3107 F DG 2 AVR – DC Voltage Measurement Failure R1.3 Alarm TBD KEB9 0 Wago Bool TBD TBD = True ER
3108 F DG 3 AVR – DC Voltage Measurement Failure R1.3 Alarm TBD KEB9 0 Wago Bool TBD TBD = True ER

52212021 - Vertom C293 Page 7 / 7